Advertisement for orthosearch.org.uk
Results 1 - 20 of 31
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1678 - 1683
1 Dec 2012
Foster PAL Barton SB Jones SCE Morrison RJM Britten S

We report on the use of the Ilizarov method to treat 40 consecutive fractures of the tibial shaft (35 AO 42C fractures and five AO 42B3 fractures) in adults. There were 28 men and 12 women with a mean age of 43 years (19 to 81). The series included 19 open fractures (six Gustilo grade 3A and 13 grade 3B) and 21 closed injuries. The mean time from injury to application of definitive Ilizarov frame was eight days (0 to 35) with 36 fractures successfully uniting without the need for any bone-stimulating procedure. The four remaining patients with nonunion healed with a second frame. There were no amputations and no deep infections. None required intervention for malunion. The total time to healing was calculated from date of injury to removal of the frame, with a median of 166 days (mean 187, (87 to 370)). Minor complications included snapped wires in two patients and minor pin-site infections treated with oral antibiotics in nine patients (23%). Clinical scores were available for 32 of the 40 patients at a median of 55 months (mean 62, (26 to 99)) post-injury, with ‘good’ Olerud and Molander ankle scores (median 80, mean 75, (10 to 100)), ‘excellent’ Lysholm knee scores (median 97, mean 88, (29 to 100)), a median Tegner activity score of 4 (mean 4, (0 to 9)) (comparable to ‘moderately heavy labour / cycling and jogging’) and Short Form-12 scores that exceeded the mean of the population as a whole (median physical component score 55 (mean 51, (20 to 64)), median mental component score 57 (mean 53, (21 to 62)). In conclusion, the Ilizarov method is a safe and reliable way of treating complex tibial shaft fractures with a high rate of primary union


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1693 - 1697
1 Dec 2015
Keightley AJ Nawaz SZ Jacob JT Unnithan A Elliott DS Khaleel A

This study aimed to determine the long-term functional, clinical and radiological outcomes in patients with Schatzker IV to VI fractures of the tibial plateau treated with an Ilizarov frame. Clinical, functional and radiological assessment was carried out at a minimum of one year post-operatively. A cohort of 105 patients (62 men, 43 women) with a mean age of 49 years (15 to 87) and a mean follow-up of 7.8 years (1 to 19) were reviewed. There were 18 type IV, 10 type V and 77 type VI fractures. All fractures united with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient developed a deep infection. The median range of movement (ROM) of the knee was 110. o. and the median Iowa score was 85. . Our study demonstrates good long-term functional outcome with no deep infection; spanning the knee had no detrimental effect on the ROM or functional outcome. . High-energy fractures of the tibial plateau may be treated effectively with a fine wire Ilizarov fixator. Cite this article: Bone Joint J 2015;97-B:1693–7


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 232 - 237
1 Feb 2006
Saridis A Panagiotopoulos E Tyllianakis M Matzaroglou C Vandoros N Lambiris E

We reviewed 13 patients with infected nonunion of the distal femur and bone loss, who had been treated by radical surgical debridement and the application of an Ilizarov external fixator. All had severely restricted movement of the knee and a mean of 3.1 previous operations. The mean length of the bony defect was 8.3 cm and no patient was able to bear weight. The mean external fixation time was 309.8 days. According to Paley’s grading system, eight patients had an excellent clinical and radiological result and seven excellent and good functional results. Bony union, the ability to bear weight fully, and resolution of the infection were achieved in all the patients. The external fixation time was increased when the definitive treatment started six months or more after the initial trauma, the patient had been subjected to more than four previous operations and the initial operation had been open reduction and internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 273 - 279
1 Mar 1997
Marsh DR Shah S Elliott J Kurdy N

We have reviewed a series of 56 consecutive patients treated by the Ilizarov circular fixator for various combinations of nonunion, malunion and infection of fractures. We used segmental excision, distraction osteogenesis and gradual correction of the deformity as appropriate. Treatment was effective in eliminating 40 out of 46 nonunions and all 22 infections. There were two cases of refracture some months after removal of the frame, both of which healed securely in a second frame. Correction of malunion was good in the coronal plane but there was a tendency to anterior angulation, often occurring in the regenerate bone rather than at the original fracture site, after removal of the frame. This was associated with very slow maturation of regenerate bone in some patients, occurring largely, but not exclusively, in those who smoked heavily. Patients expressed high levels of satisfaction with the outcome, despite relatively modest improvements in pain and function, presumably because their longstanding and intractable nonunion had been treated. None the less, the degree of satisfaction correlated strongly with the degree of improvement in pain and function. We emphasise the importance of a multidisciplinary team in the assessment and support of patients undergoing long and demanding treatment. The Ilizarov method is valuable, but research is needed to overcome the problems of delayed maturation of the regenerate and slow or insecure healing of the docking site


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 710 - 717
1 Sep 1996
Dendrinos GK Kontos S Katsenis D Dalas A

We treated 24 patients with high-energy fractures of the tibial plateau by the Ilizarov fixator and transfixion wires. Eleven fractures were open, and 20 patients had complex injuries. Twelve were treated by ligamentotaxis and percutaneous fixation, seven by limited open reduction and five by extensive open reduction. All were followed for at least 24 months. All the fractures united, with an average time to healing of 14.4 weeks. Thirteen patients achieved full extension and 13 more than 110° of flexion. Twenty-two knees were stable. Fifteen patients walked normally and the rest with only a slight limp. All but two knees had an articular step-off of less than 4 mm and all had normal axial alignment except two. There were no cases of postoperative skin infection, osteomyelitis or septic arthritis. Ilizarov circular fixation is an ideal method of treatment for these fractures when extensive dissection and internal fixation are contraindicated due to trauma to the soft tissue, deficiency of bone stock, and bony comminution


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 663 - 667
1 Jul 2001
Arazi M Memik R Ögün TC Yel M

Our aim was to determine the clinical effectiveness and safety of Ilizarov external fixation for the acute treatment of severely comminuted extra-articular and intercondylar fractures of the distal femur. A total of 14 consecutive patients with complex fractures was treated. There were three type-A3, two type-C2 and nine type-C3 fractures according to the AO/ASIF system. The mean follow-up was 14 months. Most fractures (13) united primarily at a mean of 16 weeks. One patient with a type-IIIA open fracture had infection and nonunion. The mean range of flexion of the knee at the final follow-up was 105° (35 to 130). We conclude that, in the treatment of comminuted fractures of the distal femur, the Ilizarov fixator is safe and effective in providing stability and allowing early rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 748 - 752
1 Sep 1997
Song H Cho S Jeong S Park Y Koo K

Stable fixation after a corrective supracondylar osteotomy in adults is difficult because of the irregularity of the area of bony contact, displacement of the fragments, the predominance of cortical bone, and the need for early mobilisation. We have used the Ilizarov apparatus for fixation in 15 patients who were treated by complex osteotomies with displacement of fragments for cubitus varus or valgus. Most patients with cubitus varus required medial displacement with rotation of the distal fragment. Those with cubitus valgus required lateral shift of the distal fragment to reduce the medial prominence of the elbow that would otherwise result. All osteotomies united within the expected time without loss of correction, despite early mobilisation. Complications related to the fixation were few and had resolved at the long-term follow-up


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 162 - 169
1 Feb 2019
Catagni MA Azzam W Guerreschi F Lovisetti L Poli P Khan MS Di Giacomo LM

Aims

Many authors have reported a shorter treatment time when using trifocal bone transport (TFT) rather than bifocal bone transport (BFT) in the management of long segmental tibial bone defects. However, the difference in the incidence of additional procedures, the true complications, and the final results have not been investigated.

Patients and Methods

A total of 86 consecutive patients with a long tibial bone defect (≥ 8 cm), who were treated between January 2008 and January 2015, were retrospectively reviewed. A total of 45 were treated by BFT and 41 by TFT. The median age of the 45 patients in the BFT group was 43 years (interquartile range (IQR) 23 to 54).


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 279 - 285
1 Feb 2021
Ferguson D Harwood P Allgar V Roy A Foster P Taylor M Moulder E Sharma H

Aims

Pin-site infection remains a significant problem for patients treated by external fixation. A randomized trial was undertaken to compare the weekly use of alcoholic chlorhexidine (CHX) for pin-site care with an emollient skin preparation in patients with a tibial fracture treated with a circular frame.

Methods

Patients were randomized to use either 0.5% CHX or Dermol (DML) 500 emollient pin-site care. A skin biopsy was taken from the tibia during surgery to measure the dermal and epidermal thickness and capillary, macrophage, and T-cell counts per high-powered field. The pH and hydration of the skin were measured preoperatively, at follow-up, and if pin-site infection occurred. Pin-site infection was defined using a validated clinical system.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 928 - 932
1 Jul 2006
Patil S Montgomery R

We reviewed 78 femoral and tibial nonunions treated between January 1992 and December 2003. Of these, we classified 41 in 40 patients as complex cases because of infection (22), bone loss (6) or failed previous surgery (13). The complex cases were all treated with Ilizarov frames. At a mean time of 14.1 months (4 to 38), 39 had healed successfully. Using the Association for the Study and Application of the Methods of Ilizarov scoring system we obtained 17 excellent, 14 good, four fair and six poor bone results. The functional results were excellent in 14 patients, good in 14, fair in two and poor in two. A total of six patients were lost to follow-up and two had amputations so were not evaluated for final functional assessment. All but two patients were very satisfied with the results. The average cost of treatment to the treating hospital was approximately £30 000 per patient. We suggest that early referral to a tertiary centre could reduce the morbidity and prolonged time off work for these patients. The results justify the expense, but the National Health Service needs to make financial provision for the reconstruction of this type of complex nonunion


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1094 - 1099
1 Aug 2018
Gupta S Malhotra A Mittal N Garg SK Jindal R Kansay R

Aims. The aims of this study were to establish whether composite fixation (rail-plate) decreases fixator time and related problems in the management of patients with infected nonunion of tibia with a segmental defect, without compromising the anatomical and functional outcomes achieved using the classical Ilizarov technique. We also wished to study the acceptability of this technique using patient-based objective criteria. Patients and Methods. Between January 2012 and January 2015, 14 consecutive patients were treated for an infected nonunion of the tibia with a gap and were included in the study. During stage one, a radical debridement of bone and soft tissue was undertaken with the introduction of an antibiotic-loaded cement spacer. At the second stage, the tibia was stabilized using a long lateral locked plate and a six-pin monorail fixator on its anteromedial surface. A corticotomy was performed at the appropriate level. During the third stage, i.e. at the end of the distraction phase, the transported fragment was aligned and fixed to the plate with two to four screws. An iliac crest autograft was added to the docking site and the fixator was removed. Functional outcome was assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) score. Results. The mean age of patients was 38.1 years (. sd. 12.7). There were 13 men and one woman. The mean size of the defect was 6.4 cm (. sd. 1.3). the mean follow-up was 33.2 months (24 to 50). The mean external fixator index was 21.2 days/cm (. sd. 1.5). The complication rate was 0.5 (7/14) per patient. According to the classification of Paley, there were five problems and two obstacles but no true complications. The ASAMI bone score was excellent in all patients. The functional ASAMI scores were excellent in eight and good in six patients. The mean MSTS composite score was 83.9% (. sd. 7.1), with an MSTS emotional acceptance score of 4.9 (. sd. 0.5; maximum possible 5). Conclusion. Composite fixation (rail-plate) decreases fixator time and the associated complications, in the treatment of patients of infected nonunion tibia with a segmental defect. It also provides good anatomical and functional results with high emotional acceptance. Cite this article: Bone Joint J 2018;100-B:1094–9


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 494 - 502
1 Apr 2017
Simpson AHRW Keenan G Nayagam S Atkins RM Marsh D Clement ND

Aims. The aim of this double-blind prospective randomised controlled trial was to assess whether low intensity pulsed ultrasound (LIPUS) accelerated or enhanced the rate of bone healing in adult patients undergoing distraction osteogenesis. Patients and Methods. A total of 62 adult patients undergoing limb lengthening or bone transport by distraction osteogenesis were randomised to treatment with either an active (n = 32) or a placebo (n = 30) ultrasound device. A standardised corticotomy was performed in the proximal tibial metaphysis and a circular Ilizarov frame was used in all patients. The rate of distraction was also standardised. The primary outcome measure was the time to removal of the frame after adjusting for the length of distraction in days/cm for both the per protocol (PP) and the intention-to-treat (ITT) groups. The assessor was blinded to the form of treatment. A secondary outcome was to identify covariates affecting the time to removal of the frame. Results. There was no difference in the time to removal of the frame between the PP (difference in favour of the control group was 10.1 days/cm, 95% confidence interval (CI) -3.2 to 23.4, p = 0.054) or ITT (difference 5.0 days/cm, 95% CI -8.2 to 18.21, p = 0.226) groups. The smoking status was the only covariate which increased the time to removal of the frame (hazard ratio 0.47, 95% CI 0.22 to 0.97, p = 0.042). Conclusion. LIPUS does not influence the rate of bone healing in patients who undergo distraction osteogenesis. Smoking may influence bone healing. . Cite this article: Bone Joint J 2017;99-B:494–502


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1399 - 1405
1 Oct 2016
Rohilla R Wadhwani J Devgan A Singh R Khanna M

Aims. This is a prospective randomised study which compares the radiological and functional outcomes of ring and rail fixators in patients with an infected gap (> 3 cm) nonunion of the tibia. Patients and Methods. Between May 2008 and February 2013, 70 patients were treated at our Institute for a posttraumatic osseocutaneous defect of the tibia measuring at least 3 cm. These were randomised into two groups of 35 patients using the lottery method. Group I patients were treated with a ring fixator and group II patients with a rail fixator. The mean age was 33.2 years (18 to 64) in group I and 29.3 years (18 to 65) in group II. The mean bone gap was 5.84 cm in group I and 5.78 cm in group II. The mean followup was 33.8 months in group I and 32.6 months in group II. Bone and functional results were assessed using the classification of the Association for the Study and Application of the Method of Ilizarov (ASAMI). Functional results were also assessed at six months using the short musculoskeletal functional assessment (SMFA) score. Results. The bone result was excellent, good, fair and poor in 21, 12, 0 and 2 in group I; and 14, 15, 3, and 3 in group II, respectively. The functional results were excellent, good, fair, poor and failure in 16, 17, 1, 0 and 1 in group I; and 22, 10, 0, 3 and 0 in group II, respectively. Both fixator systems achieved comparable rates of union and functional outcomes. The rate of deep pintract infection was significantly higher in the rail fixator group but patients found it more comfortable. Conclusion. We recommend the use of a ring fixator in patients with a bone gap of more than 6 cm. Patients with a bone gap up to 6 cm can be managed with either a ring or rail fixator. Cite this article: Bone Joint J 2016;98B:1399–1405


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 868 - 875
1 Aug 2004
Okcu G Aktuglu K

We retrospectively reviewed 60 fractures of the tibial plafond treated by either an ankle-sparing diaphyseal-epiphyseal technique using the Ilizarov ring fixator or by an ankle-spanning technique using a monolateral articulated external fixator. The Ilizarov ring fixator was applied in 24 fractures and the monolateral articulated transarticular external fixator in 20. Both techniques were combined with limited open reduction and internal fixation of the articular surface if necessary. Between three and nine years after the injury, all patients returned for clinical and radiological assessment and evaluation of ankle function using the modified Mazur score. There were no significant differences between the two groups in terms of age, gender, mechanism of injury, type of fracture or length of follow-up. The mean functional ankle score was 86 points for the Ilizarov group and 82 points for the articulated fixator group. The difference was not significant (p = 0.07). There were no significant differences between the groups with regard to the radiographic score and late complications. Patients treated with the Ilizarov ring fixator had significantly better ankle and subtalar movement. We conclude that both techniques of external fixation are satisfactory methods of treatment for fractures of the tibial plafond, but that the total arc of movement of the joint is preserved better without bridging the ankle


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 534 - 541
1 Apr 2016
Tsang STJ Mills LA Frantzias J Baren JP Keating JF Simpson AHRW

Aims. The aim of this study was to identify risk factors for the failure of exchange nailing in nonunion of tibial diaphyseal fractures. . Patients and Methods. A cohort of 102 tibial diaphyseal nonunions in 101 patients with a mean age of 36.9 years (15 to 74) were treated between January 1992 and December 2012 by exchange nailing. Of which 33 (32%) were initially open injuries. The median time from primary fixation to exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to 9.8 months). . The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union. . Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union. . Results. Multiple causes for the primary nonunion were found for 28 (27%) tibiae, with infection present in 32 (31%). Six patients were lost to follow-up. Further surgical procedures were required in 35 (36%) nonunions. Other fixation modalities were required in five fractures. A single nail exchange procedure achieved union in 60/96 (63%) of all nonunions. Only 11 out of 31 infected nonunions (35.4%) healed after one exchange nail procedure. Up to five repeated exchange nailings, with or without bone grafting, ultimately achieved union in 89 (93%) fractures. The median time to union after exchange nailing was 8.7 months (IQR 5.7 to 14.0 months). Univariate analysis confirmed that an oligotrophic/atrophic pattern of nonunion (p = 0.002), a bone gap of 5 mm or more (p = 0.04) and infection (p < 0.001), were predictive for failure of exchange nailing Multiple regression analysis found that infection was the strongest predictor of failure (p < 0.001). . Conclusion. Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. However, in the presence of severe infection with a highly resistant organism, or extensive sclerosis of the bone, other fixation modalities, such as Ilizarov treatment, should be considered. Take home message: Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. Cite this article: Bone Joint J 2016;98-B:534–41


Bone & Joint Open
Vol. 4, Issue 7 | Pages 516 - 522
10 Jul 2023
Mereddy P Nallamilli SR Gowda VP Kasha S Godey SK Nallamilli RR GPRK R Meda VGR

Aims

Musculoskeletal infection is a devastating complication in both trauma and elective orthopaedic surgeries that can result in significant morbidity. Aim of this study was to assess the effectiveness and complications of local antibiotic impregnated dissolvable synthetic calcium sulphate beads (Stimulan Rapid Cure) in the hands of different surgeons from multiple centres in surgically managed bone and joint infections.

Methods

Between January 2019 and December 2022, 106 patients with bone and joint infections were treated by five surgeons in five hospitals. Surgical debridement and calcium sulphate bead insertion was performed for local elution of antibiotics in high concentration. In all, 100 patients were available for follow-up at regular intervals. Choice of antibiotic was tailor made for each patient in consultation with microbiologist based on the organism grown on culture and the sensitivity. In majority of our cases, we used a combination of vancomycin and culture sensitive heat stable antibiotic after a thorough debridement of the site. Primary wound closure was achieved in 99 patients and a split skin graft closure was done in one patient. Mean follow-up was 20 months (12 to 30).


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 977 - 983
1 Sep 2000
Patel VR Menon DK Pool RD Simonis RB

We used the Ilizarov circular external fixator to treat 16 patients with persistent nonunion of the diaphysis of the humerus despite surgical treatment. All patients had pain and severe functional impairment of the affected arm. In ten, nonunion followed intramedullary nailing. We successfully treated these by a closed technique. The nail was left in place and the fracture compressed over it. The fractures of the other six patients had previously been fixed by various methods. We explored these nonunions, removed the fixation devices and excised fibrous tissue and dead bone before stabilising with the Ilizarov fixator. In five patients union was achieved. Bone grafting was not required. In the single patient in whom treatment failed, there had been a severely comminuted open fracture. All except one patient had reduction of pain, and all reported an improvement in function


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 668 - 671
1 Jul 2001
Simpson AHRW Andrews C Giele H

Z-plasty is used to lengthen scars and wounds. We describe the use of a modified technique to shorten wounds in ten consecutive patients undergoing acute shortening of a limb as part of an Ilizarov procedure. The modified technique gave good exposure, easy closure of the wound and fewer problems with healing than standard incisions


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 199 - 203
1 Mar 2001
Dennison MG Pool RD Simonis RB Singh BS

Between 1994 and 1999, we treated six patients with avascular necrosis of the talus by excision of the necrotic body of the talus and tibiocalcaneal fusion using an Ilizarov frame. This was combined with corticotomy and a lengthening procedure. Shortening was corrected in all patients except two, who were over 60 years of age. All patients had previous operations which had failed. All achieved solid bony fusion, with five out of six having either a good or an excellent result. We conclude that this is an effective reconstructive technique which gives a good functional result


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1416 - 1422
1 Nov 2019
Rohilla R Sharma PK Wadhwani J Rohilla S Beniwal R Singh R Devgan A

Aims

In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia.

Patients and Methods

Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study.