The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 847 - 852
1 Nov 1995
Massin P Duparc J

We retrospectively reviewed 56 patients (71 hips) treated by total replacement for severe disability after pelvic irradiation. Symptoms were associated with various radiological lesions due to irradiation, including atraumatic femoral-neck fracture, osteonecrosis of the femoral head or of the acetabulum, and radiation osteitis of the whole pelvis. From 1970 to 1982 we used standard cemented components in 49 hips and had a high rate of acetabular loosening (52%) at a mean follow-up of 69 months. This was probably due to the mechanical insufficiency of irradiated periacetabular bone. From 1983 to 1990 we routinely used acetabular reinforcement rings. The rate of aseptic acetabular loosening in 22 hips at a mean follow-up of 40 months was 19%, but there were two septic loosenings emphasising the risk of infection in these patients. When total replacement is required for an irradiated hip, we recommend reinforcement of the acetabulum using a metallic ring, but there is still an increased risk of infection and in difficult cases such as severe acetabular destruction or soft-tissue or vascular injuries, a Girdlestone procedure may be indicated.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 251 - 256
1 Mar 1992
Duparc J Massin P

We implanted 203 smooth-stemmed femoral components before January 1988. The femoral component used was anatomically shaped, fluted and made of titanium. Thirty-two hips were revised due to mid-thigh pain, and the femoral implant was found to be loose in all. In the 157 patients with a two-year follow-up, the Merle d'Aubigne and pain scores for completely cementless arthroplasties were similar to those for hybrid prostheses (cemented acetabular cup and cementless femoral stem). Of the 145 cases with two-year radiographic follow-up, 59 had extensive radiolucencies and 22 were unstable. The five-year cumulative survival rate was 77%. Implantation of this stem should be restricted to patients in whom cement fixation is contra-indicated.


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 3 | Pages 474 - 480
1 Aug 1961
Tubiana R Duparc J

In ten cases definitive loss of sensibility in an important territory of the hand has been treated by a hetero-digital, neurovascular skin island transfer. Operative technique and results obtained are reported. Although not enough patients have been treated to allow us to give precise indications for the procedure, two such indications clearly emerge: 1) the treatment of insensitive digits; 2) the reconstruction of the thumb or fingers. The procedure could probably be used elsewhere than in the hand.


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 1 | Pages 7 - 15
1 Feb 1961
Tubiana R Duparc J

1. The gravity of thrombo-embolic complications in orthopaedic and accident surgery has stimulated us, since 1951, to devise a means of prevention which comprises: a) the use of anticoagulants, the mode of administration of which has been determined by an experience of over 5,000 cases; and b) a method of selecting those patients most threatened by thromboembolism.