The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 704 - 709
1 May 2005
Chen TH Chen WM Huang CK

We reviewed 29 patients who had undergone intercalary resection for malignant tumours. Of these, 14 had received segmental allograft reconstruction and 15 extracorporeally-irradiated autograft.

At a mean follow-up of 71 months (24 to 132), 20 were free from disease, five had died and four were alive with pulmonary metastases. Two patients, one with an allograft and one with an irradiated autograft, had a local recurrence. Reconstruction with extracorporeally-irradiated autograft has a significantly lower rate of nonunion (7% vs 43%, p = 0.031) but an insignificantly higher rate of fracture (20% vs 14%, p = 0.535) than that with segmental allograft. Using the Enneking functional evaluation system, the mean postoperative score for the patients without local recurrence was 87% (80% to 96%) and was similar in both groups.

Extracorporeally-irradiated autograft could be an acceptable alternative for reconstruction after intercalary resection, especially in countries where it is difficult to obtain allografts.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1156 - 1161
1 Nov 2002
Chen WM Chen TH Huang CK Chiang CC Lo WH

Autogenous bone graft which has been either autoclaved or irradiated is commonly used in oriental countries as an alternative to allograft. We started to use the technique of extracorporeal irradiation of the resected specimen and reimplantation (ECIR) in 1991. There was, however, a high incidence of fracture of the irradiated bone and loss of articular cartilage. In an attempt to reduce these complications, we combined the irradiated autograft with a conventional arthroplasty. Between 1995 and 1998, 14 patients underwent limb salvage by this method. Seven had an osteosarcoma, two bony metastases, three a chondrosarcoma, one a malignant fibrous histiocytoma, and one a leiomyosarcoma. Ten tumours were located in the proximal femur, two in the proximal humerus, and two in the distal femur.

One patient who had a solitary metastasis in the proximal part of the left femur died from lung metastases 13 months after operation. The remaining 13 patients were alive and without evidence of local recurrence or distant metastases at a mean follow-up of 43 months (28 to 72). Postoperative palsy of the sciatic nerve occurred in one patient, but no complications such as wound infection, fracture, or nonunion were seen. All host-irradiated bone junctions healed uneventfully within eight months. Using the Enneking functional evaluation system, the mean postoperative score for all 14 patients was 80% (57 to 93).

The use of irradiated autograft prosthesis composites reduces the complications of ECIR and gives good functional results. It may be a good alternative in limb-salvage surgery, especially in countries where it is difficult to obtain allografts.