We present a retrospective review of a single-surgeon series of 30 consecutive lengthenings in 27 patients with
1. Twenty patients with
Seventy patients with 91
We have reviewed the results in 37 patients with unilateral
Forty-three patients with unilateral
We review the results of a modified quadricepsplasty in five children who developed stiffness of the knee after femoral lengthening for
1. Nineteen patients with congenital shortening of the femur without associated coxa vara have been examined and discussed. 2. The diagnosis is made on finding a short, bulky thigh, held in lateral rotation. The radiographs commonly show no abnormality apart from shortening, but delay in ossification of the head of the femur, with lateral bowing and cortical sclerosis of the shaft, are occasionally present. The overall shortening of the limb seldom exceeds three inches. 3. The place of various surgical procedures to control limb length is briefly discussed.
We describe 11 children with fibular hypoplasia and three- or four-ray feet, two bilaterally. This deformity is a less severe form of the better known
We performed intraoperative arthrography of the knee in 12 children with
We performed one-stage lengthening using intercalary autogenous bone graft in 34 metatarsals and seven proximal phalanges in 21 patients with
Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences. A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages.Aims
Methods
Axial forces were measured during limb lengthening in a series of ten patients with varying pathologies in order to assess the mechanical characteristics of the distracted tissues and the levels of axial force to which soft tissues are subjected during leg lengthening. The pattern of force was found to vary according to the underlying pathology. For post-traumatic shortening in adults both the peak and the resting forces rose steadily during lengthening reaching maximum forces of the order of 300 N. Patients with
Three amputated legs with tibial dysplasia were studied by radiography, arteriography and anatomical dissection. The radiographic appearances were the same as the Type 1b tibial dysplasia described by Jones, Barnes and Lloyd-Roberts (1978) in that the tibiae were absent but the lower femoral epiphyses were normal. However, our anatomical findings differed from those of Jones et al. since no bony or cartilaginous anlage of the proximal tibia was found in any of the three legs. The pattern of vascular anomaly was identical in the three legs and similar to the findings of Hootnick et al. (1980) in
The Precice intramedullary limb-lengthening system has demonstrated significant benefits over external fixation lengthening methods, leading to a paradigm shift in limb lengthening. This study compares outcomes following antegrade and retrograde femoral lengthening in both adolescent and adult patients. A retrospective review of prospectively collected data was undertaken of a consecutive series of 107 femoral lengthening operations in 92 patients. In total, 73 antegrade nails and 34 retrograde nails were inserted. Outcome was assessed by the regenerate healing index (HI), hip and knee range of movement (ROM), and the presence of any complications.Aims
Patients and Methods
Computer hexapod assisted orthopaedic surgery (CHAOS), is a method
to achieve the intra-operative correction of long bone deformities
using a hexapod external fixator before definitive internal fixation
with minimally invasive stabilisation techniques. The aims of this study were to determine the reliability of this
method in a consecutive case series of patients undergoing femoral
deformity correction, with a minimum six-month follow-up, to assess
the complications and to define the ideal group of patients for
whom this treatment is appropriate. The medical records and radiographs of all patients who underwent
CHAOS for femoral deformity at our institution between 2005 and
2011 were retrospectively reviewed. Records were available for all
55 consecutive procedures undertaken in 49 patients with a mean
age of 35.6 years (10.9 to 75.3) at the time of surgery.Aims
Patients and Methods
This retrospective study compared post-operative
epidural analgesia (E), continuous peripheral nerve blocks (CPNB) and
morphine infusion (M) in 68 children undergoing limb reconstruction
with circular frames. The data collected included episodes of severe
pain, post-operative duration of analgesia, requirement for top-up
analgesia, number of osteotomies, side effects and complications.
There was a significant difference between the number of episodes
of severe pain in patients receiving a morphine infusion and those
receiving epidurals or CPNB (M
The June 2014 Children’s orthopaedics Roundup360 looks at: plaster wedging in paediatric forearm fractures; the medial approach for DDH; Ponseti – but not as he knew it?; Salter osteotomy more accurate than Pemberton in DDH; is the open paediatric fracture an emergency?; bang up-to-date with femoral external fixation; indomethacin, heterotopic ossification and cerebral palsy hips; lengthening nails for congenital femoral deformities, and is MRI the answer to imaging of the physis?
The December 2013 Children’s orthopaedics Roundup360 looks at: Long term-changes in hip morphology following osteotomy; Arthrogrypotic wrist contractures are surgically amenable; Paediatric femoral lengthening over a nail; Current management of paediatric supracondylar fractures; MRI perfusion index predictive of Perthes’ progression; Abduction bracing effective in residual acetabular deformity; Hurler syndrome in the spotlight; and the Pavlik works for femoral fractures too!
Van Nes rotationplasty may be used for patients
with congenital proximal focal femoral deficiency (PFFD). The lower
limb is rotated to use the ankle and foot as a functional knee joint
within a prosthesis. A small series of cases was investigated to
determine the long-term outcome. At a mean of 21.5 years (11 to
45) after their rotationplasty, a total of 12 prosthetic patients
completed the Short-Form (SF)-36, Faces Pain Scale-Revised, Harris
hip score, Oswestry back pain score and Prosthetic Evaluation Questionnaires,
as did 12 age- and gender-matched normal control participants. A
physical examination and gait analysis, computerised dynamic posturography
(CDP), and timed ‘Up &
Go’ testing was also completed. Wilcoxon
Signed rank test was used to compare each PFFD patient with a matched
control participant with false discovery rate of 5%. There were no differences between the groups in overall health
and well-being on the SF-36. Significant differences were seen in
gait parameters in the PFFD group. Using CDP, the PFFD group had
reduced symmetry in stance, and reduced end point and maximum excursions. Patients who had undergone Van Nes rotationplasty had a high
level of function and quality of life at long-term follow-up, but
presented with significant differences in gait and posture compared
with the control group. Cite this article:
This study evaluated the effect of limb lengthening
on longitudinal growth in patients with achondroplasia. Growth of
the lower extremity was assessed retrospectively by serial radiographs
in 35 skeletally immature patients with achondroplasia who underwent
bilateral limb lengthening (Group 1), and in 12 skeletally immature
patients with achondroplasia who did not (Group 2). In Group 1,
23 patients underwent only tibial lengthening (Group 1a) and 12 patients
underwent tibial and femoral lengthening sequentially (Group 1b). The mean lengthening in the tibia was 9.2 cm (59.5%) in Group
1a, and 9.0 cm (58.2%) in the tibia and 10.2 cm (54.3%) in the femur
in Group 1b. The mean follow-up was 9.3 years (8.6 to 10.3). The
final mean total length of lower extremity in Group 1a was 526.6
mm (501.3 to 552.9) at the time of skeletal maturity and 610.1 mm
(577.6 to 638.6) in Group 1b, compared with 457.0 mm (411.7 to 502.3)
in Group 2. However, the mean actual length, representing the length
solely grown from the physis without the length of distraction,
showed that there was a significant disturbance of growth after
limb lengthening. In Group 1a, a mean decrease of 22.4 mm (21.3
to 23.1) (4.9%) was observed in the actual limb length when compared
with Group 2, and a greater mean decrease of 38.9 mm (37.2 to 40.8)
(8.5%) was observed in Group 1b when compared with Group 2 at skeletal
maturity. In Group 1, the mean actual limb length was 16.5 mm (15.8 to
17.2) (3.6%) shorter in Group 1b when compared with Group 1a at
the time of skeletal maturity. Premature physeal closure was seen
mostly in the proximal tibia and the distal femur with relative
preservation of proximal femur and distal tibia. We suggest that significant disturbance of growth can occur after
extensive limb lengthening in patients with achondroplasia, and
therefore, this should be included in pre-operative counselling
of these patients and their parents.
We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties. Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%).
We carried out a retrospective study to assess the clinical results of lengthening the fourth metatarsal in brachymetatarsia in 153 feet of 106 patients (100 female, six males) using three different surgical techniques. In one group lengthening was performed by one-stage intercalary bone grafting secured by an intramedullary Kirschner-wire (45 feet, 35 patients). In the second group lengthening was obtained gradually using a mini-external fixator after performing an osteotomy with a saw (59 feet, 39 patients) and in the third group lengthening was achieved in a gradual manner using a mini-external fixator after undertaking an osteotomy using osteotome through pre-drilled holes (49 feet, 32 patients). The mean age of the patients was 26.3 years (13 to 48). Pre-operatively, the fourth ray of the bone-graft group was longer than that of other two groups (p <
0.000). The clinical outcome was compared in the three groups. The mean follow-up was 22 months (7 to 55). At final follow-up, the mean lengthening in the bone-graft group was 13.9 mm (3.5 to 23.0, 27.1%) which was less than that obtained in the saw group with a mean of 17.8 mm (7.0 to 33.0, 29.9%) and in the pre-drilled osteotome group with a mean of 16.8 mm (6.5 to 28.0, 29.4%, p = 0.001). However, the mean time required for retention of the fixation in the bone-graft group was the shortest of the three groups. Patients were dissatisfied with the result for five feet (11.1%) in the bone-graft group, eight (13.6%) in the saw group and none in the pre-drilled osteotomy group (p <
0.000). The saw group included eight feet with failure of bone formation after surgery. Additional operations were performed in 20 feet because of stiffness (n = 7, all groups), failure of bone formation (n = 4, saw group), skin maceration (n = 4, bone-graft group), malunion (n = 4, bone-graft and saw groups) and breakage of the external fixator (n = 1, saw group). We conclude that the gradual lengthening by distraction osteogenesis after osteotomy using an osteotome produces the most reliable results for the treatment of fourth brachymetatarsia.