header advert
Results 1 - 5 of 5
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 744 - 749
1 Sep 1993
Kershaw C Ware H Pattinson R Fixsen J

We report a review of 33 hips (32 patients) which had required repeat open reduction for congenital dislocation of the hip. They were followed up for a mean of 76 months (36 to 132). Factors predisposing to failure of the initial open reduction were simultaneous femoral or pelvic osteotomy, inadequate inferior capsular release, and inadequate capsulorrhaphy. Avascular necrosis had developed in more than half the hips, usually before the final open reduction. At review, 11 of the hips (one-third) were in Severin grade 3 or worse; five had significant symptoms and only ten were asymptomatic and radiographically normal. Once redisplacement has occurred after primary open reduction, attempts to reduce the head by closed means or by pelvic or femoral osteotomy are usually unsuccessful and a further open reduction is necessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 564 - 568
1 Jul 1991
Kershaw C Atkins R Dodd C Bulstrode C

The results of 276 cemented revision total hip arthroplasties performed for aseptic failure between 1977 and 1986 have been reviewed. The mean time between revision and review was 75 months (range 30 to 144). Of 220 cases available for review, 159 were assessed clinically and radiographically, and 32 by postal questionnaire. Eighteen hips required further revision, 12 for loosening, two for sepsis, two for persistent pain, and one each for fracture and recurrent dislocation. A further six hips were radiologically and symptomatically loose. Pain was mild or absent in 83%. Over half were able to walk a mile or more; 70% flexed more than 70 degrees; 15% had a flexion deformity, but in only 7% was this more than 10 degrees. The mean Harris hip score was 74. Survival at five years was 95% and at 10 years, 77%.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 692 - 701
1 Nov 1988
Goodfellow J Kershaw C Benson M O'Connor J

The Oxford Knee, a resurfacing prosthesis with a meniscal bearing, can be used for either bicompartmental or unicompartmental arthritis. The first 103 unicompartmental cases are presented at a mean time since operation of 36 months (range 21 to 56 months). In those cases with surviving arthroplasties, pain was relieved in 96%. The full range of pre-operative flexion was maintained and flexion deformity was improved from a mean of 6.7 to 5.4 degrees. Stability and alignment were restored to normal in nearly all the knees. Absence of the anterior cruciate ligament was associated with a significantly greater incidence of failure. Six failures occurred in 37 knees lacking a normal anterior cruciate ligament (16.2%); three occurred in 63 knees with a normal anterior cruciate ligament (4.8%) (p less than 0.02). Criteria for the future selection of patients have been deduced from our experience. The operation is recommended for knees with severe unicompartmental osteoarthritis in which all the ligaments are still intact.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 491 - 491
1 May 1988
Thomas W Kershaw C


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 89 - 93
1 Jan 1988
Kershaw C Themen A

The results of 132 Attenborough total knee replacements after a follow-up period of from four to 10 years are presented. Long-term relief of pain and improvement in stability and walking distance were maintained in over two-thirds. The cumulative survivorship with the prosthesis in situ, little or no pain and no radiological loosening was 65% at six years. Problems with wound healing were common, and there was a complication rate of 20% in primary replacements, including a deep-infection rate of 3.5%. Almost 20% of the prostheses needed revision because of aseptic loosening, and there is evidence of radiological and clinical loosening in a further 7.5%.