header advert
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1146 - 1151
1 Nov 2004
Koivikko MP Kiuru MJ Koskinen SK Myllynen P Santavirta S Kivisaari L

In type-II fractures of the odontoid process, the treatment is either conservative in a halo vest or primary surgical stabilisation. Since nonunion, requiring prolonged immobilisation or late surgery, is common in patients treated in a halo vest, the identification of those in whom this treatment is likely to fail is important.

We reviewed the data of 69 patients with acute type-II fractures of the odontoid process treated in a halo vest. The mean follow-up was 12 months. Conservative treatment was successful, resulting in bony union in 32 (46%) patients. Anterior dislocation, gender and age were unrelated to nonunion. However, nonunion did correlate with a fracture gap (> 1 mm), posterior displacement (> 5 mm), delayed start of treatment (> 4 days) and posterior redisplacement (> 2 mm).

We conclude that patients presenting with these risk factors are unlikely to achieve bony union by treatment in a halo vest. They deserve careful attention during the follow-up period and should also be considered as candidates for primary surgical stabilisation.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 183 - 189
1 Mar 1997
Pihlajamäki H Myllynen P Böstman O

We analysed the complications encountered in 102 consecutive patients who had posterolateral lumbosacral fusion performed with transpedicular screw and rod fixation for non-traumatic disorders after a minimum of two years. Of these, 40 had spondylolysis and spondylolisthesis, 42 a degenerative disorder, 14 instability after previous laminectomy and decompression, and six pain after nonunion of previous attempts at spinal fusion without internal fixation. There were 75 multilevel and 27 single-level fusions.

There were 76 individual complications in 48 patients, and none in the other 54. The complications seen were screw misplacement, coupling failure of the device, wound infection, nonunion, permanent neural injury, and loosening, bending and breakage of screws. Screw breakage or loosening was more common in patients with multilevel fusions (p < 0.001). Screws of 5 mm diameter should not be used for sacral fixation.

Forty-six patients had at least one further operation for one or several complications, including 20 fusion procedures for nonunion. The high incidence of complications is a disadvantage of this technically-demanding method.