header advert
Results 1 - 39 of 39
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 456 - 462
1 May 1998

The final results up to 15 years are reported of clinical trials of the management of tuberculosis of the spine in Korea and Hong Kong. In Korea, 350 patients with active spinal tuberculosis were randomised to ambulatory chemotherapy or bed rest in hospital (in Masan) or a plaster-of-Paris jacket for nine months (in Pusan). Patients in both centres were also randomised to either PAS plus isoniazid for 18 months or to the same drugs plus streptomycin for the first three months. In Hong Kong, all 150 patients were treated with the three-drug regime and randomised to either radical excision of the spinal lesion with bone graft or open debridement. On average, the disease was more extensive in Korea, but at 15 years (or 13 or 14 years in a proportion of the patients in Korea) the great majority of patients in both countries achieved a favourable status, no evidence of CNS involvement, no radiological evidence of disease, no sinus or clinically evident abscess, and no restriction of normal physical activity. Most patients had already achieved a favourable status much earlier. The earlier results of these trials are confirmed by the long-term follow-up with no late relapse or late-onset paraplegia. The results of chemotherapy on an outpatient basis were not improved by bed rest or a plaster jacket and the only advantage of the radical operation was less late deformity compared with debridement. A second series of studies has shown that short-course regimes based on isoniazid and rifampicin are as effective as the 18-month regimes: ambulatory chemotherapy with these regimes should now be the main management of uncomplicated spinal tuberculosis


Bone & Joint Research
Vol. 11, Issue 8 | Pages 575 - 584
17 Aug 2022
Stoddart JC Garner A Tuncer M Cobb JP van Arkel RJ

Aims. The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA). Methods. Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95. th. percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone. Results. Peak tensile strains occurred on the anterior portion of the medial sagittal cut in all simulations. Lateral translation of the medial implant in Bi-UKA had the largest increase in ROF of any of the implant positions (43%). Overstuffing the joint by 2 mm had a much larger effect, resulting in a six-fold increase in ROF. Bi-UKA had ~10% increased ROF compared to UKA-M for both the male and female models, although the smaller, less dense female model had a 1.4 times greater ROF compared to the male model. Removal of anterior bone akin to BCR-TKA doubled ROF compared to Bi-UKA. Conclusion. Tibial eminence avulsion fracture has a similar risk associated with Bi-UKA to UKA-M. The risk is higher for smaller and less dense tibiae. To minimize risk, it is most important to avoid overstuffing the joint, followed by correctly positioning the medial implant, taking care not to narrow the bone island anteriorly. Cite this article: Bone Joint Res 2022;11(8):575–584


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1118 - 1125
4 Oct 2022
Suda Y Hiranaka T Kamenaga T Koide M Fujishiro T Okamoto K Matsumoto T

Aims

A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting.

Methods

This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1209 - 1214
1 Nov 2022
Owen AR Amundson AW Larson DR Duncan CM Smith HM Johnson RL Taunton MJ Pagnano MW Berry DJ Abdel MP

Aims

Spinal anaesthesia has seen increased use in contemporary primary total knee arthroplasties (TKAs). However, controversy exists about the benefits of spinal in comparison to general anaesthesia in primary TKAs. This study aimed to investigate the pain control, length of stay (LOS), and complications associated with spinal versus general anaesthesia in primary TKAs from a single, high-volume academic centre.

Methods

We retrospectively identified 17,690 primary TKAs (13,297 patients) from 2001 to 2016 using our institutional total joint registry, where 52% had general anaesthesia and 48% had spinal anaesthesia. Baseline characteristics were similar between cohorts with a mean age of 68 years (SD 10), 58% female (n = 7,669), and mean BMI of 32 kg/m2 (SD 7). Pain was evaluated using oral morphine equivalents (OMEs) and numerical pain rating scale (NPRS) data. Complications including 30- and 90-day readmissions were studied. Data were analyzed using an inverse probability of treatment weighted model based on propensity score that included many patient and surgical factors. Mean follow-up was seven years (2 to 18).


Bone & Joint Research
Vol. 5, Issue 5 | Pages 198 - 205
1 May 2016
Wang WJ Liu F Zhu Y Sun M Qiu Y Weng WJ

Objectives. Normal sagittal spine-pelvis-lower extremity alignment is crucial in humans for maintaining an ergonomic upright standing posture, and pathogenesis in any segment leads to poor balance. The present study aimed to investigate how this sagittal alignment can be affected by severe knee osteoarthritis (KOA), and whether associated changes corresponded with symptoms of lower back pain (LBP) in this patient population. Methods. Lateral radiograph films in an upright standing position were obtained from 59 patients with severe KOA and 58 asymptomatic controls free from KOA. Sagittal alignment of the spine, pelvis, hip and proximal femur was quantified by measuring several radiographic parameters. Global balance was accessed according to the relative position of the C7 plumb line to the sacrum and femoral heads. The presence of chronic LBP was documented. Comparisons between the two groups were carried by independent samples t-tests or chi-squared test. Results. Patients with severe KOA showed significant backward femoral inclination (FI), hip flexion, forward spinal inclination, and higher prevalence of global imbalance (27.1% versus 3.4%, p < 0.001) compared with controls. In addition, patients with FI of 10° (n = 23) showed reduced lumbar lordosis and significant forward spinal inclination compared with controls, whereas those with FI > 10° (n = 36) presented with significant pelvic anteversion and hip flexion. A total of 39 patients with KOA (66.1%) suffered from LBP. There was no significant difference in sagittal alignment between KOA patients with and without LBP. Conclusions. The sagittal alignment of spine-pelvis-lower extremity axis was significantly influenced by severe KOA. The lumbar spine served as the primary source of compensation, while hip flexion and pelvic anteversion increased for further compensation. Changes in sagittal alignment may not be involved in the pathogenesis of LBP in this patient population. Cite this article: W. J. Wang, F. Liu, Y.W. Zhu, M.H. Sun, Y. Qiu, W. J. Weng. Sagittal alignment of the spine-pelvis-lower extremity axis in patients with severe knee osteoarthritis: A radiographic study. Bone Joint Res 2016;5:198–205. DOI:10.1302/2046-3758.55.2000538


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1561 - 1570
1 Oct 2021
Blyth MJG Banger MS Doonan J Jones BG MacLean AD Rowe PJ

Aims

The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively.

Methods

A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1498 - 1501
1 Nov 2005
Grelsamer RP Dubey A Weinstein CH

The Q angle is an important determinant of patellar tracking, though its clinical relevance is debatable. One controversy centres around any possible differences in its value between men and women. The accepted, though unproven explanation, for the greater Q angle in women is that a woman has a wider pelvis. However, because of the long distance between the pelvis and patella, relative to the distance from the patella to the tibial tuberosity, large changes in the position of the anterior superior iliac spine are necessary to effect significant changes in the Q angle. In our study of 69 subjects, we did not find such large differences in the position of the anterior superior iliac spine, and found a mean difference of only 2.3° between the Q angles of men and women. Furthermore, we found that men and women of equal height demonstrated similar Q angles, with taller people having slightly smaller Q angles. The slight difference in Q angles between men and women can be explained by the fact that men tend to be taller


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 81 - 86
1 Jun 2021
Mahfouz MR Abdel Fatah EE Johnson JM Komistek RD

Aims

The objective of this study is to assess the use of ultrasound (US) as a radiation-free imaging modality to reconstruct 3D anatomy of the knee for use in preoperative templating in knee arthroplasty.

Methods

Using an US system, which is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allows 3D tracking of the probe, femur, and tibia. The raw US radiofrequency (RF) signals are acquired and, using real-time signal processing, bone boundaries are extracted. Bone boundaries and the tracking information are fused in a 3D point cloud for the femur and tibia. Using a statistical shaping model, the patient-specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was conducted for 17 cadavers by comparing the 3D US models with those created using CT. US scans from 15 users were compared in order to examine the effect of operator variability on the output.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 67 - 73
1 Jun 2021
Lee G Wakelin E Randall A Plaskos C

Aims

Neither a surgeon’s intraoperative impression nor the parameters of computer navigation have been shown to be predictive of the outcomes following total knee arthroplasty (TKA). The aim of this study was to determine whether a surgeon, with robotic assistance, can predict the outcome as assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) for pain (KPS), one year postoperatively, and establish what factors correlate with poor KOOS scores in a well-aligned and balanced TKA.

Methods

A total of 134 consecutive patients who underwent TKA using a dynamic ligament tensioning robotic system with a tibia first resection technique and a cruciate sacrificing ultracongruent TKA system were enrolled into a prospective study. Each TKA was graded based on the final mediolateral ligament balance at 10° and 90° of flexion: 1) < 1 mm difference in the thickness of the tibial insert and that which was planned (n = 75); 2) < 1 mm difference (n = 26); 3) between 1 mm to 2 mm difference (n = 26); and 4) > 2 mm difference (n = 7). The mean one-year KPS score for each grade of TKA was compared and the likelihood of achieving an KPS score of > 90 was calculated. Finally, the factors associated with lower KPS despite achieving a high-grade TKA (grade A and B) were analyzed.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 272 - 278
1 Jun 2020
Tapasvi S Shekhar A Patil S Pandit H

Aims

The mobile bearing Oxford unicompartmental knee arthroplasty (OUKA) is recommended to be performed with the leg in the hanging leg (HL) position, and the thigh placed in a stirrup. This comparative cadaveric study assesses implant positioning and intraoperative kinematics of OUKA implanted either in the HL position or in the supine leg (SL) position.

Methods

A total of 16 fresh-frozen knees in eight human cadavers, without macroscopic anatomical defects, were selected. The knees from each cadaver were randomized to have the OUKA implanted in the HL or SL position.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 794 - 798
1 Jun 2010
Minoda Y Ikebuchi M Kobayashi A Iwaki H Inori F Nakamura H

Bone mineral density (BMD) around the femoral component has been reported to decrease after total knee replacement (TKR) because of stress shielding. Our aim was to determine whether a cemented mobile-bearing component reduced the post-operative loss of BMD. In our study 28 knees receiving a cemented fixed-bearing TKR were matched with 28 receiving a cemented mobile-bearing TKR. They underwent dual-energy x-ray absorptiometry, pre-operatively and at three weeks and at three, six, 12, 18 and 24 months post-operatively. The patients were not taking medication to improve the BMD. The pre-operative differences in the BMD of the femoral neck, wrist, lumbar spine and knee in the two groups were not significant. The BMD of the femur decreased postoperatively in the fixed-bearing group, but not the mobile-bearing group. The difference in the post-operative change in the BMD in the two groups was statistically significant (p < 0.05) at 18 and 24 months. Our findings show that a cemented mobile-bearing TKR has a favourable effect on the BMD of the distal femur after TKR in the short term. Further study is required to determine the long-term effects


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 861 - 867
1 Jul 2020
Hiranaka T Yoshikawa R Yoshida K Michishita K Nishimura T Nitta S Takashiba K Murray D

Aims

Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia.

Methods

The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 10 - 18
1 Jun 2020
Ueyama H Kanemoto N Minoda Y Taniguchi Y Nakamura H

Aims

The aim of this study was to assess the effectiveness of perioperative essential amino acid (EAA) supplementation to prevent rectus femoris muscle atrophy and facilitate early recovery of function after total knee arthroplasty (TKA).

Methods

The study involved 60 patients who underwent unilateral TKA for primary knee osteo-arthritis (OA). This was a double-blind, placebo-controlled, randomized control trial with patients randomly allocated to two groups, 30 patients each: the essential amino acid supplementation (9 g daily) and placebo (lactose powder, 9 g daily) groups. Supplementation and placebo were provided from one week before to two weeks after surgery. The area of the rectus femoris muscle were measured by ultrasound imaging one month before surgery and one, two, three, and four weeks postoperatively. The serum albumin level, a visual analogue knee pain score, and mobility were also measured at each time point. The time to recovery of activities of daily living (ADLs) was recorded. Postoperative nutrition and physiotherapy were identical in both groups.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1081 - 1086
1 Sep 2019
Murphy WS Harris S Pahalyants V Zaki MM Lin B Cheng T Talmo C Murphy SB

Aims

The practice of alternating operating theatres has long been used to reduce surgeon idle time between cases. However, concerns have been raised as to the safety of this practice. We assessed the payments and outcomes of total knee arthroplasty (TKA) performed during overlapping and nonoverlapping days, also comparing the total number of the surgeon’s cases and the total time spent in the operating theatre per day.

Materials and Methods

A retrospective analysis was performed on the Centers for Medicare & Medicaid Services (CMS) Limited Data Set (LDS) on all primary elective TKAs performed at the New England Baptist Hospital between January 2013 and June 2016. Using theatre records, episodes were categorized into days where a surgeon performed overlapping and nonoverlapping lists. Clinical outcomes, economic outcomes, and demographic factors were calculated. A regression model controlling for the patient-specific factors was used to compare groups. Total orthopaedic cases and aggregate time spent operating (time between skin incision and closure) were also compared.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 22 - 27
1 Jul 2019
Kalbian IL Tan TL Rondon AJ Bonaddio VA Klement MR Foltz C Lonner JH

Aims

Unicompartmental knee arthroplasty (UKA) provides improved early functional outcomes and less postoperative morbidity and pain compared with total knee arthroplasty (TKA). Opioid prescribing has increased in the last two decades, and recently states in the USA have developed online Prescription Drug Monitoring Programs to prevent overprescribing of controlled substances. This study evaluates differences in opioid requirements between patients undergoing TKA and UKA.

Patients and Methods

We retrospectively reviewed 676 consecutive TKAs and 241 UKAs. Opioid prescriptions in morphine milligram equivalents (MMEs), sedatives, benzodiazepines, and stimulants were collected from State Controlled Substance Monitoring websites six months before and nine months after the initial procedures. Bivariate and multivariate analysis were performed for patients who had a second prescription and continued use.


Bone & Joint Research
Vol. 7, Issue 7 | Pages 468 - 475
1 Jul 2018
He Q Sun H Shu L Zhu Y Xie X Zhan Y Luo C

Objectives

Researchers continue to seek easier ways to evaluate the quality of bone and screen for osteoporosis and osteopenia. Until recently, radiographic images of various parts of the body, except the distal femur, have been reappraised in the light of dual-energy X-ray absorptiometry (DXA) findings. The incidence of osteoporotic fractures around the knee joint in the elderly continues to increase. The aim of this study was to propose two new radiographic parameters of the distal femur for the assessment of bone quality.

Methods

Anteroposterior radiographs of the knee and bone mineral density (BMD) and T-scores from DXA scans of 361 healthy patients were prospectively analyzed. The mean cortical bone thickness (CBTavg) and the distal femoral cortex index (DFCI) were the two parameters that were proposed and measured. Intra- and interobserver reliabilities were assessed. Correlations between the BMD and T-score and these parameters were investigated and their value in the diagnosis of osteoporosis and osteopenia was evaluated.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 340 - 347
1 Mar 2019
Elkassabany NM Cai LF Badiola I Kase B Liu J Hughes C Israelite CL Nelson CL

Aims

Adductor canal block (ACB) has emerged as an alternative to femoral nerve block (FNB) for analgesia after total knee arthroplasty (TKA). The optimal duration of maintenance of the ACB is still questionable. The purpose of this study was to compare the analgesic benefits and physiotherapy (PT) outcomes of single-shot ACB to two different regimens of infusion of the continuous ACB, 24-hour and 48-hour infusion.

Patients and Methods

This was a prospective, randomized, unblinded study. A total of 159 American Society of Anesthesiologists (ASA) physical status I to III patients scheduled for primary TKA were randomized to one of three study groups. Three patients did not complete the study, leaving 156 patients for final analysis. Group A (n = 53) was the single-shot group (16 female patients and 37 male patients with a mean age of 63.9 years (sd 9.6)), group B (n = 51) was the 24-hour infusion group (22 female patients and 29 male patients with a mean age of 66.5 years (sd 8.5)), and group C (n = 52) was the 48-hour infusion group (18 female patients and 34 male patients with a mean age of 62.2 years (sd 8.7)). Pain scores, opioid requirements, PT test results, and patient-reported outcome instruments were compared between the three groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 345 - 347
1 Apr 2001
Harcourt WGV White SH Jones P

There is a need for the accurate measurement of the outcome after knee surgery. The Oxford Knee Score is being increasingly used since it is reported to be short, simple, inexpensive and validated. We sent the questionnaire to 346 patients awaiting surgery to the hip or lumbar spine. Only 11% of 141 patients with proximal pathology who denied knee problems gave a maximum score. Their mean score was substantially lower than expected at 28.7 (maximum 48), and was significantly lower than the score of 36.5 obtained from patients after total knee replacement. We therefore suggest that the frequent coexistence of hip or spinal pathology will significantly alter both the absolute score and any improvement to be expected after knee surgery. Although sensitive to disability originating from the knee the Oxford Knee Score is not sufficiently specific since it is heavily influenced by more proximal pathology


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 344 - 350
1 Mar 2017
Metcalfe AJ Clark DA Kemp MA Eldridge JD

Aims

The Bereiter trochleoplasty has been used in our unit for 12 years to manage recurrent patellar instability in patients with severe trochlea dysplasia. The aim of this study was to document the outcome of a large consecutive cohort of patients who have undergone this operation.

Patients and Methods

Between June 2002 and August 2013, 214 consecutive trochleoplasties were carried out in 185 patients. There were 133 women and 52 men with a mean age of 21.3 years (14 to 38). All patients were offered yearly clinical and radiological follow-up. They completed the following patient reported outcome scores (PROMs): International Knee Documentation Committee subjective scale, the Kujala score, the Western Ontario and McMaster Universities Arthritis Index score and the short-form (SF)-12.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 49 - 57
1 Jan 2016
Bonnin MP Saffarini M Bossard N Dantony E Victor J

Aims

Analysis of the morphology of the distal femur, and by extension of the femoral components in total knee arthroplasty (TKA), has largely been related to the aspect ratio, which represents the width of the femur. Little is known about variations in trapezoidicity (i.e. whether the femur is more rectangular or more trapezoidal). This study aimed to quantify additional morphological characteristics of the distal femur and identify anatomical features associated with higher risks of over- or under-sizing of components in TKA.

Methods

We analysed the shape of 114 arthritic knees at the time of primary TKA using the pre-operative CT scans. The aspect ratio and trapezoidicity ratio were quantified, and the post-operative prosthetic overhang was calculated. We compared the morphological characteristics with those of 12 TKA models.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1498 - 1502
1 Nov 2014
Riis A Rathleff MS Jensen MB Simonsen O

The optimal timing of total knee replacement (TKR) in patients with osteoarthritis, in relation to the severity of disease, remains controversial. This prospective study was performed to investigate the effect of the severity of osteoarthritis and other commonly available pre- and post-operative clinical parameters on the clinical outcome in a consecutive series of cemented TKRs. A total of 176 patients who underwent unilateral TKR were included in the study. Their mean age was 68 years (39 to 91), 63 (36%) were male and 131 knees (74%) were classified as grade 4 on the Kellgren–Lawrence osteoarthritis scale. A total of 154 patients (87.5%) returned for clinical review 12 months post-operatively, at which time the outcome was assessed using the Knee Society score.

A low radiological severity of osteoarthritis was not associated with pain 12 months post-operatively. However, it was significantly associated with an inferior level of function (p = 0.007), implying the need for increased focus on all possible reasons for pain in the knee and the forms of conservative treatment which are available for patients with lower radiological severity of osteoarthritis.

Cite this article: Bone Joint J 2014; 96-B:1498–1502.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1051 - 1057
1 Aug 2012
Nutton RW Wade FA Coutts FJ van der Linden ML

This prospective randomised controlled double-blind trial compared two types of PFC Sigma total knee replacement (TKR), differing in three design features aimed at improving flexion. The outcome of a standard fixed-bearing posterior cruciate ligament-preserving design (FB-S) was compared with that of a high-flexion rotating-platform posterior-stabilised design (RP-F) at one year after TKR.

The study group of 77 patients with osteoarthritis of the knee comprised 37 men and 40 women, with a mean age of 69 years (44.9 to 84.9). The patients were randomly allocated either to the FB-S or the RP-F group and assessed pre-operatively and at one year post-operatively. The mean post-operative non-weight-bearing flexion was 107° (95% confidence interval (CI) 104° to 110°)) for the FB-S group and 113° (95% CI 109° to 117°) for the RP-F group, and this difference was statistically significant (p = 0.032). However, weight-bearing range of movement during both level walking and ascending a slope as measured during flexible electrogoniometry was a mean of 4° lower in the RP-F group than in the FB-S group, with 58° (95% CI 56° to 60°) versus 54° (95% CI 51° to 57°) for level walking (p = 0.019) and 56° (95% CI 54° to 58°) versus 52° (95% CI 48° to 56°) for ascending a slope (p = 0.044). Further, the mean post-operative pain score of the Western Ontario and McMaster Universities Osteoarthritis Index was significantly higher in the RP-F group (2.5 (95% CI 1.5 to 3.5) versus 4.2 (95% CI 2.9 to 5.5), p = 0.043).

Although the RP-F group achieved higher non-weight-bearing knee flexion, patients in this group did not use this during activities of daily living and reported more pain one year after surgery.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 120 - 123
1 Nov 2013
Drexler M Dwyer T Chakravertty R Farno A Backstein D

Total knee replacement (TKR) is one of the most common operations in orthopaedic surgery worldwide. Despite its scientific reputation as mainly successful, only 81% to 89% of patients are satisfied with the final result. Our understanding of this discordance between patient and surgeon satisfaction is limited. In our experience, focus on five major factors can improve patient satisfaction rates: correct patient selection, setting of appropriate expectations, avoiding preventable complications, knowledge of the finer points of the operation, and the use of both pre- and post-operative pathways. Awareness of the existence, as well as the identification of predictors of patient–surgeon discordance should potentially help with enhancing patient outcomes.

Cite this article: Bone Joint J 2013;95-B, Supple A:120–3.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1632 - 1639
1 Dec 2013
Clement ND MacDonald D Simpson AHRW Burnett R

This study assessed the effect of concomitant back pain on the Oxford knee score (OKS), Short-Form (SF)-12 and patient satisfaction after total knee replacement (TKR). It involved a prospectively compiled database of demographics and outcome scores for 2392 patients undergoing primary TKR, of whom 829 patients (35%) reported back pain. Compared with those patients without back pain, those with back pain were more likely to be female (odds ratio (OR) 1.5 (95% confidence interval (CI) 1.3 to 1.8)), have a greater level of comorbidity, a worse pre-operative OKS (2.3 points (95% CI 1.7 to 3.0)) and worse SF-12 physical (2.0 points (95% CI 1.4 to 2.6)) and mental (3.3 points (95% CI 2.3 to 4.3)) components.

One year post-operatively, those with back pain had significantly worse outcome scores than those without with a mean difference in the OKS of 5 points (95% CI 3.8 to 5.4), in the SF-12 physical component of 6 points (95% CI 5.4 to 7.1) and in the mental component of 4 points (95% CI 3.1 to 4.9). Patients with back pain were less likely to be satisfied (OR 0.62, 95% CI 0.5 to 0.78).

After adjusting for confounding variables, concomitant back pain was an independent predictor of a worse post-operative OKS, and of dissatisfaction. Clinicians should be aware that patients suffering concomitant back pain pre-operatively are at an increased risk of being dissatisfied post-operatively.

Cite this article: Bone Joint J 2013;95-B:1632–9.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1348 - 1353
1 Oct 2013
Valenzuela GA Jacobson NA Buzas D Korecki TD Valenzuela RG Teitge RA

The outcome of high tibial osteotomy (HTO) deteriorates with time, and additional procedures may be required. The aim of this study was to compare the clinical and radiological outcomes between unicompartmental knee replacement (UKR) and total knee replacement (TKR) after HTO as well as after primary UKR. A total of 63 patients (63 knees) were studied retrospectively and divided into three groups: UKR after HTO (group A; n = 22), TKR after HTO (group B; n = 18) and primary UKR (group C; n = 22). The Oxford knee score (OKS), Knee Society score (KSS), hip–knee–ankle angles, mechanical axis and patellar height were evaluated pre- and post-operatively. At a mean of 64 months (19 to 180) post-operatively the mean OKS was 43.8 (33 to 49), 43.3 (30 to 48) and 42.5 (29 to 48) for groups A, B and C, respectively (p = 0.73). The mean KSS knee score was 88.8 (54 to 100), 88.11 (51 to 100) and 85.3 (45 to 100) for groups A, B and C, respectively (p = 0.65), and the mean KSS function score was 85.0 (50 to 100) in group A, 85.8 (20 to 100) in group B and 79.3 (50 to 100) in group C (p = 0.48). Radiologically the results were comparable for all groups except for patellar height, with a higher incidence of patella infra following a previous HTO (p = 0.02).

Cite this article: Bone Joint J 2013;95-B:1348–53.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 348 - 353
1 Mar 2013
Metcalfe AJ Stewart C Postans N Dodds AL Holt CA Roberts AP

The aim of this study was to examine the loading of the other joints of the lower limb in patients with unilateral osteoarthritis (OA) of the knee. We recruited 20 patients with no other symptoms or deformity in the lower limbs from a consecutive cohort of patients awaiting knee replacement. Gait analysis and electromyographic recordings were performed to determine moments at both knees and hips, and contraction patterns in the medial and lateral quadriceps and hamstrings bilaterally. The speed of gait was reduced in the group with OA compared with the controls, but there were only minor differences in stance times between the limbs. Patients with OA of the knee had significant increases in adduction moment impulse at both knees and the contralateral hip (adjusted p-values: affected knee: p < 0.01, unaffected knee p = 0.048, contralateral hip p = 0.03), and significantly increased muscular co-contraction bilaterally compared with controls (all comparisons for co-contraction, p < 0.01).

The other major weight-bearing joints are at risk from abnormal biomechanics in patients with unilateral OA of the knee.

Cite this article: Bone Joint J 2013;95-B:348–53.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 137 - 140
1 Nov 2012
Jones RE Russell RD Huo MH

Most problems encountered in complex revision total knee arthroplasty can be managed with the wide range of implant systems currently available. Modular metaphyseal sleeves, metallic augments and cones provide stability even with significant bone loss. Hinged designs substitute for significant ligamentous deficiencies. Catastrophic failure that precludes successful reconstruction can be encountered. The alternatives to arthroplasty in such drastic situations include knee arthrodesis, resection arthroplasty and amputation. The relative indications for the selection of these alternatives are recurrent deep infection, immunocompromised host, and extensive non-reconstructible bone or soft-tissue defects.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 112 - 115
1 Nov 2012
Su EP

Fixed flexion deformities are common in osteoarthritic knees that are indicated for total knee arthroplasty. The lack of full extension at the knee results in a greater force of quadriceps contracture and energy expenditure. It also results in slower walking velocity and abnormal gait mechanics, overloading the contralateral limb. Residual flexion contractures after TKA have been associated with poorer functional scores and outcomes.

Although some flexion contractures may resolve with time after surgery, a substantial percentage will become permanent. Therefore, it is essential to correct fixed flexion deformities at the time of TKA, and be vigilant in the post-operative course to maintain the correction.

Surgical techniques to address pre-operative flexion contractures include: adequate bone resection, ligament releases, removal of posterior osteophytes, and posterior capsular releases. Post-operatively, extension can be maintained with focused physiotherapy, a specially modified continuous passive motion machine, a contralateral heel lift, and splinting.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1457 - 1461
1 Nov 2012
Krishnan SP Dawood A Richards R Henckel J Hart AJ

Improvements in the surgical technique of total knee replacement (TKR) are continually being sought. There has recently been interest in three-dimensional (3D) pre-operative planning using magnetic resonance imaging (MRI) and CT. The 3D images are increasingly used for the production of patient-specific models, surgical guides and custom-made implants for TKR.

The users of patient-specific instrumentation (PSI) claim that they allow the optimum balance of technology and conventional surgery by reducing the complexity of conventional alignment and sizing tools. In this way the advantages of accuracy and precision claimed by computer navigation techniques are achieved without the disadvantages of additional intra-operative inventory, new skills or surgical time.

This review describes the terminology used in this area and debates the advantages and disadvantages of PSI.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 103 - 111
1 Nov 2012
Vince KG

Seven stiff total knee arthroplasties are presented to illustrate the roles of: 1) manipulation under general anesthesia; 2) multiple concurrent diagnoses in addition to stiffness; 3) extra-articular pathology; 4) pain as part of the stiffness triad (pain and limits to flexion or extension); 5) component internal rotation; 6) multifactorial etiology; and 7) surgical exposure in this challenging clinical problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1511 - 1516
1 Nov 2012
Chang CB Cho W

In a prospective multicentre study we investigated variations in pain management used by knee arthroplasty surgeons in order to compare the differences in pain levels among patients undergoing total knee replacements (TKR), and to compare the effectiveness of pain management protocols. The protocols, peri-operative levels of pain and patient satisfaction were investigated in 424 patients who underwent TKR in 14 hospitals. The protocols were highly variable and peri-operative pain levels varied substantially, particularly during the first two post-operative days. Differences in levels of pain were greatest during the night after TKR, when visual analogue scores ranged from 16.9 to 94.3 points.

Of the methods of managing pain, the combined use of peri-articular infiltration and nerve blocks provided better pain relief than other methods during the first two post-operative days. Patients managed with peri-articular injection plus nerve block, and epidural analgesia were more likely to have higher satisfaction at two weeks after TKR. This study highlights the need to establish a consistent pain management strategy after TKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 606 - 613
1 May 2006
Abu-Rajab RB Watson WS Walker B Roberts J Gallacher SJ Meek RMD

We compared peri-prosthetic bone mineral density between identical cemented and cementless LCS rotating platform total knee arthroplasties. Two matched cohorts had dual energy x-ray absorptiometry scans two years post-operatively using a modified validated densitometric analysis protocol, to assess peri-prosthetic bone mineral density. The knee that was not operated on was also scanned to enable the calculation of a relative bone mineral density difference. Oxford Knee and American Knee Society scores were comparable in the two cohorts.

Statistical analysis revealed no significant difference in absolute, or relative peri-prosthetic bone mineral density with respect to the method of fixation. However, the femoral peri-prosthetic bone mineral density and relative bone mineral density difference were significantly decreased, irrespective of the method of fixation, particularly in the anterior distal portion of the femur, with a mean reduction in relative bone mineral density difference of 27%.

There was no difference in clinical outcome between the cemented and cementless LCS total knee arthroplasty. However, both produce stress-shielding around the femoral implants. This leads us to question the use of more expensive cementless total knee components.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 479 - 483
1 Apr 2011
Chang C Lai K Yang C Lan S

Between April 2004 and July 2007, we performed 241 primary total knee replacements in 204 patients using the e.motion posterior cruciate-retaining, multidirectional mobile-bearing prosthesis. Of these, 100 were carried out using an image-free navigation system, and the remaining 141 with the conventional technique. We conducted a retrospective study from the prospectively collected data of these patients to assess the early results of this new mobile-bearing design.

At a mean follow-up of 49 months (32 to 71), 18 knees (7.5%) had mechanical complications of which 13 required revision. Three of these had a peri-prosthetic fracture, and were removed from the study. The indication for revision in the remaining ten was loosening of the femoral component in two, tibiofemoral dislocation in three, disassociation of the polyethylene liner in four, and a broken polyethyene liner in one. There were eight further mechanically unstable knees which presented with recurrent disassociation of the polyethylene liner. There was no significant difference in the incidence of mechanical instability between the navigation-assisted procedures (8 of 99, 8.1%) and the conventionally implanted knees (10 of 139, 7.2%).

In our view, the relatively high rate of mechanical complications and revision within 30 months precludes the further use of new design of knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 469 - 474
1 Apr 2009
Gulati A Pandit H Jenkins C Chau R Dodd CAF Murray DW

Varus malalignment after total knee replacement is associated with a poor outcome. Our aim was to determine whether the same was true for medial unicompartmental knee replacement (UKR). The anatomical leg alignment was measured prospectively using a long-arm goniometer in 160 knees with an Oxford UKR. Patients were then grouped according to their mechanical leg alignment as neutral (5° to 10° of valgus), mild varus (0° to 4° of valgus) and marked varus (> 0° of varus). The groups were compared at five years in terms of absolute and change in the Oxford Knee score, American Knee Society score and the incidence of radiolucent lines.

Post-operatively, 29 (18%) patients had mild varus and 13 (8%) had marked varus. The mean American Knee Society score worsened significantly (p < 0.001) with increasing varus. This difference disappeared if a three-point deduction for each degree of malalignment was removed. No other score deteriorated with increasing varus, and the frequency of occurrence of radiolucent lines was the same in each group.

We therefore conclude that after Oxford UKR, about 25% of patients have varus alignment, but that this does not compromise their clinical or radiological outcome. Following UKR the deductions for malalignment in the American Knee Society score are not justified.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1457 - 1461
1 Nov 2007
Han HS Kang S Yoon KS

We have examined the results obtained with 72 NexGen legacy posterior stabilised-flex fixed total knee replacements in 47 patients implanted by a single surgeon between March 2003 and September 2004.

Aseptic loosening of the femoral component was found in 27 (38%) of the replacements at a mean follow-up of 32 months (30 to 48) and 15 knees (21%) required revision at a mean of 23 months (11 to 45). We compared the radiologically-loose and revised knees with those which had remained well-fixed to identify the factors which had contributed to this high rate of aseptic loosening.

Post-operatively, the mean maximum flexion was 136° (110° to 140°) in the loosened group and 125° (95° to 140°) in the well-fixed group (independent t-test, p = 0.022). Squatting, kneeling, or sitting cross-legged could be achieved by 23 (85%) of the loosened knees, but only 22 (49%) of the well-fixed knees (chi-squared test, p = 0.001). The loosened femoral components were found to migrate into a more flexed position, but no migration was detected in the well-fixed group.

These implants allowed a high degree of flexion, but showed a marked rate of early loosening of the femoral component, which was associated with weight-bearing in maximum flexion.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 911 - 914
1 Jul 2007
Khan WS Nokes L Jones RK Johnson DS

We describe the influence of the angle of immobilisation during partial weight-bearing on the forces across the extensor mechanism of the knee. Gait analysis was performed on eight healthy male subjects with the right knee in an orthotic brace locked at 0°, 10°, 20° and 30°, with the brace unlocked and also without a brace. The ground reaction force, the angle of the knee and the net external flexion movement about the knee were measured and the extensor mechanism force was calculated.

The results showed a direct non-linear relationship between the angle of knee flexion and the extensor mechanism force. When a brace was applied, the lowest forces occurred when the brace was locked at 0°. At 30° the forces approached the failure strength of some fixation devices. We recommend that for potentially unstable injuries of the extensor mechanism, when mobilising with partial weight-bearing, the knee should be flexed at no more than 10°.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 50 - 56
1 Jan 2007
Yang KGA Raijmakers NJH Verbout AJ Dhert WJA Saris DBF

This study validates the short-form WOMAC function scale for assessment of conservative treatment of osteoarthritis of the knee. Data were collected before treatment and six and nine months later, from 100 patients with osteoarthritis of the knee to determine the validity, internal consistency, test-retest reliability, floor and ceiling effects, and responsiveness of the short-form WOMAC function scale. The scale showed high correlation with the traditional WOMAC and other measures. The internal consistency was good (Cronbach α: 0.88 to 0.95) and an excellent test-retest reliability was found (Lin’s concordance correlation coefficient (ρc): 0.85 to 0.94). The responsiveness was adequate and comparable to that of the traditional WOMAC (standardised response mean 0.56 to 0.44 and effect size 0.64 to 0.57) and appeared not to be significantly affected by floor or ceiling effects (0% and 7%, respectively).

The short-form WOMAC function scale is a valid, reliable and responsive alternative to the traditional WOMAC in the evaluation of patients with osteoarthritis of the knee managed conservatively. It is simple to use in daily practice and is therefore less of a burden for patients in clinical trials.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 937 - 939
1 Jul 2005
Richards JD Sanchez-Ballester J Jones RK Darke N Livingstone BN

In this cross-over study, we evaluated two types of knee brace commonly used in the conservative treatment of osteoarthritis of the medial compartment. Twelve patients confirmed radiologically as having unilateral osteoarthritis of the medial compartment (Larsen grade 2 to grade 4) were studied. Treatment with a simple hinged brace was compared with that using a valgus corrective brace. Knee kinematics, ground reaction forces, pain and function were assessed during walking and the Hospital for Special Surgery scores were also determined.

Significant improvements in pain, function, and loading and propulsive forces were seen with the valgus brace. Treatment with a simple brace showed only significant improvements in loading forces. Our findings suggest that although both braces improved confidence and function during gait, the valgus brace showed greater benefit.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 188 - 197
1 Feb 2006
Cobb J Henckel J Gomes P Harris S Jakopec M Rodriguez F Barrett A Davies B

We performed a prospective, randomised controlled trial of unicompartmental knee arthroplasty comparing the performance of the Acrobot system with conventional surgery. A total of 27 patients (28 knees) awaiting unicompartmental knee arthroplasty were randomly allocated to have the operation performed conventionally or with the assistance of the Acrobot. The primary outcome measurement was the angle of tibiofemoral alignment in the coronal plane, measured by CT. Other secondary parameters were evaluated and are reported.

All of the Acrobot group had tibiofemoral alignment in the coronal plane within 2° of the planned position, while only 40% of the conventional group achieved this level of accuracy. While the operations took longer, no adverse effects were noted, and there was a trend towards improvement in performance with increasing accuracy based on the Western Ontario and McMaster Universities Osteoarthritis Index and American Knee Society scores at six weeks and three months. The Acrobot device allows the surgeon to reproduce a pre-operative plan more reliably than is possible using conventional techniques which may have clinical advantages.