Aims. There is a lack of long-term data for
Percutaneous stabilisation of tibial fractures by locking plates has become an accepted form of osteosynthesis. A potential disadvantage of this technique is the risk of damage to the neurovascular bundles in the anterior and peroneal compartments. Our aim in this anatomical study was to examine the relationship of the deep peroneal nerve to a percutaneously-inserted Less Invasive Stabilisation System tibial plate in the lower limbs of 18 cadavers. Screws were inserted through stab incisions. The neurovascular bundle was dissected to reveal its relationship to the plate and screws. In all cases, the deep peroneal nerve was in direct contact with the plate between the 11th and the 13th holes. In ten specimens the nerve crossed superficial to the plate, in six it was interposed between the plate and the bone and in the remaining two specimens it coursed at the edge of the plate. Percutaneous insertion of plates with more than ten holes is not recommended because of the risk of injury to the neurovascular structures. When longer plates are required we suggest distal exposure so that the neurovascular bundle may be displayed and protected.
We compared the outcome of closed intramedullary nailing with
Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest. A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS).Aims
Methods
The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients. In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.Aims
Methods
We report the long-term outcomes of the UK Heel Fracture Trial (HeFT), a pragmatic, multicentre, two-arm, assessor-blinded, randomized controlled trial. HeFT recruited 151 patients aged over 16 years with closed displaced, intra-articular fractures of the calcaneus. Patients with significant deformity causing fibular impingement, peripheral vascular disease, or other significant limb injuries were excluded. Participants were randomly allocated to open reduction and internal fixation (ORIF) or nonoperative treatment. We report Kerr-Atkins scores, self-reported difficulty walking and fitting shoes, and additional surgical procedures at 36, 48, and 60 months.Aims
Methods
Minimally invasive fixation of pelvic fragility fractures is recommended to reduce pain and allow early mobilization. The purpose of this study was to evaluate the outcome of two different stabilization techniques in bilateral fragility fractures of the sacrum (BFFS). A non-randomized, prospective study was carried out in a level 1 trauma centre. BFFS in 61 patients (mean age 80 years (SD 10); four male, 57 female) were treated surgically with bisegmental transsacral stablization (BTS; n = 41) versus spinopelvic fixation (SP; n = 20). Postoperative full weightbearing was allowed. The outcome was evaluated at two timepoints: discharge from inpatient treatment (TP1; Fitbit tracking, Zebris stance analysis), and ≥ six months (TP2; Fitbit tracking, Zebris analysis, based on modified Oswestry Disability Index (ODI), Majeed Score (MS), and the 12-Item Short Form Survey 12 (SF-12). Fracture healing was assessed by CT. The primary outcome parameter of functional recovery was the per-day step count; the secondary parameter was the subjective outcome assessed by questionnaires.Aims
Methods
The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors.Aims
Methods
No randomized comparative study has compared the extensile lateral approach (ELA) and sinus tarsi approach (STA) for Sanders type 2 calcaneal fractures. This randomized comparative study was conducted to confirm whether the STA was prone to fewer wound complications than the ELA. Between August 2013 and August 2018, 64 patients with Sanders type 2 calcaneus fractures were randomly assigned to receive surgical treatment by the ELA (32 patients) and STA (32 patients). The primary outcome was development of wound complications. The secondary outcomes were postoperative complications, pain scored of a visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, 36-item Short Form health survey, operative duration, subtalar joint range of motion (ROM), Böhler’s angle and calcaneal width, and posterior facet reduction.Aims
Methods
Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.Aims
Methods
Currently, periprosthetic fractures are excluded from the American Society for Bone and Mineral Research (ASBMR) definition of atypical femoral fracture (AFFs). This study aims to report on a series of periprosthetic femoral fractures (PFFs) that otherwise meet the criteria for AFFs. Secondary aims were to identify predictors of periprosthetic atypical femoral fractures (PAFFs) and quantify the complications of treatment. This was a retrospective case control study of consecutive patients with periprosthetic femoral fractures between 2007 and 2017. Two observers identified 16 PAFF cases (mean age 73.9 years (44 to 88), 14 female patients) and 17 typical periprosthetic fractures in patients on bisphosphonate therapy as controls (mean age 80.7 years (60 to 86, 13 female patients). Univariate and multivariate analysis was performed to identify predictors of PAFF. Management and complications were recorded.Aims
Patients and Methods
The aims of this study were to establish whether composite fixation
(rail-plate) decreases fixator time and related problems in the
management of patients with infected nonunion of tibia with a segmental
defect, without compromising the anatomical and functional outcomes
achieved using the classical Ilizarov technique. We also wished
to study the acceptability of this technique using patient-based
objective criteria. Between January 2012 and January 2015, 14 consecutive patients
were treated for an infected nonunion of the tibia with a gap and
were included in the study. During stage one, a radical debridement
of bone and soft tissue was undertaken with the introduction of
an antibiotic-loaded cement spacer. At the second stage, the tibia
was stabilized using a long lateral locked plate and a six-pin monorail
fixator on its anteromedial surface. A corticotomy was performed
at the appropriate level. During the third stage, i.e. at the end
of the distraction phase, the transported fragment was aligned and
fixed to the plate with two to four screws. An iliac crest autograft
was added to the docking site and the fixator was removed. Functional
outcome was assessed using the Association for the Study and Application
of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes
were assessed using the Musculoskeletal Tumor Society (MSTS) score.Aims
Patients and Methods
Surgical site infection can be a devastating complication of
hemiarthroplasty of the hip, when performed in elderly patients
with a displaced fracture of the femoral neck. It results in a prolonged
stay in hospital, a poor outcome and increased costs. Many studies
have identified risk and prognostic factors for deep infection.
However, most have combined the rates of infection following total
hip arthroplasty and internal fixation as well as hemiarthroplasty, despite
the fact that they are different entities. The aim of this study
was to clarify the risk and prognostic factors causing deep infection
after hemiarthroplasty alone. Data were extracted from a prospective hip fracture database
and completed by retrospective review of the hospital records. A
total of 916 patients undergoing a hemiarthroplasty in two level
II trauma teaching hospitals between 01 January 2011 and
01 May 2016 were included. We analysed the potential peri-operative
risk factors with univariable and multivariable logistic regression
analysis.Aims
Patients and Methods
The anterior pelvic internal fixator is increasingly used for
the treatment of unstable, or displaced, injuries of the anterior
pelvic ring. The evidence for its use, however, is limited. The
aim of this paper is to describe the indications for its use, how
it is applied and its complications. We reviewed the case notes and radiographs of 50 patients treated
with an anterior pelvic internal fixator between April 2010 and
December 2015 at a major trauma centre in the United Kingdom. The
median follow-up time was 38 months (interquartile range 24 to 51).Aims
Patients and Methods
In the time since Letournel popularised the surgical
treatment of acetabular fractures, more than 25 years ago, there
have been many changes within the field, related to patients, surgical
technique, implants and post-operative care. However, the long-term
outcomes appear largely unchanged. Does this represent stasis or
have the advances been mitigated by other negative factors? In this
article we have attempted to document the recent changes within
the surgery of patients with a fracture involving the acetabulum,
outline contemporary management, and identify the major problem
areas where further research is most needed. Cite this article:
Fractures of the distal femur can be challenging to manage and
are on the increase in the elderly osteoporotic population. Management
with casting or bracing can unacceptably limit a patient’s ability
to bear weight, but historically, operative fixation has been associated
with a high rate of re-operation. In this study, we describe the outcomes
of fixation using modern implants within a strategy of early return
to function. All patients treated at our centre with lateral distal femoral
locking plates (LDFLP) between 2009 and 2014 were identified. Fracture
classification and operative information including weight-bearing
status, rates of union, re-operation, failure of implants and mortality
rate, were recorded.Aims
Patients and Methods
External fixators are the traditional fixation method of choice for contaminated open fractures. However, patient acceptance is low due to the high profile and therefore physical burden of the constructs. An externalised locking compression plate is a low profile alternative. However, the biomechanical differences have not been assessed. The objective of this study was to evaluate the axial and torsional stiffness of the externalised titanium locking compression plate (ET-LCP), the externalised stainless steel locking compression plate (ESS-LCP) and the unilateral external fixator (UEF). A fracture gap model was created to simulate comminuted mid-shaft tibia fractures using synthetic composite bones. Fifteen constructs were stabilised with ET-LCP, ESS-LCP or UEF (five constructs each). The constructs were loaded under both axial and torsional directions to determine construct stiffness.Objectives
Methods
Antegrade nailing of proximal humeral fractures
using a straight nail can damage the bony insertion of the supraspinatus
tendon and may lead to varus failure of the construct. In order
to establish the ideal anatomical landmarks for insertion of the
nail and their clinical relevance we analysed CT scans of bilateral
proximal humeri in 200 patients (mean age 45.1 years ( We therefore emphasise the need for ‘fastidious’ pre-operative
planning to minimise this risk. Cite this article:
We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured, using two methods, to find the maximum radiological displacement of the fracture and the quality of the reduction according to the criteria of Tornetta and Matta. There were 19 vertical shear fractures and 16 compression injuries. The mean age of the patients was 33.5 years (10 to 59) and mean delay to surgery was 4.6 days (0 to 16) in the 34 acute injuries. The mean operative time in isolated procedures was 103.4 minutes ( The frame was shown to be effective, allowing the surgeon to obtain a satisfactory reduction and fixation of acute displaced disruptions of the pelvic ring.
Unstable bicondylar tibial plateau fractures
are rare and there is little guidance in the literature as to the
best form of treatment. We examined the short- to medium-term outcome
of this injury in a consecutive series of patients presenting to
two trauma centres. Between December 2005 and May 2010, a total
of 55 fractures in 54 patients were treated by fixation, 34 with
peri-articular locking plates and 21 with limited access direct
internal fixation in combination with circular external fixation
using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively,
patient-reported outcome measures including the WOMAC index and
SF-36 scores showed functional deficits, although there was no significant
difference between the two forms of treatment. Despite low outcome scores,
patients were generally satisfied with the outcome. We achieved
good clinical and radiological outcomes, with low rates of complication.
In total, only three patients (5%) had collapse of the joint of
>
4 mm, and metaphysis to diaphysis angulation of greater than 5º,
and five patients (9%) with displacement of >
4 mm. All patients
in our study went on to achieve full union. This study highlights the serious nature of this injury and generally
poor patient-reported outcome measures following surgery, despite
treatment by experienced surgeons using modern surgical techniques.
Our findings suggest that treatment of complex bicondylar tibial
plateau fractures with either a locking plate or a TSF gives similar
clinical and radiological outcomes. Cite this article: