header advert
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Volume 85-B, Issue 4 May 2003

DUPUYTREN’S DISEASE Pages 469 - 477
Access Required
A. J. Thurston
View article
Download PDF

Access Required
P. V. Giannoudis
View article
Download PDF

A. T. Helm M. T. Karski S. J. Parsons J. S. Sampath R. S. Bale
View article
Download PDF

We prospectively audited 79 patients undergoing primary knee or hip arthroplasty (38 knees, 41 hips) and found that 66% (58% of knees, 73% of hips) had at least one unit of blood transfused postoperatively, with a mean transfusion requirement of 1.3 units per patient (1.1 for knees, 0 to 6; 1.5 for hips, 0 to 4).

We then established a new protocol for postoperative blood transfusion. This requires the calculation of the maximum allowable blood loss (MABL) that each individual patient can safely lose based upon their weight and preoperative haematocrit. The total blood loss up to this volume is replaced with colloid. When a patient’s total blood loss reaches their MABL their haematocrit is measured at the bedside using the Microspin system (Bayer plc, Newbury, UK). If their haematocrit is low (< 0.30 for men, < 0.27 for women), blood is transfused. As a safety net all patients have their haemoglobin formally checked on days 1, 2, and 3 after surgery and have a transfusion if the haemoglobin levels are less than 8.5 g/dl.

We conducted a further audit of 82 patients (35 knees, 47 hips) after the introduction of this protocol. Under the new protocol only 24% of patients required blood (11% of knees, 34% of hips) with a mean transfusion requirement of 0.56 units per patient (0.26 for knees, 0 to 4; 0.79 for hips, 0 to 4).

The use of clinical audit and the introduction of strict guidelines for transfusion can change transfusion practice and result in improved patient care. Our transfusion protocol is a simple and effective method of keeping transfusion to a minimum and is particularly useful in departments which do not have the facility to use autologous blood or reinfusion drains for elective orthopaedic surgery.


Access Required
J. Der Tavitian S. M. Ong N. A. Taub G. J. S. Taylor
View article
Download PDF

We randomly allocated 50 total knee replacements to scrub teams wearing body-exhaust suits (BES) or Rotecno occlusive clothing. The effectiveness of the clothing was assessed using air and wound bacterial counts.

Bacteria were recovered from 62% of wounds (64% BES, 60% Rotecno). The mean air count was 0.5 CFU/ m3 with BES and 1.0 CFU/m3 with Rotecno (p = 0.014). The mean wound counts were 14 bacteria/wound with BES and eight bacteria/wound with Rotecno (p = 0.171). There was no correlation between the air and wound counts (r = −0.011, Spearman’s).

The higher air counts suggest that Rotecno occlusive clothing is less effective than BES, but wounds were equally contaminated with both types of clothing suggesting that at very low levels of air contamination the contribution of bacteria to the wound from the air is irrelevant. Even doubling the air counts from 0.5 to 1.0 CFU/m3 had no detectable effect on the wound.

This allows a reassessment to be made of other sources of contamination the effect of which would previously have been overwhelmed by contamination from air.


R. B. G. Brokelman C. J. M. van Loon W. J. Rijnberg
View article
Download PDF

We compared patient satisfaction with surgeon satisfaction after total hip arthroplasty (THA) in a group of 193 patients (200 THAs, mean follow-up six years) using a visual analogue scale (VAS), and two objective and two subjective scoring systems. We also determined the survival rate with different endpoints. For the 121 hips available for clinical follow-up, we did not find a significant difference in satisfaction between patient and surgeon. In a subgroup with low patient satisfaction, the surgeon was more satisfied than the patient (p = 0.04). The correlation between the patient satisfaction VAS and the different subjective and objective scoring systems suggests that pain during activity is the most important factor for the patient. The survivorship at six years decreased from 96.6% to 83.7% if dissatisfaction (VAS > 20) was added to revision as an endpoint in the survival analysis. The patient satisfaction VAS provides additional information to evaluate the outcome of THA. We recommend the use of both subjective and objective scoring systems to evaluate the outcome of THA.


N. Aebli J. Krebs D. Schwenke H. Stich P. Schawalder J.-C. Theis
View article
Download PDF

We carried out a histological study of a proximally hydroxyapatite (HA)-coated femoral component, retrieved after 9.5 years of good function. The HA coating had completely degraded. Bone was in direct contact with the titanium surface in all the areas which had been coated, with no interposing fibrous tissue. There were no signs of particles, third-body wear, adverse tissue reactions or osteolysis. Bone remodelling was evident by the presence of resorption lacunae; tetracycline labelling showed bone laid down six years after implantation.

The loss of the HA-coating had no negative effect on the osseo-integration of the stem. We conclude that the HA coating contributes to the fixation of the implant and that its degradation does not adversely affect the long-term fixation.


P. Hernigou T. Bahrami
View article
Download PDF

Although alumina has been used in orthopaedic surgery since the 1970s, the long-term clinical results of zirconia have not been well documented in vivo. We studied hips with these two different ceramics during the same period and with a minimum follow-up of ten years. Because the size of the alumina and zirconia heads was different, hips with 32 mm alumina heads and those with 28 mm zirconia heads were compared with control hips with stainless-steel heads of the same size. Our aim was to compare the two ceramics.

There was an increased linear rate of penetration of the femoral heads into the liner between years five and 12 for the zirconia and the stainless-steel groups. This was severe in the zirconia group (0.4 mm/year compared with 0.13 mm/year for the stainless-steel group). During the same 12-year period there was, however, no significant change in the rate of wear in the alumina group (0.07 mm/year). The mean wear at the most recent follow-up was 1360 mm3 for the 28 mm zirconia group, 683 mm3 for the 28 mm stainless-steel group, 755 mm3 for the 32 mm alumina group and 1314 mm3 for the 32 mm stainless-steel group. The monoclinic content rose on the surface of three zirconia heads which were retrieved at revision. This change was associated with an increase in the surface roughness. A change in the roundness with an increase in the sphericity deviation was also observed both in the articular and non-articular parts of the femoral heads. The increase in rate of wear in the zirconia group was only evident after eight years and may be linked to a long-term biodegradation of zirconia in vivo, associated with the altered roughness and roundness which was observed on the retrieved heads.


F. Langlais J. C. Lambotte Ph. Collin F. Langlois J. W. Fontaine H. Thomazeau
View article
Download PDF

We used a trochanteric slide osteotomy (TSO) in 94 consecutive revision total hip arthroplasties (90 with replacement of both the cup and stem). This technique proved to be adequate for removing the components, with few complications (two minor fractures), and for implanting acetabular allografts (18%) and reinforcement devices (23%). Trochanteric union was obtained in most patients (96%), even in those with septic loosening (18/19), major femoral osteolysis (32/32), or previous trochanteric osteotomy (17/18). TSO is versatile, since it can be extended by a femoral flap (four cases) or a distal femoral window (eight cases). Despite significant bone loss, in 24% of the femora and 57% of the acetabula, favourable midterm results were achieved and only six reoperations were required, including two for trochanteric nonunion and two for loosening. It leaves the lateral femoral cortex intact so that a stem longer than 200 mm was needed in only 25% of patients. This is a considerable advantage compared with the extended trochanteric osteotomy in which the long lateral flap (12 to 14 cm) requires an average length of stem of 220 mm beyond the calcar.

TSO provides an approach similar in size to the standard trochanteric osteotomy but with a rate of nonunion of 4% versus 15%. It reduces the risk of difficulties with removal of the stem, and removes the need for routine distal anchoring of long revision stems. The limited distal femoral compromise is very important in patients with a long life expectancy.


D. C. Mackay M. S. Siddique
View article
Download PDF

We have compared the survival of 67 revision arthroplasties of the knee undertaken for aseptic loosening with and without the retention of a secure, cemented femoral component. All the patients had undergone a single primary procedure at a mean of nine years previously. In group I (25 knees) the original femoral component was secure and was retained. There were no abrasions or osteolysis. The knees were stable, normally aligned, with minimal bone loss. In group II 42 knees did not fulfil these criteria and underwent revision of both components. The mean follow-up was four years.

Re-revision for loosening was required in seven knees (28%) in group I and three (7%) in group II (p < 0.01). The remaining knees function well with Knee Society scores averaging 84/69 and no radiological evidence of osteolysis. When revising cemented implants, retention of a secure femoral component cannot be recommended even when conditions appear to be suitable.


A. A. S. Meighan J. F. Keating E. Will
View article
Download PDF

We randomised 31 patients with acute tears of the anterior cruciate ligament (ACL) to receive either early (within 2 weeks) or delayed (8 to 12 weeks) reconstruction using a quadruple hamstring graft in order to determine if there was any functional advantage to early reconstruction. Outcome measures included return of knee movement, muscle dynamometry, International Knee Documentation Committee (IKDC) scores and Tegner activity levels.

Two cases of symptomatic deep-venous thrombosis occurred in the early group. The mean range of movement was significantly greater at two weeks in the delayed group. Quadriceps muscle power was significantly better in the delayed group at 12 weeks (p < 0.05). These trends were evident at later time points, but were not statistically significant. One patient in each group had clinically significant knee stiffness at 52 weeks. IKDC scores and Tegner activity levels were not significantly different at 52 weeks. We conclude that there is no functional advantage to be gained by early reconstruction of the ACL.


A. C. M. Pijnenburg K. Bogaard R. Krips R. K. Marti P. M. M. Bossuyt C. N. van Dijk
View article
Download PDF

Consecutive patients with a confirmed rupture of at least one of the lateral ligaments of the ankle were randomly assigned to receive either operative or functional treatment. They were evaluated at a median of 8 years (6 to 11).

In total, 370 patients were included. Follow-up was available for 317 (86%). Fewer patients allocated to operative treatment reported residual pain compared with those who had been allocated to functional treatment (16% versus 25%, RR 0.64, CI 041 to 1.0). Fewer surgically-treated patients reported symptoms of giving way (20% versus 32%, RR 0.62, CI 0.42 to 0.92) and recurrent sprains (22% versus 34%, RR 0.66, CI 0.45 to 0.94). The anterior drawer test was less frequently positive in surgically-treated patients (30% versus 54%, RR 0.54, CI 0.41 to 0.72). The median Povacz score was significantly higher in the operative group (26 versus 22, p < 0.001).

Compared with functional treatment, operative treatment gives a better long-term outcome in terms of residual pain, recurrent sprains and stability.


Y. Murata M. Yamagata S. Ogata K. Shimizu Y. Ikeda J. Hirayama H. Yamada
View article
Download PDF

In order to determine the influence of early ambulation and other factors on headaches occurring after lumbar myelography we randomised 207 patients (127 men and 80 women) into two groups. Following the investigation, we allowed the 101 patients (65 men and 36 women) in group A to sit or stand freely, while we confined the 106 patients (62 men and 44 women) in group B to bed for 20 hours. The nine patients in group B who could not maintain bed rest were excluded.

There was no significant difference between the two groups as regards the prevalence of spinal headache (8.9% in group A v 14.4% in group B). Patients who reported headaches, however, were significantly more likely to be women (18.7%) than men (7.3%), be younger (mean age 45 years v 56 years), have a higher cerebrospinal pressure before removal of fluid (mean values 172 v 137 mm H2O) and a lower systolic (mean values 120 v 134 mmHg) and diastolic blood pressure.

We conclude that, although other factors may be associated with headaches, late ambulation is not effective in preventing spinal headaches after lumbar myelography.


P. Gaston R. W. Marshall
View article
Download PDF

Studies on recurrent disc herniation quote rates of recurrence without regard to the times of recurrence and the influence of longer follow-up. Our objective was to assess the use of survival analysis to measure the rate of revision after lumbar microdiscectomy. We undertook a retrospective analysis of the hospital records of 993 patients who underwent lumbar microdiscectomy over a period of ten years. After calculating the overall rate of revision for the mean length of follow-up, we carried out a survival analysis using the life-table method. During the study period 49 patients had a revision microdiscectomy. This gave an overall rate of revision of 4.9% at a mean follow-up of 5.25 years. Using survival analysis, the rate of revision was 7.9% at a follow-up of ten years when the number at risk was 84. Survival analysis gives a more accurate estimation of the true rate of recurrence for patients undergoing lumbar microdiscectomy. The method allows better comparison between different interventions for disc herniation.


Upper Limb
Access Required
A. Ericson A. Arndt A. Stark P. Wretenberg A. Lundberg
View article
Download PDF

We analysed the axis of movement in the normal elbow during flexion in vivo using radiostereometric analysis (RSA). The results show an intraindividual variation in the inclination of the axis ranging from 2.1° to 14.3° in the frontal and from 1.6° to 9.8° in the horizontal plane analysed at 30° increments. The inclination of the mean axis of rotation varied within a range of 12.7° in the frontal and 4.6° in the horizontal plane. In both planes, the mean axes were located close to a line joining the centres of the trochlea and capitellum. The intra- and interindividual variations of the axes of flexion of the elbow were greater than previously reported. These factors should be considered in the development of elbow prostheses.


T. D. Boehm M. Matzer D. Brazda F. E. Gohlke
View article
Download PDF

Os acromiale is a rare anatomical abnormality and treatment is controversial. Our retrospective study analyses the outcome of excision, acromioplasty and bony fusion of the os acromiale when it is associated with a tear of the rotator cuff.

After a mean follow-up of 41 months, 33 patients were radiologically and clinically assessed using the Constant score. The surgical procedure was to repair the rotator cuff together with excision of the os acromiale in six patients, acromioplasty in five, and fusion in 22.

Of the 22 attempted fusions seven failed radiologically. The Constant scores were 82%, 81%, 81% and 84% for patients who had excision, acromioplasty, successful fusion and unsuccessful fusion respectively. There were no statistically significant differences.

We conclude that a small mobile os acromiale can be resected, a large stable os acromiale treated by acromioplasty and a large unstable os acromiale by fusion to the acromion. Even without radiological fusion the clinical outcome can be good.


Lower Limb
Access Required
R. Coull T. Raffiq L. E. James M. M. Stephens
View article
Download PDF

We assessed the long-term outcome of open debridement for the treatment of anterior impingement of the ankle in 27 patients. By using preoperative radiographs to group patients according to both the McDermott and the van Dijk scoring system, we assessed the accuracy of these classifications in predicting outcome. The Ogilvie-Harris scoring system, a visual analogue scale of patient satisfaction, the time to return to full activities, and the ability to return to sports determined the clinical outcome. Follow-up radiographs were used to assess the recurrence of osteophytes. We also assessed the incidence of talar osteochondral lesions at surgery.

At a mean follow-up of 7.3 years, 23 of 25 patients (92%) without joint-space narrowing had a good or excellent result. Improvement in the Ogilvie-Harris score was seen in all patients. In athletes, 19 of 24 (79%) were able to return to sports at the same level. Two patients with preoperative joint-space narrowing had a poor result.

Osteophytes usually recurred and most patients did not feel that the range of dorsiflexion returned to normal, but symptomatic relief allowed most to return to high-level sport.

Our results for non-arthritic joints suggest that this is a safe and successful procedure.


Access Required
A. Daigeler H. Fansa W. Schneider
View article
Download PDF

Reimplantation is a well-established procedure in reconstructive surgery. This is especially so after amputation of the upper limb since prostheses provide limited function. In unilateral amputation of the lower leg orthotopic reimplantation is the treatment of choice. With bilateral amputation, in which orthotopic reimplantation is not possible because of the complexity of the trauma, heterotopic reimplantation is an option.

We report five patients who received orthotopic and two who received heterotopic reimplantations of the lower leg. We assessed the functional outcome with reference to cutaneous sensation, mobility, pain, and the cosmetic result.

The functional outcome was good, as was the patients’ satisfaction. Their mobility, stability, and psychological state were satisfactory. Patients with heterotopic reimplantations preferred the reimplanted leg to a prosthesis. Although reimplantation of the lower leg requires prolonged hospitalisation, delayed mobilisation and secondary operations, we conclude that there is an indication for this operation in order to improve the patient’s quality of life.


Children's Orthopaedics
Access Required
A. Hempfing R. Placzek T. Göttsche A. L. Meiss
View article
Download PDF

We present three children with primary subacute epiphyseal and metaepiphyseal osteomyelitis. The diagnosis was delayed because of subtle radiological findings and mild general symptoms. Primary epiphyseal osteomyelitis is extremely rare. We believe that this is the first time that the MRI findings have been presented. In the first case they revealed a perforation into the knee and therefore an intra-articular epiphyseal approach was used for debridement. In the second and third cases the metaepiphyseal lesions showed considerable physical involvement and a metaphyseal approach was chosen. We believe that in this condition MRI is essential both for diagnosis and in the planning of surgical treatment.


S. Jones H. S. Hosalkar R. A. Hill J. Hartley
View article
Download PDF

We have treated seven children with relapsed infantile Blount’s disease by elevation of the hemiplateau using the Ilizarov frame.

Three boys and four girls with a mean age of 10.5 years were reviewed at a mean of 29 months after surgery. All had improved considerably and were pleased with the results. The improvements in radiological measurements were statistically significant (p < 0.001). Three-dimensional CT reconstruction was useful for planning surgery. There were no major complications. The advantages of this technique are that in addition to elevation of the hemiplateau, rotational deformities and limb-length discrepancies may be addressed.


T. N. Theologis M. E. Harrington N. Thompson M. K. D. Benson
View article
Download PDF

The aim of this study was to define objectively gait function in children with treated congenital talipes equinovarus (CTEV) and a good clinical result. The study also attempted an analysis of movement within the foot during gait. We compared 20 children with treated CTEV with 15 control subjects. Clinical assessment demonstrated good results from treatment. Three-dimensional gait analysis provided kinematic and kinetic data describing movement and moments at the joints of the lower limb during gait. A new method was used to study movement within the foot during gait. The data on gait showed significantly increased internal rotation of the foot during walking which was partially compensated for by external rotation at the hip. A mild foot drop and reduced plantar flexor power were also observed. Dorsiflexion at the midfoot was significantly increased, which probably compensated for reduced mobility at the hindfoot. Patients treated for CTEV with a good clinical result should be expected to have nearly normal gait and dynamic foot movement, but there may be residual intoeing, mild foot drop, loss of plantar flexor power with compensatory increased midfoot dorsiflexion and external hip rotation.


H. S. Hosalkar D. H. Jones A. Offiah C. Hall
View article
Download PDF

The association between vitamin-D-resistant rickets and linear sebaceous naevus syndrome is extremely rare. Only eight cases have been described in the English literature and in none were the skeletal aspects addressed. We present three new cases and describe the musculoskeletal features. The details and outcome of surgery for correction of the deformities are discussed. The disturbances of metabolism of vitamin D and the effects of pharmacological treatment are also described.


Case report Pages 584 - 586
Access Required
A. A. Faundez D. Ceroni A. Kaelin
View article
Download PDF

A six-year-old girl sustained a Monteggia type-I equivalent fracture of the right forearm. We describe the method of treatment of this rare fracture and its outcome.


S. A. W. Pickering R. Bayston B. E. Scammell
View article
Download PDF

Infection of orthopaedic implants is a significant problem, with increased antibiotic resistance of adherent ‘biofilm’ bacteria causing difficulties in treatment. We have investigated the in vitro effect of a pulsed electromagnetic field (PEMF) on the efficacy of antibiotics in the treatment of infection of implants.

Five-day biofilms of Staphylococcus epidermidis were grown on the tips of stainless-steel pegs. They were exposed for 12 hours to varying concentrations of gentamicin or vancomycin in microtitre trays at 37°C and 5% CO2. The test group were exposed to a PEMF. The control tray was not exposed to a PEMF. After exposure to antibiotic the pegs were incubated overnight, before standard plating onto blood agar for colony counting.

Exposure to a PEMF increased the effectiveness of gentamicin against the five-day biofilms of Staphylococcus epidermidis. In three of five experiments there was reduction of at least 50% in the minimum biofilm inhibitory concentration. In a fourth experiment there was a two-log difference in colony count at 160 mg/l of gentamicin. Analysis of variance (ANOVA) confirmed an effect by a PEMF on the efficacy of gentamicin which was significant at p < 0.05. There was no significant effect with vancomycin.


P. Reilly A. A. Amis A. L. Wallace R. J. H. Emery
View article
Download PDF

Differential strain has been proposed to be a causative factor in failure of the supraspinatus tendon. We quantified the strains on the joint and bursal sides of the supraspinatus tendon with increasing load (20 to 200 N) and during 120° of glenohumeral abduction with a constant tensile load (20 to 100 N).

We tested ten fresh frozen cadaver shoulders on a purpose-built rig. Differential variable reluctance extensometers allowed calculation of the strain.

Static loading to 100 N or more increased strains on the joint side significantly more than on the bursal side. During glenohumeral abduction an increasing and significant difference in strain was measured between the joint and bursal sides of the supraspinatus tendon, which reached a maximum of 10.6% at abduction of 120°. The joint side strain of 7.5% reached values which were previously reported to cause failure.

Differential strain causes shearing between the layers of the supraspinatus tendon, which may contribute to the propagation of intratendinous defects that are initiated by high joint side strains.


H. Sameda Y. Takahashi K. Takahashi T. Chiba S. Ohtori H. Moriya
View article
Download PDF

Dorsal root ganglion neurones with dichotomising axons are present in several species and are considered to play a role in referred pain. Clinically, patients with lesions in the lower lumbar discs occasionally complain of pain in the groin. We investigated the existence of dichotomising afferent neurones projecting axons both to the lumbar disc and to the groin skin, using the double fluorescent-labelling technique in rats.

We observed neurones labelled with a tracer applied at the ventral portion of the L5-L6 disc and another tracer placed on the groin skin in L1 and L2 dorsal root ganglia. Our results showed that the double-labelled neurones had peripheral axons which dichotomised into both the L5-L6 disc and the groin skin, indicating the convergence of afferent sensory information from the disc and groin skin. Our findings provide a possible neuroanatomical mechanism for referred groin pain in patients with disc lesions.


Access Required
A. A. C. Reed C. J. Joyner S. Isefuku H. C. Brownlow A. H. R. W. Simpson
View article
Download PDF

Our aim was to develop a clinically relevant model of atrophic nonunion in the rat to test the hypothesis that the vessel density of atrophic nonunion reaches that of normal healing bone, but at a later time-point. Atrophic nonunion is usually attributed to impaired blood supply and is poorly understood.

We determined the number of blood vessels at the site of an osteotomy using immunolocalisation techniques in both normally healing bones and in atrophic nonunion. At one week after operation there were significantly fewer blood vessels in the nonunion group than in the healing group. By eight weeks, the number in the atrophic nonunion group had reached the same level as that in the healing group.

Our findings suggest that the number of blood vessels in atrophic nonunion reaches the same level as that in healing bone, but at a later time-point. Diminished vascularity within the first three weeks, but not at a later time-point, may prevent fractures from uniting.


M. J. Tingart M. Apreleva D. von Stechow D. Zurakowski J. J. P. Warner
View article
Download PDF

The operative treatment of fractures of the proximal humerus can be complicated by poor bone quality. Our aim was to evaluate a new method which allows prediction of the bone quality of the proximal humerus from radiographs.

Anteroposterior radiographs were taken of 19 human cadaver humeri. The cortical thickness was measured at two levels of the proximal humeral diaphysis. The bone mineral density (BMD) was determined for the humeral head (HH), the surgical neck (SN), the greater tuberosity (GT) and lesser tuberosity (LT) using dual-energy x-ray absorptiometry.

The mean cortical thickness was 4.4 ± 1.0 mm. Specimens aged 70 years or less had a significantly higher cortical thickness than those aged over 70 years. A significant positive correlation was found between cortical thickness and the BMD for each region of interest.

The cortical thickness of the proximal diaphysis is a reliable predictor of the bone quality of the proximal humerus.


V. GUZZANTI
View article
Download PDF

Access Required
B. DARLING P. GREGG
View article
Download PDF

Author’s reply Pages 619 - 619
Access Required
P. AICHROTH
View article
Download PDF

A. M. HIDALGO-OVEJERO S. GARCIA-MATA M. MARTINEZ-GRANDE I. OTERMIN-MAYA
View article
Download PDF

Author’s reply Pages 620 - 620
Access Required
D. WARWICK
View article
Download PDF

M. WASEEM
View article
Download PDF

Arthroplasty of the hip Pages 620 - 621
Access Required
R. A. ELSON
View article
Download PDF

Author’s reply Pages 620 - 620
Access Required
J. G. B. MACLEAN
View article
Download PDF

Authors’ reply Pages 621 - 621
Access Required
T. O. WHITE T. W. DOUGALL
View article
Download PDF

David Hunt
View article
Download PDF

W. A. Souter
View article
Download PDF