Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims

There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA).

Methods

We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 567 - 572
3 Aug 2023
Pasache Lozano RDP Valencia Ramón EA Johnston DG Trenholm JAI

Aims

The aim of this study is to evaluate the change in incidence rate of shoulder arthroplasty, indications, and surgeon volume trends associated with these procedures between January 2003 and April 2021 in the province of Nova Scotia, Canada.

Methods

A total of 1,545 patients between 2005 and 2021 were analyzed. Patients operated on between 2003 and 2004 were excluded due to a lack of electronic records. Overall, 84.1% of the surgeries (n = 1,299) were performed by two fellowship-trained upper limb surgeons, with the remainder performed by one of the 14 orthopaedic surgeons working in the province.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 83 - 90
1 Jan 2022
Batten TJ Gallacher S Evans JP Harding RJ Kitson J Smith CD Thomas WJ

Aims

The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up.

Methods

Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1620 - 1628
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R

Aims

To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes.

Methods

Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims

Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA).

Patients and Methods

A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1060 - 1065
1 Aug 2018
Hwang J Shields MN Berglund LJ Hooke AW Fitzsimmons JS O’Driscoll SW

Aims

The aim of this study was to evaluate two hypotheses. First, that disruption of posterior bundle of the medial collateral ligament (PMCL) has to occur for the elbow to subluxate in cases of posteromedial rotatory instability (PMRI) and second, that ulnohumeral contact pressures increase after disruption of the PMCL.

Materials and Methods

Six human cadaveric elbows were prepared on a custom-designed apparatus which allowed muscle loading and passive elbow motion under gravitational varus. Joint contact pressures were measured sequentially in the intact elbow (INTACT), followed by an anteromedial subtype two coronoid fracture (COR), a lateral collateral ligament (LCL) tear (COR + LCL), and a PMCL tear (COR + LCL + PMCL).


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1512 - 1519
1 Dec 2019
Klug A Konrad F Gramlich Y Hoffmann R Schmidt-Horlohé K

Aims

The aim of this study was to evaluate the outcome of Monteggia-like lesions at midterm follow-up and to determine whether the surgical treatment of the radial head influences the clinical and radiological results.

Patients and Methods

A total of 78 patients with a Monteggia-like lesion, including 44 women and 34 men with a mean age of 54.7 years (19 to 80), were available for assessment after a mean 4.6 years (2 to 9.2). The outcome was assessed using the Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), Mayo Modified Wrist Score (MMWS), and The Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiographs were analyzed for all patients. A total of 12 Mason type I, 16 type II, and 36 type III fractures were included. Surgical treatment consisted of screw fixation for all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) or excision was performed if reconstruction was not possible.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1066 - 1073
1 Aug 2018
Nishida K Hashizume K Nasu Y Ozawa M Fujiwara K Inoue H Ozaki T

Aims

The aim of this study was to report the mid-term clinical outcome of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties when used in patients with rheumatoid arthritis (RA).

Patients and Methods

We retrospectively reviewed 87 elbows, in 75 patients with RA, which was replaced using a cemented JACE total elbow arthroplasty (TEA) between August 2003 and December 2012, with a follow-up of 96%. There were 72 women and three men, with a mean age of 62 years (35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition of each elbow before and after surgery was assessed using the Mayo Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening was defined as a progressive radiolucent line of >1 mm that was completely circumferential around the prosthesis.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 976 - 983
1 Jul 2016
Streubel PN Simone JP Morrey BF Sanchez-Sotelo J Morrey ME

Aims

We describe the use of a protocol of irrigation and debridement (I& D) with retention of the implant for the treatment of periprosthetic infection of a total elbow arthroplasty (TEA). This may be an attractive alternative to staged re-implantation.

Patients and Methods

Between 1990 and 2010, 23 consecutive patients were treated in this way. Three were lost to follow-up leaving 20 patients (21 TEAs) in the study. There were six men and 14 women. Their mean age was 58 years (23 to 76). The protocol involved: component unlinking, irrigation and debridement (I& D), and the introduction of antibiotic laden cement beads; organism-specific intravenous antibiotics; repeat I& D and re-linkage of the implant if appropriate; long-term oral antibiotic therapy.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 224 - 228
1 Feb 2016
Padegimas EM Clyde CT Zmistowski BM Restrepo C Williams GR Namdari S

Aims

Currently, there is little information about the need for peri-operative blood transfusion in patients undergoing shoulder arthroplasty.

The purpose of this study was to identify the rate of transfusion and its predisposing factors, and to establish a blood conservation strategy.

Methods

We identified all patients who had undergone shoulder arthroplasty at our hospital between 1 January 2011 and 31 December 2013. The rate of transfusion was determined from the patient’s records. While there were exceptions, patients typically underwent transfusion if they had a level of haemoglobin of < 7.5 g/dl if asymptomatic, < 9.0 g/dl if they had a significant cardiac history or symptoms of dizziness or light headedness.

Multivariable regression analysis was undertaken to identify predictors of transfusion. High- and low-risk cohorts for transfusion were identified from a receiver operating characteristic (ROC) curve.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1239 - 1243
1 Sep 2014
Zafra M Uceda P Flores M Carpintero P

Patients with pain and loss of shoulder function due to nonunion of a fracture of the proximal third of the humerus may benefit from reverse total shoulder replacement. This paper reports a prospective, multicentre study, involving three hospitals and three surgeons, of 35 patients (28 women, seven men) with a mean age of 69 years (46 to 83) who underwent a reverse total shoulder replacement for the treatment of nonunion of a fracture of the proximal humerus. Using Checchia’s classification, nine nonunions were type I, eight as type II, 12 as type III and six as type IV. The mean follow-up was 51 months (24 to 99). Post-operatively, the patients had a significant decrease in pain (p < 0.001), and a significant improvement in flexion, abduction, external rotation and Constant score (p < 0.001), but not in internal rotation. A total of nine complications were recorded in seven patients: six dislocations, one glenoid loosening in a patient who had previously suffered dislocation, one transitory paresis of the axillary nerve and one infection.

Reverse total shoulder replacement may lead to a significant reduction in pain, improvement in function and a high degree of satisfaction. However, the rate of complications, particularly dislocation, was high.

Cite this article: Bone Joint J 2014;96-B:1239–43.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 526 - 529
1 Apr 2014
Giuseffi SA Streubel P Sperling J Sanchez-Sotelo J

Short uncemented humeral stems can preserve humeral bone stock and facilitate revision surgery but may be prone to malalignment or loosening, especially when used in reverse total shoulder replacement (TSR). We undertook a retrospective review of 44 patients with a mean age of 76 years (59 to 92) who underwent primary reverse TSR with a short uncemented humeral stem. There were 29 females. The indications for joint replacement included cuff tear associated arthropathy (33), avascular necrosis (six), post-traumatic arthritis (two), and inflammatory arthritis (three). At a mean follow-up of 27 months (24 to 40), pain was rated as mild or none in 43 shoulders (97.7%). The mean active elevation improved from 54° (sd 20°) to 142° (sd 25°) and the mean active external rotation from 14° (sd 13°) to 45° (sd 9°). The outcome, as assessed by the modified Neer score, was excellent in 27 (61.3%), satisfactory in 15 (34.1%), and unsatisfactory in two shoulders (4.5%). Stems were well-positioned, without evidence of significant valgus or varus malalignment in 42 TSRs (95.5%). There was no radiological evidence of loosening of the humeral stem in any patient; 13 TSRs (29.5%) had evidence of proximal humeral remodelling and scapular notching was noted in three (6.8%).

Cite this article: Bone Joint J 2014;96-B:526–9.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1377 - 1382
1 Oct 2013
Walch G Mesiha M Boileau P Edwards TB Lévigne C Moineau G Young A

Osteoarthritis results in changes in the dimensions of the glenoid. This study aimed to assess the size and radius of curvature of arthritic glenoids. A total of 145 CT scans were analysed, performed as part of routine pre-operative assessment before total shoulder replacement in 91 women and 54 men. Only patients with primary osteoarthritis and a concentric glenoid were included in the study. The CT scans underwent three-dimensional (3D) reconstruction and were analysed using dedicated computer software. The measurements consisted of maximum superoinferior height, anteroposterior width and a best-fit sphere radius of curvature of the glenoid.

The mean height was 40.2 mm (sd 4.9), the mean width was 29 mm (sd 4.3) and the mean radius of curvature was 35.4 mm (sd 7.8). The measurements were statistically different in men and women and had a Gaussian distribution with marked variation. All measurements were greater than the known values in normal subjects.

With current shoulder replacement systems using a unique backside radius of curvature for the glenoid component, there is a risk of undertaking excessive reaming to adapt the bone to the component resulting in sacrifice of subchondral bone or under-reaming and instability of the component due to a ’rocking horse‘ phenomenon.

Cite this article: Bone Joint J 2013;95-B:1377–82.