header advert
Results 1 - 3 of 3
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1058 - 1063
1 Nov 1999
Konttinen YT Kemppinen P Li TF Waris E Pihlajamäki H Sorsa T Takagi M Santavirta S Schultz GS Humphreys-Beher MG

We studied the presence of anabolic growth factors in human herniated intervertebral discs (IVD) using a reverse transcriptase-polymerase chain reaction (RT-PCR) and immunohistochemistry. Messenger RNA (mRNA) was isolated from the nucleus pulposus using oligo (dT)25 superparamagnetic beads and probing with gene-specific primers in RT-PCR.

mRNA coding for TGF-α (3/10), EGF (0/10), TGF-β1 (0/10) and TGF-β3 (2/10) or the EGF receptor (EGF-R; 0/10) and TGF-β type-II receptor (0/10) was found only occasionally. Beta-actin was always present and positive sample controls confirmed the validity of the RT-PCR assay. These RT-PCR findings were confirmed using immunohistochemical staining of EGF and TFG-β, whereas TGF-α protein was always found associated with discocytes.

We conclude that the nucleus pulposus of the herniated IVD is vulnerable to proteolytic degradation and depletion of proteoglycans due to the lack and/or low production of anabolic growth factors/receptors which could increase the local synthesis of the extracellular matrix.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 180 - 180
1 Jan 1998
PIHLAJAMÄKI H


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 183 - 189
1 Mar 1997
Pihlajamäki H Myllynen P Böstman O

We analysed the complications encountered in 102 consecutive patients who had posterolateral lumbosacral fusion performed with transpedicular screw and rod fixation for non-traumatic disorders after a minimum of two years. Of these, 40 had spondylolysis and spondylolisthesis, 42 a degenerative disorder, 14 instability after previous laminectomy and decompression, and six pain after nonunion of previous attempts at spinal fusion without internal fixation. There were 75 multilevel and 27 single-level fusions.

There were 76 individual complications in 48 patients, and none in the other 54. The complications seen were screw misplacement, coupling failure of the device, wound infection, nonunion, permanent neural injury, and loosening, bending and breakage of screws. Screw breakage or loosening was more common in patients with multilevel fusions (p < 0.001). Screws of 5 mm diameter should not be used for sacral fixation.

Forty-six patients had at least one further operation for one or several complications, including 20 fusion procedures for nonunion. The high incidence of complications is a disadvantage of this technically-demanding method.