The aim was to assess whether robotic-assisted total knee arthroplasty (rTKA) had greater knee-specific outcomes, improved fulfilment of expectations, health-related quality of life (HRQoL), and patient satisfaction when compared with manual TKA (mTKA). A randomized controlled trial was undertaken (May 2019 to December 2021), and patients were allocated to either mTKA or rTKA. A total of 100 patients were randomized, 50 to each group, of whom 43 rTKA and 38 mTKA patients were available for review at 12 months following surgery. There were no statistically significant preoperative differences between the groups. The minimal clinically important difference in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain score was defined as 7.5 points.Aims
Methods
Achievement of accurate microbiological diagnosis prior to revision is key to reducing the high rates of persistent infection after revision knee surgery. The effect of change in the microorganism between the first- and second-stage revision of total knee arthroplasty for periprosthetic joint infection (PJI) on the success of management is not clear. A two-centre retrospective cohort study was conducted to review the outcome of patients who have undergone two-stage revision for treatment of knee arthroplasty PJI, focusing specifically on isolated micro-organisms at both the first- and second-stage procedure. Patient demographics, medical, and orthopaedic history data, including postoperative outcomes and subsequent treatment, were obtained from the electronic records and medical notes.Aims
Methods
The primary aim was to assess whether robotic total knee arthroplasty (rTKA) had a greater early knee-specific outcome when compared to manual TKA (mTKA). Secondary aims were to assess whether rTKA was associated with improved expectation fulfilment, health-related quality of life (HRQoL), and patient satisfaction when compared to mTKA. A randomized controlled trial was undertaken, and patients were randomized to either mTKA or rTKA. The primary objective was functional improvement at six months. Overall, 100 patients were randomized, 50 to each group, of whom 46 rTKA and 41 mTKA patients were available for review at six months following surgery. There were no differences between the two groups.Aims
Methods
The aim of this study was to identify variables associated with time to revision, demographic details associated with revision indication, and type of prosthesis employed, and to describe the survival of hinge knee arthroplasty (HKA) when used for first-time knee revision surgery and factors that were associated with re-revision. Patient demographic details, BMI, American Society of Anesthesiologists (ASA) grade, indication for revision, surgical approach, surgeon grade, implant type (fixed and rotating), time of revision from primary implantation, and re-revision if undertaken were obtained from the National Joint Registry data for England, Wales, Northern Ireland, and the Isle of Man over an 18-year period (2003 to 2021).Aims
Methods
The primary aim of this study was to assess whether the postoperative Oxford Knee Score (OKS) demonstrated a ceiling effect at one and/or two years after total knee arthroplasty (TKA). The secondary aim was to identify preoperative independent predictors for patients that achieved a ceiling score after TKA. A retrospective cohort of 5,857 patients undergoing a primary TKA were identified from an established arthroplasty database. Patient demographics, body mass index (BMI), OKS, and EuroQoL five-dimension (EQ-5D) general health scores were collected preoperatively and at one and two years postoperatively. Logistic regression analysis was used to identify independent preoperative predictors of patients achieving postoperative ceiling scores. Receiver operating characteristic curve was used to identify a preoperative OKS that predicted a postoperative ceiling score.Aims
Methods
Stiffness is a common complication after total knee arthroplasty (TKA). Pathogenesis is not understood, treatment options are limited, and diagnosis is challenging. The aim of this study was to investigate if MRI can be used to visualize intra-articular scarring in patients with stiff, painful knee arthroplasties. Well-functioning primary TKAs (n = 11), failed non-fibrotic TKAs (n = 5), and patients with a clinical diagnosis of fibrosisAims
Methods
The primary aim of this study was to assess whether pain in the contralateral knee had a clinically significant influence on the outcome of total knee arthroplasty (TKA) according to the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. Secondary aims were to: describe the prevalence of contralateral knee pain; identify if it clinically improves after TKA; and assess whether contralateral knee pain independently influences patient satisfaction with their TKA. A retrospective cohort of 3,178 primary TKA patients were identified from an arthroplasty database. Patient characteristics, comorbidities, and WOMAC scores were collected preoperatively and one year postoperatively for the index knee. In addition, WOMAC pain scores were also collected for the contralateral knee. Overall patient satisfaction was assessed at one year. Preoperative contralateral knee pain was defined according to the WOMAC score: minimal (> 78 points), mild (59 to 78), moderate (44 to 58), and severe (< 44). Multivariate regression analysis was used to adjust for confounding.Aims
Methods
The primary aim of the study was to perform an analysis to identify the cost per quality-adjusted life-year (QALY) of robot-assisted unicompartmental knee arthroplasty (rUKA) relative to manual total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) for patients with isolated medial compartment osteoarthritis (OA) of the knee. Secondary aims were to assess how case volume and length of hospital stay influenced the relative cost per QALY. A Markov decision analysis was performed, using known parameters for costs, outcomes, implant survival, and mortality, to assess the cost-effectiveness of rUKA relative to manual TKA and UKA for patients with isolated medial compartment OA of the knee with a mean age of 65 years. The influence of case volume and shorter hospital stay were assessed.Aims
Patients and Methods
The primary aim of this study was to assess the rate of patient
satisfaction one year after total knee arthroplasty (TKA) according
to the focus of the question asked. The secondary aims were to identify
independent predictors of patient satisfaction according to the
focus of the question. A retrospective cohort of 2521 patients undergoing a primary
unilateral TKA were identified from an established regional arthroplasty
database. Patient demographics, comorbidities, Western Ontario and
McMaster Universities Osteoarthritis Index (WOMAC) and 12-Item Short-Form
Health Survey (SF-12) scores were collected preoperatively and one
year postoperatively. Patient satisfaction was assessed using four
questions, which focused on overall outcome, activity, work, and
pain. Logistic regression analysis was used to identify independent
preoperative predictors of increased stiffness when adjusting for
confounding variables.Aims
Patients and Methods
The primary aim of this study was to assess whether patient satisfaction
one year after total knee arthroplasty (TKA) changed with longer
follow-up. The secondary aims were to identify predictors of satisfaction
at one year, persistence of patient dissatisfaction, and late onset
dissatisfaction in patients that were originally satisfied at one year. A retrospective cohort consisting of 1369 patients undergoing
a primary TKA for osteoarthritis that had not undergone revision
were identified from an established arthroplasty database. Patient
demographics, comorbidities, Western Ontario and McMaster Universities
Osteoarthritis Index (WOMAC) scores, and Short Form 12 (SF-12) questionnaire
scores were collected preoperatively, and one and five years postoperatively.
In addition, patient satisfaction was assessed at one and five years
postoperatively. Logistic regression analysis was used to identify
independent predictors of satisfaction at one and five years.Aims
Patients and Methods
The aim of this consensus was to develop a definition of post-operative
fibrosis of the knee. An international panel of experts took part in a formal consensus
process composed of a discussion phase and three Delphi rounds.Aims
Patients and Methods
The aim of this study was to compare the maximum
laxity conferred by the cruciate-retaining (CR) and posterior-stabilised
(PS) Triathlon single-radius total knee arthroplasty (TKA) for anterior
drawer, varus–valgus opening and rotation in eight cadaver knees
through a defined arc of flexion (0º to 110º). The null hypothesis
was that the limits of laxity of CR- and PS-TKAs are not significantly
different. The investigation was undertaken in eight loaded cadaver knees
undergoing subjective stress testing using a measurement rig. Firstly
the native knee was tested prior to preparation for CR-TKA and subsequently
for PS-TKA implantation. Surgical navigation was used to track maximal
displacements/rotations at 0º, 30º, 60º, 90º and 110° of flexion.
Mixed-effects modelling was used to define the behaviour of the
TKAs. The laxity measured for the CR- and PS-TKAs revealed no statistically
significant differences over the studied flexion arc for the two
versions of TKA. Compared with the native knee both TKAs exhibited
slightly increased anterior drawer and decreased varus-valgus and
internal-external roational laxities. We believe further study is required
to define the clinical states for which the additional constraint
offered by a PS-TKA implant may be beneficial. Cite this article:
Pre-operative variables are increasingly being
used to determine eligibility for total knee replacement (TKR).
This study was undertaken to evaluate the relationships, interactions
and predictive capacity of variables available pre- and post-operatively
on patient satisfaction following TKR. Using nationally collected
patient reported outcome measures and data from the National Joint
Registry for England and Wales, we identified
22 798 patients who underwent TKR for osteoarthritis between August
2008 and September 2010. The ability of specific covariates to predict
satisfaction was assessed using ordinal logistic regression and
structural equational modelling. Only 4959 (22%) of 22 278 patients
rated the results of their TKR as ‘excellent’, despite the majority
(71%, n = 15 882) perceiving their knee symptoms to be much improved.
The strongest predictors of satisfaction were post-operative variables.
Satisfaction was significantly and positively related to the perception
of symptom improvement (operative success) and the post-operative
EuroQol-5D score. While also significant within the models pre-operative
variables were less important and had a minimal influence upon post-operative
satisfaction. The most robust predictions of satisfaction occurred
only when both pre- and post-operative variables were considered
together. These findings question the appropriateness of restricting
access to care based on arbitrary pre-operative thresholds as these
factors have little bearing on post-operative satisfaction. Cite this article:
Current analysis of unicondylar knee replacements
(UKRs) by national registries is based on the pooled results of medial
and lateral implants. Consequently, little is known about the differential
performance of medial and lateral replacements and the influence
of each implant type within these pooled analyses. Using data from
the National Joint Registry for England and Wales (NJR) we aimed
to determine the proportion of UKRs implanted on the lateral side
of the knee, and their survival and reason for failure compared
with medial UKRs. By combining information on the side of operation
with component details held on the NJR, we were able to determine
implant laterality (medial
Patient-reported outcome measures (PROMs) are
increasingly being used to assess functional outcome and patient satisfaction.
They provide a framework for comparisons between surgical units,
and individual surgeons for benchmarking and financial remuneration.
Better performance may bring the reward of more customers as patients and
commissioners seek out high performers for their elective procedures.
Using National Joint Registry (NJR) data linked to PROMs we identified
22 691 primary total knee replacements (TKRs) undertaken for osteoarthritis
in England and Wales between August 2008 and February 2011, and
identified the surgical factors that influenced the improvements
in the Oxford knee score (OKS) and EuroQol-5D (EQ-5D) assessment
using multiple regression analysis. After correction for patient
factors the only surgical factors that influenced PROMs were implant
brand and hospital type (both p <
0.001). However, the effects
of surgical factors upon the PROMs were modest compared with patient
factors. For both the OKS and the EQ-5D the most important factors
influencing the improvement in PROMs were the corresponding pre-operative
score and the patient’s general health status. Despite having only
a small effect on PROMs, this study has shown that both implant
brand and hospital type do influence reported subjective functional
scores following TKR. In the current climate of financial austerity,
proposed performance-based remuneration and wider patient choice,
it would seem unwise to ignore these effects and the influence of
a range of additional patient factors.
Following arthroplasty of the knee, the patient’s
perception of improvement in symptoms is fundamental to the assessment
of outcome. Better clinical outcome may offset the inferior survival
observed for some types of implant. By examining linked National
Joint Registry (NJR) and patient-reported outcome measures (PROMs)
data, we aimed to compare PROMs collected at a minimum of six months
post-operatively for total (TKR: n = 23 393) and unicondylar knee
replacements (UKR: n = 505). Improvements in knee-specific (Oxford
knee score, OKS) and generic (EuroQol, EQ-5D) scores were compared
and adjusted for case-mix differences using multiple regression.
Whereas the improvements in the OKS and EQ-5D were significantly
greater for TKR than for UKR, once adjustments were made for case-mix
differences and pre-operative score, the improvements in the two
scores were not significantly different. The adjusted mean differences
in the improvement of OKS and EQ-5D were 0.0 (95% confidence interval (CI)
-0.9 to 0.9; p = 0.96) and 0.009 (95% CI -0.034 to 0.015; p = 0.37),
respectively. We found no difference in the improvement of either knee-specific
or general health outcomes between TKR and UKR in a large cohort
of registry patients. With concerns about significantly higher revision
rates for UKR observed in worldwide registries, we question the
widespread use of an arthroplasty that does not confer a significant
benefit in clinical outcome.
We compared thromboembolic events, major haemorrhage
and death after knee replacement in patients receiving either aspirin
or low-molecular-weight heparin (LMWH). Data from the National Joint
Registry for England and Wales were linked to an administrative
database of hospital admissions in the English National Health Service.
A total of 156 798 patients between April 2003 and September 2008
were included and followed for 90 days. Multivariable risk modelling
was used to estimate odds ratios adjusted for baseline risk factors
(AOR). An AOR <
1 indicates that risk rates are lower with LMWH
than with aspirin. In all, 36 159 patients (23.1%) were prescribed aspirin
and 120 639 patients (76.9%) were prescribed LMWH. We found no statistically
significant differences between the aspirin and LMWH groups in the
rate of pulmonary embolism (0.49% These results should be considered when the existing guidelines
for thromboprophylaxis after knee replacement are reviewed.
The role of modular tibial implants in total knee replacement is not fully defined. We performed a prospective randomised controlled clinical trial using radiostereophotogrammetric analysis to compare the performance of an all-polyethylene tibia with a metal-backed cruciate-retaining condylar design, PFC-∑ total knee replacement for up to 24 months. There were 51 patients who were randomised into two treatment groups. There were 10 subsequent withdrawals, leaving 21 all-polyethylene and 20 metal-backed tibial implants. No patient was lost to follow-up. There were no significant demographic differences between the groups. At two years one metal-backed implant showed migration >
1 mm, but no polyethylene implant reached this level. There was a significant increase in the SF-12 and Oxford knee scores after operation in both groups. In an uncomplicated primary total knee replacement the all-polyethylene PFC-∑ tibial prosthesis showed no statistical difference in migration from that of the metal-backed counterpart. There was no difference in the clinical results as assessed by the SF-12, the Oxford knee score, alignment or range of movement at 24 months, although these assessment measures were not statistically powered in this study.
We carried out 60 revision procedures for failed porous coated anatomic total knee replacements in 54 patients, which were divided into two groups. The 14 knees in group I had a well-fixed femoral component at surgery which was retained, and in the 46 knees in group II both tibial and femoral components were loose and were revised using a variety of implants. Our review comprised clinical and radiological assessment. A total of 13 knees required a second revision. Six (42%) in group I failed very early (mean 2.1 years) when compared with seven (15%) in group II (mean 6.8 years). Failure was due to wear of the polyethylene insert by the abraded, retained femoral component (crude odds ratio 4.07; 95% CI 1.07 to 15.5). We recommend a complete change of primary bearing surfaces at the time of revision of an uncemented total knee replacement in order to prevent early wear of polyethylene.
A total of 90 patients with an isolated rupture of the anterior cruciate ligament (ACL) had a reconstruction using the ipsilateral patellar tendon secured with round-headed cannulated interference screws. Annual review for five years showed three failures of the graft (two traumatic and one atraumatic); none occurred after two years. Ten patients sustained a rupture of the contralateral ACL. At five years, 69% of those with surviving grafts continued to participate in moderate to strenuous activity. Using the International Knee Documentation Committee assessment, 90% reported their knee as being normal or nearly normal and had a median Lysholm knee score of 96 (64 to 100). Most patients (98%) had a pivot shift of grade 0 with the remaining 2% being grade 1; 90% of the group had a Lachman test of grade 0. The incidence of subsequent meniscectomy was similar in the reconstructed joint to that in the contralateral knee. Radiological examination was normal in 63 of 65 patients. Our study supports the view that reconstruction of the ACL is a reliable technique allowing full rehabilitation of the previously injured knee. In the presence of normal menisci there is a low incidence of osteoarthritic change despite continued participation in sporting activity.