Advertisement for orthosearch.org.uk
Results 1 - 20 of 75
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1225 - 1233
1 Nov 2022
Png ME Petrou S Achten J Ooms A Lamb SE Hedley H Dias J Costa ML

Aims. The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. Methods. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves. Results. In the base case analysis, surgical fixation with K-wire was more expensive (£29.65 (95% confidence interval (CI) -94.85 to 154.15)) and generated lower QALYs (0.007 (95% CI -0.03 to 0.016)) than moulded casting, but this difference was not statistically significant. The probability of K-wire being cost-effective at a £20,000 per QALY cost-effectiveness threshold was 24%. The cost-effectiveness results remained robust in the sensitivity analyses. Conclusion. The findings suggest that surgical fixation with K-wire is unlikely to be a cost-effective alternative to a moulded cast in adults, following manipulation of a fracture of the distal radius in a theatre setting. Cite this article: Bone Joint J 2022;104-B(11):1225–1233


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 993 - 999
1 Sep 2023
van Delft EAK van Bruggen SGJ van Stralen KJ Bloemers FW Sosef NL Schep NWL Vermeulen J

Aims. There is no level I evidence dealing with the optimal period of immobilization for patients with a displaced distal radial fracture following closed reduction. A shorter period might lead to a better functional outcome due to less stiffness and pain. The aim of this study was to investigate whether this period could be safely reduced from six to four weeks. Methods. This multicentre randomized controlled trial (RCT) included adult patients with a displaced distal radial fracture, who were randomized to be treated with immobilization in a cast for four or six weeks following closed reduction. The primary outcome measure was the Patient-Rated Wrist Evaluation (PRWE) score after follow-up at one year. Secondary outcomes were the abbreviated version of the Disability of Arm, Shoulder and Hand (QuickDASH) score after one year, the functional outcome at six weeks, 12 weeks, and six months, range of motion (ROM), the level of pain after removal of the cast, and complications. Results. A total of 100 patients (15 male, 85 female) were randomized, with 49 being treated with four weeks of immobilization in a cast. A total of 93 completed follow-up. The mean PRWE score after one year was 6.9 (SD 8.3) in the four-week group compared with 11.6 (SD 14.3) in the six-week group. However, this difference of -4.7 (95% confidence interval -9.29 to 0.14) was not clinically relevant as the minimal clinically important difference of 11.5 was not reached. There was no significant difference in the ROM, radiological outcome, level of pain, or complications. Conclusion. In adult patients with a displaced and adequately reduced distal radial fracture, immobilization in a cast for four weeks is safe, and the results are similar to those after a period of immobilization of six weeks. Cite this article: Bone Joint J 2023;105-B(9):993–999


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1542 - 1548
2 Nov 2020
Stirling PHC Oliver WM Ling Tan H Brown IDM Oliver CW McQueen MM Molyneux SG Duckworth AD

Aims. The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius. Methods. We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score. Results. Long-term outcomes were available for 89 patients (72%). The mean age was 57 years (SD 15) and 68 were female (76%). The median time from injury to corrective osteotomy was nine months (interquartile range (IQR) 6 to 13). At a mean follow-up of six years (1 to 11) the median PRWE score was 22 (IQR 7 to 40), the median QuickDASH score was 11.4 (IQR 2.3 to 31.8), and the median EQ-5D-5L score was 0.84 (IQR 0.69 to 1). The NPS was 69. Multivariate regression analysis showed that the presence of an associated ulnar styloid fracture was the only significant independent factor associated with a worse PRWE score when adjusting for confounding variables (p = 0.004). Conclusion. We found that corrective osteotomy for malunion of the distal radius can result in good functional outcomes and high levels of patient satisfaction. However, the presence of an ulnar styloid fracture may adversely affect function. Level of Evidence: III (cohort study). Cite this article: Bone Joint J 2020;102-B(11):1542–1548


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1257 - 1262
1 Nov 2024
Nowak LL Moktar J Henry P Dejong T McKee MD Schemitsch EH

Aims. We aimed to compare reoperations following distal radial fractures (DRFs) managed with early fixation versus delayed fixation following initial closed reduction (CR). Methods. We used administrative databases in Ontario, Canada, to identify DRF patients aged 18 years or older from 2003 to 2016. We used procedural and fee codes within 30 days to determine which patients underwent early fixation (≤ seven days) or delayed fixation following CR. We grouped patients in the delayed group by their time to definitive fixation (eight to 14 days, 15 to 21 days, and 22 to 30 days). We used intervention and diagnostic codes to identify reoperations within two years. We used multivariable regression to compare the association between early versus delayed fixation and reoperation for all patients and stratified by age (18 to 60 years and > 60 years). Results. We identified 14,960 DRF patients, 8,339 (55.7%) of whom underwent early surgical fixation (mean 2.9 days (SD 1.8)). In contrast, 4,042 patients (27.0%) underwent delayed fixation between eight and 14 days (mean 10.2 days (SD 2.2)), 1,892 (12.7%) between 14 and 21 days (mean 17.5 days (SD 1.9)) and 687 (4.6%) > 21 days (mean 24.8 days (SD 2.4)) post-fracture. Patients who underwent delayed fixation > 21 days post-fracture had a higher odds of reoperation (odds ratio (OR) 1.33 (95% CI 1.11 to 1.79) vs early fixation). This worsened for patients aged > 60 years (OR 1.69 (95% CI 1.11 to 2.79)). We found no difference in the odds of reoperation for patients who underwent delayed fixation within eight to 14 or 15 to 21 days post-fracture (vs early fixation). Conclusion. These data suggest that DRF patients with fractures with unacceptable reduction following CR should be managed within three weeks to avoid detrimental outcomes. Prospective studies are required to confirm these findings. Cite this article: Bone Joint J 2024;106-B(11):1257–1262


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 137 - 143
1 Jan 2020
Dias R Johnson NA Dias JJ

Aims. Carpal malalignment after a distal radial fracture occurs due to loss of volar tilt. Several studies have shown that this has an adverse influence on function. We aimed to investigate the magnitude of dorsal tilt that leads to carpal malalignment, whether reduction of dorsal tilt will correct carpal malalignment, and which measure of carpal malalignment is the most useful. Methods. Radiographs of patients with a distal radial fracture were prospectively collected and reviewed. Measurements of carpal malalignment were recorded on the initial radiograph, the radiograph following reduction of the fracture, and after a further interval. Linear regression modelling was used to assess the relationship between dorsal tilt and carpal malalignment. Receiver operating characteristic (ROC) analysis was used to identify which values of dorsal tilt led to carpal malalignment. Results. A total of 250 consecutive patients with 252 distal radial fractures were identified. All measures of carpal alignment were significantly associated with dorsal tilt at each timepoint. This relationship persisted after adjustment for age, sex, and the position of the wrist. Capitate shift consistently had the strongest relationship with dorsal tilt and was the only parameter that was not influenced by age or the position of the wrist. ROC curve analysis identified that abnormal capitate shift was seen with > 9° of dorsal tilt. Conclusion. Carpal malalignment is related to dorsal tilt following a distal radial fracture. Reducing the fracture and improving dorsal tilt will reduce carpal malalignment. Capitate shift is easy to assess visually, unrelated to age and sex, and appears to be the most useful measure of carpal malalignment. The aim during reduction of a distal radial fracture should be to realign the capitate with the axis of the radius and prevent carpal malalignment. Cite this article: Bone Joint J 2020;102-B(1):137–143


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims. The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. Methods. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard. Results. In order to detect dorsal screw penetration, the sensitivity of dorsal tangential views was 39% with a negative predictive value (NPV) of 91% and an accuracy of 91%; compared with a sensitivity of 25% for 3D fluoroscopy with a NPV of 93% and an accuracy of 93%. On the postoperative CT scans, we found penetrating screws in: 1) 40% of patients in the 2D fluoroscopy group; 2) in 32% of those in the 2D fluoroscopy group with AP, lateral, and dorsal tangential views; and 3) in 25% of patients in the 3D fluoroscopy group. In all three groups, the second compartment was prone to penetration, while the postoperative incidence decreased when more advanced imaging was used. There were no penetrating screws in the third compartment (extensor pollicis longus groove) in the 3D fluoroscopy groups, and one in the dorsal tangential views group. Conclusion. Advanced intraoperative imaging helps to identify screws which have penetrated the dorsal compartments of the wrist. However, based on diagnostic performance characteristics, one cannot conclude that 3D fluoroscopy outperforms dorsal tangential views when used for this purpose. Dorsal tangential views are sufficiently accurate to detect dorsal screw penetration, and arguably more efficacious than 3D fluoroscopy. Cite this article: Bone Joint J 2020;102-B(7):874–880


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1498 - 1505
1 Dec 2019
Sonntag J Woythal L Rasmussen P Branner U Hølmer P Jensen AK Lange KHW Brorson S

Aims. The aim of this study was to investigate the difference in functional outcome after repair and non-repair of the pronator quadratus muscle in patients undergoing surgical treatment for a distal radial fracture with volar plating. Patients and Methods. A total of 72 patients with a distal radial fracture were included in this randomized clinical trial. They were allocated to have the pronator quadratus muscle repaired or not, after volar locked plating of a distal radial fracture. The patients, the assessor, the primary investigator, and the statistician were blinded to the allocation. Randomization was irreversibly performed using a web application that guaranteed a secure and tamper-free assignment. The primary outcome measure was the Patient Rated Wrist Evaluation (PRWE) after 12 months. Secondary outcomes included the Disabilities of the Arm, Shoulder and Hand (DASH) score, pronation strength, grip strength, the range of pronation and supination, complications, and the operating time. Results. Of the 72 patients, 63 (87.5%) completed follow-up for the primary outcome measure: 31 (86.1%) from the non-repair group and 32 (88.9%) from the repair group. At the 12-month follow-up, the mean difference in PRWE of 5.47 (95% confidence interval (CI) -4.02 to 14.96) between the repair (mean 18.38 (95% CI 10.34 to 26.41)) and non-repair group (mean 12.90 (95% CI 7.55 to 18.25)) was not statistically significant (p = 0.253). There was a statistically significant difference between pronation strength, favouring non-repair. We found no difference in the other secondary outcomes. Conclusion. We found that repairing pronator quadratus made no difference to the clinical outcome, 12 months after volar plating of a distal radial fracture. We conclude that there is no functional advantage in repairing this muscle under these circumstances and advise against it. Cite this article: Bone Joint J 2019;101-B:1498–1505


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 376 - 382
1 Mar 2017
Plant CE Parsons NR Costa ML

Aims. We conducted a study to determine whether radiological parameters correlate with patient reported functional outcome, health-related quality of life and physical measures of function in patients with a fracture of the distal radius. Patients and Methods. The post-operative palmar tilt and ulnar variance at six weeks and 12 months were correlated with the Patient Rated Wrist Evaluation, Disabilities of the Arm, Shoulder and Hand, and EuroQol scores, grip strength, pinch strength and range of movement at three, six and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical fixation, with either percutaneous pinning or reconstruction with a volar plate, for a fracture of the distal radius. Results. Radiological parameters were found to correlate poorly with the patient reported outcomes (r = 0.00 to 0.47) and physical measures of function (r = 0.01 to 0.51) at all intervals. Conclusion. This study raises concerns about the use of radiological parameters to determine management, and to act as a surrogates for successful treatment, in patients with a fracture of the distal radius. Restoration of ‘normal’ radiographic parameters may not be necessary to achieve a satisfactory functional outcome for the patient. Cite this article: Bone Joint J 2017;99-B:376–82


Aims. The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a volar locking plate for a distal radial fracture. Methods. This study was a retrospective review of a prospective database of 155 patients who underwent internal fixation with a volar locking plate for a distal radial fracture between August 2014 and April 2017. Data which were collected included postoperative PROMs (Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH) and Patient-Rated Wrist Evaluation (PRWE)), and SANE scores at one month (n = 153), two months (n = 155), three months (n = 144), six months (n = 128), and one year (n = 73) after operation. Patients with incomplete data were excluded from this study. Correlation and agreement between PROMs and SANE scores were evaluated. Subgroup analyses were carried out to identify correlations according to variables such as age, the length of follow-up, and subcategories of the PRWE score. Results. The Pearson correlation coefficient (r) between PROMs and SANE scores was -0.76 (p < 0.001) for DASH and -0.72 (p < 0.001) for PRWE, respectively. Limits of agreement between PROMs and ‘100-SANE’ scores were met for at least 93% of the data points. In subgroup analysis, there were significant negative correlations between PROMs and SANE scores for all age groups and for follow-up of more than six months. The correlation coefficient between PRWE subcategories and SANE score was -0.67 (p < 0.001) for PRWE pain score and -0.69 (p < 0.001) for PRWE function score, respectively. Conclusion. We found a significant correlation between postoperative SANE and PROMs in patients treated with a volar locking plate for a distal radial fracture. The SANE score is thus a reliable indicator of outcome for patients who undergo surgical treatment for a radial fracture. Cite this article: Bone Joint J 2020;102-B(6):744–748


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 205 - 211
1 Feb 2018
Pang EQ Truntzer J Baker L Harris AHS Gardner MJ Kamal RN

Aims. The aim of this study was to test the null hypothesis that there is no difference, from the payer perspective, in the cost of treatment of a distal radial fracture in an elderly patient, aged > 65 years, between open reduction and internal fixation (ORIF) and closed reduction (CR). Materials and Methods. Data relating to the treatment of these injuries in the elderly between January 2007 and December 2015 were extracted using the Humana and Medicare Advantage Databases. The primary outcome of interest was the cost associated with treatment. Secondary analysis included the cost of common complications. Statistical analysis was performed using a non-parametric t-test and chi-squared test. Results. Our search yielded 8924 patients treated with ORIF and 5629 patients treated with CR. The mean cost of an uncomplicated ORIF was more than a CR ($7749 versus $2161). The mean additional cost of a complication in the ORIF group was greater than in the CR group ($1853 versus $1362). Conclusion. These findings show that there are greater payer fees associated with ORIF than CR in patients aged > 65 years with a distal radial fracture. CR may be a higher-value intervention in these patients. Cite this article: Bone Joint J 2018;100-B:205–11


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1069 - 1073
1 Aug 2016
Stirling E Jeffery J Johnson N Dias J

Aims. The degree of displacement of a fracture of the distal radius is an important factor which can be assessed using simple radiographic measurements. Our aim was to investigate the reliability and reproducibility of these measurements and to determine if they should be used clinically. Patients and Methods. A 10% sample was randomly generated from 3670 consecutive adult patients who had presented to University Hospitals of Leicester NHS Trust between 2007 and 2010 with a fracture of the distal radius. Radiographs of the 367 patients were assessed by two independent reviewers. Four measurements of displacement of the fracture were recorded and the inter-observer correlation assessed using the intra-class correlation coefficient. Results. Inter-observer correlation was high (> 0.8) for three of the four measurements. Repeat measurements of a further randomly generated 10% sample (37) were made four weeks later to assess intra-observer agreement, which was again high (> 0.8) for the same three parameters (radial height, radial inclination and dorsal/palmar tilt). Correlation was poor for articular step and gap. Conclusion. Radiographic assessment of radial angle, radial inclination and dorsal/palmar tilt is a reliable method of determining the degree of displacement of a fracture of the distal radius. Cite this article: Bone Joint J 2016;98-B:1069–73


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 749 - 754
1 Jun 2020
Jung H Park MJ Won Y Lee GY Kim S Lee JS

Aims. The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear. Methods. Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables. Results. Univariate analysis showed that the flat-face type was more prevalent in the patients than in the control group (43% vs 21%; p = 0.002), while the C-type was lower in the patients than in the control group (3% vs 17%; p = 0.011). The depth and version angle of sigmoid notch showed a negative association with the TFCC foveal tear in the multivariate analysis (depth: odds ratio (OR) 0.380; p = 0.037; version angle: OR 0.896; p = 0.033). Estimated cut-off values were 1.34 mm for the depth (area under the curve (AUC) = 0.725) and 10.45° for the version angle (AUC = 0.726). Conclusion. The proportion of flat-face sigmoid notch type was greater in the patient group than in the control group. The depth and version angle of sigmoid notch were negatively associated with TFCC foveal injury. Cite this article: Bone Joint J 2020;102-B(6):749–754


Aims. The aim of this study was to compare the clinical effectiveness of Kirschner wire (K-wire) fixation with locking-plate fixation for patients with a dorsally displaced fracture of the distal radius in the five years after injury. Patients and Methods. We report the five-year follow-up of a multicentre, two-arm, parallel-group randomized controlled trial. A total of 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation were recruited from 18 trauma centres in the United Kingdom. Patients were excluded if the surface of the wrist joint was so badly displaced it required open reduction. In all, 448 patients were randomized to receive either K-wire fixation or locking-plate fixation. In the K-wire group, there were 179 female and 38 male patients with a mean age of 59.1 years (19 to 89). In the locking-plate group, there were 194 female and 37 male patients with a mean age of 58.3 years (20 to 89). The primary outcome measure was the patient-rated wrist evaluation (PRWE). Secondary outcomes were health-related quality of life using the EuroQol five-dimension three-level (EQ-5D-3L) assessment, and further surgery related to the index fracture. Results. At 12 months, 402/448 participants (90%) recruited into the main study provided PRWE scores. At year two, 294 participants (66%) provided scores; at year five, 198 participants (44%) provided scores. There was no clinically relevant difference in the PRWE at any point during the five-year follow-up; at five years, the PRWE score was 8.3 (12.5) in the wire group and 11.3 (15.6) in the plate group (95% confidence interval -6.99 to 0.99; p = 0.139). Nor was there a clinically relevant difference in health-related quality of life. Only three participants had further surgery in the five years after their injury (one in the wire group and two in the plate group). Conclusion. This follow-up study continues to show no evidence of a difference in wrist pain, wrist function, or quality of life for patients treated with wires versus locking plates in the five years following a dorsally displaced fracture of the distal radius. Cite this article: Bone Joint J 2019;101-B:978–983


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1370 - 1376
1 Oct 2015
Jordan RW Saithna A

This article is a systematic review of the published literature about the biomechanics, functional outcome and complications of intramedullary nailing of fractures of the distal radius. We searched the Medline and EMBASE databases and included all studies which reported the outcome of intramedullary (IM) nailing of fractures of the distal radius. Data about functional outcome, range of movement (ROM), strength and complications, were extracted. The studies included were appraised independently by both authors using a validated quality assessment scale for non-controlled studies and the CONSORT statement for randomised controlled trials (RCTs). The search strategy revealed 785 studies, of which 16 were included for full paper review. These included three biomechanical studies, eight case series and five randomised controlled trials (RCTs). . The biomechanical studies concluded that IM nails were at least as strong as locking plates. The clinical studies reported that IM nailing gave a comparable ROM, functional outcome and grip strength to other fixation techniques. . However, the mean complication rate of intramedullary nailing was 17.6% (0% to 50%). This is higher than the rates reported in contemporary studies for volar plating. It raises concerns about the role of intramedullary nailing, particularly when comparative studies have failed to show that it has any major advantage over other techniques. Further adequately powered RCTs comparing the technique to both volar plating and percutaneous wire fixation are needed. Cite this article: Bone Joint J 2015;97-B:1370–6


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 369 - 375
1 Mar 2017
Ross M Wiemann M Peters SE Benson R Couzens GB

Aims. The aims of this study were: firstly, to investigate the influence of the thickness of cartilage at the sigmoid notch on the inclination of the distal radioulnar joint (DRUJ), and secondly, to compare the sensitivity and specificity of MRI with plain radiographs for the assessment of the inclination of the articular surface of the DRUJ in the coronal plane. . Patients and Methods. Contemporaneous MRI images and radiographs of 100 wrists from 98 asymptomatic patients (mean age 43 years, (16 to 67); 52 male, 53%) with no history of a fracture involving the wrist or surgery to the wrist, were reviewed. The thickness of the cartilage at the sigmoid notch, inclination of the DRUJ and Tolat Type of each DRUJ were determined. . Results. The assessment using MRI scans and cortical bone correlated well with radiographs, with a kappa value of 0.83. The mean difference between the inclination using the cortex and cartilage on MRI scans was 12°, leading to a change of Tolat type of inclination in 66% of wrists. No reverse oblique (Type 3) inclinations were found when using the cartilage to assess inclination. . Conclusion . These data revealed that when measuring the inclination of the DRUJ using cartilage, reverse oblique inclinations might not exist. The data suggest that performing an ulna shortening osteotomy might be reasonable even in distal radioulnar joints where the plain radiographic appearance suggests an unfavourable reverse oblique inclination in the coronal plane. We recommend using MRI to validate radiographs in those that appear to be reverse oblique (Tolat Type 3), as the true inclination might be different, thereby removing one possible contraindication to ulnar shortening. Cite this article: Bone Joint J 2017;99-B:369–75


Aims

The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury.

Methods

Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1514 - 1520
1 Nov 2013
D’Agostino P Barbier O

The osteoinductive properties of demineralised bone matrix have been demonstrated in animal studies. However, its therapeutic efficacy has yet to be proven in humans. The clinical properties of AlloMatrix, an injectable calcium-based demineralised bone matrix allograft, were studied in a prospective randomised study of 50 patients with an isolated unstable distal radial fracture treated by reduction and Kirschner (K-) wire fixation. A total of 24 patients were randomised to the graft group (13 men and 11 women, mean age 42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18 women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively, patients underwent radiological evaluation, assessments for range of movement, grip and pinch strength, and also completed the Disabilities of Arm, Shoulder and Hand questionnaire. At one and six weeks and one year post-operatively, bone mineral density evaluations of both wrists were performed. No significant difference in wrist function and speed of recovery, rate of union, complications or bone mineral density was found between the two groups. The operating time was significantly higher in the graft group (p = 0.004). Radiologically, the reduction parameters remained similar in the two groups and all AlloMatrix extraosseous leakages disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate a beneficial effect of AlloMatrix demineralised bone matrix in the treatment of this category of distal radial fractures treated by K-wire fixation. Cite this article: Bone Joint J 2013;95-B:1514–20


We compared the ceiling effects of two patient-rating scores, the Disability of the Arm, Shoulder and Hand (DASH) and Patient-Rated Wrist Evaluation (PRWE), and a physician-rating score, the Modified Mayo Wrist Score (MMWS) in assessing the outcome of surgical treatment of an unstable distal radial fracture. A total of 77 women with a mean age of 64.2 years (50 to 88) who underwent fixation using a volar locking plate for an unstable distal radial fracture between 2011 and 2013 were enrolled in this study. All completed the DASH and PRWE questionnaires one year post-operatively and were assessed using the MMWS by the senior author. The ceiling effects in the outcome data assessed for each score were estimated. The data assessed with both patient-rating scores, the DASH and PRWE, showed substantial ceiling effects, whereas the data assessed with MMWS showed no ceiling effect. Researchers should be aware of a possible ceiling effect in the assessment of the outcome of the surgical treatment of distal radial fractures using patient-rating scores. It could also increase the likelihood of a type II error. Cite this article: Bone Joint J 2015;97-B:1651–6


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 818 - 823
1 Jun 2015
Plant CE Hickson C Hedley H Parsons NR Costa ML

We conducted an observational radiographic study to determine the inter- and intra-observer reliability of the AO classification of fractures of the distal radius. Plain posteroanterior and lateral radiographs of 456 patients with an acute fracture of the distal radius were classified by a consultant orthopaedic hand specialist and two specialist trainees, and the k coefficient for the inter- and intra-observer reliability of the type, group and subgroup classification was calculated. . Only the type of fracture (A, B or C) was found to provide substantial intra-observer reliability (k . type. 0.65). The inclusion of ‘group’ and ‘subgroup’ into the classification reduced the inter-observer reliability to fair (k. group. 0.29, k. subgroup . = 0.28) and the intra-observer reliability to moderate (k. group. 0.53, k. subgroup. 0.49). Disagreement was found to arise between specific subgroups, which may be amenable to clarification. Cite this article: Bone Joint J 2015; 97-B:818–23


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 508 - 512
1 Apr 2014
van Amerongen EA Creemers LB Kaoui N Bekkers JEJ Kon M Schuurman AH

Damage to the cartilage of the distal radioulnar joint frequently leads to pain and limitation of movement, therefore repair of this joint cartilage would be highly desirable. The purpose of this study was to investigate the fixation of scaffold in cartilage defects of this joint as part of matrix-assisted regenerative autologous cartilage techniques. Two techniques of fixation of collagen scaffolds, one involving fibrin glue alone and one with fibrin glue and sutures, were compared in artificially created cartilage defects of the distal radioulnar joint in a human cadaver. After being subjected to continuous passive rotation, the methods of fixation were evaluated for cover of the defect and pull out force. No statistically significant differences were found between the two techniques for either cover of the defect or integrity of the scaffold. However, a significantly increased mean pull out force was found for the combined procedure, 0.665 N (0.150 to 1.160) versus 0.242 N (0.060 to 0.730) for glue fixation (p = 0.001). This suggests that although successful fixation of a collagen type I/III scaffold in a distal radioulnar joint cartilage defect is feasible with both forms of fixation, fixation with glue and sutures is preferable. Cite this article: Bone Joint J 2014;96-B:508–12