header advert
Results 1 - 3 of 3
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 521 - 529
1 May 2002
Böhm P Huber J

The skeleton is the most common site to be affected by metastatic cancer. The place of surgical treatment and of different techniques of reconstruction has not been clearly defined.

We have studied the rate of survival of 94 patients and the results of the surgical treatment of 91 metastases of the limbs and pelvis, and 18 of the spine. Variables included the different primary tumours, the metastatic load at the time of operation, the surgical margin, and the different techniques of reconstruction.

The survival rate was 0.54 at one year and 0.27 at three years. Absence of visceral metastases and of a pathological fracture, a time interval of more than three years between the diagnosis of cancer and that of the first skeletal metastasis, thyroid carcinoma, prostate carcinoma, renal-cell carcinoma, breast cancer, and plasmacytoma were positive variables with regard to survival. The metastatic load of the skeleton and the surgical margin were not of significant influence. In tumours of the limbs and pelvis, the local failure rate was 0% after biological reconstruction (10), 3.6% after cemented or uncemented osteosynthesis (28) and 1.8% after prosthetic replacement (53). The local failure rate after stabilisation of the spine (18) was 16.6%. There was local recurrence in seven patients (6.4%), and in four of these the primary tumour was a renal-cell carcinoma. The local recurrence rate was 0% after extralesional (24) and 8.2% after intralesional resection (85).

Improvements in the oncological management of patients with primary and metastatic disease have resulted in an increased survival rate. In order to avoid additional surgery, it is essential to consider the expected time of survival of the reconstruction and, in bony metastases with a potentially poor response to radiotherapy, the surgical margin.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 396 - 403
1 May 1998
Böhm P Bösche R

We reviewed 264 consecutive primary total hip replacements in 244 patients in which the Harris-Galante I porous-coated acetabular component had been used. The mean follow-up was 95 months (69 to 132). In 221 arthroplasties a 32 mm ceramic head had been used, and in the other 43 one of cobalt-chrome alloy. There were 124 women and 120 men with a mean age at operation of 56.8 years (21 to 83).

Survival analysis of the acetabular components was performed using the following definitions of failure: 1) infection; 2) removal because of aseptic loosening; 3) removal for any cause; and 4) a worst-case analysis including removal of the cup or infection or loss to follow-up.

Two well-fixed cups had been removed because of deep infection and three, similarly sound cups had been exchanged at the time of femoral revision. None of the acetabular components had required revision for aseptic loosening. After 11 years survival was 97.7% using the worst-case criterion. Radiological analysis of 187 acetabular components at a mean of 82 months (41 to 132) revealed no case of aseptic loosening. Pelvic osteolysis was seen in only one patient, but was not progressive and showed signs of regression.

The results using these acetabular components are encouraging but the need for regular follow-up remains since complications such as significant wear of the liner, massive osteolysis of the pelvis, aseptic loosening and late infection may increase in the second decade.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 302 - 309
1 Mar 1998
Böhm P Holy T

The Blauth prosthesis is a hinged total knee replacement. We have evaluated 422 consecutive primary total knee arthroplasties using this design in 330 patients with a maximum follow-up of 20 years (mean 6). The mean age of the patients at the time of operation was 70 years (29 to 87).

Using endpoints of infection, removal because of aseptic loosening, removal for any cause, and the worst case as definitions of failure, the cumulative rates of survival at 20 years were 93.6%, 96.0%, 94.4% and 86.8%, respectively. The cumulative rate of survival of the patients themselves was 14.4% (24% in patients with osteoarthritis and 9% in these with rheumatoid arthritis) after 20 years.

Our survivorship analysis shows that hinged knee prostheses, when they are biomechanically well designed, can yield a satisfactory long-term outcome, similar to those of the best prostheses of the resurfacing type. Hinged knee prostheses continue to be of value in patients with severe deformity or instability of the knee.