Receive monthly Table of Contents alerts from The Bone & Joint Journal
Comprehensive article alerts can be set up and managed through your account settings
View my account settingsWe studied 16 femora retrieved at post-mortem from symptomless patients who had a satisfactory cemented total hip arthroplasty from two weeks to 17 years earlier, with the aim of delineating the initial mechanisms involved in loosening. Only one specimen showed radiographic evidence of loosening; the other 15 were stable to mechanical testing at 17.0 Nm of torque. In all 16 specimens, the cement-bone interface was intact with little fibrous tissue formation. By contrast, separation at the cement-prosthesis interface and fractures in the cement mantle were frequent. The most common early feature was debonding of the cement from the metal, seen at the proximal and distal ends of the prosthesis. Specimens which had been in place for longer also showed circumferential fractures in the cement, near the cement-metal interface, and radial fractures extending from this interface into the cement and sometimes to the bony interface. The most extensive cement fractures appeared to have started at or near sharp corners in the metal, or where the cement mantle was thin or incomplete. Fractures were also related to voids in the cement. The time relationship in this series suggested that long-term failure of the fixation of cemented femoral components was primarily mechanical, starting with debonding at the interface between the cement and the prosthesis, and continuing as slowly developing fractures in the cement mantle.
Thirteen total hip replacements with titanium alloy femoral components required revision for loosening at an average of two years after implantation. At revision the soft tissues around the implant were darkly stained and a proliferative membrane had invaded the cement-bone interface. The femoral components showed polishing of parts of their shot-blasted surfaces. Histology showed a fibroblastic reaction with abundant titanium lying free and within histiocytes, and a scanty foreign-body giant-cell reaction. Surface analysis of the removed femoral components and chemical analysis of the excised tissues is described. Tissue reaction in response to the metal-wear debris may have contributed to the early failure of these implants.
The results of 276 cemented revision total hip arthroplasties performed for aseptic failure between 1977 and 1986 have been reviewed. The mean time between revision and review was 75 months (range 30 to 144). Of 220 cases available for review, 159 were assessed clinically and radiographically, and 32 by postal questionnaire. Eighteen hips required further revision, 12 for loosening, two for sepsis, two for persistent pain, and one each for fracture and recurrent dislocation. A further six hips were radiologically and symptomatically loose. Pain was mild or absent in 83%. Over half were able to walk a mile or more; 70% flexed more than 70 degrees; 15% had a flexion deformity, but in only 7% was this more than 10 degrees. The mean Harris hip score was 74. Survival at five years was 95% and at 10 years, 77%.
Nine uncemented hip prostheses of modular design were revised because of late infection (2 cases), femoral stem loosening or fracture (2), loosening of threaded cups (3) and protrusion of bipolar cups (2). At surgery we found tissue discoloration and macroscopic corrosion in four of the nine prostheses, located at the head-neck junction. Histological examination in most cases showed extensive necrosis associated with metal particles, indicating metal toxicity. Metallographic examination of the prosthetic heads revealed structural imperfections and inhomogeneity of the metal. We suggest that the crevice between the head and neck is a potential site of corrosion in modular designs.
We report six cases of contralateral limb involvement during total hip arthroplasty including swelling of the gluteal muscle compartments, rhabdomyolysis, myoglobinuria, and sciatic nerve palsy. The risk factors for such complications include obesity, prolonged operative time, and positioning in the lateral decubitus position. The laboratory and clinical findings are consistent with a gluteal muscle crush-injury with consequent compartment syndrome. The patients should be treated conservatively as symptoms can be expected to resolve.
We used the stainless steel cable grip system described by Dall and Miles in 1983 to fix trochanters in 40 hips after total arthroplasty with trochanteric osteotomy. The cable broke in 32.5% of the hips; the trochanter failed to unite in 37.5%. Significantly more cables broke when placed inside the femoral canal than when the cable was placed round the femoral shaft (58% as against 9.5%, difference p less than 0.01). The high incidence of breakage may have resulted from contact between the stainless steel cable and the titanium prosthesis, from the acute angulation, or because of the lower fatigue strength of stainless steel. Better results have been obtained using cables with a higher fatigue strength, passed outside the proximal femur.
Medial tibial plateaux excised during 46 unicompartmental arthroplasties for osteoarthritis were collected and photographed. The anterior cruciate ligament was intact in all joints. In every case the cartilage and bone erosion was centred anteriorly on the plateau and the posterior cartilage was intact. The site of the lesion and the intact state of the cruciate ligaments taken together explain why varus deformity was observed only in the extended knee, and why the deformity was correctable and had not become fixed. Failure of the anterior cruciate ligament may allow the erosion to extend posteriorly, producing fixed varus deformity and leading to degeneration of the lateral compartment. Anteromedial osteoarthritis is a distinct clinicopathological entity; its radiographic features enable it to be diagnosed from lateral radiographs; its anatomical features render it suitable for treatment by unicompartmental arthroplasty.
Angiogenin, a potent blood vessel inducing protein, was implanted into experimentally injured menisci of 75 New Zealand white rabbits. Localised neovascularisation occurred in 52% of the angiogenin-treated animals, and in 9% of the controls. Neovascularisation induced by angiogenin may enhance healing of injuries within the poorly vascularised meniscal fibrocartilage, and improve the results of meniscal repair.
We undertook a prospective controlled clinical trial of 109 patients to determine whether postoperative blood salvage in patients undergoing total hip or knee arthroplasty decreased the need for transfusion with banked blood. The average amount of blood collected in our series was 493 ml, most of which was collected in the first four postoperative hours. In patients undergoing bilateral total knee arthroplasty, there was a 54% reduction in banked blood utilisation. None of our patients developed adverse effects from the reinfused material. The cost of collecting and processing wound drainage using the Haemolite cell washer was $175 per patient, regardless of the volume processed, compared to $125 for a unit of banked blood. By reducing the requirement for homologous transfusion, blood salvage diminishes the risks of transmission of HIV and hepatitis viruses. In those cases where the equivalent of two units of blood are reinfused, blood salvage saves money. However, due to the small amounts of blood collected in unilateral hip or knee arthroplasty, we do not recommend its routine application in these cases.
The early results of revision osteoarticular allografts in weight-bearing joints are reported. Sixteen consecutive patients underwent surgery over a six-year period between 1982 and 1988. At the time of review eight patients (50%) had surviving second allografts with an average follow-up time of 48 months (range 12 to 87). Five patients were graded excellent according to the Mankin scale, one good and two fair. Eight patients (50%) required further surgery, but only two patients came to amputation.
The effect of the position of splintage on displacement of fractures of the waist of the scaphoid was studied during operations and in cadavers. We found that these fractures were best splinted in neutral or slight palmar flexion with no ulnar deviation. Providing the wrist was not ulnar deviated, the position of the thumb had no effect on displacement.
We report the long-term results of the Matti-Russe operation for pseudarthrosis of the scaphoid in 100 cases, reported previously by Mulder in 1968. Clinical results for 77 patients and radiographic data for 74 were reviewed at 22 to 34.8 years after surgery. In general, there was satisfactory relief of pain and stiffness but some patients had limitation of motion and reduced grip-strength, with usually slight osteoarthritic changes. There was poor correlation between subjective, objective, and radiographic results but 88% of the patients were satisfied with their results.
Fifty-three of 55 consecutive elbow replacements for post-traumatic arthritis were followed for a minimum of two years (mean 6.3, range 2 to 14.4). The patients presented difficult management problems, having undergone an average of two previous operations per joint; 22 joints had suffered prior complications; 18 had less than 50 degrees of flexion and six were flail. One of three versions of the Coonrad prosthesis was employed in all. During the follow-up period, 10 patients underwent 14 revision procedures for aseptic loosening; 38 elbows are currently without progressive radiolucent lines. In two patients an elbow had to be resected, one for deep infection and the other for bone resorption following a foreign-body reaction to titanium. The current design of the Coonrad prosthesis offers a reliable option for the treatment of post-traumatic arthritis but should be used only in carefully selected patients over the age of 60 years.
The anatomy of the cubital tunnel and its relationship to ulnar nerve compression is not well documented. In 27 cadaver elbows the proximal edge of the roof of the cubital tunnel was formed by a fibrous band that we call the cubital tunnel retinaculum (CTR). The band is about 4 mm wide, extending from the medial epicondyle to the olecranon, and perpendicular to the flexor carpi ulnaris aponeurosis. Variations in the CTR were classified into four types. In type 0 (n = 1) the CTR was absent. In type Ia (n = 17), the retinaculum was lax in extension and taut in full flexion. In type Ib (n = 6) it was tight in positions short of full flexion (90 degrees to 120 degrees). In type II (n = 3) it was replaced by a muscle, the anconeus epitrochlearis. The CTR appears to be a remnant of the anconeus epitrochlearis muscle and its function is to hold the ulnar nerve in position. Variations in the anatomy of the CTR may explain certain types of ulnar neuropathy. Its absence (type 0 CTR) permits ulnar nerve displacement. Type Ia is normal and does not cause ulnar neuropathy. Type Ib can cause dynamic nerve compression with elbow flexion. Type II may be associated with static compression due to the bulk of the anconeus epitrochlearis muscle.
We report the results of conservative treatment of stage III and stage IV avascular necrosis of bone (AVN) affecting the hip or knee in renal transplant patients. Twenty-nine patients were followed for a mean period of five years. Conservative management was successful in controlling symptoms in 40% of those with AVN of the hip and in 70% of those with AVN of the knee. Knowledge of the natural history of AVN is important because of the long survival times after renal transplantation.
We made a prospective longitudinal clinical and radiological study of 18 children diagnosed as having dysplasia epiphysealis capitis femoris. Half the cases were bilateral. Boys were affected five times more often than girls. There were no symptoms or clinical signs in most but some of the bilateral cases had an inconsistent waddling gait. The imaging studies suggest that the cartilaginous proximal femoral epiphysis is hypoplastic, with delayed appearance of single or multiple ossification centres. Progressive improvement occurred and at an average age of five years and six months, there was complete fusion of all the ossific nuclei and normal density and texture of the epiphyseal bone. The end result was a round epiphysis with a slightly diminished height. The dysplasia is attributed to focal hypoplasia of the proximal femoral epiphysis.
Thirty-two dysplastic hips with secondary osteoarthritis, in 28 patients aged 18 to 42 years, were treated by combined intertrochanteric and Chiari osteotomy. They were followed up for 2.5 to 10 years. Pain was the main presenting symptom in all the patients. The indication for surgery was based on the severity of disease with respect to congruency, secondary degenerative change and degree of dysplasia. The average pre-operative Harris hip score was 47.7 and the majority had severe dysplasia with degenerative changes. On final review the average score was 88. The radiographic appearances of degenerative arthritis regressed in 72% of hips and dysplasia was improved in all cases. The results of this conservative form of surgery are better in hips with less severe dysplasia and mild secondary degenerative change.
A review of 77 neonates who presented with congenital talipes equinovarus over a seven-year period revealed an increase in the condition amongst babies born in the winter quarter. This finding was particularly apparent among the less severe cases of club-foot. Possible reasons for this seasonal variation are discussed.
We used ultrasonography to examine 36 children suffering from transient synovitis and 12 children with early Perthes' disease. Widening of the joint space was revealed by ultrasonography in all affected hips with either disease. In the patients with transient synovitis, capsular distension was attributed to synovial effusion, while in the patients with Perthes' disease it was produced by thickening of the synovial membrane. Neither capsular distension nor thickening of the joint cartilage was seen in the contralateral normal hip in the patients with transient synovitis, but they were common in early Perthes' disease. Ultrasonography may provide significant diagnostic clues to differentiate early Perthes' from transient synovitis.
We report four children aged two to nine years with traumatic tears of the transverse ligament of the atlas and atlanto-axial subluxation. This is extremely rare in this age group since trauma usually causes a skeletal rather than a ligamentous injury. The injuries resulted from falls or motor vehicle accidents, with considerable delay in diagnosis. Flexion radiographs showed atlas-dens intervals (ADI) of 6, 7, 8 and 13 mm; all four patients were treated by posterior fusion at C1-C2 after the failure of conservative treatment. In one child with quadriparesis and a fixed ADI of 13 mm, transoral anterior resection of the odontoid was performed before the fusion. Diagnosis of this traumatic lesion requires a high level of suspicion. Conservative treatment is likely to fail; surgical stabilisation is indicated.
Thirty-three patients with reflex sympathetic dystrophy were studied prospectively to ascertain the pressure-pain threshold of affected and unaffected limbs. The affected side had a lower threshold which was found to be statistically significant. In all 18 patients with upper limb involvement, the pain threshold was reduced on the affected side, but this applied to only 11 of the 15 with leg involvement. This difference may be because patients with lower limb symptoms had been referred later in the course of the syndrome. We showed by repeated tests that after an average of 49 days there was a slow return to normality. The estimation of pressure-pain thresholds may help in the earlier diagnosis of reflex sympathetic dystrophy.
The articular surface of the humeral head is usually described as facing posteromedially, making an angle of between 16 degrees and 35 degrees with the transepicondylar plane. At hemiarthroplasty the articular surface also appears to be offset posteriorly with respect to the humeral shaft. Coracoid impingement may occur if this offset is not accommodated. An analysis was made of 29 cadaveric humeri using an industrial co-ordinate measuring machine. The position of the centre of the head was defined with respect to the humeral shaft and transepicondylar plane. The humeral articular surface was found to be retroverted by 21.4 degrees and its centre offset posteriorly by 4.7 mm. Previous interpretation of retroversion did not take into account the posterior displacement, and this may be of importance in improving future prosthetic design.
We reviewed 19 patients treated for upper arm fractures using Seidel's locking nail system, which allows for early function after operation. The overall results were good with no cases of pseudarthrosis, infection or radial nerve palsy. All the patients regained full shoulder movements with no evidence of rotator cuff lesions.
Diaphyseal fractures of the tibia in 80 patients were treated by external skeletal fixation using a unilateral frame, either in a fixed mode or in a mode which allowed the application of a small amount of predominantly axial micromovement. Patients were allocated to each regime by random selection. Fracture healing was assessed clinically, radiologically and by measurement of the mechanical stiffness of the fracture. Both clinical and mechanical healing were enhanced in the group subjected to micromovement, compared to those treated with frames in a fixed mode possessing an overall stiffness similar to that of others in common clinical use. The differences in healing time were statistically significant and independently related to the treatment method. There was no difference in complication rates between treatment groups.
We describe a simple method of inserting the distal screws in a locked femoral nail. The method requires no aiming device and no assistant. The only equipment needed is a 3 mm Kirschner wire and an air drill.
We reviewed 129 patients with subcutaneous sarcoma diagnosed from 1964 to the end of 1985 in a population-based series of sarcoma cases from southern Sweden. The annual incidence was 0.4 per 100,000, comprising 32% of all soft-tissue sarcomas of the extremities or the trunk wall. Compared to deep-seated sarcomas, subcutaneous tumours were half the size at diagnosis, more common in the lower leg and foot, more often malignant fibrous histiocytoma, and of a lower grade of malignancy. None of the low-grade and only 7% of the high-grade tumours recurred locally after wide local excision without radiotherapy. The cumulative five-year survival for all 129 patients was 80%. Multivariate analysis identified only high grade of malignancy and the size of the tumour (greater than 5 cm) as independent prognostic factors. We conclude that systemic or local adjuvant therapy is not generally indicated for subcutaneous sarcoma because of the good prognosis and low local recurrence rate after wide excision.
We reviewed ten patients with metastatic carcinoma and impending pathological fractures of the subtrochanteric region of the femur who had prophylactic insertion of the Russell-Taylor reconstruction nail. There were no operative complications or long-term mechanical failures. This reconstruction nail has some technical and biomechanical advantages over other implants and is ideal for the management of such cases.
We reviewed 46 leg-shortening operations (37 femoral and nine tibial), performed by different methods, to assess the incidence of complications and permanent disability. Shortening of as much as 7.5 cm in the femur and 5 cm in the tibia was achieved in men of normal height without any loss of function. Complications were seen with all surgical techniques despite the use of modern implants. Most problems arose from inadequate stabilisation of the osteotomy. The most reliable method of femoral shortening was open subtrochanteric osteotomy with preservation of the isthmus, and fixation with an intramedullary nail locked at its proximal end. In tibial shortening, bone excision should be at the level of the flare in the lower diaphysis in order to achieve reliable bone healing. Simple intramedullary nail fixation should be supplemented with a long-leg cast for six weeks or the nail should be locked at both ends to prevent postoperative distraction or rotation.
We recorded inter- and intra-observer variations in the classification of ankle fractures by the Lauge Hansen and Weber systems. Radiographs of 94 patients were classified independently by four observers. The observer variation was calculated by kappa statistics, which corrects the obtained values for the agreement expected by chance. There was an acceptable level of agreement for the overall classification into both systems. For the staging of supination-adduction and supination-eversion fractures in the Lauge Hansen system the agreement was poor. The results indicate that future classification systems should be subject to reliability analysis before they are accepted.
We analysed the radiographs of 67 patients with displaced malleolar fractures treated by open reduction and internal fixation using absorbable polyglycolide rods. Seventeen patients developed a discharging inflammatory foreign-body reaction, a complication unique to these fixation devices. In 34 patients ovoid osteolytic foci, usually 5 to 10 mm in diameter, appeared within the implant channels six to 12 weeks after the operation. The same lesion occurred in 14 of the 17 patients who developed a foreign-body reaction, whereas only 20 out of the 50 patients with an uneventful course showed osteolytic areas (p less than 0.01). In patients with a foreign-body reaction the osteolytic foci tended to occur in the deepest parts of the implant channels. However, after one year the normal structure of the bone was restored.
Magnetic resonance imaging was performed on 28 patients with suspected calcaneal tendon injury prior to treatment. None of the patients were involved in competitive sports. All underwent clinical examination, some had had ultrasound or CT scans. We identified four types of lesions: type I, inflammatory reaction; type II, degenerative change; type III, incomplete rupture and type IV, complete rupture. Thirteen of the 28 patients underwent surgery and the diagnostic findings were verified. We recommend that type I, type II and type III lesions be managed conservatively, while type IV lesions should be operated in the young and active patient.