The aim of this study was to report the outcomes of different treatment options for glenoid loosening following reverse shoulder arthroplasty (RSA) at a minimum follow-up of two years. We retrospectively studied the records of 79 patients (19 men, 60 women; 84 shoulders) aged 70.4 years (21 to 87) treated for aseptic loosening of the glenosphere following RSA. Clinical evaluation included pre- and post-treatment active anterior elevation (AAE), external rotation, and Constant score.Aims
Patients and Methods
The indications for reverse shoulder arthroplasty
(RSA) continue to be expanded. Associated impairment of the deltoid
muscle has been considered a contraindication to its use, as function
of the RSA depends on the deltoid and impairment of the deltoid
may increase the risk of dislocation. The aim of this retrospective
study was to determine the functional outcome and risk of dislocation
following the use of an RSA in patients with impaired deltoid function.
Between 1999 and 2010, 49 patients (49 shoulders) with impairment
of the deltoid underwent RSA and were reviewed at a mean of 38 months
(12 to 142) post-operatively. There were nine post-operative complications (18%),
including two dislocations. The mean forward elevation improved
from 50° ( These results suggest that pre-operative deltoid impairment,
in certain circumstances, is not an absolute contraindication to
RSA. This form of treatment can yield reliable improvement in function
without excessive risk of post-operative dislocation. Cite this article:
We reviewed 80 shoulders (77 patients) at a mean follow-up of 44 months after insertion of a Grammont inverted shoulder prosthesis. Three implants had failed and had been revised. The mean Constant score had increased from 22.6 points pre-operatively to 65.6 points at review. In 96% of these shoulders there was no or only minimal pain. The mean active forward elevation increased from 73° to 138°. The integrity of teres minor is essential for the recovery of external rotation and significantly influenced the Constant score. Five cases of aseptic loosening of the glenoid and seven of dissociation of the glenoid component were noted. This study confirms the promising early results obtained with the inverted prosthesis in the treatment of a cuff-tear arthropathy. It should be considered in the treatment of osteoarthritis with a massive tear of the cuff but should be reserved for elderly patients.