header advert
Results 1 - 5 of 5
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 389 - 392
1 Apr 2003
Misra AN Hussain MRA Fiddian NJ Newton G

We randomised 129 knees which were to be replaced using a standard posterior-cruciate-ligament (PCL)-retaining cemented total knee replacement into two groups. In one the PCL was retained in the normal way and in the other it was resected. They were well matched, with a predominance of women, and a mean age of 67 years.

There was no statistically significant difference in the Hospital for Special Surgery scores at a mean of 57 months (56 to 60) between the two groups although 21 patients (24 knees) were lost to follow-up. Relief from pain, correction of deformity, range of movement, stability and strength were comparable in both. Radiological assessment showed femoral rollback in approximately 20% of knees with a slightly higher incidence in the PCL-resected group. There was no significant loosening detected in either group at review at two years.

At five years, one knee in the PCL-retained group had been revised because of infection and one patient in each group was awaiting revision for loosening.

Our findings have shown no significant difference in the five-year results for a PCL-retaining total knee replacement if the PCL is excised or preserved. This suggests two important points. First, the PCL is not functional in most patients with a total knee replacement even when retained. Secondly, patients with an excised PCL show a good result with a PCL-retaining implant, thereby questioning the need for a posterior stabilised design in such a situation.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 751 - 756
1 Sep 1991
Sambatakakis A Wilton T Newton G

We report on the radiological findings in a series of 871 consecutive primary condylar knee replacements followed up for an average of four years. A new radiological sign has been identified, consisting of a smoothly tapering wedge of cement visible beneath the horizontal portion of the tibial component on the anteroposterior radiograph. This was found in 25.4% of our cases and appears to indicate a persistent soft-tissue imbalance following condylar arthroplasty of the knee. The cement-wedge sign was associated with a highly significant increase in radiolucent lines at the tibial cement-bone interface.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 707 - 708
1 Sep 1991
Newton G


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 588 - 590
1 Aug 1989
Fern E Stewart H Newton G

We report the use of long curved Kuntscher nails to maintain stability during arthrodesis of nine infected and five uninfected failures of total knee replacement. The curvature of the nail helps positioning and avoids the need for cortical perforation. A single-stage operation was possible in most cases. Union rates are comparable with those of other series and even patients with delayed union have satisfactory function.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 180 - 183
1 May 1980
Waugh W Newton G Tew M

In a consecutive series of 87 operations for knee replacement prospective observations were made of the pattern of articular destruction in the form of a triangle of erosion or osteophyte formation, which is seen on the medial femoral condyle, sometimes with an associated strip on the lateral femoral condyle. These areas represent the surfaces which are normally in contact with the anterior horns of the menisci when the knee is fully extended. The lesions in question were found only in association with a flexion contracture in 84 out of the 87 cases.