Penetration of the dorsal screw when treating
distal radius fractures with volar locking plates is an avoidable complication
that causes lesions of the extensor tendon in between 2% and 6%
of patients. We examined axial fluoroscopic views of the distal
end of the radius to observe small amounts of dorsal screw penetration,
and determined the
The aim of this retrospective study was to evaluate the rate of conversion to surgical release after a steroid injection in patients with a trigger finger, and to analyze which patient- and trigger finger-related factors affect the outcome of an injection. The medical records of 500 patients (754 fingers) treated for one or more trigger fingers with a steroid injection or with surgical release, between 1 January 2016 and 1 April 2020 with a follow-up of 12 months, were analyzed. Conversion to surgical release was recorded as an unsuccessful treatment after an injection. The effect of patient- and trigger finger-related characteristics on the outcome of an injection was assessed using stepwise manual backward multivariate logistic regression analysis.Aims
Methods
This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized bone grafting, and percutaneous fixation. This was a retrospective analysis of 20 patients. All cases were delayed presentations (n = 15) or failed nonoperatively managed scaphoid fractures (n = 5). Surgery was performed at a mean duration of 27 months (7 to 120) following injury with arthroscopic debridement and arthroscopic iliac crest autograft. Fracture fixation was performed percutaneously with Kirschner (K)-wires in 12 wrists, a headless screw in six, and a combination of a headless screw and single K-wire in two. Clinical outcomes were assessed using grip strength, patient-reported outcome measures, and wrist range of motion (ROM) measurements.Aims
Methods
The aims of this study were to assess the efficacy
of a newly designed radiological technique (the radial groove view)
for the detection of protrusion of screws in the groove for the
extensor pollicis longus tendon (EPL) during plating of distal radial
fractures. We also aimed to determine the optimum position of the
forearm to obtain this view. We initially analysed the anatomy of
the EPL groove by performing three-dimensional CT on 51 normal forearms.
The mean horizontal angle of the groove was 17.8° (14° to 23°).
We found that the
The aim of this study was to assess and compare active rotation of the forearm in normal subjects after the application of a short-arm cast (SAC) in the semisupination position and a long-arm cast (LAC) in the neutral position. A clinical study was also conducted to compare the functional outcomes of using a SAC in the semisupination position with those of using a LAC in the neutral position in patients who underwent arthroscopic triangular fibrocartilage complex (TFCC) foveal repair. A total of 40 healthy right-handed volunteers were recruited. Active pronation and supination of the forearm were measured in each subject using a goniometer. In the retrospective clinical study, 40 patients who underwent arthroscopic foveal repair were included. The wrist was immobilized postoperatively using a SAC in the semisupination position (approximately 45°) in 16 patients and a LAC in 24. Clinical outcomes were assessed using grip strength and patient-reported outcomes. The degree of disability caused by cast immobilization was also evaluated when the cast was removed.Aims
Methods
The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a volar locking plate for a distal radial fracture. This study was a retrospective review of a prospective database of 155 patients who underwent internal fixation with a volar locking plate for a distal radial fracture between August 2014 and April 2017. Data which were collected included postoperative PROMs (Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH) and Patient-Rated Wrist Evaluation (PRWE)), and SANE scores at one month (n = 153), two months (n = 155), three months (n = 144), six months (n = 128), and one year (n = 73) after operation. Patients with incomplete data were excluded from this study. Correlation and agreement between PROMs and SANE scores were evaluated. Subgroup analyses were carried out to identify correlations according to variables such as age, the length of follow-up, and subcategories of the PRWE score.Aims
Methods
We report a new surgical technique for the treatment
of traumatic dislocation of the carpometacarpal (CMC) joint of the
thumb. This is a tenodesis which uses part of the flexor carpi radialis. Between January 2010 and August 2013, 13 patients with traumatic
instability of the CMC joint of the thumb were treated using this
technique. The mean time interval between injury and ligament reconstruction
was 13 days (0 to 42). The mean age of the patients at surgery was
38 years: all were male. At a mean final follow-up of 26 months (24 to 29), no patient
experienced any residual instability. The mean total palmar abduction
of the CMC joint of the thumb was 61° and the mean radial abduction
65° The mean measurements for the uninjured hand were 66° (60° to
73°) and 68° (60° to 75°), respectively. The mean Kapandji thumb
opposition score was 8.5° (8° to 9°). The mean pinch and grip strengths
of the hand were 6.7 kg (3.4 to 8.2) and 40 kg (25 to 49), respectively.
The mean Disabilities of the Arm, Shoulder, and Hand questionnaire
score was 3 (1 to 6). Based on the Smith and Cooney score, we obtained
a mean score of 85 (75 to 95), which included four excellent, seven
good, and two fair results. Our technique offers an alternative method of treating traumatic
dislocation of the CMC joint of the thumb: it produces a stable
joint and acceptable hand function. Cite this article: