After cemented total hip arthroplasty (THA) there may be failure at either the cement-stem or the cement-bone interface. This results from the occurrence of abnormally high shear and compressive stresses within the cement and excessive relative micromovement. We therefore evaluated micromovement and stress at the cement-bone and cement-stem interfaces for a titanium and a chromium-cobalt stem. The behaviour of both implants was similar and no substantial differences were found in the size and distribution of micromovement on either interface with respect to the stiffness of the stem. Micromovement was minimal with a cement mantle 3 to 4 mm thick but then increased with greater thickness of the cement. Abnormally high micromovement occurred when the cement was thinner than 2 mm and the stem was made of titanium. The relative decrease in surface roughness augmented slipping but decreased debonding at the cement-bone interface. Shear stress at this site did not vary significantly for the different coefficients of cement-bone friction while compressive and hoop stresses within the cement increased slightly.
The optimal regime of antithrombotic prophylaxis for patients undergoing total knee arthroplasty (TKA) has not been established. Many surgeons employ intermittent pneumatic compression while others use low-molecular-weight heparins (LMWH) which were primarily developed for total hip arthroplasty. We compared the efficacy and safety of these two techniques in a randomised study with blinded assessment of the endpoint by phlebography. We randomised 130 patients, scheduled for elective TKA, to receive one daily subcutaneous injection of nadroparin calcium (dosage adapted to body-weight) or continuous intermittent pneumatic compression of the foot by means of the arteriovenous impulse system. A total of 108 patients (60 in the LMWH group and 48 in the mechanical prophylaxis group) had phlebography eight to 12 days after surgery. Of the 47 with deep-vein thrombosis, 16 had received LMWH (26.7%, 95% CI 16.1 to 39.7) and 31, mechanical prophylaxis (64.6%, 95% CI 49.5 to 77.8). The difference between the two groups was highly significant (p <
0.001). Only one patient in the LMWH group had severe bleeding. We conclude that one daily subcutaneous injection of calcium nadroparin in a fixed, weight-adjusted dosage scheme is superior to intermittent pneumatic compression of the foot for thromboprophylaxis after TKA. The LMWH scheme was also safe.
Biological fixation of cementless femoral implants requires primary stability by optimal fit in the proximal femur. The anatomy of the bone must then be known precisely. We analysed in vitro the accuracy of bone measurements of 32 femurs and compared the dimensions obtained from radiographs and CT scans with the true anatomical dimensions. Standard radiographs gave only a rough approximation of femoral geometry (mean difference: 2.4 +/- 1.4 mm) insufficiently accurate to allow selection of the best fitting prosthesis from a range of sizes and altogether inadequate to design a custom-made prosthesis. CT scans give greater accuracy (mean difference: 0.8 +/- 0.7 mm) in our experimental conditions, but in clinical practice additional sources of error exist.