We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year.Aims
Methods
Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR. We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected.Aims
Methods
We present a review of litigation claims relating
to foot and ankle surgery in the NHS in England during the 17-year period
between 1995 and 2012. A freedom of information request was made to obtain data from
the NHS litigation authority (NHSLA) relating to orthopaedic claims,
and the foot and ankle claims were reviewed. During this period of time, a total of 10 273 orthopaedic claims
were made, of which 1294 (12.6%) were related to the foot and ankle.
1036 were closed, which comprised of 1104 specific complaints. Analysis
was performed using the complaints as the denominator. The cost
of settling these claims was more than £36 million. There were 372 complaints (33.7%) involving the ankle, of which
273 (73.4%) were related to trauma. Conditions affecting the first
ray accounted for 236 (21.4%), of which 232 (98.3%) concerned elective
practice. Overall, claims due to diagnostic errors accounted for
210 (19.0%) complaints, 208 (18.8%) from alleged incompetent surgery
and 149 (13.5%) from alleged mismanagement. Our findings show that the incorrect, delayed or missed diagnosis
of conditions affecting the foot and ankle is a key area for improvement,
especially in trauma practice. Cite this article: