Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1697 - 1702
1 Dec 2020
Schormans PMJ Kooijman MA Ten Bosch JA Poeze M Hannemann PFW

Aims. Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion. Methods. Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed. Results. A total of 49 patients with a mean age of 31 years (16 to 74) and a mean duration of nonunion of 3.6 years (0.4 to 16) were included. Postoperatively, the nonunion healed in 47 patients (96%) as shown on CT scans. The mean time to union was 4.2 months (3 to 12). Due to impingement of the plate on the volar rim of the radius and functional limitation, the hardware was removed in 18 patients. At a median follow-up of 38 months in 34 patients, the mean active range of motion (ROM) improved significantly from 89° to 124° (SD 44°; p = 0.003). The mean grip strength improved significantly from 52% to 79% (SD 28%; p < 0.001) of the contralateral side. The mean PRWHE score improved significantly from 66 to 17 points (SD 25; p < 0.001). Conclusion. Locking plate fixation supplemented with autologous cancellous bone grafting is a successful form of treatment for scaphoid nonunion. Functional outcomes improve with the passage of time, and mid-term results are excellent with a significant improvement in ROM, grip strength, and functional outcome as measured by the PRWHE. Cite this article: Bone Joint J 2020;102-B(12):1697–1702


Aims. The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a volar locking plate for a distal radial fracture. Methods. This study was a retrospective review of a prospective database of 155 patients who underwent internal fixation with a volar locking plate for a distal radial fracture between August 2014 and April 2017. Data which were collected included postoperative PROMs (Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH) and Patient-Rated Wrist Evaluation (PRWE)), and SANE scores at one month (n = 153), two months (n = 155), three months (n = 144), six months (n = 128), and one year (n = 73) after operation. Patients with incomplete data were excluded from this study. Correlation and agreement between PROMs and SANE scores were evaluated. Subgroup analyses were carried out to identify correlations according to variables such as age, the length of follow-up, and subcategories of the PRWE score. Results. The Pearson correlation coefficient (r) between PROMs and SANE scores was -0.76 (p < 0.001) for DASH and -0.72 (p < 0.001) for PRWE, respectively. Limits of agreement between PROMs and ‘100-SANE’ scores were met for at least 93% of the data points. In subgroup analysis, there were significant negative correlations between PROMs and SANE scores for all age groups and for follow-up of more than six months. The correlation coefficient between PRWE subcategories and SANE score was -0.67 (p < 0.001) for PRWE pain score and -0.69 (p < 0.001) for PRWE function score, respectively. Conclusion. We found a significant correlation between postoperative SANE and PROMs in patients treated with a volar locking plate for a distal radial fracture. The SANE score is thus a reliable indicator of outcome for patients who undergo surgical treatment for a radial fracture. Cite this article: Bone Joint J 2020;102-B(6):744–748


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1329 - 1333
1 Dec 2022
Renfree KJ

This annotation reviews current concepts on the three most common surgical approaches used for proximal interphalangeal joint arthroplasty: dorsal, volar, and lateral. Advantages and disadvantages of each are highlighted, and the outcomes are discussed.

Cite this article: Bone Joint J 2022;104-B(12):1329–1333.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 957 - 962
1 Jul 2015
Yamazaki H Uchiyama S Komatsu M Hashimoto S Kobayashi Y Sakurai T Kato H

There is no consensus on the benefit of arthroscopically assisted reduction of the articular surface combined with fixation using a volar locking plate for the treatment of intra-articular distal radial fractures. In this study we compared the functional and radiographic outcomes of fluoroscopically and arthroscopically guided reduction of these fractures. Between February 2009 and May 2013, 74 patients with unilateral unstable intra-articular distal radial fractures were randomised equally into the two groups for treatment. The mean age of these 74 patients was 64 years (24 to 92). We compared functional outcomes including active range of movement of the wrist, grip strength and Disabilities of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic outcomes that included gap, step, radial inclination, volar angulation and ulnar variance. . There were no significant differences between the techniques with regard to functional outcomes or radiographic parameters. The mean gap and step in the fluoroscopic and arthroscopic groups were comparable at 0.9 mm (standard deviation. (sd). 0.7) and 0.7 mm (. sd. 0.7) and 0.6 mm (. sd. 0.6) and 0.4 mm (. sd. 0.5), respectively; p = 0.18 and p = 0.35). . Arthroscopic reduction conferred no advantage over conventional fluoroscopic guidance in achieving anatomical reduction of intra-articular distal radial fractures when using a volar locking plate. Cite this article: Bone Joint J 2015; 97-B:957–62


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1101 - 1105
1 Aug 2013
Haug LC Glodny B Deml C Lutz M Attal R

Penetration of the dorsal screw when treating distal radius fractures with volar locking plates is an avoidable complication that causes lesions of the extensor tendon in between 2% and 6% of patients. We examined axial fluoroscopic views of the distal end of the radius to observe small amounts of dorsal screw penetration, and determined the ideal angle of inclination of the x-ray beam to the forearm when making this radiological view. Six volar locking plates were inserted at the wrists of cadavers. The actual screw length was measured under direct vision through a dorsal approach to the distal radius. Axial radiographs were performed for different angles of inclination of the forearm at the elbow. Comparing axial radiological measurements and real screw length, a statistically significant correlation could be demonstrated at an angle of inclination between 5° and 20°. The ideal angle of inclination required to minimise the risk of implanting over-long screws in a dorsal horizon radiological view is 15°. Cite this article: Bone Joint J 2013;95-B:1101–5


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 229 - 234
1 Feb 2015
Choi W Lee HJ Kim D Lee C Lee BG Kim J Lee K

We performed a retrospective study to determine the effect of osteoporosis on the functional outcome of osteoporotic distal radial fractures treated with a volar locking plate. Between 2009 and 2012 a total of 90 postmenopausal women with an unstable fracture of the distal radius treated with a volar locking plate were studied. Changes in the radiological parameters of 51 patients with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 (. sd.  0.56)) were not significantly different from those in 39 patients without osteoporosis (group 2, mean age 61.1, mean T-score –1.72 (. sd. 0.57)). The mean Disabilities of the Arm, Shoulder and Hand (DASH) score at final follow-up was 11.5 (. sd. 12.2) in group 1 and 10.5 (. sd.  13.25) in group 2. The mean modified Mayo wrist score at final follow-up was 79.0 (. sd.  14.04) in group 1 and 82.6 (. sd. 13.1) in group 2. However, this difference was not statistically significant (p = 0.35 for DASH score, p = 0.2 for modified Mayo wrist score). Univariable and multivariable logistic regression analysis showed that only the step-off of the radiocarpal joint was related to both a poor DASH and modified Mayo wrist score. Pearson’s correlation coefficient showed a weak negative relationship only between the T-score and the change in volar tilt (intraclass coefficient –0.26, p = 0.02). We found that osteoporosis does not have a negative effect on the functional outcome and additional analysis did not show a correlation between T-score and outcome. Cite this article: Bone Joint J 2015;97-B:229–34


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 376 - 382
1 Mar 2017
Plant CE Parsons NR Costa ML

Aims. We conducted a study to determine whether radiological parameters correlate with patient reported functional outcome, health-related quality of life and physical measures of function in patients with a fracture of the distal radius. Patients and Methods. The post-operative palmar tilt and ulnar variance at six weeks and 12 months were correlated with the Patient Rated Wrist Evaluation, Disabilities of the Arm, Shoulder and Hand, and EuroQol scores, grip strength, pinch strength and range of movement at three, six and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical fixation, with either percutaneous pinning or reconstruction with a volar plate, for a fracture of the distal radius. Results. Radiological parameters were found to correlate poorly with the patient reported outcomes (r = 0.00 to 0.47) and physical measures of function (r = 0.01 to 0.51) at all intervals. Conclusion. This study raises concerns about the use of radiological parameters to determine management, and to act as a surrogates for successful treatment, in patients with a fracture of the distal radius. Restoration of ‘normal’ radiographic parameters may not be necessary to achieve a satisfactory functional outcome for the patient. Cite this article: Bone Joint J 2017;99-B:376–82


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 993 - 999
1 Sep 2023
van Delft EAK van Bruggen SGJ van Stralen KJ Bloemers FW Sosef NL Schep NWL Vermeulen J

Aims

There is no level I evidence dealing with the optimal period of immobilization for patients with a displaced distal radial fracture following closed reduction. A shorter period might lead to a better functional outcome due to less stiffness and pain. The aim of this study was to investigate whether this period could be safely reduced from six to four weeks.

Methods

This multicentre randomized controlled trial (RCT) included adult patients with a displaced distal radial fracture, who were randomized to be treated with immobilization in a cast for four or six weeks following closed reduction. The primary outcome measure was the Patient-Rated Wrist Evaluation (PRWE) score after follow-up at one year. Secondary outcomes were the abbreviated version of the Disability of Arm, Shoulder and Hand (QuickDASH) score after one year, the functional outcome at six weeks, 12 weeks, and six months, range of motion (ROM), the level of pain after removal of the cast, and complications.


We compared the ceiling effects of two patient-rating scores, the Disability of the Arm, Shoulder and Hand (DASH) and Patient-Rated Wrist Evaluation (PRWE), and a physician-rating score, the Modified Mayo Wrist Score (MMWS) in assessing the outcome of surgical treatment of an unstable distal radial fracture. A total of 77 women with a mean age of 64.2 years (50 to 88) who underwent fixation using a volar locking plate for an unstable distal radial fracture between 2011 and 2013 were enrolled in this study. All completed the DASH and PRWE questionnaires one year post-operatively and were assessed using the MMWS by the senior author. The ceiling effects in the outcome data assessed for each score were estimated. The data assessed with both patient-rating scores, the DASH and PRWE, showed substantial ceiling effects, whereas the data assessed with MMWS showed no ceiling effect. Researchers should be aware of a possible ceiling effect in the assessment of the outcome of the surgical treatment of distal radial fractures using patient-rating scores. It could also increase the likelihood of a type II error. Cite this article: Bone Joint J 2015;97-B:1651–6


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1542 - 1548
2 Nov 2020
Stirling PHC Oliver WM Ling Tan H Brown IDM Oliver CW McQueen MM Molyneux SG Duckworth AD

Aims

The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius.

Methods

We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims

The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging.

Methods

A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1498 - 1505
1 Dec 2019
Sonntag J Woythal L Rasmussen P Branner U Hølmer P Jensen AK Lange KHW Brorson S

Aims

The aim of this study was to investigate the difference in functional outcome after repair and non-repair of the pronator quadratus muscle in patients undergoing surgical treatment for a distal radial fracture with volar plating.

Patients and Methods

A total of 72 patients with a distal radial fracture were included in this randomized clinical trial. They were allocated to have the pronator quadratus muscle repaired or not, after volar locked plating of a distal radial fracture. The patients, the assessor, the primary investigator, and the statistician were blinded to the allocation. Randomization was irreversibly performed using a web application that guaranteed a secure and tamper-free assignment. The primary outcome measure was the Patient Rated Wrist Evaluation (PRWE) after 12 months. Secondary outcomes included the Disabilities of the Arm, Shoulder and Hand (DASH) score, pronation strength, grip strength, the range of pronation and supination, complications, and the operating time.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1370 - 1376
1 Oct 2015
Jordan RW Saithna A

This article is a systematic review of the published literature about the biomechanics, functional outcome and complications of intramedullary nailing of fractures of the distal radius.

We searched the Medline and EMBASE databases and included all studies which reported the outcome of intramedullary (IM) nailing of fractures of the distal radius. Data about functional outcome, range of movement (ROM), strength and complications, were extracted. The studies included were appraised independently by both authors using a validated quality assessment scale for non-controlled studies and the CONSORT statement for randomised controlled trials (RCTs).

The search strategy revealed 785 studies, of which 16 were included for full paper review. These included three biomechanical studies, eight case series and five randomised controlled trials (RCTs).

The biomechanical studies concluded that IM nails were at least as strong as locking plates. The clinical studies reported that IM nailing gave a comparable ROM, functional outcome and grip strength to other fixation techniques.

However, the mean complication rate of intramedullary nailing was 17.6% (0% to 50%). This is higher than the rates reported in contemporary studies for volar plating. It raises concerns about the role of intramedullary nailing, particularly when comparative studies have failed to show that it has any major advantage over other techniques. Further adequately powered RCTs comparing the technique to both volar plating and percutaneous wire fixation are needed.

Cite this article: Bone Joint J 2015;97-B:1370–6.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 205 - 211
1 Feb 2018
Pang EQ Truntzer J Baker L Harris AHS Gardner MJ Kamal RN

Aims

The aim of this study was to test the null hypothesis that there is no difference, from the payer perspective, in the cost of treatment of a distal radial fracture in an elderly patient, aged > 65 years, between open reduction and internal fixation (ORIF) and closed reduction (CR).

Materials and Methods

Data relating to the treatment of these injuries in the elderly between January 2007 and December 2015 were extracted using the Humana and Medicare Advantage Databases. The primary outcome of interest was the cost associated with treatment. Secondary analysis included the cost of common complications. Statistical analysis was performed using a non-parametric t-test and chi-squared test.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1082 - 1089
1 Aug 2015
Tubeuf S Yu G Achten J Parsons NR Rangan A Lamb SE Costa ML

We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with dorsally-displaced fractures of the distal radius.

The cost effectiveness analysis (cost per quality-adjusted life year; QALY) was derived from a multi-centre, two-arm, parallel group, assessor-blind, randomised controlled trial which took place in 18 trauma centres in the United Kingdom. Data from 460 patients were available for analysis, which includes both a National Health Service cost perspective including costs of surgery, implants and healthcare resource use over a 12-month period after surgery, and a societal perspective, which includes the cost of time off work and the need for additional private care.

There was only a small difference in QALYs gained for patients treated with locking-plate fixation over those treated with K-wires. At a mean additional cost of £714 (95% confidence interval 588 to 865) per patient, locking-plate fixation presented an incremental cost effectiveness ratio (ICER) of £89 322 per QALY within the first 12 months of treatment. Sensitivity analyses were undertaken to assess the ICER of locking-plate fixation compared with K-wires. These were greater than £30 000.

Compared with locking-plate fixation, K-wire fixation is a ‘cost saving’ intervention, with similar health benefits.

Cite this article: Bone Joint J 2015;97-B:1082–9.


The aims of this study were to assess the efficacy of a newly designed radiological technique (the radial groove view) for the detection of protrusion of screws in the groove for the extensor pollicis longus tendon (EPL) during plating of distal radial fractures. We also aimed to determine the optimum position of the forearm to obtain this view. We initially analysed the anatomy of the EPL groove by performing three-dimensional CT on 51 normal forearms. The mean horizontal angle of the groove was 17.8° (14° to 23°). We found that the ideal position of the fluoroscopic beam to obtain this view was 20° in the horizontal plane and 5° in the sagittal plane.

We then intra-operatively assessed the use of the radial groove view for detecting protrusion of screws in the EPL groove in 93 fractures that were treated by volar plating. A total of 13 protruding screws were detected. They were changed to shorter screws and these patients underwent CT scans of the wrist immediately post-operatively. There remained one screw that was protruding. These findings suggest that the use of the radial groove view intra-operatively is a good method of assessing the possible protrusion of screws into the groove of EPL when plating a fracture of the distal radius.

Cite this article: Bone Joint J 2013;95-B:1372–6.