We compared lower limb coronal alignment measurements
obtained pre- and post-operatively with long-leg radiographs and
computer navigation in patients undergoing primary total knee replacement
(TKR). A series of 185 patients had their pre- and post-implant
radiological and computer-navigation system measurements of coronal alignment
compared using the Bland-Altman method. The study included 81 men
and 104 women with a mean age of 68.5 years (32 to 87) and a mean
body mass index of 31.7 kg/m2 (19 to 49). Pre-implant
Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability
coefficient of 9.0°. The Bland–Altman plot showed a tendency for the
radiological measurement to indicate a higher level of pre-operative
deformity than the corresponding navigation measurement. Post-implant
limits of agreement were -5.0° to 5.4° with a repeatability coefficient
of 5.2°. The tendency for valgus knees to have greater deformity
on the radiograph was still seen, but was weaker for varus knees. The alignment seen or measured intra-operatively during TKR is
not necessarily the same as the deformity seen on a standing long-leg
radiograph either pre- or post-operatively. Further investigation
into the effect of weight-bearing and surgical exposure of the joint
on the mechanical femorotibial angle is required to enable the most appropriate
intra-operative alignment to be selected.
Autologous chondrocyte implantation (ACI) has been used most commonly as a treatment for cartilage defects in the knee and there are few studies of its use in other joints. We describe ten patients with an osteochondral lesion of the talus who underwent ACI using cartilage taken from the knee and were prospectively reviewed with a mean follow-up of 23 months. In nine patients the satisfaction score was ‘pleased’ or ‘extremely pleased’, which was sustained at four years. The mean Mazur ankle score increased by 23 points at a mean follow-up of 23 months. The Lysholm knee score returned to the pre-operative level at one year in three patients, with the remaining seven showing a reduction of 15% at 12 months, suggesting donor-site morbidity. Nine patients underwent arthroscopic examination at one year and all were shown to have filled defects and stable cartilage. Biopsies taken from graft sites showed mostly fibrocartilage with some hyaline cartilage. The short-term results of ACI for osteochondral lesions of the talus are good despite some morbidity at the donor site.
We reviewed all patients with a clinically infected foot ulcer attending a specialised neuropathic foot clinic. Neuropathy was confirmed by the inability to feel a 5.07 Semmes-Weinstein hair, areflexia and impaired vibration sense, as measured by a biothesiometer. Of 40 patients who attended the clinic over a two-year period, six with ischaemic ulcers were excluded. The remaining 34 had plain radiographs of the foot followed by a 99mTc-MDP bone scan. If the latter was positive, an 111In-labelled WBC scan was performed with planar and/or tomographic dual-isotope studies where appropriate. Bone and WBC scans were performed in 31 patients. In ten, isotope imaging showed infection localised to the soft tissues only and conservative treatment was successful in them all. Eighteen patients were treated surgically with excision of the involved bone, which was sent for culture and histological examination. Dual-isotope scans had a sensitivity of 93% and a specificity of 83%. 99mTc-MDP bone scans with the appropriate 111In-labelled WBC scans can reliably determine the site and extent of osteomyelitis in the neuropathic diabetic foot.