To date, all surgical techniques used for reconstruction
of the pelvic ring following supra-acetabular tumour resection produce
high complication rates. We evaluated the clinical, oncological
and functional outcomes of a cohort of 35 patients (15 men and 20
women), including 21 Ewing’s sarcomas, six chondrosarcomas, three sarcomas
not otherwise specified, one osteosarcoma, two osseous malignant
fibrous histiocytomas, one synovial cell sarcoma and one metastasis.
The mean age of the patients was 31 years (8 to 79) and the latest
follow-up was carried out at a mean of 46 months (1.9 to 139.5)
post-operatively. We undertook a functional reconstruction of the pelvic ring using
polyaxial screws and titanium rods. In 31 patients (89%) the construct
was encased in antibiotic-impregnated polymethylmethacrylate. Preservation
of the extremities was possible for all patients. The survival rate
at three years was 93.9% (95% confidence interval (CI) 77.9 to 98.4),
at five years it was 82.4% (95% CI 57.6 to 93.4). For the 21 patients
with Ewing’s sarcoma it was 95.2% (95% CI 70.7 to 99.3) and 81.5%
(95% CI 52.0 to 93.8), respectively. Wound healing problems were
observed in eight patients, deep infection in five and clinically
asymptomatic breakage of the screws in six. The five-year implant survival
was 93.3% (95% CI 57.8 to 95.7). Patients were mobilised at a mean
of 3.5 weeks (1 to 7) post-operatively. A post-operative neurological
defect occurred in 12 patients. The mean Musculoskeletal Tumor Society
score at last available follow-up was 21.2 (10 to 27). This reconstruction technique is characterised by simple and
oncologically appropriate applicability, achieving high primary
stability that allows
The aims of this retrospective study were to report the feasibility
of using 3D-printing technology for patients with a pelvic tumour
who underwent reconstruction. A total of 35 patients underwent resection of a pelvic tumour
and reconstruction using 3D-printed endoprostheses between September
2013 and December 2015. According to Enneking’s classification of
bone defects, there were three Type I lesions, 12 Type II+III lesions,
five Type I+II lesions, two Type I+II+III lesions, ten type I+II+IV
lesions and three type I+II+III+IV lesions. A total of three patients
underwent reconstruction using an iliac prosthesis, 12 using a standard
hemipelvic prosthesis and 20 using a screw-rod connected hemipelvic
prosthesis.Aims
Patients and Methods
Custom-made intercalary endoprostheses may be used for the reconstruction of diaphyseal defects following the resection of bone tumours. The aim of this study was to determine the survival of intercalary endoprostheses with a lap joint design, and to evaluate the clinical results, complications and functional outcome. We retrospectively reviewed six consecutive patients, three of whom underwent limb salvage with intercalary endoprostheses of the tibia, two of the femur, and one of the humerus. Their mean age was 42 years (28 to 64). The mean follow-up was 21.6 months (9 to 58). The humeral prosthesis required revision at 14 months owing to aseptic loosening. There were no implant-related failures. Musculoskeletal Tumour Society functional outcome scores indicated that patients achieved 90% of premorbid function. Custom intercalary endoprostheses result in reconstructions comparable with, if not better than, those of allografts. Using this design of implant reduces the incidence of early complications and difficulties experienced with previous versions.
We reviewed 25 patients who had undergone resection of a primary bone sarcoma which extended to within 5 cm of the knee with reconstruction by a combination of a free vascularised fibular graft and a massive allograft bone shell. The distal femur was affected in four patients and the proximal tibia in 21. Their mean age at the time of operation was 19.7 years (5 to 52) and the mean follow-up period 140 months (28 to 213). Three vascularised transfers failed. The mean time to union of the fibula was 5.6 months (3 to 10) and of the allograft 19.6 months (10 to 34). Full weight-bearing was allowed at a mean of 21.4 months (14 to 36). The mean functional score at final follow-up was 27.4 (18 to 30) using a modfied 30-point Musculoskeletal Tumour Society rating system. The overall limb-salvage rate was 88%. The results of our study suggest that the combined use of a vascularised fibular graft and allograft is of value as a limb-salvage procedure for intercalary reconstruction after resection of bone tumours around the knee, especially in skeletally immature patients.