Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 555 - 561
1 Apr 2014
Igarashi K Yamamoto N Shirai T Hayashi K Nishida H Kimura H Takeuchi A Tsuchiya H

In 1999, we developed a technique for biological reconstruction after excision of a bone tumour, which involved using autografts of the bone containing the tumour treated with liquid nitrogen. We have previously reported the use of this technique in 28 patients at a mean follow up of 27 months (10 to 54).

In this study, we included 72 patients who underwent reconstruction using this technique. A total of 33 patients died and three were lost to follow-up, at a mean of 23 months (2 to 56) post-operatively, leaving 36 patients available for a assessment at a mean of 101 months 16 to 163) post-operatively. The methods of reconstruction included an osteo-articular graft in 16, an intercalary in 13 and, a composite graft with prosthesis in seven.

Post-operative function was excellent in 26 patients (72.2%), good in seven (19.4%), and fair in three (8.3%) according to the functional evaluation system of Enneking. No recurrent tumour occurred within the grafts. The autografts survived in 29 patients (80.6%), and the rates of survival at five and ten years were 86.1% and 80.6 %, respectively. Seven of 16 osteo-articular grafts (44%) failed because of fracture or infection, but all the composite and intercalary grafts survived.

The long-term outcomes of frozen autografting, particularly using composite and intercalary grafts, are satisfactory and thus represent a good method of treatment for patients with a sarcoma of bone or soft tissue.

Cite this article: Bone Joint J 2014;96-B:555–61.


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 2 | Pages 402 - 417
1 May 1973
Salama R Burwell RG Dickson IR

1. This paper reports a histological study of the fate of sheep and calf cancellous bone grafts impregnated with autologous red marrow of Wistar rats and implanted intramuscularly as composite xenograft-autografts for two to twelve weeks. It also includes some biochemical estimations of certain types of sheep and calf bone used to prepare these composite grafts. 2. Only one of 223 devitalised bone xenografts implanted without autologous marrow formed new bone; in contrast 216 of 223 transplanted with marrow formed new bone. 3. The new bone formed by the composite grafts is derived from the autologous marrow. There was no evidence for an inductive effect upon the marrow of the various types of xenograft bone studied as described previously for allograft bone (Burwell 1966). 4. The highest score of new bone formation was found in composite grafts based on fully deproteinised sheep iliac bone prepared at Oswestry. Statistically this score was significantly higher than those registered by composite grafts prepared from intact (frozen and freeze-dried), decalcified (frozen and freeze-dried) and Kiel sheep bone, and by Kiel and Oswestry calf bone (Table II). 5. The histological evidence reported suggests that the high score with the sheep Oswestry composite grafts is because Oswestry bone is feebly immunogenic, if at all; and that such feeble or absent immunogenicity permits more marrow cells to differentiate into osteoblasts and lay down new bone without impediment. 6. The lower scores of new bone formation in most of the undeproteinised composite grafts of sheep origin–intact frozen, intact freeze-dried and Kiel–are attributed to residual immunogenicity within the organic material of the donor bone, because each type evoked the formation of mature plasma cells. 7. The Kiel bone grafts appeared to evoke less of a plasma cell reaction and may be less immunogenic than the intact and decalcified bone xenografts. 8. The sheep Oswestry CXA's formed significantly more new bone than did the calf Oswestry CXA's. This difference may be due to the different physical properties of the bone obtained from old sheep compared with the bone obtained from a young calf


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 3 | Pages 532 - 566
1 Aug 1966
Burwell RG

1. The present study is an attempt to analyse and apportion significance to the role of inductive mechanisms in bone transplantation. 2. The experimental model used in the present work is that of the composite homograftautograft of cancellous bone previously described (Burwell 1964a). 3. Iliac bone was removed from hooded rats and washed free from its marrow. The bone was then treated by various physical and chemical methods (some of which have been used by other workers to prepare bank bone), namely freezing (-20 degrees Centigrade, -79 degrees Centigrade, -196 degrees Centigrade); freeze-drying (without sterilisation, sterilisation with high energy radiation, sterilisation with ß-propiolactone); decalcification (with E.D.T.A.); irradiation (in the frozen state at a dose of 4 million rads); boiling in water; immersion in merthiolate solution; extraction of organic components with ethylenediamine: and calcining at 660 degrees Centigrade. The treated bone was then impregnated with fresh autologous marrow procured from the femoral shaft of the Wistar rat into which the treated composite graft was to be implanted. The grafts were inserted intramuscularly and removed for study after two, six and twelve weeks. 4. After fixation, serial sectioning and staining, each graft was examined microscopically, and the proportion of new bone/grafted bone scored using an arbitrary scale (0-4). The mean score (and the standard error of the mean score) was then plotted for each treated composite graft and also for several types of fresh cancellous bone grafts. 5. It was found (Fig. 2) that the various treated composite grafts formed a spectrum of bone-forming capacities–the maximum scores being attained by the frozen and freeze-dried composite grafts, the lowest scores by the "deproteinised" composite grafts. 6. The reasons for these differences are discussed. It is concluded that cancellous bone, after transplantation, has the property to induce and promote osteogenesis in marrow; moreover, that this property is contained in the organic components of bone. 7. From the standpoint of inductive mechanisms, cancellous bone treated by freezing or freeze-drying seems to be the most suitable devitalised bone for grafting purposes; bone which has been boiled or merthiolated less suitable; and "deproteinised" bone the least suitable. 8. Freeze-dried bone sterilised physically (by high energy radiation) or chemically (by ß-propiolactone) did not form significantly less new bone than did freeze-dried bone which had not been sterilised. 9. Remodelling mechanisms in bone transplantation are briefly discussed and attention drawn to the deficiencies of present knowledge. The quantitative studies of other workers have indicated that freeze-dried bone may be more rapidly remodelled than is frozen bone. 10. The importance of fresh red marrow in promoting osteogenesis in bone transplantation and in the healing of certain fractures, is emphasised. It seems likely that the interrelationship of bone and marrow revealed by experiment has wider significance not only in health and in response to injury but also in causation of certain idiopathic bone disorders


Bone & Joint 360
Vol. 13, Issue 2 | Pages 8 - 12
1 Apr 2024
Craxford S


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 751 - 759
1 Jul 2023
Lu V Andronic O Zhang JZ Khanduja V

Aims

Hip arthroscopy (HA) has become the treatment of choice for femoroacetabular impingement (FAI). However, less favourable outcomes following arthroscopic surgery are expected in patients with severe chondral lesions. The aim of this study was to assess the outcomes of HA in patients with FAI and associated chondral lesions, classified according to the Outerbridge system.

Methods

A systematic search was performed on four databases. Studies which involved HA as the primary management of FAI and reported on chondral lesions as classified according to the Outerbridge classification were included. The study was registered on PROSPERO. Demographic data, patient-reported outcome measures (PROMs), complications, and rates of conversion to total hip arthroplasty (THA) were collected.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1151 - 1159
1 Sep 2019
Oike N Kawashima H Ogose A Hatano H Ariizumi T Kaidu M Aoyama H Endo N

Aims

We analyzed the long-term outcomes of patients observed over ten years after resection en bloc and reconstruction with extracorporeal irradiated autografts

Patients and Methods

This retrospective study included 27 patients who underwent resection en bloc and reimplantation of an extracorporeal irradiated autograft. The mean patient age and follow-up period were 31.7 years (9 to 59) and 16.6 years (10.3 to 24.3), respectively. The most common diagnosis was osteosarcoma (n = 10), followed by chondrosarcoma (n = 6). The femur (n = 13) was the most frequently involved site, followed by the tibia (n = 7). There were inlay grafts in five patients, intercalary grafts in 15 patients, and osteoarticular grafts in seven patients. Functional outcome was evaluated with the Musculoskeletal Tumor Society (MSTS) scoring system.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1681 - 1688
1 Dec 2017
Jones CW Shatrov J Jagiello JM Millington S Hong A Boyle R Stalley PD

Aims

We present a retrospective review of patients treated with extracorporeally irradiated allografts for primary and secondary bone tumours with the mid- and long-term survivorship and the functional and radiographic outcomes.

Patients and Methods

A total of 113 of 116 (97.4%) patients who were treated with extracorporeally irradiated allografts between 1996 and 2014 were followed up. Forms of treatment included reconstructions, prostheses and composite reconstructions, both with and without vascularised grafts. Survivorship was determined by the Kaplan-Meier method. Clinical outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) scoring system, the Toronto Extremity Salvage Score (TESS) and Quality of Life-C30 (QLQ-30) measures. Radiographic outcomes were assessed using the International Society of Limb Salvage (ISOLS) radiographic scoring system.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 28 - 30
1 Oct 2014

The October 2014 Oncology Roundup360 looks at: how best to reconstruct humeral tumours; not everything is better via the arthroscope; obesity and sarcoma; frozen autograft; en-bloc resection and metastatic disease; positive margins in soft-tissue injuries; lipomatous tumours explored; and what happens with recurrence of osteosarcoma.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 582 - 589
1 May 2015
Brennan SA Ní Fhoghlú C Devitt BM O’Mahony FJ Brabazon D Walsh A

Implant-associated infection is a major source of morbidity in orthopaedic surgery. There has been extensive research into the development of materials that prevent biofilm formation, and hence, reduce the risk of infection. Silver nanoparticle technology is receiving much interest in the field of orthopaedics for its antimicrobial properties, and the results of studies to date are encouraging. Antimicrobial effects have been seen when silver nanoparticles are used in trauma implants, tumour prostheses, bone cement, and also when combined with hydroxyapatite coatings. Although there are promising results with in vitro and in vivo studies, the number of clinical studies remains small. Future studies will be required to explore further the possible side effects associated with silver nanoparticles, to ensure their use in an effective and biocompatible manner. Here we present a review of the current literature relating to the production of nanosilver for medical use, and its orthopaedic applications.

Cite this article: Bone Joint J 2015; 97-B:582–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 706 - 711
1 Jun 2006
Robertson A Nutton RW Keating JF


Bone & Joint 360
Vol. 2, Issue 6 | Pages 22 - 24
1 Dec 2013

The December 2013 Shoulder & Elbow Roundup360 looks at: Platelet-rich plasma; Arthroscopic treatment of sternoclavicular joint osteoarthritis; Synchronous arthrolysis and cuff repair; Arthroscopic arthrolysis; Regional blockade in the beach chair; Recurrent instability; Avoiding iatrogenic nerve injury in elbow arthroscopy; and Complex reconstruction of total elbow revisions


Bone & Joint 360
Vol. 1, Issue 6 | Pages 30 - 32
1 Dec 2012

The December 2012 Research Roundup360 looks at: whether the rheumatoid factor is just a ‘quick test’; osteonecrosis in smokers; pasteurisation effect on bone reconstruction; venous thromboembolism risk in rheumatoids; whether stem cells reverse age-related osteopenia; the effect of running on rat knees; rapid fracture healing in rats with ultrasound; magnetic stem cells; and the safety of surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1431 - 1437
1 Nov 2009
Biring GS Kostamo T Garbuz DS Masri BA Duncan CP

We report the outcome at ten to 15 years of two-stage revision for hip infection in 99 patients using the Prostalac articulated hip spacer system.

All the patients were contacted to determine their current functional and infection status using the Oxford-12, Short form-12, and Western Ontario and McMaster University Osteoarthritis Index questionnaires. A total of 11 of the 99 patients had a further infection, of whom seven responded to repeat surgery with no further sequelae. The mean interval between the stages was five months (1 to 36). We were able to review 48 living patients, with a mean age of 72 years (46 to 86), 34 (71%) of whom provided health-related quality-of-life outcome scores.

The mean follow-up was 12 years (10 to 15). The long-term success rate was 89% and with additional surgery this rose to 96%. The mean global Western Ontario and McMaster University Osteoarthritis Index score was 80.6 (sd 18.3). The mean Oxford-12 score was 74.0 (sd 22.3), and the mean Short form-12 score was 53.1 (sd 9.4) (mental) and 33.5 (sd 13.5) (physical). The mean satisfaction score was 90.5 (sd 15.3).

Two-stage revision for hip infection using a Prostalac interim spacer offers a predictable and lasting solution for patients with this difficult problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 294 - 303
1 Mar 2009
Lindner T Kanakaris NK Marx B Cockbain A Kontakis G Giannoudis PV

Failure of fixation is a common problem in the treatment of osteoporotic fractures around the hip. The reinforcement of bone stock or of fixation of the implant may be a solution. Our study assesses the existing evidence for the use of bone substitutes in the management of these fractures in osteoporotic patients. Relevant publications were retrieved through Medline research and further scrutinised. Of 411 studies identified, 22 met the inclusion criteria, comprising 12 experimental and ten clinical reports. The clinical studies were evaluated with regard to their level of evidence. Only four were prospective and randomised.

Polymethylmethacrylate and calcium-phosphate cements increased the primary stability of the implant-bone construct in all experimental and clinical studies, although there was considerable variation in the design of the studies. In randomised, controlled studies, augmentation of intracapsular fractures of the neck of the femur with calcium-phosphate cement was associated with poor long-term results. There was a lack of data on the long-term outcome for trochanteric fractures. Because there were only a few, randomised, controlled studies, there is currently poor evidence for the use of bone cement in the treatment of fractures of the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 896 - 902
1 Jul 2005
Hernigou P Poignard A Manicom O Mathieu G Rouard H