In order to achieve satisfactory reduction of
complex distal humeral fractures, adequate exposure of the fracture fragments
and the joint surface is required. Several surgical exposures have
been described for distal humeral fractures. We report our experience
using the anconeus
We describe a series of 20 patients with ununited fractures of the femoral neck following neglected trauma or failed primary internal fixation who were seen at a mean of 7.5 months (2 to 18) following injury. Open reduction and internal fixation of the fracture was performed in all patients, together with a myoperiosteal flap on the quadratus femoris muscle
Aims. Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. Methods. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature. Results. Quantitative MRI revealed a mean reduction of 21.2% (SD 1.3%) of arterial contribution in the lateral plating group and 25.4% (SD 3.2%) in the dual plating group (p = 0.051); representing a mean decrease in arterial contribution of 4.2%. The only significant difference found between both experimental groups was regionally, at the lateral aspect of the distal femur with a mean drop in arterial contribution in the lateral plating group of 18.9% (SD 2.6%) versus 24.0% (SD 3.2%) in the dual plating group (p = 0.048), representing a mean decrease in arterial contribution of 5.1%. Gross dissection revealed complete destruction of periosteal vessels underneath either medial or lateral plates in both groups. The network of genicular branches contributing to the posterior and distal femoral condyles was preserved in all specimens. A medial vascular
The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.Aims
Methods
The treatment of infected exposed implants which have been used for internal fixation usually involves debridement and removal of the implant. This can result in an unstable fracture or spinal column. Muscle flaps may be used to salvage these implants since they provide soft-tissue cover and fresh vascularity. However, there have been few reports concerning their use and these have concentrated on the eradication of the infection and successful soft-tissue cover as the endpoint. There is no information on the factors which may influence the successful salvage of the implant using muscle flaps. We studied the results and factors affecting outcome in nine
Limb salvage after loss of bone and soft tissue may require many operations to obtain soft-tissue cover and bony continuity. We describe a fibula-flexor hallucis longus osteomuscular flap which can provide both soft tissue and bone in a single stage. The flap is based on the peroneal vessels and is covered by a split-thickness skin graft. We report the results in five patients with an average bone defect of 8.3 cm and soft-tissue and skin loss. All regained a normal gait on the donor side; four had clinical and radiological union with excellent soft-tissue cover, but one required later amputation due to diffuse coagulopathy. The flap provides free vascularised bone with muscle cover. It has a dependable, long
We performed a retrospective review of the case notes of 84 consecutive patients who had suffered a severe (Gustilo IIIb or IIIc) open fracture of the tibia after blunt trauma between 1990 and 1998. All had been treated by a radical protocol which included early soft-tissue cover with a muscle flap by a combined orthopaedic and plastic surgery service. Our ideal management is a radical debridement of the wound outside the zone of injury, skeletal stabilisation and early soft-tissue cover with a vascularised muscle flap. All patients were followed clinically and radiologically to union or for one year. After exclusion of four patients (one unrelated death and three patients lost to follow-up), we reviewed 80 patients with 84 fractures. There were 67 men and 13 women with a mean age of 37 years (3 to 89). Five injuries were grade IIIc and 79 grade IIIb; 12 were site 41, 43 were site 42 and 29 were site 43. Debridement and stabilisation of the fracture were invariably performed immediately. In 33 cases the soft-tissue reconstruction was also completed in a single stage, while in a further 30 it was achieved within 72 hours. In the remaining 21 there was a delay beyond 72 hours, often for critical reasons unrelated to the limb injury. All grade-IIIc injuries underwent immediate vascular reconstruction, with an immediate cover by a flap in two. All were salvaged. There were four amputations, one early, one mid-term and two late, giving a final rate of limb salvage of 95%. Overall, nine
Type IIIB open tibial fractures are devastating high-energy injuries. At initial debridement, the surgeon will often be faced with large bone fragments with tenuous, if any, soft-tissue attachments. Conventionally these are discarded to avoid infection. We aimed to determine if orthoplastic reconstruction using mechanically relevant devitalized bone (ORDB) was associated with an increased infection rate in type IIIB open tibial shaft fractures. This was a consecutive cohort study of 113 patients, who had sustained type IIIB fractures of the tibia following blunt trauma, over a four-year period in a level 1 trauma centre. The median age was 44.3 years (interquartile range (IQR) 28.1 to 65.9) with a median follow-up of 1.7 years (IQR 1.2 to 2.1). There were 73 male patients and 40 female patients. The primary outcome measures were deep infection rate and number of operations. The secondary outcomes were nonunion and flap failure.Aims
Patient and Methods
The anterior pelvic internal fixator is increasingly used for
the treatment of unstable, or displaced, injuries of the anterior
pelvic ring. The evidence for its use, however, is limited. The
aim of this paper is to describe the indications for its use, how
it is applied and its complications. We reviewed the case notes and radiographs of 50 patients treated
with an anterior pelvic internal fixator between April 2010 and
December 2015 at a major trauma centre in the United Kingdom. The
median follow-up time was 38 months (interquartile range 24 to 51).Aims
Patients and Methods
Many authors have reported a shorter treatment time when using trifocal bone transport (TFT) rather than bifocal bone transport (BFT) in the management of long segmental tibial bone defects. However, the difference in the incidence of additional procedures, the true complications, and the final results have not been investigated. A total of 86 consecutive patients with a long tibial bone defect (≥ 8 cm), who were treated between January 2008 and January 2015, were retrospectively reviewed. A total of 45 were treated by BFT and 41 by TFT. The median age of the 45 patients in the BFT group was 43 years (interquartile range (IQR) 23 to 54).Aims
Patients and Methods
We evaluated the outcome of treatment of nonunion
of an intracapsular fracture of the femoral neck in young patients
using two cannulated screws and a vascularised bone graft. A total
of 32 patients (15 women and 17 men, with a mean age of 36.5 years;
20 to 50) with failed internal fixation of an intracapsular fracture
were included in the study. Following removal of the primary fixation,
two cannulated compression screws were inserted with a vascularised
iliac crest bone graft based on the ascending branch of the lateral
femoral circumflex artery. At a mean follow-up of 6.8 years (4 to 10), union was achieved
in 27 hips (84%). A total of five patients with a mean age of 40.5
years (35 to 50) had a persistent nonunion and underwent total hip
arthroplasty as also did two patients whose fracture united but
who developed osteonecrosis of the femoral head two years post-operatively. Statistical
analysis showed that younger patients achieved earlier and more
reliable union (p <
0.001). The functional outcome, as assessed
by the Harris Hip score, was better in patients aged <
45 years
compared with those aged >
45 years (p <
0.001). These findings suggest that further fixation using two cannulated
compression screws and a vascularised iliac crest bone graft is
an effective salvage treatment in patients aged <
45 years, in
whom osteosynthesis of a displaced intracapsular fractures of the
femoral neck has failed. Cite this article:
We compared the accuracy, operating time and radiation exposure
of the introduction of iliosacral screws using O-arm/Stealth Navigation
and standard fluoroscopy. Iliosacral screws were introduced percutaneously into the first
sacral body (S1) of ten human cadavers, four men and six women.
The mean age was 77 years (58 to 85). Screws were introduced using
a standard technique into the left side of S1 using C-Arm fluoroscopy
and then into the right side using O-Arm/Stealth Navigation. The
radiation was measured on the surgeon by dosimeters placed under
a lead thyroid shield and apron, on a finger, a hat and on the cadavers.Aims
Materials and Methods
The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery. A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.Objectives
Methods
We hypothesised that the anterior and posterior
walls of the body of the first sacral vertebra could be visualised with
two different angles of inlet view, owing to the conical shape of
the sacrum. Six dry male cadavers with complete pelvic rings and
eight dry sacrums with K-wires were used to study the effect of
canting (angling the C-arm) the fluoroscope towards the head in
5° increments from 10° to 55°. Fluoroscopic images were taken in
each position. Anterior and posterior angles of inclination were
measured between the upper sacrum and the vertical line on the lateral
view. Three authors separately selected the clearest image for overlapping
anterior cortices and the upper sacral canal in the cadaveric models.
The dry bone and K-wire models were scored by the authors, being
sure to check whether the
K-wire was in or out. In the dry bone models the mean score of the relevant inlet position
of the anterior or posterior inclination was 8.875 (standard deviation
( Cite this article:
The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.
We have reviewed our experience in managing 11 patients who sustained an indirect sternal fracture in combination with an upper thoracic spinal injury between 2003 and 2006. These fractures have previously been described as ‘associated’ fractures, but since the upper thorax is an anatomical entity composed of the upper thoracic spine, ribs and sternum joined together, we feel that the term ‘fractures of the upper transthoracic cage’ is a better description. These injuries are a challenge because they are unusual and easily overlooked. They require a systematic clinical and radiological examination to identify both lesions. This high-energy trauma gives severe devastating concomitant injuries and CT with contrast and reconstruction is essential after resuscitation to confirm the presence of all the lesions. The injury level occurs principally at T4–T5 and at the manubriosternal joint. These unstable fractures need early posterior stabilisation and fusion or, if treated conservatively, a very close follow-up.
The outcomes of 261 nerve injuries in 100 patients
were graded good in 173 cases (66%), fair in 70 (26.8%) and poor in
18 (6.9%) at the final review (median 28.4 months (1.3 to 64.2)).
The initial grades for the 42 sutures and graft were 11 good, 14
fair and 17 poor. After subsequent revision repairs in seven, neurolyses
in 11 and free vascularised fasciocutaneous flaps in 11, the final
grades were 15 good, 18 fair and nine poor. Pain was relieved in
30 of 36 patients by nerve repair, revision of repair or neurolysis,
and flaps when indicated. The difference in outcome between penetrating
missile wounds and those caused by explosions was not statistically
significant; in the latter group the onset of recovery from focal
conduction block was delayed (mean 4.7 months (2.5 to 10.2)