header advert
Results 1 - 4 of 4
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1545 - 1550
1 Nov 2007
Koslowsky TC Mader K Dargel J Koebke J Hellmich M Pennig D

We have evaluated four different fixation techniques for the reconstruction of a standard Mason type-III fracture of the radial head in a sawbone model. The outcome measurements were the quality of the reduction, and stability.

A total of 96 fractures was created. Six surgeons were involved in the study and each reconstructed 16 fractures with 1.6 mm fine-threaded wires (Fragment Fixation System (FFS)), T-miniplates, 2 mm miniscrews and 2 mm Kirschner (K-) wires; four fractures being allocated to each method using a standard reconstruction procedure.

The quality of the reduction was measured after definitive fixation. Biomechanical testing was performed using a transverse plane shear load in two directions to the implants (parallel and perpendicular) with respect to ultimate failure load and displacement at 50 N.

A significantly better quality of reduction was achieved using the FFS wires (Tukey’s post hoc tests, p < 0.001) than with the other devices with a mean step in the articular surface and the radial neck of 1.04 mm (sd 0.96) for the FFS, 4.25 mm (sd 1.29) for the miniplates, 2.21 mm (sd 1.06) for the miniscrews and 2.54 mm (sd 0.98) for the K-wires. The quality of reduction was similar for K-wires and miniscrews, but poor for miniplates.

The ultimate failure load was similar for the FFS wires (parallel, 196.8 N (sd 46.8), perpendicular, 212.5 N (sd 25.6)), miniscrews (parallel, 211.8 N (sd 47.9), perpendicular, 208.0 N (sd 65.9)) and K-wires (parallel, 200.4 N (sd 54.5), perpendicular, 165.2 N (sd 37.9)), but significantly worse (Tukey’s post hoc tests, p < 0.001) for the miniplates (parallel, 101.6 N (sd 43.1), perpendicular, 122.7 N (sd 40.7)). There was a significant difference in the displacement at 50 N for the miniplate (parallel, 4.8 mm (sd 2.8), perpendicular, 4.8 mm (sd 1.7)) vs FFS (parallel, 2.1 mm (sd 0.8), perpendicular, 1.9 mm (sd 0.7)), miniscrews (parallel, 1.8 mm (sd 0.5), perpendicular, 2.3 mm (sd 0.8)) and K-wires (parallel, 2.2 mm (sd 1.8), perpendicular, 2.4 mm (sd 0.7; Tukey’s post hoc tests, p < 0.001)).

The fixation of a standard Mason type-III fracture in a sawbone model using the FFS system provides a better quality of reduction than that when using conventional techniques. There was a significantly better stability using FFS implants, miniscrews and K-wires than when using miniplates.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1016 - 1018
1 Sep 2003
Mader K Gausepohl T Wolfgarten B Pennig D

Our aim in this prospective study was to evaluate a minimally invasive technique for percutaneous arthrodesis of the small joints in the hand. Thirteen arthrodeses were undertaken in 11 patients, eight women and three men. After the percutaneous removal of articular cartilage, the bony surfaces were aligned in a predetermined position and stabilised using a percutaneous screw system. The mean follow-up was 38.6 months (36 to 56). Bony union was achieved in 12 cases (ten patients) between nine and 12 weeks after surgery. In one patient a second operation was required to obtain union and another developed a painless nonunion after premature removal of the implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 438 - 440
1 May 1997
Pennig D Gladbach B Majchrowski W

A young woman sustained disruption of the anterior pelvic ring with bony avulsion of the symphysis pubis during a spontaneous delivery. Anterior external fixation allowed a full functional recovery.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 886 - 888
1 Sep 1990
Pennig D Brug E

Posterior spinal instrumentation with the placement of intrapedicular implants has become an important technique. We have designed a hand-held target device to facilitate the open or percutaneous location and penetration of the thoracolumbar pedicles. A cylindrical pin guide incorporates two metal rings and can be moved under image intensifier control until the rings are superimposed to show correct alignment. The radiation dosage for the surgeon is minimal; the device allowed accurate placement of 106 consecutive pedicle screws.