The aim of this study was to define the incidence
of venous thromboembolism (VTE) and risk factors for the development
of deep-vein thrombosis (DVT) after the resection of a musculoskeletal
tumour. A total of 94 patients who underwent resection of a musculoskeletal
tumour between January 2003 and December 2005 were prospectively
studied. There were 42 men and 52 women with a mean age of 54.4
years (18 to 86). All patients wore intermittent pneumatic compression
devices and graduated compression stockings. Ultrasound examination
of the lower limbs was conducted to screen for DVT between the fifth
and ninth post-operative days. DVT was detected in 21 patients (22%). Of these, two were symptomatic
(2%). One patient (1%) had a fatal pulmonary embolism. Patients
aged ≥ 70 years had an increased risk of DVT (p = 0.004). The overall incidence of DVT (both symptomatic and asymptomatic)
after resection of a
Aims. We analyzed the long-term outcomes of patients observed over ten years after resection en bloc and reconstruction with extracorporeal irradiated autografts. Patients and Methods. This retrospective study included 27 patients who underwent resection en bloc and reimplantation of an extracorporeal irradiated autograft. The mean patient age and follow-up period were 31.7 years (9 to 59) and 16.6 years (10.3 to 24.3), respectively. The most common diagnosis was osteosarcoma (n = 10), followed by chondrosarcoma (n = 6). The femur (n = 13) was the most frequently involved site, followed by the tibia (n = 7). There were inlay grafts in five patients, intercalary grafts in 15 patients, and osteoarticular grafts in seven patients. Functional outcome was evaluated with the
Aims. Tenosynovial giant cell tumour (TGCT) is a rare benign tumour of the musculoskeletal system. Surgical management is fraught with challenges due to high recurrence rates. The aim of this study was to describe surgical treatment and evaluate surgical outcomes of TGCT at an Australian tertiary referral centre for
Patients who have limb amputation for musculoskeletal
tumours are a rare group of cancer survivors. This was a prospective
cross-sectional survey of patients from five specialist centres
for sarcoma surgery in England. Physical function, pain and quality
of life (QOL) outcomes were collected after lower extremity amputation
for bone or soft-tissue tumours to evaluate the survivorship experience
and inform service provision. Of 250 patients, 105 (42%) responded between September 2012 and
June 2013. From these, completed questionnaires were received from
100 patients with a mean age of 53.6 years (19 to 91). In total
60 (62%) were male and 37 (38%) were female (three not specified).
The diagnosis was primary bone sarcoma in 63 and soft-tissue tumour
in 37. A total of 20 tumours were located in the hip or pelvis,
31 above the knee, 32 between the knee and ankle and 17 in the ankle
or foot. In total 22 had hemipelvectomy, nine hip disarticulation,
35 transfemoral amputation, one knee disarticulation, 30 transtibial
amputation, two toe amputations and one rotationplasty. The Toronto
Extremity Salvage Score (TESS) differed by amputation level, with
poorer scores at higher levels (p <
0.001). Many reported significant
pain. In addition, TESS was negatively associated with increasing
age, and pain interference scores. QOL for Cancer Survivors was
significantly correlated with TESS (p <
0.001). This relationship appeared
driven by pain interference scores. This unprecedented national survey confirms amputation level
is linked to physical function, but not QOL or pain measures. Pain
and physical function significantly impact on QOL. These results
are helpful in managing the expectations of patients about treatment
and addressing their complex needs. Cite this article:
Resection of a primary sarcoma of the diaphysis
of a long bone creates a large defect. The biological options for reconstruction
include the use of a vascularised and non-vascularised fibular autograft. The purpose of the present study was to compare these methods
of reconstruction. Between 1985 and 2007, 53 patients (26 male and 27 female) underwent
biological reconstruction of a diaphyseal defect after resection
of a primary sarcoma. Their mean age was 20.7 years (3.6 to 62.4).
Of these, 26 (49 %) had a vascularised and 27 (51 %) a non-vascularised
fibular autograft. Either method could have been used for any patient in
the study. The mean follow-up was 52 months (12 to 259). Oncological,
surgical and functional outcome were evaluated. Kaplan–Meier analysis
was performed for graft survival with major complication as the
end point. At final follow-up, eight patients had died of disease. Primary
union was achieved in 40 patients (75%); 22 (42%) with a vascularised
fibular autograft and 18 (34%) a non-vascularised (p = 0.167). A
total of 32 patients (60%) required revision surgery. Kaplan–Meier
analysis revealed a mean survival without complication of 36 months
(0.06 to 107.3, Both groups seem to be reliable biological methods of reconstructing
a diaphyseal bone defect. Vascularised autografts require more revisions
mainly due to problems with wound healing in distal sites of tumour,
such as the foot. Cite this article:
To evaluate mid-to long-term patient-reported outcome measures (PROMs) of endoprosthetic reconstruction after resection of malignant tumours arising around the knee, and to investigate the risk factors for unfavourable PROMs. The medical records of 75 patients who underwent surgery between 2000 and 2020 were retrospectively reviewed, and 44 patients who were alive and available for follow-up (at a mean of 9.7 years postoperatively) were included in the study. Leg length discrepancy was measured on whole-leg radiographs, and functional assessment was performed with PROMs (Toronto Extremity Salvage Score (TESS) and Comprehensive Outcome Measure for Musculoskeletal Oncology Lower Extremity (COMMON-LE)) with two different aspects. The thresholds for unfavourable PROMs were determined using anchor questions regarding satisfaction, and the risk factors for unfavourable PROMs were investigated.Aims
Methods
The most appropriate protocol for the biopsy of
Aims. The aim of this study was to investigate the safety and efficacy of 3D-printed modular prostheses in patients who underwent joint-sparing limb salvage surgery (JSLSS) for malignant femoral diaphyseal bone tumours. Methods. We retrospectively reviewed 17 patients (13 males and four females) with femoral diaphyseal tumours who underwent JSLSS in our hospital. Results. In all, 17 patients with locally aggressive bone tumours (Enneking stage IIB) located in the femoral shaft underwent JSLSS and reconstruction with 3D-printed modular prostheses between January 2020 and June 2022. The median surgical time was 153 minutes (interquartile range (IQR) 117 to 248), and the median estimated blood loss was 200ml (IQR 125 to 400). Osteosarcoma was the most common pathological type (n = 12; 70.6%). The mean osteotomy length was 197.53 mm (SD 12.34), and the median follow-up was 25 months (IQR 19 to 38). Two patients experienced local recurrence and three developed distant metastases. Postoperative complications included wound infection in one patient and screw loosening in another, both of which were treated successfully with revision surgery. The median
Aims. The ulna is an extremely rare location for primary bone tumours of the elbow in paediatrics. Although several reconstruction options are available, the optimal reconstruction method is still unknown due to the rarity of proximal ulna tumours. In this study, we report the outcomes of osteoarticular ulna allograft for the reconstruction of proximal ulna tumours. Methods. Medical profiles of 13 patients, who between March 2004 and November 2021 underwent osteoarticular ulna allograft reconstruction after the resection of the proximal ulna tumour, were retrospectively reviewed. The outcomes were measured clinically by the assessment of elbow range of motion (ROM), stability, and function, and radiologically by the assessment of allograft-host junction union, recurrence, and joint degeneration. The elbow function was assessed objectively by the
Aims. Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes. Methods. This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the
Aims. For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis. Methods. We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan. Results. Postoperative pathological assessment revealed a negative surgical margin was achieved in all patients. At final follow-up, 13.3% (2/15) died and no recurrence occurred. The overall survival was 81.7% at five years. None of the patients showed any signs of aseptic loosening, and no wound healing issues were observed. In total, 20% (3/15) developed complications, with two cases of early hip dislocation and one case of deep infection. The cumulative incidence of mechanical and non-mechanical failure in this series was 13.7% and 9.3%, respectively, at five years. In this cohort, the mean time to full weightbearing was 5.89 (SD 0.92) weeks and the mean
Aims. Ilium is the most common site of pelvic Ewing’s sarcoma (ES). Resection of the ilium and iliosacral joint causes pelvic disruption. However, the outcomes of resection and reconstruction are not well described. In this study, we report patients’ outcomes after resection of the ilium and iliosacral ES and reconstruction with a tibial strut allograft. Methods. Medical files of 43 patients with ilium and iliosacral ES who underwent surgical resection and reconstruction with a tibial strut allograft between January 2010 and October 2021 were reviewed. The lesions were classified into four resection zones: I. 1. , I. 2. , I. 3. , and I. 4. , based on the extent of resection. Functional outcomes, oncological outcomes, and surgical complications for each resection zone were of interest. Functional outcomes were assessed using a
Aims. Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children. Methods. A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the
Aims. The scapula is a rare site for a primary bone tumour. Only a small number of series have studied patient outcomes after treatment. Previous studies have shown a high rate of recurrence, with functional outcomes determined by the preservation of the glenohumeral joint and deltoid. The purpose of the current study was to report the outcome of patients who had undergone tumour resection that included the scapula. Methods. We reviewed 61 patients (37 male, 24 female; mean age 42 years (SD 19)) who had undergone resection of the scapula. The most common resection was type 2 (n = 34) according to the Tikhoff-Linberg classification, or type S1A (n = 35) on the Enneking classification. Results. The ten-year disease-specific survival was 76%. High tumour grade (hazard ratio (HR) 4.27; p = 0.016) and a total resection of the scapula (HR 3.84; p = 0.015) were associated with worse survival. The ten-year metastasis-free and local recurrence-free survivals were 82% and 86%, respectively. Total scapular resection (HR 6.29; p = 0.004) was associated with metastatic disease and positive margins were associated with local recurrence (HR 12.86; p = 0.001). At final follow-up, the mean shoulder forward elevation and external rotation were 79° (SD 62°) and 27° (SD 25°), respectively. The most recent functional outcomes evaluated included the mean
Aims. The sacroiliac joint (SIJ) is the only mechanical connection between the axial skeleton and lower limbs. Following iliosacral resection, there is debate on whether reconstruction of the joint is necessary. There is a paucity of data comparing the outcomes of patients undergoing reconstruction and those who are not formally reconstructed. Methods. A total of 60 patients (25 females, 35 males; mean age 39 years (SD 18)) undergoing iliosacral resection were reviewed. Most resections were performed for primary malignant tumours (n = 54; 90%). The mean follow-up for surviving patients was nine years (2 to 19). Results. Overall, 27 patients (45%) were reconstructed, while 33 (55%) had no formal reconstruction. There was no difference in the use of chemotherapy (p = 1.000) or radiotherapy (p = 0.292) between the groups. Patients with no reconstruction had a mean larger tumour (11 cm (SD 5) vs 8 cm (SD 4); p = 0.014), mean shorter operating times (664 mins (SD 195) vs 1,324 mins (SD 381); p = 0.012), and required fewer blood units (8 (SD 7) vs 14 (SD 11); p = 0.012). Patients undergoing a reconstruction were more likely to have a deep infection (48% vs 12%; p = 0.003). Nine reconstructed patients had a hardware failure, with five requiring revision. Postoperatively 55 (92%) patients were ambulatory, with no difference in the proportion of ambulatory patients (89% vs 94%; p = 0.649) or mean
Aims. The epiphyseal approach to a chondroblastoma of the intercondylar notch of a child’s distal femur does not provide adequate exposure, thereby necessitating the removal of a substantial amount of unaffected bone to expose the lesion. In this study, we compared the functional outcomes, local recurrence, and surgical complications of treating a chondroblastoma of the distal femoral epiphysis by either an intercondylar or an epiphyseal approach. Methods. A total of 30 children with a chondroblastoma of the distal femur who had been treated by intraregional curettage and bone grafting were retrospectively reviewed. An intercondylar approach was used in 16 patients (group A) and an epiphyseal approach in 14 (group B). Limb function was assessed using the
Aims. The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection. Methods. From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients. Results. Preparation of the prosthesis was a mean of 8.0 days (SD 1.5), during which time no patients experienced tumour progression. The mean operating time and intraoperative blood loss were 158.1 minutes (SD 67.6) and 176.9 ml (SD 187.8), respectively. All of the prostheses were implanted successfully. During a mean follow-up of 25.7 months (SD 7.8), no patients died, but four had complications (two superficial wound problems, one temporary palsy of radial nerve, and one dislocation). No aseptic loosening, structural failure, infection, heterotopic ossification, or degenerative arthritis was seen in this study. The mean flexion of the elbow was 119.6° (SD 15.9°) and the mean extension lag was 11.9° (SD 13.8°). The mean
Aims. We have previously reported cryoablation-assisted joint-sparing surgery for osteosarcoma with epiphyseal involvement. However, it is not clear whether this is a comparable alternative to conventional joint arthroplasty in terms of oncological and functional outcomes. Methods. A total of 22 patients who had localized osteosarcoma with epiphyseal involvement around the knee and underwent limb salvage surgery were allocated to joint preservation (JP) group and joint arthroplasty (JA) group. Subjects were followed with radiographs,
Aims. The primary objective of this study was to compare the postoperative infection rate between negative pressure wound therapy (NPWT) and conventional dressings for closed incisions following soft-tissue sarcoma (STS) surgery. Secondary objectives were to compare rates of adverse wound events and functional scores. Methods. In this prospective, single-centre, randomized controlled trial (RCT), patients were randomized to either NPWT or conventional sterile occlusive dressings. A total of 17 patients, with a mean age of 54 years (21 to 81), were successfully recruited and none were lost to follow-up. Wound reviews were undertaken to identify any surgical site infection (SSI) or adverse wound events within 30 days. The Toronto Extremity Salvage Score (TESS) and
Aims. Giant cell tumours (GCTs) of the proximal femur are rare, and there is no consensus about the best method of filling the defect left by curettage. In this study, we compared the outcome of using a fibular strut allograft and bone cement to reconstruct the bone defect after extended curettage of a GCT of the proximal femur. Methods. In a retrospective study, we reviewed 26 patients with a GCT of the proximal femur in whom the bone defect had been filled with either a fibular strut allograft (n = 12) or bone cement (n = 14). Their demographic details and oncological and nononcological complications were retrieved from their medical records. Limb function was assessed using the