Advertisement for orthosearch.org.uk
Results 1 - 20 of 164
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 36 - 42
1 Jan 2014
Liebs T Nasser L Herzberg W Rüther W Hassenpflug J

Several factors have been implicated in unsatisfactory results after total hip replacement (THR). We examined whether femoral offset, as measured on digitised post-operative radiographs, was associated with pain after THR. The routine post-operative radiographs of 362 patients (230 women and 132 men, mean age 70.0 years (35.2 to 90.5)) who received primary unilateral THRs of varying designs were measured after calibration. The femoral offset was calculated using the known dimensions of the implants to control for femoral rotation. Femoral offset was categorised into three groups: normal offset (within 5 mm of the height-adjusted femoral offset), low offset and high offset. We determined the associations to the absolute final score and the improvement in the mean Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain subscale scores at three, six, 12 and 24 months, adjusting for confounding variables. The amount of femoral offset was associated with the mean WOMAC pain subscale score at all points of follow-up, with the low-offset group reporting less WOMAC pain than the normal or high-offset groups (six months: 7.01 (. sd. 11.69) vs 12.26 (. sd. 15.10) vs 13.10 (. sd. 16.20), p = 0.006; 12 months: 6.55 (. sd. 11.09) vs 9.73 (. sd. 13.76) vs 13.46 (. sd. 18.39), p = 0.010; 24 months: 5.84 (. sd. 10.23) vs 9.60 (. sd. 14.43) vs 13.12 (. sd. 17.43), p = 0.004). When adjusting for confounding variables, including age and gender, the greatest improvement was seen in the low-offset group, with the normal-offset group demonstrating more improvement than the high-offset group. . Cite this article: Bone Joint J 2014;96-B:36–42


Bone & Joint Open
Vol. 3, Issue 10 | Pages 795 - 803
12 Oct 2022
Liechti EF Attinger MC Hecker A Kuonen K Michel A Klenke FM

Aims. Traditionally, total hip arthroplasty (THA) templating has been performed on anteroposterior (AP) pelvis radiographs. Recently, additional AP hip radiographs have been recommended for accurate measurement of the femoral offset (FO). To verify this claim, this study aimed to establish quantitative data of the measurement error of the FO in relation to leg position and X-ray source position using a newly developed geometric model and clinical data. Methods. We analyzed the FOs measured on AP hip and pelvis radiographs in a prospective consecutive series of 55 patients undergoing unilateral primary THA for hip osteoarthritis. To determine sample size, a power analysis was performed. Patients’ position and X-ray beam setting followed a standardized protocol to achieve reproducible projections. All images were calibrated with the KingMark calibration system. In addition, a geometric model was created to evaluate both the effects of leg position (rotation and abduction/adduction) and the effects of X-ray source position on FO measurement. Results. The mean FOs measured on AP hip and pelvis radiographs were 38.0 mm (SD 6.4) and 36.6 mm (SD 6.3) (p < 0.001), respectively. Radiological view had a smaller effect on FO measurement than inaccurate leg positioning. The model showed a non-linear relationship between projected FO and femoral neck orientation; at 30° external neck rotation (with reference to the detector plane), a true FO of 40 mm was underestimated by up to 20% (7.8 mm). With a neutral to mild external neck rotation (≤ 15°), the underestimation was less than 7% (2.7 mm). The effect of abduction and adduction was negligible. Conclusion. For routine THA templating, an AP pelvis radiograph remains the gold standard. Only patients with femoral neck malrotation > 15° on the AP pelvis view, e.g. due to external rotation contracture, should receive further imaging. Options include an additional AP hip view with elevation of the entire affected hip to align the femoral neck more parallel to the detector, or a CT scan in more severe cases. Cite this article: Bone Jt Open 2022;3(10):795–803


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 477 - 482
1 Apr 2012
Merle C Waldstein W Pegg E Streit MR Gotterbarm T Aldinger PR Murray DW Gill HS

The aim of this retrospective cohort study was to identify any difference in femoral offset as measured on pre-operative anteroposterior (AP) radiographs of the pelvis, AP radiographs of the hip and corresponding CT scans in a consecutive series of 100 patients with primary end-stage osteoarthritis of the hip (43 men and 57 women with a mean age of 61 years (45 to 74) and a mean body mass index of 28 kg/m. 2. (20 to 45)). Patients were positioned according to a standardised protocol to achieve reproducible projection and all images were calibrated. Inter- and intra-observer reliability was evaluated and agreement between methods was assessed using Bland-Altman plots. In the entire cohort, the mean femoral offset was 39.0 mm (95% confidence interval (CI) 37.4 to 40.6) on radiographs of the pelvis, 44.0 mm (95% CI 42.4 to 45.6) on radiographs of the hip and 44.7 mm (95% CI 43.5 to 45.9) on CT scans. AP radiographs of the pelvis underestimated femoral offset by 13% when compared with CT (p < 0.001). No difference in mean femoral offset was seen between AP radiographs of the hip and CT (p = 0.191). Our results suggest that femoral offset is significantly underestimated on AP radiographs of the pelvis but can be reliably and accurately assessed on AP radiographs of the hip in patients with primary end-stage hip osteoarthritis. We, therefore, recommend that additional AP radiographs of the hip are obtained routinely for the pre-operative assessment of femoral offset when templating before total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 865 - 869
1 Nov 1995
McGrory B Morrey B Cahalan T An K Cabanela M

At a minimum of one year after operation, we studied 64 patients with 86 total hip arthroplasties (THA) by standard anteroposterior hip and pelvic radiographs and measurement of range of motion and of isometric abduction strength. The femoral offset correlated positively with the range of abduction (p = 0.046). Abduction strength correlated positively with both femoral offset (p = 0.0001) and the length of the abductor lever arm (p = 0.005). Using multiple regression, abduction strength correlated with height (p = 0.017), gender (p = 0.0005), range of flexion (p = 0.047) and the abductor lever arm (p = 0.060). Our findings suggest that greater femoral offset after THA allows both an increased range of abduction and greater abductor strength


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1514 - 1525
1 Sep 2021
Scott CEH Holland G Gillespie M Keenan OJ Gherman A MacDonald DJ Simpson AHRW Clement ND

Aims. The aims of this study were to investigate the ability to kneel after total knee arthroplasty (TKA) without patellar resurfacing, and its effect on patient-reported outcome measures (PROMs). Secondary aims included identifying which kneeling positions were most important to patients, and the influence of radiological parameters on the ability to kneel before and after TKA. Methods. This prospective longitudinal study involved 209 patients who underwent single radius cruciate-retaining TKA without patellar resurfacing. Preoperative EuroQol five-dimension questionnaire (EQ-5D), Oxford Knee Score (OKS), and the ability to achieve four kneeling positions were assessed including a single leg kneel, a double leg kneel, a high-flexion kneel, and a praying position. The severity of radiological osteoarthritis (OA) was graded and the pattern of OA was recorded intraoperatively. The flexion of the femoral component, posterior condylar offset, and anterior femoral offset were measured radiologically. At two to four years postoperatively, 151 patients with a mean age of 70.0 years (SD 9.44) were included. Their mean BMI was 30.4 kg/m. 2. (SD 5.36) and 60 were male (40%). They completed EQ-5D, OKS, and Kujala scores, assessments of the ability to kneel, and a visual analogue scale for anterior knee pain and satisfaction. Results. The ability to kneel in the four positions improved in between 29 (19%) and 53 patients (35%) after TKA, but declined in between 35 (23%) and 46 patients (30%). Single-leg kneeling was most important to patients. After TKA, 62 patients (41%) were unable to achieve a single-leg kneel, 76 (50%) were unable to achieve a double-leg kneel, 102 (68%) were unable to achieve a high-flexion kneel and 61 (40%) were unable to achieve a praying position. Posterolateral cartilage loss significantly affected preoperative deep flexion kneeling (p = 0.019). A postoperative inability to kneel was significantly associated with worse OKS, Kujala scores, and satisfaction (p < 0.05). Multivariable regression analysis identified significant independent associations with the ability to kneel after TKA (p < 0.05): better preoperative EQ-5D and flexion of the femoral component for single-leg kneeling; the ability to achieve it preoperatively and flexion of the femoral component for double-leg kneeling; male sex for high-flexion kneeling; and the ability to achieve it preoperatively, anterior femoral offset, and patellar cartilage loss for the praying position. Conclusion. The ability to kneel was important to patients and significantly influenced knee-specific PROMs, but was poorly restored by TKA with equal chances of improvement or decline. Cite this article: Bone Joint J 2021;103-B(9):1514–1525


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 997 - 997
1 Nov 1996
SPALDING TJW


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 36 - 43
1 Jan 2018
Hambright D Hellman M Barrack R

Aims. The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging. Patients and Methods. A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image. Results. Digital imaging took a mean of five minutes (2.3 to 14.6) to perform. Intra-operative changes with the use of digital imaging were made for 43 patients (86%), most commonly to adjust leg length and femoral offset. There was a decrease in the incidence of outliers when using intra-operative imaging compared with not using it in regard to leg length discrepancy (20% versus 52%, p = 0.001) and femoral offset inequality (18% versus 44%, p = 0.004). There was also a difference in the incidence of outliers in acetabular inclination (0% versus 7%, p = 0.023) and version (0% versus 4%, p = 0.114) compared with historical results of a high-volume surgeon at the same centre. Conclusion. The use of intra-operative digital imaging in THA improves the accuracy of the positioning of the components at THA without adding a substantial amount of time to the operation. Cite this article: Bone Joint J 2018;100B(1 Supple A):36–43


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 17 - 24
1 May 2024
Anderson LA Wylie JD Kapron C Blackburn BE Erickson JA Peters CL

Aims. Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular procedures such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary cohort of patients, who underwent PAO in isolation without any intra-articular procedures. Methods. From June 2012 to March 2022, 349 rectus-sparing PAOs were performed and followed for a minimum of one year (mean 6.2 years (1 to 11)). The mean age was 24 years (14 to 46) and 88.8% were female (n = 310). Patients were evaluated at final follow-up for patient-reported outcome measures (PROMs). Clinical records were reviewed for complications or subsequent surgery. Radiographs were reviewed for the following acetabular parameters: lateral centre-edge angle, anterior centre-edge angle, acetabular index, and the alpha-angle (AA). Patients were cross-referenced from the two largest hospital systems in our area to determine if subsequent HA was performed. Descriptive statistics were used to analyze risk factors for HA. Results. A total of 16 hips (15 patients; 4.6%) underwent subsequent HA with labral repair and femoral osteochondroplasty, the most common interventions. For those with a minimum of two years of follow-up, 5.3% (n = 14) underwent subsequent HA. No hips underwent total hip arthroplasty and one revision PAO was performed. Overall, 17 hips (4.9%) experienced a complication and 99 (26.9%) underwent hardware removal. All PROMs improved significantly postoperatively. Radiologically, 80% of hips (n = 279) reached the goal for acetabular correction (77% for acetbular index and 93% for LCEA), with no significant differences between those who underwent subsequent HA and those who did not. Conclusion. Rectus-sparing PAO is associated with a low rate of subsequent HA for intra-articular pathology at a mean of 6.2 years’ follow-up (1 to 11). Acetabular correction alone may be sufficient as the primary intervention for the majority of patients with symptomatic acetabular dysplasia. Cite this article: Bone Joint J 2024;106-B(5 Supple B):17–24


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 163 - 166
1 Feb 2005
Loughead JM Chesney D Holland JP McCaskie AW

Hip resurfacing is being performed more frequently in the United Kingdom. The possible benefits include more accurate restoration of leg length, femoral offset and femoral anteversion than occurs after total hip arthroplasty (THA). We compared anteroposterior radiographs from 26 patients who had undergone hybrid THA (uncemented cup/cemented stem), with 28 who had undergone Birmingham Hip Resurfacing arthroplasty (BHR). We measured the femoral offset, femoral length, acetabular offset and acetabular height with reference to the normal contralateral hip. The data were analysed by paired t-tests. There was a significant reduction in femoral offset (p = 0.0004) and increase in length (p = 0.001) in the BHR group. In the THA group, there was a significant reduction in acetabular offset (p = 0.0003), but femoral offset and overall hip length were restored accurately. We conclude that hip resurfacing does not restore hip mechanics as accurately as THA


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 333 - 340
1 Mar 2009
Sariali E Mouttet A Pasquier G Durante E Catone Y

Pre-operative computerised three-dimensional planning was carried out in 223 patients undergoing total hip replacement with a cementless acetabular component and a cementless modular-neck femoral stem. Components were chosen which best restored leg length and femoral offset. The post-operative restoration of the anatomy was assessed by CT and compared with the pre-operative plan. The component implanted was the same as that planned in 86% of the hips for the acetabular implant, 94% for the stem, and 93% for the neck-shaft angle. The rotational centre of the hip was restored with a mean accuracy of 0.73 mm (. sd. 3.5) craniocaudally and 1.2 mm (. sd. 2) laterally. Limb length was restored with a mean accuracy of 0.3 mm (. sd. 3.3) and femoral offset with a mean accuracy of 0.8 mm (. sd. 3.1). This method appears to offer high accuracy in hip reconstruction as the difficulties likely to be encountered when restoring the anatomy can be anticipated and solved pre-operatively by optimising the selection of implants. Modularity of the femoral neck helped to restore the femoral offset and limb length


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 610 - 618
1 Apr 2021
Batailler C Bordes M Lording T Nigues A Servien E Calliess T Lustig S

Aims. Ideal component sizing may be difficult to achieve in unicompartmental knee arthroplasty (UKA). Anatomical variants, incremental implant size, and a reduced surgical exposure may lead to over- or under-sizing of the components. The purpose of this study was to compare the accuracy of UKA sizing with robotic-assisted techniques versus a conventional surgical technique. Methods. Three groups of 93 medial UKAs were assessed. The first group was performed by a conventional technique, the second group with an image-free robotic-assisted system (Image-Free group), and the last group with an image-based robotic arm-assisted system, using a preoperative CT scan (Image-Based group). There were no demographic differences between groups. We compared six parameters on postoperative radiographs to assess UKA sizing. Incorrect sizing was defined by an over- or under-sizing greater than 3 mm. Results. There was a higher rate of tibial under-sizing posteriorly in the conventional group compared to robotic-assisted groups (47.3% (n = 44) in conventional group, 29% (n = 27) in Image-Free group, 6.5% (n = 6) in Image-Based group; p < 0.001), as well as a higher rate of femoral under-sizing posteriorly (30.1% (n = 28) in conventional group, 7.5% (n = 7) in Image-Free group, 12.9% (n = 12) in Image-Based group; p < 0.001). The posterior femoral offset was more often increased in the conventional group, especially in comparison to the Image-Based group (43% (n = 40) in conventional group, 30.1% (n = 28) in Image-Free group, 8.6% (n = 8) in Image-Based group; p < 0.001). There was no significant overhang of the femoral or tibial implant in any groups. Conclusion. Robotic-assisted surgical techniques for medial UKA decrease the risk of tibial and femoral under-sizing, particularly with an image-based system using a preoperative CT scan. Cite this article: Bone Joint J 2021;103-B(4):610–618


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 721 - 726
1 Jun 2006
Girard J Lavigne M Vendittoli P Roy AG

We have compared the biomechanical nature of the reconstruction of the hip in conventional total hip arthroplasty (THA) and surface replacement arthroplasty (SRA) in a randomised study involving 120 patients undergoing unilateral primary hip replacement. The contralateral hip was used as a control. Post-operatively, the femoral offset was significantly increased with THA (mean 5.1 mm; −2.8 to 11.6) and decreased with SRA (mean −3.3 mm; −8.9 to 8.2). Femoral offset was restored within . sd. 4 mm in 14 (25%) of those with THA and in 28 (57%) of the patients receiving SRA (p < 0.001). In the THA group, the leg was lengthened by a mean of 2.6 mm (−6.04 to +12.9), whereas it was shortened by a mean of 1.9 mm (−7.1 to +2.05) in the SRA group, compared with the contralateral side. Leg-length inequality was restored within . sd. 4 mm in 42 (86%) of the SRA and 33 (60%) of the THA patients. The radiological parameters of acetabular reconstruction were similar in both groups. Restoration of the normal proximal femoral anatomy was more precise with SRA. The enhanced stability afforded by the use of a large-diameter femoral head avoided over-lengthening of the limb or increased offset to improve soft-tissue tension as occurs sometimes in THA. In a subgroup of patients with significant pre-operative deformity, restoration of the normal hip anatomy with lower pre-operative femoral offset or significant shortening of the leg was still possible with SRA


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 916 - 920
1 Jul 2005
Ebied A Hoad-Reddick DA Raut V

A reduced femoral offset in total hip replacement has been thought to be disadvantageous. We reviewed the results of 54 consecutive primary total hip replacements in 49 patients (mean age of 68 years) performed between August 1990 and December 1994, with a mean follow-up of 8.8 years (. sd. 2.1). The mean pre-operative femoral offset for these hips was 41 mm (. sd. 7.4). All patients received a low-offset Charnley stem and a polyethylene cup inserted by a single surgeon. At their latest follow-up, surviving patients had a significant improvement in the performance of their hip. Three had undergone revision, one each for deep infection, recurrent dislocation and late pain with subluxation. No hips had been revised, or were at risk of revision, for aseptic loosening. The mean annual linear rate of wear was 0.2 mm (. sd. 0.08) for the whole group. There was no correlation between the pre-operative femoral offset and the post-operative rate of wear. Our survivorship estimate was 91% when revision for any reason was taken as an end-point, but 100% if aseptic loosening was considered as the end-point. Our study demonstrates that a low-offset femoral stem can produce good, medium-term results


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 53 - 58
1 Jul 2021
Lawrie CM Bechtold D Schwabe M Clohisy JC

Aims. The direct anterior approach (DAA) for total hip arthroplasty (THA) has potential advantages over other approaches and is most commonly performed with the patient in the supine position. We describe a technique for DAA THA with the patient in the lateral decubitus position and report the early clinical and radiological outcomes, the characteristics of the learning curve, and perioperative complications. Methods. All primary DAA THAs performed in the lateral position by a single surgeon over a four-year period from the surgeon’s first case using the technique were identified from a prospectively collected database. Modified Harris Hip Scores (mHHS) were collected to assess clinical outcome, and routine radiological analysis was performed. Retrospective review of the medical records identified perioperative complications, the characteristics of the learning curve, and revisions. Results. A total of 257 patients were included in the study. Their mean age was 60 years (SD 9.0). A total of 164 (64%) were female. The mean mHHS improved significantly from 52.1 (SD 16.2) preoperatively to 94.4 (SD 11) at a follow-up of one year (p < 0.001), with 212 of 225 patients (94%) achieving a minimal clinically important difference (MCID) (> 8 points). Radiological evaluation showed a mean leg length discrepancy of 2.6 mm (SD 5.9) and a mean difference in femoral offset of 0.2 mm (SD 4.9). A total of 234/243 acetabular components (96.3%) were positioned within Lewinnek’s safe zone. Analysis of operating time, blood loss, the position of the components, and complications did not identify a learning curve. A total of 14 patients (5.4%) had a major perioperative complication and three (1.2%) required revision THA. There were no major neurovascular complications and no dislocations. Conclusion. We have described and analyzed a surgical technique for undertaking DAA THA in the familiar lateral decubitus position using a routine operating table, positioning devices, and instrumentation, and shown that it can be performed safely and effectively under these circumstances. Cite this article: Bone Joint J 2021;103-B(7 Supple B):53–58


Bone & Joint Open
Vol. 1, Issue 9 | Pages 594 - 604
24 Sep 2020
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases. Results. In total, 327 DHS and 248 hemiarthroplasty procedures were performed by 28 postgraduate year (PGY) 3 to 5 orthopaedic trainees during the 2014 to 2015 surgical training year at nine NHS hospitals in the West Midlands, UK. Overall, 109 PBAs were completed for DHS and 80 for hemiarthroplasty. Expert consensus identified four ‘final product analysis’ (FPA) radiological parameters of technical success for DHS: tip-apex distance (TAD); lag screw position in the femoral head; flushness of the plate against the lateral femoral cortex; and eight-cortex hold of the plate screws. Three parameters were identified for hemiarthroplasty: leg length discrepancy; femoral stem alignment; and femoral offset. Face validity, content validity, and feasibility were excellent. For all measurements, performance was better in the intermediate compared with the novice group, and this was statistically significant for TAD (p < 0.001) and femoral stem alignment (p = 0.023). Concurrent validity was poor when measured against global PBA score. This may be explained by the fact that they are measuring difference facets of competence. Intra-and inter-rater reliability were excellent for TAD, moderate for lag screw position (DHS), and moderate for leg length discrepancy (hemiarthroplasty). Use of a large multicentre dataset suggests good generalizability of the results to other settings. Assessment using FPA was time- and cost-effective compared with PBA. Conclusion. Final product analysis using post-implantation radiographs to measure technical skill in hip fracture surgery is feasible, valid, reliable, and cost-effective. It can complement traditional workplace-based assessment for measuring performance in the real-world operating room . It may have particular utility in competency-based training frameworks and for assessing skill transfer from the simulated to live operating theatre. Cite this article: Bone Joint Open 2020;1-9:594–604


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 839 - 844
1 Jul 2018
Ollivier M Laumonerie P LiArno S Faizan A Cavaignac E Argenson J

Aims. In patients where the proximal femur shows gross deformity due to degenerative changes or fracture, the contralateral femur is often used to perform preoperative templating for hip arthroplasty. However, femurs may not be symmetrical: the aim of this study was to determine the degree of variation between hips in healthy individuals and to determine whether it is affected by demographic parameters. Materials and Methods. CT-scan based modelling was used to examine the pelvis and bilateral femurs of 345 patients (211 males, 134 women; mean age 62 years (standard deviation (. sd). 17), mean body mass index 27 kg/m. 2. (. sd. 5)) representing a range of ethnicities. The femoral neck-shaft angle (NSA), femoral offset (FO), femoral neck version (FNV), femoral length (FL), femoral canal flare index (fCFI), and femoral head radius (FHr) were then determined for each patient. All measurements were constructed using algorithm-calculated landmarks, resulting in reproducible and consistent constructs for each specimen. We then analyzed femoral symmetry based on absolute differences (AD) and percentage asymmetry (%AS) following a previously validated method. Results. We found an asymmetry > 2% for NSA (mean AD 2.9°, mean %AS 2.3; p = 0.03), FO (AD 3.8 mm, %AS 9.1 ; p = 0.01), FNV (AD 5.1°, %AS 46.7 ; p = 0.001) and fCFI (AD 0.2 mm, %AS 5.4 ; p = 0.7). Significant relationships were found for AD regarding NSA and ethnicity (p = 0.037), FL and height (R. 2.  = 0.22), and fCFI and gender (R. 2.  = 0.34). Conclusion. Our data confirm the presence of asymmetry of proximal femurs, which is mostly independent of demographic parameters. In cases where contralateral templating is used, such asymmetry may lead to inaccurate anatomical restoration of the hip if the templated sizes are routinely implanted. However, the clinical impact cannot be determined from our investigation. Cite this article: Bone Joint J 2018;100-B:839–44


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 529 - 535
1 May 2019
Jacobs CA Kusema ET Keeney BJ Moschetti WE

Aims. The hypothesis of this study was that thigh circumference, distinct from body mass index (BMI), may be associated with the positioning of components when undertaking total hip arthroplasty (THA) using the direct anterior approach (DAA), and that an increased circumference might increase the technical difficulty. Patients and Methods. We performed a retrospective review of prospectively collected data involving 155 consecutive THAs among 148 patients undertaken using the DAA at an academic medical centre by a single fellowship-trained surgeon. Preoperatively, thigh circumference was measured at 10 cm, 20 cm, and 30 cm distal to the anterior superior iliac spine, in quartiles. Two blinded reviewers assessed the inclination and anteversion of the acetabular component, radiological leg-length discrepancy, and femoral offset. The radiological outcomes were considered as continuous and binary outcome variables based on Lewinnek’s ‘safe zone’. Results. Similar trends were seen in all three thigh circumference groups. In multivariable analyses, patients in the largest 20 cm thigh circumference quartile (59 cm to 78 cm) had inclination angles that were a mean of 5.96° larger (95% confidence interval (CI) 2.99° to 8.93°; p < 0.001) and anteversion angles that were a mean of 2.92° larger (95% CI 0.47° to 5.37°; p = 0.020) than the smallest quartile. No significant differences were noted in leg-length discrepancy or offset. Conclusion. There was an associated increase in inclination and anteversion as thigh circumference increased, with no change in the risk of malpositioning the components. THA can be performed using the DAA in patients with large thigh circumference without the risk of malpositioning the acetabular component. Cite this article: Bone Joint J 2019;101-B:529–535


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1140 - 1146
1 Sep 2017
Shoji T Yamasaki T Izumi S Murakami H Mifuji K Sawa M Yasunaga Y Adachi N Ochi M

Aims. Our aim was to evaluate the radiographic characteristics of patients undergoing total hip arthroplasty (THA) for the potential of posterior bony impingement using CT simulations. Patients and Methods. Virtual CT data from 112 patients who underwent THA were analysed. There were 40 men and 72 women. Their mean age was 59.1 years (41 to 76). Associations between radiographic characteristics and posterior bony impingement and the range of external rotation of the hip were evaluated. In addition, we investigated the effects of pelvic tilt and the neck/shaft angle and femoral offset on posterior bony impingement. Results. The range of external rotation and the ischiofemoral length were significantly lower, while femoral anteversion, the ischial ratio, and ischial angle were significantly higher in patients with posterior bony impingement compared with those who had implant impingement (p <  0.05). The range of external rotation positively correlated with ischiofemoral length (r = 0.49, p < 0.05), and negatively correlated with ischial length (r = -0.49, p < 0.05), ischial ratio (r =- 0.49, p < 0.05) and ischial angle (r = -0.55, p < 0.05). The range of external rotation was lower in patients with posterior pelvic tilt (p < 0.05) and in those with a high offset femoral component (p < 0.05) due to posterior bony impingement. Conclusion. Posterior bony impingement after THA is more likely in patients with a wider ischium and a narrow ischiofemoral space. A high femoral offset and posterior pelvic tilt are also risk factors for this type of impingement. Cite this article: Bone Joint J 2017;99-B:1140–6


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 310 - 316
1 Mar 2017
Hothi H Henckel J Shearing P Holme T Cerquiglini A Laura AD Atrey A Skinner J Hart A

Aims. The aim of this study was to compare the design of the generic OptiStem XTR femoral stem with the established Exeter femoral stem. Materials and Methods. We obtained five boxed, as manufactured, implants of both designs at random (ten in total). Two examiners were blinded to the implant design and independently measured the mass, volume, trunnion surface topography, trunnion roughness, trunnion cone angle, Caput-Collum-Diaphyseal (CCD) angle, femoral offset, stem length, neck length, and the width and roughness of the polished stem shaft using peer-reviewed methods. We then compared the stems using these parameters. Results. We found that the OptiStems were lighter (p < 0.001), had a rougher trunnion surface (p <  0.001) with a greater spacing and depth of the machined threads (p < 0.001), had greater trunnion cone angles (p = 0.007), and a smaller radius at the top of the trunnion (p = 0.007). There was no difference in stem volume (p = 0.643), CCD angle (p = 0.788), offset (p = 0.993), neck length (p = 0.344), stem length (p = 0.808), shaft width (p = 0.058 to 0.720) or roughness of the polished surface (p = 0.536). Conclusion. This preliminary investigation found that whilst there were similarities between the two designs, the generic OptiStem is different to the branded Exeter design. Cite this article: Bone Joint J 2017;99-B:310–16


Bone & Joint 360
Vol. 3, Issue 2 | Pages 8 - 9
1 Apr 2014

The April 2014 Hip & Pelvis Roundup. 360 . looks at: Recent arthroplasty and flight; whether that squeak could be a fracture; diagnosing early infected hip replacement; impaction grafting at a decade; whether squeaking is more common than previously thought; femoral offset associated with post THR outcomes; and periprosthetic fracture stabilisation