Results 1 - 20 of 74
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 82 - 88
1 May 2024
Villa JM Rajschmir K Hosseinzadeh S Manrique-Succar J Grieco P Higuera-Rueda CA Riesgo AM

Aims. Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation. Methods. A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the operating surgeon, by comparing the immediate postoperative radiographs with the ones at latest follow-up. Mean follow-up was 557 days (SD 441; 31 to 1,707). Results. Out of the 33 cases analyzed, six (18.2%) constructs required revision, with four revisions due to uncontrolled infection, one for dislocation, and one for aseptic loosening. Among the 27 non-revised constructs, only one showed wider radiolucencies compared to immediate postoperative radiographs, indicating potential loosening. Patients who underwent revision (n = 6) were significantly younger and had a higher BMI compared to those with non-revised constructs (p = 0.016 and p = 0.026, respectively). Sex, race, ethnicity, American Society of Anesthesiologists grade, infection status (patients with postoperative PJI diagnosis (septic) vs patients without such diagnosis (aseptic)), and mean follow-up did not significantly differ between revised and non-revised groups. Conclusion. The HiRISC technique may serve as a feasible short-term (about one to two years) alternative in patients with large acetabular defects, particularly in cases of PJI. Longer follow-up is necessary to establish the long-term survival of this technique. Cite this article: Bone Joint J 2024;106-B(5 Supple B):82–88


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 721 - 726
1 Jun 2006
Girard J Lavigne M Vendittoli P Roy AG

We have compared the biomechanical nature of the reconstruction of the hip in conventional total hip arthroplasty (THA) and surface replacement arthroplasty (SRA) in a randomised study involving 120 patients undergoing unilateral primary hip replacement. The contralateral hip was used as a control. Post-operatively, the femoral offset was significantly increased with THA (mean 5.1 mm; −2.8 to 11.6) and decreased with SRA (mean −3.3 mm; −8.9 to 8.2). Femoral offset was restored within . sd. 4 mm in 14 (25%) of those with THA and in 28 (57%) of the patients receiving SRA (p < 0.001). In the THA group, the leg was lengthened by a mean of 2.6 mm (−6.04 to +12.9), whereas it was shortened by a mean of 1.9 mm (−7.1 to +2.05) in the SRA group, compared with the contralateral side. Leg-length inequality was restored within . sd. 4 mm in 42 (86%) of the SRA and 33 (60%) of the THA patients. The radiological parameters of acetabular reconstruction were similar in both groups. Restoration of the normal proximal femoral anatomy was more precise with SRA. The enhanced stability afforded by the use of a large-diameter femoral head avoided over-lengthening of the limb or increased offset to improve soft-tissue tension as occurs sometimes in THA. In a subgroup of patients with significant pre-operative deformity, restoration of the normal hip anatomy with lower pre-operative femoral offset or significant shortening of the leg was still possible with SRA


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 863 - 866
1 Jun 2005
Nagarajah K Aslam N McLardy Smith P McNally M

We describe a technique of ‘cross-hip distraction’ to reduce a dislocated hip with subsequent reconstruction of the joint for septic arthritis with extensive femoral osteomyelitis. A 27-year-old woman presented with a dislocated, collapsed femoral head and chronic osteomyelitis of the femur. Examination revealed a leg-length discrepancy of 7 cm and an irritable hip. A staged technique was used with primary clearance of osteomyelitis and secondary reconstruction of the hip. A cross-hip monolateral external fixator was used to establish normal anatomy followed by an arthroplasty. A good functional outcome was achieved. The use of cross-hip distraction avoids soft-tissue and nerve damage and achieved improved abductor function before arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 333 - 340
1 Mar 2009
Sariali E Mouttet A Pasquier G Durante E Catone Y

Pre-operative computerised three-dimensional planning was carried out in 223 patients undergoing total hip replacement with a cementless acetabular component and a cementless modular-neck femoral stem. Components were chosen which best restored leg length and femoral offset. The post-operative restoration of the anatomy was assessed by CT and compared with the pre-operative plan. The component implanted was the same as that planned in 86% of the hips for the acetabular implant, 94% for the stem, and 93% for the neck-shaft angle. The rotational centre of the hip was restored with a mean accuracy of 0.73 mm (. sd. 3.5) craniocaudally and 1.2 mm (. sd. 2) laterally. Limb length was restored with a mean accuracy of 0.3 mm (. sd. 3.3) and femoral offset with a mean accuracy of 0.8 mm (. sd. 3.1). This method appears to offer high accuracy in hip reconstruction as the difficulties likely to be encountered when restoring the anatomy can be anticipated and solved pre-operatively by optimising the selection of implants. Modularity of the femoral neck helped to restore the femoral offset and limb length


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 63 - 67
1 Jan 1990
Jasty M Harris W

We evaluated 38 hip reconstructions in 36 patients at a mean follow-up of 5.9 years (range 4 to 9.1) after femoral head allografts had been used to augment severely deficient acetabular bone stock. The patients were all relatively young and had many previous operations. Their pre-operative Harris hip rating averaged 46 points (range 18 to 73). All the allografts united and there were no infections. However, 12 acetabular components (32%) became loose; six of these had needed revision using the healed allograft, and two hips had required resection arthroplasty. The 30 surviving hips had a mean Harris hip score of 82 points. Some radiographic evidence of graft resorption was seen in 23 hips, though this was mild in 17. The extent of cover provided by the allograft and the severity of graft resorption both correlated with acetabular loosening. Although structural allografts had allowed successful hip reconstructions in many of these patients with major bone loss, the failure rate had increased from zero at four years to 32% at six years; clearly they provide only a short-term solution


Bone & Joint 360
Vol. 11, Issue 3 | Pages 40 - 43
1 Jun 2022


Bone & Joint 360
Vol. 11, Issue 5 | Pages 39 - 42
1 Oct 2022


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 22 - 30
1 Jan 2018
Brown TS Salib CG Rose PS Sim FH Lewallen DG Abdel MP

Aims

Reconstruction of the acetabulum after resection of a periacetabular malignancy is technically challenging and many different techniques have been used with varying success. Our aim was to prepare a systematic review of the literature dealing with these techniques in order to clarify the management, the rate of complications and the outcomes.

Patients and Methods

A search of PubMed and MEDLINE was conducted for English language articles published between January 1990 and February 2017 with combinations of key search terms to identify studies dealing with periacetabular resection with reconstruction in patients with a malignancy. Studies in English that reported radiographic or clinical outcomes were included. Data collected from each study included: the number and type of reconstructions, the pathological diagnosis of the lesions, the mean age and follow-up, gender distribution, implant survivorship, complications, functional outcome, and mortality. The results from individual studies were combined for the general analysis, and then grouped according to the type of reconstruction.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1363 - 1368
1 Oct 2007
Barakat MJ While T Pyman J Gargan M Monsell F

The results of a functional, clinical and radiological study of 30 children (60 hips) with whole-body cerebral palsy were reviewed at a mean follow-up of 10.2 years (9.5 to 11). Correction of windsweep deformity of the hips was performed by bilateral simultaneous combined soft-tissue and bony surgery at a mean age of 7.7 years (3.1 to 12.2).

We were able to recall 22 patients; five had died of unrelated causes and three were lost to follow-up. Evaluation involved interviews with patients/carers and clinical and radiological examination.

The gross motor functional classification system was used to assess overall motor function and showed improvement in seven patients. Of the 12 patients thought to have pain pre-operatively, only one had pain post-operatively. Improved handling was reported in 18 of 22 patients (82%). Those with handling problems were attributed by the carers to growth of the patients. All patients/carers considered the procedure worthwhile. The range of hip movements improved, and the mean windsweep index improved from 50 pre-operatively to 36 at follow-up.

The migration percentage and centre-edge angle were assessed on plain radiographs. Radiological containment improved, the mean migration percentage improved from 50 pre-operatively to 20 at follow-up and the mean centre-edge angle improved from −5° to 29°.

No statistical difference was noted between the three-year and ten-year follow-up results, indicating that the improvements in clinical and radiological outcome had been maintained.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 468 - 474
1 May 1993
Schuller H Dalstra M Huiskes R Marti R

In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found that the lateral acetabular rim plays an important role in the load transfer of the pelvic bone. When the superlateral rim was lacking, the load shifted to the posterosuperior rim and to the area of pubic support, and the stresses in all materials, especially in the cement and in the trabecular bone, increased greatly. At the cement-bone interface the tilting component of the shear stress increased threefold. In a model in which the dysplastic acetabulum was augmented by a rigidly fixed, load-transmitting bone graft, the stresses were considerably diminished.


Bone & Joint 360
Vol. 12, Issue 4 | Pages 38 - 41
1 Aug 2023

The August 2023 Children’s orthopaedics Roundup. 360. looks at: DDH: What can patients expect after open reduction?; Femoral head deformity associated with hip displacement in non-ambulatory cerebral palsy; Bony hip reconstruction for displaced hips in patients with cerebral palsy: is postoperative immobilization indicated?; Opioid re-prescriptions after ACL reconstruction in adolescents are associated with subsequent opioid use disorder; Normative femoral and tibial lengths in a modern population of USA children; Retrospective analysis of associated anomalies in 636 patients with operatively treated congenital scoliosis; Radiological hip shape and patient-reported outcome measures in healed Perthes’ disease; Significantly displaced adolescent posterior sternoclavicular joint injuries


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1303 - 1309
1 Oct 2018
Nodzo SR Chang C Carroll KM Barlow BT Banks SA Padgett DE Mayman DJ Jerabek SA

Aims. The aim of this study was to evaluate the accuracy of implant placement when using robotic assistance during total hip arthroplasty (THA). Patients and Methods. A total of 20 patients underwent a planned THA using preoperative CT scans and robotic-assisted software. There were nine men and 11 women (n = 20 hips) with a mean age of 60.8 years (. sd. 6.0). Pelvic and femoral bone models were constructed by segmenting both preoperative and postoperative CT scan images. The preoperative anatomical landmarks using the robotic-assisted system were matched to the postoperative 3D reconstructions of the pelvis. Acetabular and femoral component positions as measured intraoperatively and postoperatively were evaluated and compared. Results. The system reported accurate values for reconstruction of the hip when compared to those measured postoperatively using CT. The mean deviation from the executed overall hip length and offset were 1.6 mm (. sd. 2.9) and 0.5 mm (. sd. 3.0), respectively. Mean combined anteversion was similar and correlated between intraoperative measurements and postoperative CT measurements (32.5°, . sd. 5.9° versus 32.2°, . sd. 6.4°; respectively; R. 2. = 0.65; p < 0.001). There was a significant correlation between mean intraoperative (40.4°, . sd. 2.1°) acetabular component inclination and mean measured postoperative inclination (40.12°, . sd. 3.0°, R. 2. = 0.62; p < 0.001). There was a significant correlation between mean intraoperative version (23.2°, . sd. 2.3°), and postoperatively measured version (23.0°, . sd. 2.4°; R. 2. = 0.76; p < 0.001). Preoperative and postoperative femoral component anteversion were significantly correlated with one another (R. 2. = 0.64; p < 0.001). Three patients had CT scan measurements that differed substantially from the intraoperative robotic measurements when evaluating stem anteversion. Conclusion. This is the first study to evaluate the success of hip reconstruction overall using robotic-assisted THA. The overall hip reconstruction obtained in the operating theatre using robotic assistance accurately correlated with the postoperative component position assessed independently using CT based 3D modelling. Clinical correlation during surgery should continue to be practiced and compared with observed intraoperative robotic values. Cite this article: Bone Joint J 2018;100-B:1303–9


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 391 - 397
1 Feb 2021
Houdek MT Wunder JS Abdel MP Griffin AM Hevesi M Rose PS Ferguson PC Lewallen DG

Aims. Hip reconstruction after resection of a periacetabular chondrosarcoma is complex and associated with a high rate of complications. Previous reports have compared no reconstruction with historical techniques that are no longer used. The aim of this study was to compare the results of tantalum acetabular reconstruction to both historical techniques and no reconstruction. Methods. We reviewed 66 patients (45 males and 21 females) with a mean age of 53 years (24 to 81) who had undergone acetabular resection for chondrosarcoma. A total of 36 patients (54%) underwent acetabular reconstruction, most commonly with a saddle prosthesis (n = 13; 36%) or a tantalum total hip arthroplasty (THA) (n = 10; 28%). Mean follow-up was nine years (SD 4). Results. There was no difference in the mean age (p = 0.63), sex (p = 0.110), tumour volume (p = 0.646), or type of resection carried out (p > 0.05) between patients with and without reconstruction. Of the original 66 patients, 61 (92%) were ambulant at final follow-up. There was no difference in the proportion of patients who could walk in the reconstruction and 'no reconstruction' groups (p = 0.649). There was no difference in the mean Musculoskeletal Tumor Society (MSTS) score between patients who were reconstructed and those who were not (61% vs 56%; p = 0.378). Patients with a tantalum THA had a significantly (p = 0.015) higher mean MSTS score (78%) than those who were reconstructed with a saddle prosthesis (47%) or who had not been reconstructed (56%). Patients who had undergone reconstruction were more likely to have complications (81% vs 53%; p = 0.033). Conclusion. Reconstruction after resection of the acetabulum is technically demanding. In selected cases, reconstruction is of benefit, especially when reconstruction is by tantalum THA; however, the follow-up for these patients remains mid-term. When not feasible, patients with no reconstruction have an acceptable functional outcome. Level of Evidence: Level III Therapeutic. Cite this article: Bone Joint J 2021;103-B(2):391–397


Bone & Joint 360
Vol. 3, Issue 1 | Pages 35 - 37
1 Feb 2014

The February 2014 Children’s orthopaedics Roundup. 360 . looks at: flexible plasters; dual 8-plate or ablation for knee epiphysiodesis; ultrasounds for pulled elbow; leg length without the radiation; Boyd amputation in limb deficiencies; gold standard club foot treatment; quadrupled semitendinosis graft effective in paediatric ACL reconstruction; and predicting complications following cerebral palsy hip reconstruction


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1167 - 1171
1 Sep 2014
Khan O Witt J

The cam-type deformity in femoroacetabular impingement is a 3D deformity. Single measurements using radiographs, CT or MRI may not provide a true estimate of the magnitude of the deformity. We performed an analysis of the size and location of measurements of the alpha angle (α°) using a CT technique which could be applied to the 3D reconstructions of the hip. Analysis was undertaken in 42 patients (57 hips; 24 men and 18 women; mean age 38 years (16 to 58)) who had symptoms of femoroacetabular impingement related to a cam-type abnormality. An α° of > 50° was considered a significant indicator of cam-type impingement. Measurements of the α° were made at different points around the femoral head/neck junction at intervals of 30°: starting at the nine o’clock (posterior), ten, eleven and twelve o’clock (superior), one, two and ending at three o’clock (anterior) position. The mean maximum increased α° was 64.6° (50.8° to 86°). The two o’clock position was the most common point to find an increased α° (53 hips; 93%), followed by one o’clock (48 hips; 84%). The largest α° for each hip was found most frequently at the two o’clock position (46%), followed by the one o’clock position (39%). Generally, raised α angles extend over three segments of the clock face. Single measurements of the α°, whether pre- or post-operative, should be viewed with caution as they may not be representative of the true size of the deformity and not define whether adequate correction has been achieved following surgery. Cite this article: Bone Joint J 2014;96-B:1167–71.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 259 - 265
1 Feb 2013
Dhawale AA Karatas AF Holmes L Rogers KJ Dabney KW Miller F

We reviewed the long-term radiological outcome, complications and revision operations in 19 children with quadriplegic cerebral palsy and hip dysplasia who underwent combined peri-iliac osteotomy and femoral varus derotation osteotomy. They had a mean age of 7.5 years (1.6 to 10.9) and comprised 22 hip dislocations and subluxations. We also studied the outcome for the contralateral hip. At a mean follow-up of 11.7 years (10 to 15.1) the Melbourne cerebral palsy (CP) hip classification was grade 2 in 16 hips, grade 3 in five, and grade 5 in one. There were five complications seen in four hips (21%, four patients), including one dislocation, one subluxation, one coxa vara with adduction deformity, one subtrochanteric fracture and one infection. A recurrent soft-tissue contracture occurred in five hips and ten required revision surgery. In pre-adolescent children with quadriplegic cerebral palsy good long-term outcomes can be achieved after reconstruction of the hip; regular follow-up is required. Cite this article: Bone Joint J 2013;95-B:259–65


Bone & Joint 360
Vol. 11, Issue 6 | Pages 42 - 45
1 Dec 2022

The December 2022 Children’s orthopaedics Roundup360 looks at: Immobilization of torus fractures of the wrist in children (FORCE): a randomized controlled equivalence trial in the UK; Minimally invasive method in treatment of idiopathic congenital vertical talus: recurrence is uncommon; “You’re O.K. Anaesthesia”: closed reduction of displaced paediatric forearm and wrist fractures in the office without anaesthesia; Trunk range of motion and patient outcomes after anterior vertebral body tethering versus posterior spinal fusion: comparison using computerized 3D motion capture technology; Selective dorsal rhizotomy for individuals with spastic cerebral palsy; Scheuermann’s kyphosis and posterior spinal fusion; All-pedicle-screw constructs in skeletally immature patients with severe idiopathic early-onset scoliosis; Proximal femoral screw hemiepiphysiodesis in children with cerebral palsy.


Aims

The purpose of this study was to assess the reliability and responsiveness to hip surgery of a four-point modified Care and Comfort Hypertonicity Questionnaire (mCCHQ) scoring tool in children with cerebral palsy (CP) in Gross Motor Function Classification System (GMFCS) levels IV and V.

Methods

This was a population-based cohort study in children with CP from a national surveillance programme. Reliability was assessed from 20 caregivers who completed the mCCHQ questionnaire on two occasions three weeks apart. Test-retest reliability of the mCCHQ was calculated, and responsiveness before and after surgery for a displaced hip was evaluated in a cohort of children.


Bone & Joint 360
Vol. 13, Issue 3 | Pages 42 - 45
3 Jun 2024

The June 2024 Children’s orthopaedics Roundup360 looks at: Proximal femoral unicameral bone cysts: is ESIN the answer?; Hybrid-mesh casts in the conservative management of paediatric supracondylar humeral fractures: a randomized controlled trial; Rate and risk factors for contralateral slippage in adolescents treated for slipped capital femoral epiphysis; CRP predicts the need to escalate care after initial debridement for musculoskeletal infection; Genu valgum in paediatric patients presenting with patellofemoral instability; Nusinersen therapy changed the natural course of spinal muscular atrophy type 1: what about spine and hip?; The necessity of ulnar nerve exploration and translocation in open reduction of medial humeral epicondyle fractures in children.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 47 - 53
1 May 2024
Jones SA Parker J Horner M

Aims

The aims of this study were to determine the success of a reconstruction algorithm used in major acetabular bone loss, and to further define the indications for custom-made implants in major acetabular bone loss.

Methods

We reviewed a consecutive series of Paprosky type III acetabular defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical acetabular component. IIIB defects were planned to receive either a hemispherical acetabular component plus augments, a cup-cage reconstruction, or a custom-made implant. We used national digital health records and registry reports to identify any reoperation or re-revision procedure and Oxford Hip Score (OHS) for patient-reported outcomes. Implant survival was determined via Kaplan-Meier analysis.