Advertisement for orthosearch.org.uk
Results 1 - 44 of 44
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 938 - 945
1 Aug 2022
Park YH Kim W Choi JW Kim HJ

Aims. Although absorbable sutures for the repair of acute Achilles tendon rupture (ATR) have been attracting attention, the rationale for their use remains insufficient. This study prospectively compared the outcomes of absorbable and nonabsorbable sutures for the repair of acute ATR. Methods. A total of 40 patients were randomly assigned to either braided absorbable polyglactin suture or braided nonabsorbable polyethylene terephthalate suture groups. ATR was then repaired using the Krackow suture method. At three and six months after surgery, the isokinetic muscle strength of ankle plantar flexion was measured using a computer-based Cybex dynamometer. At six and 12 months after surgery, patient-reported outcomes were measured using the Achilles tendon Total Rupture Score (ATRS), visual analogue scale for pain (VAS pain), and EuroQoL five-dimension health questionnaire (EQ-5D). Results. Overall, 37 patients completed 12 months of follow-up. No difference was observed between the two groups in terms of isokinetic plantar flexion strength, ATRS, VAS pain, or EQ-5D. No re-rupture was observed in either group. Conclusion. The use of absorbable sutures for the repair of acute ATR was not inferior to that of nonabsorbable sutures. This finding suggests that absorbable sutures can be considered for the repair of acute ATRs. Cite this article: Bone Joint J 2022;104-B(8):938–945


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 458 - 461
1 May 1997
Rossouw DJ McElroy BJ Amis AA Emery RJH

Repair of the rotator cuff requires secure reattachment, but large chronic defects cause osteoporosis of the greater tuberosity which may then have insufficient strength to allow proper fixation of the tendon. Recently, suture anchors have been introduced, but have not been fully evaluated. We have investigated the strength of suture-to-anchor attachment, and the use of suture anchors in repairs of the rotator cuff either to the greater tuberosity or the lateral cortex of the humerus. The second method gave a significant increase in the strength of the repair (p = 0.014). The repairs were loaded cyclically and failed at low loads by cutting into bone and tendon, casting doubt on the integrity of the repair in early mobilisation after surgery. Repairs with suture anchors did not perform better than those with conventional transosseous attachment


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 5 - 10
1 Jan 2023
Crowe CS Kakar S

Injury to the triangular fibrocartilage complex (TFCC) may result in ulnar wrist pain with or without instability. One component of the TFCC, the radioulnar ligaments, serve as the primary soft-tissue stabilizer of the distal radioulnar joint (DRUJ). Tears or avulsions of its proximal, foveal attachment are thought to be associated with instability of the DRUJ, most noticed during loaded pronosupination. In the absence of detectable instability, injury of the foveal insertion of the radioulnar ligaments may be overlooked. While advanced imaging techniques such as MRI and radiocarpal arthroscopy are well-suited for diagnosing central and distal TFCC tears, partial and complete foveal tears without instability may be missed without a high degree of suspicion. While technically challenging, DRUJ arthroscopy provides the most accurate method of detecting foveal abnormalities. In this annotation the spectrum of foveal injuries is discussed and a modified classification scheme is proposed.

Cite this article: Bone Joint J 2023;105-B(1):5–10.


Bone & Joint 360
Vol. 12, Issue 6 | Pages 24 - 27
1 Dec 2023

The December 2023 Foot & Ankle Roundup360 looks at: Subchondral bone cysts remodel after correction of varus deformity in ankle arthritis; 3D-printed modular endoprosthesis reconstruction following total calcanectomy; Percutaneous partial bone excision in the management of diabetic toe osteomyelitis; Hemiepiphysiodesis is a viable surgical option for Juvenile hallux valgus; Ankle arthroplasty vs arthrodesis: which comes out on top?; Patient-related risk factors for poorer outcome following total ankle arthroplasty; The Outcomes in Ankle Replacement Study.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1244 - 1251
1 Dec 2023
Plastow R Raj RD Fontalis A Haddad FS

Injuries to the quadriceps muscle group are common in athletes performing high-speed running and kicking sports. The complex anatomy of the rectus femoris puts it at greatest risk of injury. There is variability in prognosis in the literature, with reinjury rates as high as 67% in the severe graded proximal tear. Studies have highlighted that athletes can reinjure after nonoperative management, and some benefit may be derived from surgical repair to restore function and return to sport (RTS). This injury is potentially career-threatening in the elite-level athlete, and we aim to highlight the key recent literature on interventions to restore strength and function to allow early RTS while reducing the risk of injury recurrence. This article reviews the optimal diagnostic strategies and classification of quadriceps injuries. We highlight the unique anatomy of each injury on MRI and the outcomes of both nonoperative and operative treatment, providing an evidence-based management framework for athletes.

Cite this article: Bone Joint J 2023;105-B(12):1244–1251.


Bone & Joint 360
Vol. 11, Issue 6 | Pages 22 - 26
1 Dec 2022

The December 2022 Foot & Ankle Roundup360 looks at: Evans calcaneal osteotomy and multiplanar correction in flat foot deformity; Inflammatory biomarkers in tibialis posterior tendon dysfunction; Takedown of ankle fusions and conversion to total ankle arthroplasty; Surgical incision closure with three different materials; Absorbable sutures are not inferior to nonabsorbable sutures for tendo Achilles repair; Zadek’s osteotomy is a reliable technique for treating Haglund’s syndrome; How to best assess patient limitations after acute Achilles tendon injury; Advances in the management of infected nonunion of the foot and ankle.


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 4 | Pages 710 - 721
1 Nov 1967
Souter WA

1. A series of 106 central slip injuries has been reviewed. 2. Although the boutonnière deformity in many cases may be no more than a cosmetic defect, this survey has shown that in some instances it can constitute a slowly progressive lesion, with considerable disability and gross deformity of a digit. 3. Conservative treatment seems to be superior to operation, at least in those patients seen within six weeks of injury. Treatment by splintage alone yielded in this series a 75 per cent success rate, whereas operation showed only 50 per cent success. 4. When a sizeable fragment of bone has been avulsed from the middle phalanx, suture of the fragment in position is indicated and gives remarkably satisfactory results. 5. Injuries with soft-tissue loss over the proximal interphalangeal joint may yield successful results after suture or plastic repair of the tendon, and wound closure by split-skin grafts or local rotation flaps. 6. Poor results tend to occur in cases complicated by phalangeal fracture or by multiple hand injuries, and it may be advisable to defer the repair of the central slip until recovery from the other injuries has been completed. 7. With gross disruption of the proximal interphalangeal joint primary arthrodesis is probably indicated


Aims. Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. Methods. SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments. Discussion. There is currently no high-quality evidence comparing the clinical and cost effectiveness of the tension suture repair to the traditional tension band wiring currently offered for the internal fixation of displaced fractures of the olecranon. The Simple Olecranon Fracture Fixation Trial (SOFFT) is a randomized controlled trial with sufficient power and design rigour to provide this evidence for the subtype of Mayo grade IIA fractures. Cite this article: Bone Jt Open 2023;4(1):27–37


Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims

Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model.

Methods

A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 25 - 27
1 Feb 2013

The February 2013 Shoulder & Elbow Roundup. 360 . looks at: whether we should replace fractured shoulders; the limited evidence for shoulder fractures; cuffs and early physio; matrix proteins and cuff tears; long-term SLAP tear outcomes; suture anchors; recurrent Bankart repairs; and acromial morphology and calcific tendonitis


Bone & Joint 360
Vol. 10, Issue 3 | Pages 16 - 20
1 Jun 2021


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1281 - 1288
3 Oct 2020
Chang JS Kayani B Plastow R Singh S Magan A Haddad FS

Injuries to the hamstring muscle complex are common in athletes, accounting for between 12% and 26% of all injuries sustained during sporting activities. Acute hamstring injuries often occur during sports that involve repetitive kicking or high-speed sprinting, such as American football, soccer, rugby, and athletics. They are also common in watersports, including waterskiing and surfing. Hamstring injuries can be career-threatening in elite athletes and are associated with an estimated risk of recurrence in between 14% and 63% of patients. The variability in prognosis and treatment of the different injury patterns highlights the importance of prompt diagnosis with magnetic resonance imaging (MRI) in order to classify injuries accurately and plan the appropriate management.

Low-grade hamstring injuries may be treated with nonoperative measures including pain relief, eccentric lengthening exercises, and a graduated return to sport-specific activities. Nonoperative management is associated with highly variable times for convalescence and return to a pre-injury level of sporting function. Nonoperative management of high-grade hamstring injuries is associated with poor return to baseline function, residual muscle weakness and a high-risk of recurrence. Proximal hamstring avulsion injuries, high-grade musculotendinous tears, and chronic injuries with persistent weakness or functional compromise require surgical repair to enable return to a pre-injury level of sporting function and minimize the risk of recurrent injury.

This article reviews the optimal diagnostic imaging methods and common classification systems used to guide the treatment of hamstring injuries. In addition, the indications and outcomes for both nonoperative and operative treatment are analyzed to provide an evidence-based management framework for these patients.

Cite this article: Bone Joint J 2020;102-B(10):1281–1288.


Bone & Joint Open
Vol. 2, Issue 5 | Pages 305 - 313
3 May 2021
Razii N Clutton JM Kakar R Morgan-Jones R

Aims

Periprosthetic joint infection (PJI) is a devastating complication following total knee arthroplasty (TKA). Two-stage revision has traditionally been considered the gold standard of treatment for established infection, but increasing evidence is emerging in support of one-stage exchange for selected patients. The objective of this study was to determine the outcomes of single-stage revision TKA for PJI, with mid-term follow-up.

Methods

A total of 84 patients, with a mean age of 68 years (36 to 92), underwent single-stage revision TKA for confirmed PJI at a single institution between 2006 and 2016. In all, 37 patients (44%) were treated for an infected primary TKA, while the majority presented with infected revisions: 31 had undergone one previous revision (36.9%) and 16 had multiple prior revisions (19.1%). Contraindications to single-stage exchange included systemic sepsis, extensive bone or soft-tissue loss, extensor mechanism failure, or if primary wound closure was unlikely to be achievable. Patients were not excluded for culture-negative PJI or the presence of a sinus.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 933 - 940
1 Jul 2020
Maempel JF Clement ND Wickramasinghe NR Duckworth AD Keating JF

Aims

The aim was to compare long-term patient-reported outcome measures (PROMs) after operative and nonoperative treatment of acute Achilles tendon rupture in the context of a randomized controlled trial.

Methods

PROMs including the Short Musculoskeletal Function Assessment (SMFA), Achilles Tendon Total Rupture Score (ATRS), EuroQol five-dimension (EQ-5D), satisfaction, net promoter score and data regarding re-rupture, and venous thromboembolic rates were collected for patients randomized to receive either operative or nonoperative treatment for acute Achilles tendon rupture in a previous study. Of the 80 patients originally randomized, 64 (33 treated surgically, 31 nonoperatively) patients were followed up at a mean of 15.7 years (13.4 to 17.7).


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1506 - 1511
1 Dec 2019
Kim SH Yang SH Rhee S Lee KJ Kim HS Oh JH

Aims

The aim of this study was to compare the osseous reactions elicited by all-suture, polyetheretherketone (PEEK), and two different biodegradable anchors used during rotator cuff repair.

Patients and Methods

Transosseous-equivalent rotator cuff repair was performed in 73 patients. The patients were divided into two groups, in both of which two different medial-row anchors were used. In group 1, anchor A comprised 30% β-tricalcium phosphate (TCP) + 70% fast-absorbing poly lactic-co-glycolic acid copolymer (85% polylactic acid enantiomers + 15% polyglycolic acid) and anchor B comprised all-sutures. In group 2, anchor C comprised 23% micro β-TCP + 77% polylactic acid enantiomers and anchor D comprised PEEK polymer. There were 37 patients in group 1 and 36 patients in group 2. The presence and severity of fluid collection around anchors and healing of the rotator cuff were assessed using MRI scans, approximately one year postoperatively. The severity of the collection was graded as 0 (no perianchor fluid signal), 1 (minimal perianchor fluid), 2 (local collection of fluid), 3 (fluid collection around the whole length of the anchor but of a diameter less than twice the anchor diameter), or 4 (fluid collection around the whole length of the anchor and of a diameter greater than twice the anchor diameter).


Bone & Joint 360
Vol. 9, Issue 5 | Pages 24 - 28
1 Oct 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 371 - 380
1 May 1994
Gerber C Schneeberger A Beck M Schlegel U

We have studied the mechanical properties of several current techniques of tendon-to-bone suture employed in rotator-cuff repair. Non-absorbable braided polyester and absorbable polyglactin and polyglycolic acid sutures best combined ultimate tensile strength and stiffness. Polyglyconate and polydioxanone sutures failed only at high loads, but elongated considerably under moderate loads. We then compared the mechanical properties of nine different techniques of tendon grasping, using 159 normal infraspinatus tendons from sheep. The most commonly used simple stitch was mechanically poor: repairs with two or four such stitches failed at 184 N and 208 N respectively. A new modification of the Mason-Allen suture technique improved the ultimate tensile strength to 359 N for two stitches. Finally, we studied the mechanical properties of several methods of anchorage to bone using typically osteoporotic specimens. Single and even double transosseous sutures and suture anchor fixation both failed at low tensile loads (about 140 N). The use of a 2 mm thick, plate-like augmentation device improved the failure strength to 329 N. The mechanical properties of many current repair techniques are poor and can be greatly improved by using good materials, an improved tendon-grasping suture, and augmentation at the bone attachment


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 116 - 122
1 Jun 2019
Whiteside LA Roy ME

Aims. The aims of this study were to assess the exposure and preservation of the abductor mechanism during primary total hip arthroplasty (THA) using the posterior approach, and to evaluate gluteus maximus transfer to restore abductor function of chronically avulsed gluteus medius and minimus. Patients and Methods. A total of 519 patients (525 hips) underwent primary THA using the posterior approach, between 2009 and 2013. The patients were reviewed preoperatively and at two and five years postoperatively. Three patients had mild acute laceration of the gluteus medius caused by retraction. A total of 54 patients had mild chronic damage to the tendon (not caused by exposure), which was repaired with sutures through drill holes in the greater trochanter. A total of 41 patients had severe damage with major avulsion of the gluteus medius and minimus muscles, which was repaired with sutures through bone and a gluteus maximus flap transfer to the greater trochanter. Results. Abductor strength was maintained in the normal hips, but lateral hip pain progressed significantly, five years postoperatively (p < 0.0001). In the 54 patients with mild abductor tendon damage treated with simple repair, lateral hip pain also increased significantly during follow-up (p = 0.002). In the 35 patients with severe avulsion but good muscle repaired using a gluteus maximus flap transfer, abductor function was restored. The six patients with complete avulsion and poor muscle did not regain strong abductor power, but lateral hip pain decreased. Conclusion. The posterior approach offered excellent exposure and preservation of the abductor mechanism during primary THA. Augmentation of the repair with a gluteus maximus flap provided stable reconstruction of the abductor muscles and seemed to restore function in the hips with functioning muscles. Cite this article: Bone Joint J 2019;101-B(6 Supple B):116–122


Bone & Joint Research
Vol. 7, Issue 10 | Pages 561 - 569
1 Oct 2018
Yang X Meng H Quan Q Peng J Lu S Wang A

Objectives

The incidence of acute Achilles tendon rupture appears to be increasing. The aim of this study was to summarize various therapies for acute Achilles tendon rupture and discuss their relative merits.

Methods

A PubMed search about the management of acute Achilles tendon rupture was performed. The search was open for original manuscripts and review papers limited to publication from January 2006 to July 2017. A total of 489 papers were identified initially and finally 323 articles were suitable for this review.


Bone & Joint 360
Vol. 7, Issue 6 | Pages 26 - 28
1 Dec 2018


Aims

The aim of this study was to compare the clinical effectiveness of Kirschner wire (K-wire) fixation with locking-plate fixation for patients with a dorsally displaced fracture of the distal radius in the five years after injury.

Patients and Methods

We report the five-year follow-up of a multicentre, two-arm, parallel-group randomized controlled trial. A total of 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation were recruited from 18 trauma centres in the United Kingdom. Patients were excluded if the surface of the wrist joint was so badly displaced it required open reduction. In all, 448 patients were randomized to receive either K-wire fixation or locking-plate fixation. In the K-wire group, there were 179 female and 38 male patients with a mean age of 59.1 years (19 to 89). In the locking-plate group, there were 194 female and 37 male patients with a mean age of 58.3 years (20 to 89). The primary outcome measure was the patient-rated wrist evaluation (PRWE). Secondary outcomes were health-related quality of life using the EuroQol five-dimension three-level (EQ-5D-3L) assessment, and further surgery related to the index fracture.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1115 - 1121
1 Sep 2019
Takenaka S Makino T Sakai Y Kashii M Iwasaki M Yoshikawa H Kaito T

Aims

The aim of this study was to explore risk factors for complications associated with dural tear (DT), including the types of DT, and the intra- and postoperative management of DT.

Patients and Methods

Between 2012 and 2017, 12 171 patients with degenerative lumbar diseases underwent primary lumbar spine surgery. We investigated five categories of potential predictors: patient factors (sex, age, body mass index, and primary disease), surgical factors (surgical procedures, operative time, and estimated blood loss), types of DT (inaccessible for suturing/clipping and the presence of cauda equina/nerve root herniation), repair techniques (suturing, clipping, fibrin glue, polyethylene glycol (PEG) hydrogel, and polyglycolic acid sheet), and postoperative management (drainage duration). Postoperative complications were evaluated in terms of dural leak, prolonged bed rest, headache, nausea/vomiting, delayed wound healing, postoperative neurological deficit, surgical site infection (SSI), and reoperation for DT. We performed multivariable regression analyses to evaluate the predictors of postoperative complications associated with DT.


Bone & Joint 360
Vol. 8, Issue 3 | Pages 18 - 19
1 Jun 2019


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 426 - 434
1 Apr 2019
Logishetty K van Arkel RJ Ng KCG Muirhead-Allwood SK Cobb JP Jeffers JRT

Aims

The hip’s capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function.

Materials and Methods

Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips).


Bone & Joint Research
Vol. 7, Issue 7 | Pages 440 - 446
1 Jul 2018
Woods AK Broomfield J Monk P Vollrath F Glyn-Jones S

Objectives

The aim of this study was to investigate the structural integrity of torn and non-torn human acetabular labral tissue.

Methods

A total of 47 human labral specimens were obtained from a biobank. These included 22 torn specimens and 25 control specimens from patients undergoing total hip arthroplasty with macroscopically normal labra. The specimens underwent dynamic shear analysis using a rheometer to measure storage modulus, as an indicator of structural integrity.


Bone & Joint Research
Vol. 6, Issue 2 | Pages 82 - 89
1 Feb 2017
Nagra NS Zargar N Smith RDJ Carr AJ

Objectives

All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors.

Materials and Methods

A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 19 - 21
1 Dec 2014

The December 2014 Shoulder & Elbow Roundup360 looks at: cuff tears and plexus injury;

corticosteroids and physiotherapy in SAI; diabetes and elbow arthroplasty; distal biceps tendon repairs; shockwave therapy in frozen shoulder; hydrodilation and steroids for adhesive capsulitis; just what do our patients read?; and what happens to that stable radial head fracture?


Bone & Joint Research
Vol. 3, Issue 6 | Pages 193 - 202
1 Jun 2014
Hast MW Zuskov A Soslowsky LJ

Tendinopathy is a debilitating musculoskeletal condition which can cause significant pain and lead to complete rupture of the tendon, which often requires surgical repair. Due in part to the large spectrum of tendon pathologies, these disorders continue to be a clinical challenge. Animal models are often used in this field of research as they offer an attractive framework to examine the cascade of processes that occur throughout both tendon pathology and repair. This review discusses the structural, mechanical, and biological changes that occur throughout tendon pathology in animal models, as well as strategies for the improvement of tendon healing.

Cite this article: Bone Joint Res 2014;3:193–202.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1396 - 1401
1 Oct 2007
Hirpara KM Sullivan PJ Raheem O O’Sullivan ME

We compared the bulking and tensile strength of the Pennington modified Kessler, Cruciate and the Savage repairs in an ex vivo model. A total of 60 porcine tendons were randomised to three groups, half repaired using a core suture alone and the remainder employing a core and peripheral technique. The tendons were distracted to failure. The force required to produce a 3 mm gap, the ultimate strength, the mode of failure and bulking for each repair were assessed. We found that there was a significant increase in strength without an increase in bulk as the number of strands increased. The Cruciate repair was significantly more likely to fail by suture pullout than the Pennington modified Kessler or Savage repairs. We advise the use of the Savage repair, especially in the thumb, and a Cruciate when a Savage is not possible. The Pennington modified Kessler repair should be reserved for multiple tendon injuries


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 889 - 893
1 Jun 2010
Kocaoglu B Agir I Nalbantoglu U Karahan M Türkmen M

We investigated the effect of mitomycin-C on the reduction of the formation of peritendinous fibrous adhesions after tendon repair. In 20 Wistar albino rats the tendo Achillis was cut and repaired using a modified Kessler technique. The rats were divided into two equal groups. In group 1, an injection of mitomycin-C was placed between the tendon and skin of the right leg. In group 2, an identical volume of sterile normal saline was injected on the left side in a similar fashion. All the rats received mitomycin-C or saline for four weeks starting from the day of operation. The animals were killed after 30 days. The formation of peritendinous fibrous tissue, the inflammatory reaction and tendon healing were evaluated. The tensile strength of the repaired tendons was measured biomechanically. Microscopic evidence of the formation of adhesions and inflammation was less in group 1. There was no significant difference in the tensile load required to rupture the repaired tendons in the two groups.

Mitomycin-C may therefore provide a simple and inexpensive means of preventing of post-operative adhesions.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1071 - 1078
1 Aug 2011
Keating JF Will EM

A total of 80 patients with an acute rupture of tendo Achillis were randomised to operative repair using an open technique (39 patients) or non-operative treatment in a cast (41 patients). Patients were followed up for one year. Outcome measures included clinical complications, range of movement of the ankle, the Short Musculoskeletal Function Assessment (SMFA), and muscle function dynamometry evaluating dorsiflexion and plantar flexion of the ankle. The primary outcome measure was muscle dynamometry.

Re-rupture occurred in two of 37 patients (5%) in the operative group and four of 39 (10%) in the non-operative group, which was not statistically significant (p = 0.68). There was a slightly greater range of plantar flexion and dorsiflexion of the ankle in the operative group at three months which was not statistically significant, but at four and six months the range of dorsiflexion was better in the non-operative group, although this did not reach statistically significance either. After 12 weeks the peak torque difference of plantar flexion compared with the normal side was less in the operative than the non-operative group (47% vs 61%, respectively, p < 0.005). The difference declined to 26% and 30% at 26 weeks and 20% and 25% at 52 weeks, respectively. The difference in dorsiflexion peak torque from the normal side was less than 10% by 26 weeks in both groups, with no significant differences. The mean SMFA scores were significantly better in the operative group than the non-operative group at three months (15 vs 20, respectively, p < 0.03). No significant differences were observed after this, and at one year the scores were similar in both groups.

We were unable to show a convincing functional benefit from surgery for patients with an acute rupture of the tendo Achillis compared with conservative treatment in plaster.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 71 - 76
1 Jan 2010
Diklic ID Ganic ZD Blagojevic ZD Nho SJ Romeo AA

The treatment of a chronic posterior dislocation of the shoulder is often determined by the size of the associated impression fracture of the humeral head. Our hypothesis was that patients with a chronic unreduced posterior dislocation of the shoulder and a defect in the humeral head involving between 25% to 50% of the articular surface, would do better if reconstructed with an allograft from the femoral head rather than treated by a non-anatomical reconstruction. We reviewed ten men and three women with a mean age of 42 years (36 to 51) at a mean follow-up of 54 months (41 to 64) who had this procedure. At follow-up, nine had no pain or restriction of activities of daily living. Their mean Constant-Murley shoulder score was 86.8 (43 to 98). No patient had symptoms of instability of the shoulder.

Reconstruction of the defect in the humeral head with an allograft provides good pain relief, stability and function for patients with a locked, chronic posterior dislocation where the defect involves between 25% and 50% of the circumference of the articular surface.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1097 - 1100
1 Aug 2008
Tsuchihara T Nemoto K Arino H Amako M Murakami H Yoshizumi Y

Most injuries to the femoral nerve are iatrogenic in origin and occur during resection of large retroperitoneal tumours. When the defect is considerable a nerve graft is mandatory to avoid tension across the suture line. We describe two cases of iatrogenic femoral nerve injury which recovered well after reconstruction with long sural nerve grafts.

The probable reasons for success were that we performed the grafting soon after the injury, the patients were not too old, the nerve repairs were reinforced with fibrin glue and electrical stimulation of the quadriceps was administered to prevent muscle atrophy. Good functional results may be obtained if these conditions are satisfied even if the length of a nerve graft is more than 10 cm.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 169 - 175
1 Jan 2010
Dutton AQ Choong PF Goh JC Lee EH Hui JHP

We hypothesised that meniscal tears treated with mesenchymal stem cells (MSCs) together with a conventional suturing technique would show improved healing compared with those treated by a conventional suturing technique alone. In a controlled laboratory study 28 adult pigs (56 knees) underwent meniscal procedures after the creation of a radial incision to represent a tear. Group 1 (n = 9) had a radial meniscal tear which was left untreated. In group 2 (n = 19) the incision was repaired with sutures and fibrin glue and in group 3, the experimental group (n = 28), treatment was by MSCs, suturing and fibrin glue. At eight weeks, macroscopic examination of group 1 showed no healing in any specimens. In group 2 no healing was found in 12 specimens and incomplete healing in seven. The experimental group 3 had 21 specimens with complete healing, five with incomplete healing and two with no healing. Between the experimental group and each of the control groups this difference was significant (p < 0.001). The histological and macroscopic findings showed that the repair of meniscal tears in the avascular zone was significantly improved with MSCs, but that the mechanical properties of the healed menisci remained reduced


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 103 - 109
1 Jan 2010
Laffosse J Espié A Bonnevialle N Mansat P Tricoire J Bonnevialle P Chiron P Puget J

We retrospectively analysed the clinical results of 30 patients with injuries of the sternoclavicular joint at a minimum of 12 months’ follow-up. A closed reduction was attempted in 14 cases. It was successful in only five of ten dislocations, and failed in all four epiphyseal disruptions. A total of 25 patients underwent surgical reduction, in 18 cases in conjunction with a stabilisation procedure.

At a mean follow-up of 60 months, four patients were lost to follow-up. The functional results in the remainder were satisfactory, and 18 patients were able to resume their usual sports activity at the same level. There was no statistically significant difference between epiphyseal disruption and sternoclavicular dislocation (p > 0.05), but the functional scores (Simple Shoulder Test, Disability of Arm, Shoulder, Hand, and Constant scores) were better when an associated stabilisation procedure had been performed rather than reduction alone (p = 0.05, p = 0.04 and p = 0.07, respectively).

We recommend meticulous pre-operative clinical assessment with CT scans. In sternoclavicular dislocation managed within the first 48 hours and with no sign of mediastinal complication, a closed reduction can be attempted, although this was unsuccessful in half of our cases. A control CT scan is mandatory. In all other cases, and particularly if epiphyseal disruption is suspected, we recommend open reduction with a stabilisation procedure by costaclavicular cerclage or tenodesis. The use of a Kirschner wire should be avoided.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 189 - 193
1 Feb 2008
Söderlund T Mattila VM Visuri TI Pihlajamäki HK

We reviewed the outcome of arthroscopic stabilisation of anterior glenohumeral instability in young adults using the transglenoid suture technique. A questionnaire was sent to 455 consecutive patients who had undergone this procedure between 1992 and 2000. Of these, 312 patients (68.5%) with 313 affected shoulders and a mean age of 20 years (18 to 28) responded. Outcome was determined by the number of re-dislocations or, in patients who had not re-dislocated, by the disease-specific quality of life as measured by the Western Ontario Shoulder Instability index. During a mean follow-up of 6.4 years (1 to 14), 177 patients (56%) sustained a re-dislocation, including 70 who required a further operation. In 136 patients (44%) who reported neither re-dislocation nor re-operation, the index scores were good (median 90.4%; 28.9% to 100%). No significant peri- or pre-operative predictors of re-dislocation or re-operation were found. We found a high rate of re-dislocation after transglenoid suture repair in young, physically active patients


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1533 - 1538
1 Nov 2006
Meyer DC Lajtai G von Rechenberg B Pfirrmann CWA Gerber C

We released the infraspinatus tendons of six sheep, allowed retraction of the musculotendinous unit over a period of 40 weeks and then performed a repair. We studied retraction of the musculotendinous unit 35 weeks later using CT, MRI and macroscopic dissection.

The tendon was retracted by a mean of 4.7 cm (3.8 to 5.1) 40 weeks after release and remained at a mean of 4.2 cm (3.3 to 4.7) 35 weeks after the repair. Retraction of the muscle was only a mean of 2.7 cm (2.0 to 3.3) and 1.7 cm (1.1 to 2.2) respectively at these two points. Thus, the musculotendinous junction had shifted distally by a mean of 2.5 cm (2.0 to 2.8) relative to the tendon. Sheep muscle showed an ability to compensate for approximately 60% of the tendon retraction in a hitherto unknown fashion. Such retraction may not be a quantitatively reliable indicator of retraction of the muscle and may overestimate the need for elongation of the musculotendinous unit during repair.


Bone & Joint 360
Vol. 1, Issue 3 | Pages 19 - 21
1 Jun 2012

The June 2012 Shoulder & Elbow Roundup360 looks at: reverse shoulder replacement; torn rotator cuffs and platelet-rich fibrin; rotator cuff repair; frozen shoulder; whether an arthroscopic rotator cuff repair actually heals; the torn rotator cuff’s effect on activities of daily living; subacromial impingement; how to improve the reliability of the Constant-Murley score; and failure of the Neer modification of an open Bankart procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1165 - 1170
1 Aug 2010
Hirpara KM Sullivan PJ O’Sullivan ME

We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiöld type B cross-stitch. The repairs were loaded to failure and a record made of their bulk, the force required to produce a 3 mm gap, the maximum force applied before failure and the stiffness. When only one device was used repairs were equivalent to the Pennington modified Kessler for all parameters except the force to produce a 3 mm gap when supplemented with a circumferential repair, which was equivalent to the cruciate.

When two devices were used the repair strength was equivalent to the cruciate repair, and when the two-device repair was supplemented with a circumferential suture the force to produce a 3 mm gap was equivalent to that of the Savage six-strand technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1462 - 1467
1 Nov 2008
Patel RV Apostle K Leith JM Regan WD

We have investigated the outcome of arthroscopic revision surgery for recurrent instability of the shoulder after failed primary anterior stabilisation. We identified 40 patients with failed primary open or arthroscopic anterior stabilisation of the shoulder who had been treated by revision arthroscopic capsulolabral reconstruction and followed up for a mean of 36 months (12 to 87). There were 34 men and six women with a mean age of 33.1 years (15 to 48). Details of the patients, the technique of the primary procedure, the operative findings at revision and the clinical outcome were evaluated by reviewing the medical records, physical examination and the use of the Western Ontario shoulder instability index score, the American Shoulder and Elbow Surgeons score and the health status questionnaire 12.

Recurrent instability persisted in four patients after the revision arthroscopic procedure. At the final follow-up, the mean American Shoulder and Elbow Surgeons score was 81.1 (17.5 to 99.5) and the mean Western Ontario shoulder instability index score was 68.2 (20 to 98.2). Quality-of-life scoring showed good to excellent results in most patients.

Arthroscopic revision capsulolabral reconstruction can provide a satisfactory outcome in selected patients for recurrent instability of the shoulder provided that no large Hill-Sachs lesion is present.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 911 - 914
1 Jul 2007
Khan WS Nokes L Jones RK Johnson DS

We describe the influence of the angle of immobilisation during partial weight-bearing on the forces across the extensor mechanism of the knee. Gait analysis was performed on eight healthy male subjects with the right knee in an orthotic brace locked at 0°, 10°, 20° and 30°, with the brace unlocked and also without a brace. The ground reaction force, the angle of the knee and the net external flexion movement about the knee were measured and the extensor mechanism force was calculated.

The results showed a direct non-linear relationship between the angle of knee flexion and the extensor mechanism force. When a brace was applied, the lowest forces occurred when the brace was locked at 0°. At 30° the forces approached the failure strength of some fixation devices. We recommend that for potentially unstable injuries of the extensor mechanism, when mobilising with partial weight-bearing, the knee should be flexed at no more than 10°.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1341 - 1347
1 Oct 2008
Levy O Venkateswaran B Even T Ravenscroft M Copeland S

We have conducted a prospective study to assess the mid-term clinical results following arthroscopic repair of the rotator cuff. Patients were evaluated using the Constant score, subjective satisfaction levels and post-operative ultrasound scans.

Of 115 consecutive patients who underwent arthroscopic repair of the rotator cuff at our institution, 102 were available for follow-up. The mean period of follow-up was for 35.8 months (24 to 73). The mean age of the patients was 57.3 years (23 to 78). There were 18 small (≤ 1 cm in diameter), 44 medium (1 cm to 3 cm in diameter), 34 large (3 cm to 5 cm in diameter) and six massive (> 5 cm in diameter) tears. There was a statistically significant increase in the size of the tear with increasing age (p = 0.0048).

The mean pre-operative Constant score was 41.4 points (95% confidence interval, 37.9 to 44.9), which improved to 84.5 (95% confidence interval, 82.2 to 86.9). A significant inverse association (p = 0.0074), was observed between the size of the tear and the post-operative Constant score, with patients having smaller tears attaining higher Constant scores after repair. Post-operatively, 80 patients (78.4%) were able to resume their occupations and 84 (82.4%) returned to their pre-injury leisure activities. Only eight (7.8%) of 102 patients were not satisfied with the outcome.

Recurrent tears were detected by ultrasound in 19 (18.6%) patients, and were generally smaller than the original ones. Patients with recurrent tears experienced a mean improvement of 31.6 points (95% confidence interval, 23.6 to 39.6) in their post-operative Constant scores. Those with intact repairs had significantly improved (p < 0.0001) Constant scores (mean improvement 46.3 points, 95% confidence interval, 41.9 to 50.6). Patient satisfaction was high in 94 cases (92%), irrespective of the outcome of the Constant score. Recurrent tears appear to be linked to age-related degeneration.

Arthroscopic repair of the rotator cuff leads to high rates of satisfaction (92%) and good functional results, albeit with a recurrence rate of 18.6% (19 of 102).


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 36 - 40
1 Jan 2005
Mountney J Senavongse W Amis AA Thomas NP

The tensile strength of the medial patellofemoral ligament (MPFL), and of surgical procedures which reconstitute it, are unknown. Ten fresh cadaver knees were prepared by isolating the patella, leaving only the MPFL as its attachment to the medial femoral condyle. The MPFL was either repaired by using a Kessler suture or reconstructed using either bone anchors or one of two tendon grafting techniques. The tensile strength and the displacement to peak force of the MPFL were then measured using an Instron materials-testing machine.

The MPFL was found to have a mean tensile strength of 208 N (SD 90) at 26 mm (SD 7) of displacement. The strengths of the other techniques were: sutures alone, 37 N (SD 27); bone anchors plus sutures, 142 N (SD 39); blind-tunnel tendon graft, 126 N (SD 21); and through-tunnel tendon graft, 195 N (SD 66). The last was not significantly weaker than the MPFL itself.