Advertisement for orthosearch.org.uk
Results 1 - 20 of 190
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 269 - 276
1 Mar 2023
Tay ML Monk AP Frampton CM Hooper GJ Young SW

Aims. Unicompartmental knee arthroplasty (UKA) has higher revision rates than total knee arthroplasty (TKA). As revision of UKA may be less technically demanding than revision TKA, UKA patients with poor functional outcomes may be more likely to be offered revision than TKA patients with similar outcomes. The aim of this study was to compare clinical thresholds for revisions between TKA and UKA using revision incidence and patient-reported outcomes, in a large, matched cohort at early, mid-, and late-term follow-up. Methods. Analyses were performed on propensity score-matched patient cohorts of TKAs and UKAs (2:1) registered in the New Zealand Joint Registry between 1 January 1999 and 31 December 2019 with an Oxford Knee Score (OKS) response at six months (n, TKA: 16,774; UKA: 8,387), five years (TKA: 6,718; UKA: 3,359), or ten years (TKA: 3,486; UKA: 1,743). Associations between OKS and revision within two years following the score were examined. Thresholds were compared using receiver operating characteristic analysis. Reasons for aseptic revision were compared using cumulative incidence with competing risk. Results. Fewer TKA patients with ‘poor’ outcomes (≤ 25) subsequently underwent revision compared with UKA at six months (5.1% vs 19.6%; p < 0.001), five years (4.3% vs 12.5%; p < 0.001), and ten years (6.4% vs 15.0%; p = 0.024). Compared with TKA, the relative risk for UKA was 2.5-times higher for ‘unknown’ reasons, bearing dislocations, and disease progression. Conclusion. Compared with TKA, more UKA patients with poor outcomes underwent revision from early to long-term follow-up, and were more likely to undergo revision for ‘unknown’ reasons, which suggest a lower clinical threshold for UKA. For UKA, revision risk was higher for bearing dislocations and disease progression. There is supporting evidence that the higher revision UKA rates are associated with lower clinical thresholds for revision and additional modes of failure. Cite this article: Bone Joint J 2023;105-B(3):269–276


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 91 - 95
1 Jun 2020
Johnson, Jr. WB Engh, Jr. CA Parks NL Hamilton WG Ho PH Fricka KB

Aims. It has been hypothesized that a unicompartmental knee arthroplasty (UKA) is more likely to be revised than a total knee arthroplasty (TKA) because conversion surgery to a primary TKA is a less complicated procedure. The purpose of this study was to determine if there is a lower threshold for revising a UKA compared with TKA based on Oxford Knee Scores (OKSs) and range of movement (ROM) at the time of revision. Methods. We retrospectively reviewed 619 aseptic revision cases performed between December 1998 and October 2018. This included 138 UKAs that underwent conversion to TKA and 481 initial TKA revisions. Age, body mass index (BMI), time in situ, OKS, and ROM were available for all patients. Results. There were no differences between the two groups based on demographics or time to revision. The top reasons for aseptic TKA revision were loosening in 212 (44%), instability in 88 (18%), and wear in 69 (14%). UKA revision diagnoses were primarily for loosening in 50 (36%), progression of osteoarthritis (OA) in 50 (36%), and wear in 17 (12%). Out of a maximum 48 points, the mean OKS of the UKAs before revision was 23 (SD 9.3), which was significantly higher than the TKAs at 19.2 (SD 9.8; p < 0.001). UKA patients scored statistically better on nine of the 12 individual OKS questions. The UKA cases also had a larger pre-revision mean ROM (114°, SD 14.3°) than TKAs (98°, SD 25°) ; p < 0.001). Conclusion. At revision, the mean UKA OKSs and ROM were significantly better than those of TKA cases. This study suggests that at our institution there is a difference in preoperative OKS between UKA and TKA at the time of revision, demonstrating a revision bias. Cite this article: Bone Joint J 2020;102-B(6 Supple A):91–95


Aims. To identify the responsiveness, minimal clinically important difference (MCID), minimal clinical important change (MIC), and patient-acceptable symptom state (PASS) thresholds in the 36-item Short Form Health Survey questionnaire (SF-36) (v2) for each of the eight dimensions and the total score following total knee arthroplasty (TKA). Methods. There were 3,321 patients undergoing primary TKA with preoperative and one-year postoperative SF-36 scores. At one-year patients were asked how satisfied they were and “How much did the knee arthroplasty surgery improve the quality of your life?”, which was graded as: great, moderate, little (n = 277), none (n = 98), or worse. Results. Physical function, role limitations due to physical problems (‘role physical’), bodily pain, and the total score SF-36 scores demonstrated the greatest effect sizes (> 0.9). The MCID for each of SF-36 dimensions ranged from 1.7 for role emotional to 6.4 for bodily pain. The MICs for a cohort of patients ranged from -1.0 for general health to 11.1 for bodily pain. The MICs for an individual patient were marginally greater (one to two points) compared to those for a cohort, and ranging from 0.0 for general and mental health to 13.5 for physical function. The lowest PASS score threshold was associated with physical function (> 34 points) whereas the greatest threshold (> 69 points) was associated with mental health. Conclusion. The SF-36 is a responsive tool, and the estimates for MCID, MIC, and PASS thresholds that can be used to power studies, assess whether there has been a meaningful change in patients’ health-related quality of life, and can be used as a marker of achieving patient satisfaction following TKA. Cite this article: Bone Joint Res 2022;11(7):477–483


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims. Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis). Methods. Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system. Results. At a mean follow-up of 90 months (64 to 130), only two out of 245 cases failed due to aseptic loosening. Intraoperative grading yielded mean scores of 1.87 (95% confidence interval (CI) 1.82 to 1.92) for the femur and 1.96 (95% CI 1.92 to 2.0) for the tibia. Only 3.7% of femoral and 1.7% of tibial reconstructions fell below the 1.5-point threshold, which included the two cases of aseptic loosening. Interobserver reliability for postoperative radiological grading was 0.97 for the femur and 0.85 for the tibia. Conclusion. A minimum score of 1.5 points for each skeletal segment appears to be a reasonable cut-off to define sufficient fixation in rTKA. There were no revisions for aseptic loosening at mid-term follow-up when this fixation threshold was achieved or exceeded. When assessing first-time revisions, this novel grading system has shown excellent intra- and interobserver reliability. Cite this article: Bone Joint J 2024;106-B(5):468–474


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 177 - 184
1 Jun 2021
Uvodich ME Dugdale EM Osmon DR Pagnano MW Berry DJ Abdel MP

Aims. It remains difficult to diagnose early postoperative periprosthetic joint infection (PJI) following total knee arthroplasty (TKA). We aimed to validate the optimal cutoff values of ESR, CRP, and synovial fluid analysis for detecting early postoperative PJI in a large series of primary TKAs. Methods. We retrospectively identified 27,066 primary TKAs performed between 2000 and 2019. Within 12 weeks, 169 patients (170 TKAs) had an aspiration. The patients were divided into two groups: those evaluated ≤ six weeks, or between six and 12 weeks postoperatively. The 2011 Musculoskeletal Infection Society (MSIS) criteria for PJI diagnosis in 22 TKAs. The mean follow-up was five years (two months to 17 years). The results were compared using medians and Mann-Whitney U tests and thresholds were analyzed using receiver operator characteristic curves. Results. Within six weeks, the median CRP (101 mg/l vs 35 mg/l; p = 0.011), synovial WBCs (58,295 cells/μl vs 2,121 cells/μl; p ≤ 0.001), percentage of synovial neutrophils (91% vs 71% (p < 0.001), and absolute synovial neutrophil count (ANC) (50,748 cells/μl vs 1,386 cells/μl (p < 0.001) were significantly higher in infected TKAs. Between six and 12 weeks, the median CRP (85 mg/l vs 5 mg/l (p < 0.001)), ESR (33 mm/hr vs 14 mm/hr (p = 0.015)), synovial WBCs (62,247 cells/μl vs 620 cells/μl (p < 0.001)), percentage of synovial neutrophils (93% vs 54% (p < 0.001)), and ANC (55,911 cells/μl vs 326 cells/μl (p < 0.001)) were also significantly higher in infected TKAs. Optimal thresholds at ≤ six weeks were: CRP ≥ 82 mg/l (sensitivity 70%, specificity 77%), synovial WBCs ≥ 8,676 cells/μl (83%, 90%), percentage of synovial neutrophils ≥ 88% (67%, 78%), and ANC ≥ 8,346 cells/μl (83%, 91%). Between six and 12 weeks, thresholds were: CRP ≥ 34 mg/l (90%, 93%), synovial WBCs ≥ 1,983 cells/μl (80%, 85%), percentage of synovial neutrophils ≥ 76% (80%, 81%), and ANC ≥ 1,684 cells/μl (80%, 87%). Conclusion. Early PJI after TKA should be suspected within six weeks if the CRP is ≥ 82 mg/l, synovial WBCs are ≥ 8,676 cells/μl, the percentage of synovial neutrophils is ≥ 88%, and/or the ANC is ≥ 8,346 cells/μl. Between six and 12 weeks, thresholds include a CRP of ≥ 34 mg/l, synovial WBC of ≥ 1,983 cells/μl, a percentage of synovial neutrophils of ≥ 76%, and/or an ANC of ≥ 1,684 cells/μl. Cite this article: Bone Joint J 2021;103-B(6 Supple A):177–184


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 38 - 45
1 Jan 2024
Leal J Mirza B Davies L Fletcher H Stokes J Cook JA Price A Beard DJ

Aims. The aim of this study was to estimate the incremental use of resources, costs, and quality of life outcomes associated with surgical reconstruction compared to rehabilitation for long-standing anterior cruciate ligament (ACL) injury in the NHS, and to estimate its cost-effectiveness. Methods. A total of 316 patients were recruited and randomly assigned to either surgical reconstruction or rehabilitation (physiotherapy but with subsequent reconstruction permitted if instability persisted after treatment). Healthcare resource use and health-related quality of life data (EuroQol five-dimension five-level health questionnaire) were collected in the trial at six, 12, and 18 months using self-reported questionnaires and medical records. Using intention-to-treat analysis, differences in costs, and quality-adjusted life years (QALYs) between treatment arms were estimated adjusting for baseline differences and following multiple imputation of missing data. The incremental cost-effectiveness ratio (ICER) was estimated as the difference in costs divided by the difference in QALYs between reconstruction and rehabilitation. Results. At 18 months, patients in the surgical reconstruction arm reported higher QALYs (0.052 (95% confidence interval (CI) -0.012 to 0.117); p = 0.177) and higher NHS costs (£1,017 (95% CI 557 to 1,476); p < 0.001) compared to rehabilitation. This resulted in an ICER of £19,346 per QALY with the probability of surgical reconstruction being cost-effective of 51% and 72% at a willingness-to-pay threshold of £20,000 and £30,000 per QALY, respectively. Conclusion. Surgical reconstruction as a management strategy for patients with long-standing ACL injury is more effective, but more expensive, at 18 months compared to rehabilitation management. In the UK setting, surgical reconstruction is cost-effective. Cite this article: Bone Joint J 2024;106-B(1):38–45


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1202 - 1208
1 Nov 2022
Klasan A Rice DA Kluger MT Borotkanics R McNair PJ Lewis GN Young SW

Aims. Despite new technologies for total knee arthroplasty (TKA), approximately 20% of patients are dissatisfied. A major reason for dissatisfaction and revision surgery after TKA is persistent pain. The radiological grade of osteoarthritis (OA) preoperatively has been investigated as a predictor of the outcome after TKA, with conflicting results. The aim of this study was to determine if there is a difference in the intensity of pain 12 months after TKA in relation to the preoperative radiological grade of OA alone, and the combination of the intensity of preoperative pain and radiological grade of OA. Methods. The preoperative data of 300 patients who underwent primary TKA were collected, including clinical information (age, sex, preoperative pain), psychological variables (depression, anxiety, pain catastrophizing, anticipated pain), and quantitative sensory testing (temporal summation, pressure pain thresholds, conditioned pain modulation). The preoperative radiological severity of OA was graded according to the Kellgren-Lawrence (KL) classification. Persistent pain in the knee was recorded 12 months postoperatively. Generalized linear models explored differences in postoperative pain according to the KL grade, and combined preoperative pain and KL grade. Relative risk models explored which preoperative variables were associated with the high preoperative pain/low KL grade group. Results. Pain 12 months after TKA was not associated with the preoperative KL grade alone. Significantly increased pain 12 months after TKA was found in patients with a combination of high preoperative pain and a low KL grade (p = 0.012). Patients in this group were significantly more likely to be male, younger, and have higher preoperative pain catastrophizing, higher depression, and lower anxiety (all p ≤ 0.05). Conclusion. Combined high preoperative pain and low radiological grade of OA, but not the radiological grade alone, was associated with a higher intensity of pain 12 months after primary TKA. This group may have a more complex cause of pain that requires additional psychological interventions in order to optimize the outcome of TKA. Cite this article: Bone Joint J 2022;104-B(11):1202–1208


Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims. A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis. Methods. Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits. Results. The patient cohort mean age was 66 years (SD seven years), 59% were female, and the mean BMI was 32 kg/m. 2. (SD 6 kg/m. 2. ). Mean two-year subsidence of the EF-TKA was 0.056 mm (95% confidence interval (CI) 0.025 to 0.086) versus 0.006 mm (95% CI -0.029 to 0.040) for the Std-TKA, and the two-year maximum total point motion (MTPM) was 0.285 mm (95% upper confidence limit (UCL) ≤ 0.363) versus 0.346 mm (95% UCL ≤ 0.432), respectively, for a mean difference of -0.061 mm (95% CI -0.196 to 0.074). Inducible displacement also did not differ between groups. The MTPMs between 12 and 24 months for each group was below the published threshold of 0.2 mm for predicting early aseptic loosening (p < 0.001 and p = 0.001, respectively). Conclusion. Both the enhanced fixation and the standard tibial implant design showed fixation with a predicted low risk of long-term aseptic loosening. Cite this article: Bone Jt Open 2024;5(1):20–27


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 846 - 854
3 May 2021
Clement ND Scott CEH Hamilton DF MacDonald D Howie CR

Aims. The aim of this study was to identify the minimal clinically important difference (MCID), minimal important change (MIC), minimal detectable change (MDC), and patient-acceptable symptom state (PASS) threshold in the Forgotten Joint Score (FJS) according to patient satisfaction six months following total knee arthroplasty (TKA). Methods. During a one-year period 484 patients underwent a primary TKA and completed preoperative and six-month FJS and OKS. At six months patients were asked, “How satisfied are you with your operated knee?” Their response was recorded as: very satisfied, satisfied, neutral, dissatisfied, or very dissatisfied. The difference between patients recording neutral (n = 44) and satisfied (n = 153) was used to define the MCID. MIC for a cohort was defined as the change in the FJS for those patients declaring their outcome as satisfied, whereas receiver operating characteristic curve analysis was used to determine the MIC for an individual and the PASS threshold. Distribution-based methodology was used to calculate the MDC. Results. Using satisfaction as the anchor question, the MCID for the FJS was 16.6 (95% confidence interval (CIs) 8.9 to 24.3; p < 0.001) and when adjusting for confounding this decreased to 13.7 points (95% CI 4.8 to 22.5; p < 0.001). The MIC for the FJS for a cohort of patients was 17.7 points and for an individual patient was 10 points. The MDC90 for the FGS was 12 points; where 90% of patients scoring more than this will have experienced a real change that is beyond measurement error. The PASS was defined as 22 points or more in the postoperative FJS. Conclusion. The estimates for MCID and MIC can be used to assess whether there is clinical difference between two groups and whether a cohort/patient has had a meaningful change in their FJS, respectively. The MDC90 of 12 points suggests a value lower than this may fall within measurement error. A postoperative FJS of 22 or more was predictive of achieving PASS. Cite this article: Bone Joint J 2021;103-B(5):846–854


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 604 - 612
1 May 2022
MacDessi SJ Wood JA Diwan A Harris IA

Aims. Intraoperative pressure sensors allow surgeons to quantify soft-tissue balance during total knee arthroplasty (TKA). The aim of this study was to determine whether using sensors to achieve soft-tissue balance was more effective than manual balancing in improving outcomes in TKA. Methods. A multicentre randomized trial compared the outcomes of sensor balancing (SB) with manual balancing (MB) in 250 patients (285 TKAs). The primary outcome measure was the mean difference in the four Knee injury and Osteoarthritis Outcome Score subscales (ΔKOOS. 4. ) in the two groups, comparing the preoperative and two-year scores. Secondary outcomes included intraoperative balance data, additional patient-reported outcome measures (PROMs), and functional measures. Results. There was no significant difference in ΔKOOS. 4. between the two groups at two years (mean difference 0.4 points (95% confidence interval (CI) -4.6 to 5.4); p = 0.869), and multiple regression found that SB was not associated with a significant ΔKOOS. 4. (0.2-point increase (95% CI -5.1 to 4.6); p = 0.924). There were no significant differences between groups in other PROMs. Six-minute walking distance was significantly increased in the SB group (mean difference 29 metres; p = 0.015). Four-times as many TKAs were unbalanced in the MB group (36.8% MB vs 9.4% SB; p < 0.001). Irrespective of group assignment, no differences were found in any PROM when increasing ICPD thresholds defined balance. Conclusion. Despite improved quantitative soft-tissue balance, the use of sensors intraoperatively did not differentially improve the clinical or functional outcomes two years after TKA. These results question whether a more precisely balanced TKA that is guided by sensor data, and often achieved by more balancing interventions, will ultimately have a significant effect on clinical outcomes. Cite this article: Bone Joint J 2022;104-B(5):604–612


Bone & Joint Open
Vol. 2, Issue 11 | Pages 974 - 980
25 Nov 2021
Allom RJ Wood JA Chen DB MacDessi SJ

Aims. It is unknown whether gap laxities measured in robotic arm-assisted total knee arthroplasty (TKA) correlate to load sensor measurements. The aim of this study was to determine whether symmetry of the maximum medial and lateral gaps in extension and flexion was predictive of knee balance in extension and flexion respectively using different maximum thresholds of intercompartmental load difference (ICLD) to define balance. Methods. A prospective cohort study of 165 patients undergoing functionally-aligned TKA was performed (176 TKAs). With trial components in situ, medial and lateral extension and flexion gaps were measured using robotic navigation while applying valgus and varus forces. The ICLD between medial and lateral compartments was measured in extension and flexion with the load sensor. The null hypothesis was that stressed gap symmetry would not correlate directly with sensor-defined soft tissue balance. Results. In TKAs with a stressed medial-lateral gap difference of ≤1 mm, 147 (89%) had an ICLD of ≤15 lb in extension, and 112 (84%) had an ICLD of ≤ 15 lb in flexion; 157 (95%) had an ICLD ≤ 30 lb in extension, and 126 (94%) had an ICLD ≤ 30 lb in flexion; and 165 (100%) had an ICLD ≤ 60 lb in extension, and 133 (99%) had an ICLD ≤ 60 lb in flexion. With a 0 mm difference between the medial and lateral stressed gaps, 103 (91%) of TKA had an ICLD ≤ 15 lb in extension, decreasing to 155 (88%) when the difference between the medial and lateral stressed extension gaps increased to ± 3 mm. In flexion, 47 (77%) had an ICLD ≤ 15 lb with a medial-lateral gap difference of 0 mm, increasing to 147 (84%) at ± 3 mm. Conclusion. This study found a strong relationship between intercompartmental loads and gap symmetry in extension and flexion measured with prostheses in situ. The results suggest that ICLD and medial-lateral gap difference provide similar assessment of soft-tissue balance in robotic arm-assisted TKA. Cite this article: Bone Jt Open 2021;2(11):974–980


Bone & Joint Open
Vol. 2, Issue 8 | Pages 576 - 582
2 Aug 2021
Fuchs M Kirchhoff F Reichel H Perka C Faschingbauer M Gwinner C

Aims. Current guidelines consider analyses of joint aspirates, including leucocyte cell count (LC) and polymorphonuclear percentage (PMN%) as a diagnostic mainstay of periprosthetic joint infection (PJI). It is unclear if these parameters are subject to a certain degree of variability over time. Therefore, the aim of this study was to evaluate the variation of LC and PMN% in patients with aseptic revision total knee arthroplasty (TKA). Methods. We conducted a prospective, double-centre study of 40 patients with 40 knee joints. Patients underwent joint aspiration at two different time points with a maximum period of 120 days in between these interventions and without any events such as other joint aspirations or surgeries. The main indications for TKA revision surgery were aseptic implant loosening (n = 24) and joint instability (n = 11). Results. Overall, 80 synovial fluid samples of 40 patients were analyzed. The average time period between the joint aspirations was 50 days (SD 32). There was a significantly higher percentage change in LC when compared to PMN% (44.1% (SD 28.6%) vs 27.3% (SD 23.7%); p = 0.003). When applying standard definition criteria, LC counts were found to skip back and forth between the two time points with exceeding the thresholds in up to 20% of cases, which was significantly more compared to PMN% for the European Bone and Joint Infection Society (EBJIS) criteria (p = 0.001), as well as for Musculoskeletal Infection Society (MSIS) (p = 0.029). Conclusion. LC and PMN% are subject to considerable variation. According to its higher interindividual variance, LC evaluation might contribute to false-positive or false-negative results in PJI assessment. Single LC testing prior to TKA revision surgery seems to be insufficient to exclude PJI. On the basis of the obtained results, PMN% analyses overrule LC measurements with regard to a conclusive diagnostic algorithm. Cite this article: Bone Jt Open 2021;2(8):566–572


Aims. The aim is to assess the cost-effectiveness of patellofemoral arthroplasty (PFA) in comparison with total knee arthroplasty (TKA) for the treatment of isolated patellofemoral osteoarthritis (OA) based on prospectively collected data on health outcomes and resource use from a blinded, randomized, clinical trial. Methods. A total of 100 patients with isolated patellofemoral osteoarthritis were randomized to receive either PFA or TKA by experienced knee surgeons trained in using both implants. Patients completed patient-reported outcomes including EuroQol five-dimension questionnaire (EQ-5D) and 6-Item Short-Form Health Survey questionnaire (SF-6D) before the procedure. The scores were completed again after six weeks, three, six, and nine months, and again after one- and two-year post-surgery and yearly henceforth. Time-weighted outcome measures were constructed. Cost data were obtained from clinical registrations and patient-reported questionnaires. Incremental gain in health outcomes (quality-adjusted life-years (QALYs)) and incremental costs were compared for the two groups of patients. Net monetary benefit was calculated assuming a threshold value of €10,000, €35,000, and €50,000 per QALY and used to test the statistical uncertainty and central assumptions about outcomes and costs. Results. The PFA group had an incremental 12 month EQ-5D gain of 0.056 (95% confidence interval (CI) 0.01 to 0.10) and an incremental 12 month cost of minus €328 (95% CI 836 to 180). PFA therefore dominates TKA by providing better and cheaper outcomes than TKA. The net monetary benefit of PFA was €887 (95% CI 324 to 1450) with the €10,000 threshold, and it was consistently positive when different measures of outcomes and different cost assumptions were used. Conclusion. This study provides robust evidence that PFA from a one-year hospital management perspective is cheaper and provides better outcomes than TKA when applied to patients with isolated patellofemoral osteoarthritis and performed by experienced knee surgeons. Cite this article: Bone Joint J 2020;102-B(4):449–457


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 490 - 497
1 Apr 2016
Maempel JF Wickramasinghe NR Clement ND Brenkel IJ Walmsley PJ

Aims. The pre-operative level of haemoglobin is the strongest predictor of the peri-operative requirement for blood transfusion after total knee arthroplasty (TKA). There are, however, no studies reporting a value that could be considered to be appropriate pre-operatively. . This study aimed to identify threshold pre-operative levels of haemoglobin that would predict the requirement for blood transfusion in patients who undergo TKA. . Patients and Methods. Analysis of receiver operator characteristic (ROC) curves of 2284 consecutive patients undergoing unilateral TKA was used to determine gender specific thresholds predicting peri-operative transfusion with the highest combined sensitivity and specificity (area under ROC curve 0.79 for males; 0.78 for females). Results. Threshold levels of 13.75 g/dl for males and 12.75 g/dl for females were identified. The rates of transfusion in males and females, respectively above these levels were 3.37% and 7.11%, while below these levels, they were 16.13% and 28.17%. Pre-operative anaemia increased the rate of transfusion by 6.38 times in males and 6.27 times in females. Blood transfusion was associated with an increased incidence of early post-operative confusion (odds ratio (OR) = 3.44), cardiac arrhythmia (OR = 5.90), urinary catheterisation (OR = 1.60), the incidence of deep infection (OR = 4.03) and mortality (OR = 2.35) one year post-operatively, and increased length of stay (eight days vs six days, p < 0.001). . Conclusion. Uncorrected low pre-operative levels of haemoglobin put patients at potentially modifiable risk and attempts should be made to correct this before TKA. Target thresholds for the levels of haemoglobin pre-operatively in males and females are proposed. Take home message: Low pre-operative haemoglobin levels put patients at unnecessary risk and should be corrected prior to surgery. Cite this article: Bone Joint J 2016;98-B:490–7


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 3 - 9
1 Jul 2019
Shohat N Tarabichi M Tan TL Goswami K Kheir M Malkani AL Shah RP Schwarzkopf R Parvizi J

Aims. The best marker for assessing glycaemic control prior to total knee arthroplasty (TKA) remains unknown. The purpose of this study was to assess the utility of fructosamine compared with glycated haemoglobin (HbA1c) in predicting early complications following TKA, and to determine the threshold above which the risk of complications increased markedly. Patients and Methods. This prospective multi-institutional study evaluated primary TKA patients from four academic institutions. Patients (both diabetics and non-diabetics) were assessed using fructosamine and HbA1c levels within 30 days of surgery. Complications were assessed for 12 weeks from surgery and included prosthetic joint infection (PJI), wound complication, re-admission, re-operation, and death. The Youden’s index was used to determine the cut-off for fructosamine and HbA1c associated with complications. Two additional cut-offs for HbA1c were examined: 7% and 7.5% and compared with fructosamine as a predictor for complications. Results. Overall, 1119 patients (441 men, 678 women) were included in the study. Fructosamine level of 293 µmol/l was identified as the optimal cut-off associated with complications. Patients with high fructosamine (> 293 µmol/l) were 11.2 times more likely to develop PJI compared with patients with low fructosamine (p = 0.001). Re-admission and re-operation rates were 4.2 and 4.5 times higher in patients with fructosamine above the threshold (p = 0.005 and p = 0.019, respectively). One patient (1.7%) from the elevated fructosamine group died compared with one patient (0.1%) in the normal fructosamine group (p = 0.10). These complications remained statistically significant in multiple regression analysis. Unlike fructosamine, all three cut-offs for HbA1c failed to show a significant association with complications. Conclusion. Fructosamine is a valid and an excellent predictor of complications following TKA. It better reflects the glycaemic control, has greater predictive power for adverse events, and responds quicker to treatment compared with HbA1c. These findings support the screening of all patients undergoing TKA using fructosamine and in those with a level above 293 µmol/l, the risk of surgery should be carefully weighed against its benefit. Cite this article: Bone Joint J 2019;101-B(7 Supple C):3–9


Bone & Joint Research
Vol. 8, Issue 5 | Pages 207 - 215
1 May 2019
Key S Scott G Stammers JG Freeman MAR Pinskerova V Field RE Skinner J Banks SA

Objectives. The medially spherical GMK Sphere (Medacta International AG, Castel San Pietro, Switzerland) total knee arthroplasty (TKA) was previously shown to accommodate lateral rollback while pivoting around a stable medial compartment, aiming to replicate native knee kinematics in which some coronal laxity, especially laterally, is also present. We assess coronal plane kinematics of the GMK Sphere and explore the occurrence and pattern of articular separation during static and dynamic activities. Methods. Using pulsed fluoroscopy and image matching, the coronal kinematics and articular surface separation of 16 well-functioning TKAs were studied during weight-bearing and non-weight-bearing, static, and dynamic activities. The closest distances between the modelled articular surfaces were examined with respect to knee position, and proportions of joint poses exhibiting separation were computed. Results. Overall, 1717 joint poses were analyzed. At a 1.0 mm detection threshold, 37 instances of surface separation were observed in the lateral compartment and four medially (p < 0.001). Separation was activity-dependent, both laterally and medially (p < 0.001), occurring more commonly during static deep flexion in the lateral compartment, and during static rotation in the medial compartment. Lateral separation occurred more frequently than medial during kneeling (7/14 lateral vs 1/14 medial; p = 0.031) and stepping (20/1022 lateral vs 0/1022 medial; p < 0.001). Separation varied significantly between individuals during dynamic activities. Conclusion. No consistent association between closest distances of the articular surfaces and knee position was found during any activity. Lift-off was infrequent and depended on the activity performed and the individual knee. Lateral separation was consistent with the design rationale. Medial lift-off was rare and mostly in non-weight-bearing activities. Cite this article: S. Key, G. Scott, J. G. Stammers, M. A. R. Freeman†, V. Pinskerova, R. E. Field, J. Skinner, S. A. Banks. Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation. Bone Joint Res 2019;8:207–215. DOI: 10.1302/2046-3758.85.BJR-2018-0237.R1


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1579 - 1584
1 Dec 2018
Turgeon TR Gascoyne TC Laende EK Dunbar MJ Bohm ER Richardson CG

Aims. The introduction of a novel design of total knee arthroplasty (TKA) must achieve outcomes at least as good as existing designs. A novel design of TKA with a reducing radius of the femoral component and a modified cam-post articulation has been released and requires assessment of the fixation to bone. Radiostereometric analysis (RSA) of the components within the first two postoperative years has been shown to be predictive of medium- to long-term fixation. The aim of this study was to assess the stability of the tibial component of this system during this period of time using RSA. Patients and Methods. A cohort of 30 patients underwent primary, cemented TKA using the novel posterior stabilized fixed-bearing (ATTUNE) design. There was an even distribution of men and women (15:15). The mean age of the patients was 64 years (sd 8) at the time of surgery; their mean body mass index (BMI) was 35.4 kg/m2 (sd 7.9). RSA was used to assess the stability of the tibial component at 6, 12, and 24 months compared with a six-week baseline examination. Patient-reported outcome measures were also assessed. Results. The mean maximum total point motion (MTPM) of the tibial component between 12 and 24 months postoperatively was 0.08 mm (sd 0.08), which is well below the published threshold of 0.2 mm (p < 0.001). Patient-reported outcome measures consistently improved. Conclusion. The tibial component of this novel design of TKA showed stability between assessment 12 and 24 months postoperatively, suggesting an acceptably low risk of medium- to long-term failure due to aseptic loosening


Aims. Patient-specific instrumentation of total knee arthroplasty (TKA) is a technique permitting the targeting of individual kinematic alignment, but deviation from a neutral mechanical axis may have implications on implant fixation and therefore survivorship. The primary objective of this randomized controlled study was to compare the fixation of tibial components implanted with patient-specific instrumentation targeting kinematic alignment (KA+PSI) versus components placed using computer-assisted surgery targeting neutral mechanical alignment (MA+CAS). Tibial component migration measured by radiostereometric analysis was the primary outcome measure (compared longitudinally between groups and to published acceptable thresholds). Secondary outcome measures were inducible displacement after one year and patient-reported outcome measures (PROMS) over two years. The secondary objective was to assess the relationship between alignment and both tibial component migration and inducible displacement. Patients and Methods. A total of 47 patients due to undergo TKA were randomized to KA+PSI (n = 24) or MA+CAS (n = 23). In the KA+PSI group, there were 16 female and eight male patients with a mean age of 64 years (. sd. 8). In the MA+CAS group, there were 17 female and six male patients with a mean age of 63 years (. sd. 7). Surgery was performed using cemented, cruciate-retaining Triathlon total knees with patellar resurfacing, and patients were followed up for two years. The effect of alignment on tibial component migration and inducible displacement was analyzed irrespective of study group. Results. There was no difference over two years in longitudinal migration of the tibial component between the KA+PSI and MA+CAS groups (reaching median maximum total point motion migration at two years of 0.40 mm for the KA+PSI group and 0.37 mm for the MA+CAS group, p = 0.82; p = 0.68 adjusted for age, sex, and body mass index (BMI) for all follow-ups). Both groups had mean migrations below acceptable thresholds. There was no difference in inducible displacement (p = 0.34) or PROMS (p = 0.61 for the Oxford Knee Score) between groups. There was no correlation between alignment and tibial component migration or alignment and inducible displacement. These findings support non-neutral alignment as a viable option with this component, with no evidence that it compromises fixation. Conclusion. Kinematic alignment using patient-specific instrumentation in TKA was associated with acceptable tibial component migration, indicating stable fixation. These results are supportive of future investigations of kinematic alignment. Cite this article: Bone Joint J 2019;101-B:929–940


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 163 - 169
1 Jun 2020
Lawrie CM Jo S Barrack T Roper S Wright RW Nunley RM Barrack RL

Aims. The aim of this study was to determine if the local delivery of vancomycin and tobramycin in primary total knee arthroplasty (TKA) can achieve intra-articular concentrations exceeding the minimum inhibitory concentration thresholds for bacteria causing acute prosthetic joint infection (PJI). Methods. Using a retrospective single-institution database of all primary TKAs performed between January 1 2014 and May 7 2019, we identified patients with acute PJI that were managed surgically within 90 days of the initial procedure. The organisms from positive cultures obtained at the time of revision were tested for susceptibility to gentamicin, tobramycin, and vancomycin. A prospective study was then performed to determine the intra-articular antibiotic concentration on postoperative day one after primary TKA using one of five local antibiotic delivery strategies with tobramycin and/or vancomycin mixed into the polymethylmethacrylate (PMMA) or vancomycin powder. Results. A total of 19 patients with acute PJI after TKA were identified and 29 unique bacterial isolates were recovered. The mean time to revision was 37 days (6 to 84). Nine isolates (31%) were resistant to gentamicin, ten (34%) were resistant to tobramycin, and seven (24%) were resistant to vancomycin. Excluding one Fusobacterium nucleatum, which was resistant to all three antibiotics, all isolates resistant to tobramycin or gentamicin were susceptible to vancomycin and vice versa. Overall, 2.4 g of tobramycin hand-mixed into 80 g of PMMA and 1 g of intra-articular vancomycin powder consistently achieved concentrations above the minimum inhibitory concentrations of susceptible organisms. Conclusion. One-third of bacteria causing acute PJI after primary TKA were resistant to the aminoglycosides commonly mixed into PMMA, and one-quarter were resistant to vancomycin. With one exception, all bacteria resistant to tobramycin were susceptible to vancomycin and vice versa. Based on these results, the optimal cover for organisms causing most cases of acute PJI after TKA can be achieved with a combination of tobramycin mixed in antibiotic cement, and vancomycin powder. Cite this article: Bone Joint J 2020;102-B(6 Supple A):163–169


Bone & Joint Open
Vol. 5, Issue 5 | Pages 401 - 410
20 May 2024
Bayoumi T Burger JA van der List JP Sierevelt IN Spekenbrink-Spooren A Pearle AD Kerkhoffs GMMJ Zuiderbaan HA

Aims

The primary objective of this registry-based study was to compare patient-reported outcomes of cementless and cemented medial unicompartmental knee arthroplasty (UKA) during the first postoperative year. The secondary objective was to assess one- and three-year implant survival of both fixation techniques.

Methods

We analyzed 10,862 cementless and 7,917 cemented UKA cases enrolled in the Dutch Arthroplasty Registry, operated between 2017 and 2021. Pre- to postoperative change in outcomes at six and 12 months’ follow-up were compared using mixed model analyses. Kaplan-Meier and Cox regression models were applied to quantify differences in implant survival. Adjustments were made for patient-specific variables and annual hospital volume.