header advert
Results 1 - 20 of 76
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 232 - 238
1 Feb 2020
Javed S Hadi S Imam MA Gerogiannis D Foden P Monga P

Aims. Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method. Methods. This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired t-test for significance and the Bland-Altman plot for agreement. Results. The mean glenoid version was -3.11° (-23.8° to 17.9°) using the Friedman method and -1.95° (-29.8° to 24.6°) using the Ellipse method (p = 0.002). In 16 patients the difference between methods was greater than 5°, which we considered to be clinically significant. There was poor agreement between methods with relatively large 95% limits of agreement. There was excellent inter-rater agreement between the observers for the Ellipse method and similarly, the intrarater agreement was excellent with a repeatability coefficient of 0.94. Conclusion. We recommend the use of the Ellipse modification to define the mid glenoid point prior to measuring the glenoid version in patients undergoing TSA. Cite this article: Bone Joint J 2020;102-B(2):232–238


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 534 - 542
1 May 2023
Makaram NS Khan LAK Jenkins PJ Robinson CM

Aims

The outcomes following nonoperative management of minimally displaced greater tuberosity (GT) fractures, and the factors which influence patient experience, remain poorly defined. We assessed the early patient-derived outcomes following these injuries and examined the effect of a range of demographic- and injury-related variables on these outcomes.

Methods

In total, 101 patients (53 female, 48 male) with a mean age of 50.9 years (19 to 76) with minimally displaced GT fractures were recruited to a prospective observational cohort study. During the first year after injury, patients underwent experiential assessment using the Disabilities of the Arm, Shoulder and Hand (DASH) score and assessment of associated injuries using MRI performed within two weeks of injury. The primary outcome was the one-year DASH score. Multivariate analysis was used to assess the effect of patient demographic factors, complications, and associated injuries, on outcome.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 56 - 63
1 Jan 2023
de Klerk HH Oosterhoff JHF Schoolmeesters B Nieboer P Eygendaal D Jaarsma RL IJpma FFA van den Bekerom MPJ Doornberg JN

Aims

This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons?

Methods

A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims

The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system.

Methods

We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 205 - 209
16 Mar 2023
Jump CM Mati W Maley A Taylor R Gratrix K Blundell C Lane S Solanki N Khan M Choudhry M Shetty V Malik RA Charalambous CP

Aims

Frozen shoulder is a common, painful condition that results in impairment of function. Corticosteroid injections are commonly used for frozen shoulder and can be given as glenohumeral joint (GHJ) injection or suprascapular nerve block (SSNB). Both injection types have been shown to significantly improve shoulder pain and range of motion. It is not currently known which is superior in terms of relieving patients’ symptoms. This is the protocol for a randomized clinical trial to investigate the clinical effectiveness of corticosteroid injection given as either a GHJ injection or SSNB.

Methods

The Therapeutic Injections For Frozen Shoulder (TIFFS) study is a single centre, parallel, two-arm, randomized clinical trial. Participants will be allocated on a 1:1 basis to either a GHJ corticosteroid injection or SSNB. Participants in both trial arms will then receive physiotherapy as normal for frozen shoulder. The primary analysis will compare the Oxford Shoulder Score (OSS) at three months after injection. Secondary outcomes include OSS at six and 12 months, range of shoulder movement at three months, and Numeric Pain Rating Scale, abbreviated Disabilities of Arm, Shoulder and Hand score, and EuroQol five-level five-dimension health index at three months, six months, and one year after injection. A minimum of 40 patients will be recruited to obtain 80% power to detect a minimally important difference of ten points on the OSS between the groups at three months after injection. The study is registered under ClinicalTrials.gov with the identifier NCT04965376.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 174 - 181
1 Feb 2024
Mandalia KP Brodeur PG Li LT Ives K Cruz Jr. AI Shah SS

Aims

The aim of this study was to characterize the influence of social deprivation on the rate of complications, readmissions, and revisions following primary total shoulder arthroplasty (TSA), using the Social Deprivation Index (SDI). The SDI is a composite measurement, in percentages, of seven demographic characteristics: living in poverty, with < 12 years of education, single-parent households, living in rented or overcrowded housing, households without a car, and unemployed adults aged < 65 years.

Methods

Patients aged ≥ 40 years, who underwent primary TSA between 2011 and 2017, were identified using International Classification of Diseases (ICD)-9 Clinical Modification and ICD-10 procedure codes for TSA in the New York Statewide Planning and Research Cooperative System database. Readmission, reoperation, and other complications were analyzed using multivariable Cox proportional hazards regression controlling for SDI, age, ethnicity, insurance status, and Charlson Comorbidity Index.


Bone & Joint Open
Vol. 3, Issue 10 | Pages 815 - 825
20 Oct 2022
Athanatos L Kulkarni K Tunnicliffe H Samaras M Singh HP Armstrong AL

Aims

There remains a lack of consensus regarding the management of chronic anterior sternoclavicular joint (SCJ) instability. This study aimed to assess whether a standardized treatment algorithm (incorporating physiotherapy and surgery and based on the presence of trauma) could successfully guide management and reduce the number needing surgery.

Methods

Patients with chronic anterior SCJ instability managed between April 2007 and April 2019 with a standardized treatment algorithm were divided into non-traumatic (offered physiotherapy) and traumatic (offered surgery) groups and evaluated at discharge. Subsequently, midterm outcomes were assessed via a postal questionnaire with a subjective SCJ stability score, Oxford Shoulder Instability Score (OSIS, adapted for the SCJ), and pain visual analogue scale (VAS), with analysis on an intention-to-treat basis.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1000 - 1006
1 Sep 2023
Macken AA Haagmans-Suman A Spekenbrink-Spooren A van Noort A van den Bekerom MPJ Eygendaal D Buijze GA

Aims

The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years.

Methods

All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or deltopectoral approach were included, with a minimum follow-up of five years. Cox and logistic regression models were used to assess the association between the approach and the implant survival, instability, and glenoid loosening, independent of confounders.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 842 - 848
1 Aug 2024
Kriechling P Whitefield R Makaram NS Brown IDM Mackenzie SP Robinson CM

Aims

Vascular compromise due to arterial injury is a rare but serious complication of a proximal humeral fracture. The aims of this study were to report its incidence in a large urban population, and to identify clinical and radiological factors which are associated with this complication. We also evaluated the results of the use of our protocol for the management of these injuries.

Methods

A total of 3,497 adult patients with a proximal humeral fracture were managed between January 2015 and December 2022 in a single tertiary trauma centre. Their mean age was 66.7 years (18 to 103) and 2,510 (72%) were female. We compared the demographic data, clinical features, and configuration of those whose fracture was complicated by vascular compromise with those of the remaining patients. The incidence of vascular compromise was calculated from national population data, and predictive factors for its occurrence were investigated using univariate analysis.


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims

There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA).

Methods

We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1190 - 1196
1 Sep 2017
Swarup I Henn CM Nguyen JT Dines DM Craig EV Warren RF Gulotta LV Henn III RF

Aims . Few studies have evaluated the relationship between patients’ pre-operative expectations and the outcome of orthopaedic procedures. Our aim was to determine the effect of expectations on the outcome after primary anatomical total shoulder arthroplasty (TSA). We hypothesised that patients with greater expectations would have better outcomes. . Patients and Methods. Patients undergoing primary anatomical TSA completed the Hospital for Special Surgery’s Shoulder Expectations Survey pre-operatively. The American Shoulder and Elbow Surgeons (ASES), Shoulder Activity Scale (SAS), Short-Form-36 (SF-36), and visual analogue scale (VAS) for pain, fatigue, and general health scores were also collected pre-operatively and two years post-operatively. Pearson correlations were used to assess the relationship between the number of expectations and the outcomes. Differences in outcomes between those with higher and lower levels of expectations for each expectation were assessed by independent samples t-test. Multivariable linear regression analysis was used to control for potential confounding factors. Results. A total of 67 patients were evaluated two years post-operatively. Most parameters of outcome improved significantly from baseline and most patients were satisfied. A greater number of expectations was associated with a significantly greater improvement in the ASES score (p = 0.02). In the multivariable analysis, a greater number of expectations was an independent predictor of better ASES, VAS and SF-36 scores, as well as improvements in ASES and VAS pain scores (p < 0.05). Greater expectations for many specific expectation questions were significantly associated with better outcomes (p < 0.05). Conclusion. TSA is a successful procedure with significant improvements in outcome, and greater pre-operative expectations are associated with better outcomes. . Cite this article: Bone Joint J 2017;99-B:1190–6


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 394 - 400
1 Mar 2022
Lee KJ Kim YT Choi M Kim SH

Aims

The aim of this study was to compare the characteristics and outcomes of L-shaped and reverse L-shaped rotator cuff tears.

Methods

A total of 82 shoulders (81 patients) after arthroscopic rotator cuff repair were retrospectively enrolled. The mean age of the patients was 62 years (SD 6), 33 shoulders (40.2%) were in male patients, and 57 shoulders (69.5%) were the right shoulder. Of these, 36 shoulders had an L-shaped tear (group L) and 46 had a reverse L-shaped tear (group RL). Both groups were compared regarding characteristics, pre- and postoperative pain, and functional outcomes. Muscle status was assessed by preoperative MRI, and re-tear rates by postoperative ultrasonography or MRI.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 83 - 90
1 Jan 2022
Batten TJ Gallacher S Evans JP Harding RJ Kitson J Smith CD Thomas WJ

Aims

The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up.

Methods

Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 401 - 407
1 Mar 2022
Kriechling P Zaleski M Loucas R Loucas M Fleischmann M Wieser K

Aims

The aim of this study was to report the incidence of implant-related complications, further operations, and their influence on the outcome in a series of patients who underwent primary reverse total shoulder arthroplasty (RTSA).

Methods

The prospectively collected clinical and radiological data of 797 patients who underwent 854 primary RTSAs between January 2005 and August 2018 were analyzed. The hypothesis was that the presence of complications would adversely affect the outcome. Further procedures were defined as all necessary operations, including reoperations without change of components, and partial or total revisions. The clinical outcome was evaluated using the absolute and relative Constant Scores (aCS, rCS), the Subjective Shoulder Value (SSV) scores, range of motion, and pain.