Penetration of the dorsal screw when treating
distal radius fractures with volar locking plates is an avoidable complication
that causes lesions of the extensor tendon in between 2% and 6%
of patients. We examined axial fluoroscopic views of the distal
end of the radius to observe small amounts of dorsal screw penetration,
and determined the ideal angle of inclination of the x-ray beam
to the forearm when making this radiological view. Six volar locking plates were inserted at the wrists of cadavers.
The actual screw length was measured under direct vision through
a dorsal approach to the distal radius. Axial radiographs were performed
for different angles of inclination of the forearm at the elbow. Comparing axial radiological measurements and real screw length,
a statistically significant correlation could be demonstrated at
an angle of inclination between 5° and 20°. The ideal angle of inclination
required to minimise the risk of implanting over-long screws in
a dorsal horizon radiological view is 15°. Cite this article:
We identified 11 women with a mean age of 74 years (65 to 81) who sustained comminuted distal radial and ulnar fractures and were treated by volar plating and slight shortening of the radius combined with a primary Sauvé-Kapandji procedure. At a mean of 46 months (16 to 58), union of distal radial fractures and arthrodesis of the distal radioulnar joint was seen in all patients. The mean shortening of the radius was 12 mm (5 to 18) compared to the contralateral side. Flexion and extension of the wrist was a mean of 54° and 50°, respectively, and the mean pronation and supination of the forearm was 82° and 86°, respectively. The final mean disabilities of the arm, shoulder and hand score was 26 points. According to the Green and O’Brien rating system, eight patients had an excellent, two a good and one a fair result. The good clinical and radiological results, and the minor complications without the need for further operations related to late ulnar-sided wrist pain, justify this procedure in the elderly patient.
We report the use of a free vascularised iliac bone graft in the treatment of 21 patients (19 men and 2 women) with an avascular nonunion of the scaphoid in which conventional bone grafting had previously failed. The mean age of the patients was 32 years (23 to 46) and the dominant wrist was affected in 14. The mean interval from fracture to the vascularised bone grafting was 39 months (9 to 62). Pre-operative MRI showed no contrast enhancement in the proximal fragment in any patient. Fracture union was assessed radiologically or with CT scans if the radiological appearances were inconclusive. At a mean follow-up of 5.6 years (2 to 11) union was obtained in 16 patients. The remaining five patients with a persistent nonunion continued to experience pain, reduced grip strength and limited range of wrist movement. In the successfully treated patients the grip strength and range of movement did not recover to match the uninjured side. Prevention of progressive carpal collapse, the absence of donor site morbidity, good subjective results and pain relief, justifies this procedure in the treatment of recalcitrant nonunion of the scaphoid.