Advertisement for orthosearch.org.uk
Results 1 - 20 of 77
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims. The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients. Patients and Methods. We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH). Results. The mean forward elevation in the LP and FA groups was 125.3° (. sd. 21.4) and 148.9° (. sd. 19.8), respectively (p = 0.042), while other clinical factors showed no statistically significant differences between the groups. The changes in NSA and HHH immediately after the operation and at final follow-up were significantly better in the FA group than in the LP group (p = 0.015 and p = 0.021, respectively). Conclusion. For comminuted proximal humeral fractures in osteoporotic patients, locking plate fixation with a fibular strut allograft shows satisfactory short-term results with respect to humeral head support and maintenance of reduction, and may reduce the incidence of complications associated with fixation using a locking plate alone. Cite this article: Bone Joint J 2019;101-B:260–265


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 624 - 633
1 May 2018
Maredza M Petrou S Dritsaki M Achten J Griffin J Lamb SE Parsons NR Costa ML

Aim. The aim of this study was to compare the cost-effectiveness of intramedullary nail fixation and ‘locking’ plate fixation in the treatment of extra-articular fractures of the distal tibia. Patients and Methods. An economic evaluation was conducted from the perspective of the United Kingdom National Health Service (NHS) and personal social services (PSS), based on evidence from the Fixation of Distal Tibia Fractures (UK FixDT) multicentre parallel trial. Data from 321 patients were available for analysis. Costs were collected prospectively over the 12-month follow-up period using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality adjusted life year (QALY) gained, and net monetary benefit. Sensitivity analyses were conducted to test the robustness of cost-effectiveness estimates. Results. Mean NHS and PSS costs were significantly lower for patients treated with an intramedullary nail than for those treated with a locking plate (-£970, 95% confidence interval (CI) -1685 to -256; p = 0.05). There was a small increase in QALYs gained in the nail fixation group (0.01, 95% CI -0.03 to 0.06; p = 0.52). The probability of cost-effectiveness for nail fixation exceeded 90% at cost-effectiveness thresholds as low as £15 000 per additional QALY. The cost-effectiveness results remained robust to several sensitivity analyses. Conclusion. This trial-based economic evaluation suggests that nail fixation is a cost-effective alternative to locking plate fixation. Cite this article: Bone Joint J 2018;100-B:624–33


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 672 - 678
1 May 2010
Robinson CM Wylie JR Ray AG Dempster NJ Olabi B Seah KTM Akhtar MA

We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in unstable fractures. The functional and radiological outcomes were reviewed. At two years after operation the median Constant score was 86 points and the median Disabilities of the Arm, Shoulder and Hand score 17 points. Seven of the patients underwent further surgery, two for failure of fixation, three for dysfunction of the rotator cuff, and two for shoulder stiffness. The two cases of failure of fixation were attributable to violation of the operative protocol. In the 46 patients who retained their humeral head, all the fractures healed within the first year, with no sign of collapse or narrowing of the joint space. Longer follow-up will be required to confirm whether these initially satisfactory results are maintained


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1259 - 1264
1 Sep 2011
Wähnert D Windolf M Brianza S Rothstock S Radtke R Brighenti V Schwieger K

We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm. 3. ) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations. In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1094 - 1099
1 Aug 2018
Gupta S Malhotra A Mittal N Garg SK Jindal R Kansay R

Aims. The aims of this study were to establish whether composite fixation (rail-plate) decreases fixator time and related problems in the management of patients with infected nonunion of tibia with a segmental defect, without compromising the anatomical and functional outcomes achieved using the classical Ilizarov technique. We also wished to study the acceptability of this technique using patient-based objective criteria. Patients and Methods. Between January 2012 and January 2015, 14 consecutive patients were treated for an infected nonunion of the tibia with a gap and were included in the study. During stage one, a radical debridement of bone and soft tissue was undertaken with the introduction of an antibiotic-loaded cement spacer. At the second stage, the tibia was stabilized using a long lateral locked plate and a six-pin monorail fixator on its anteromedial surface. A corticotomy was performed at the appropriate level. During the third stage, i.e. at the end of the distraction phase, the transported fragment was aligned and fixed to the plate with two to four screws. An iliac crest autograft was added to the docking site and the fixator was removed. Functional outcome was assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) score. Results. The mean age of patients was 38.1 years (. sd. 12.7). There were 13 men and one woman. The mean size of the defect was 6.4 cm (. sd. 1.3). the mean follow-up was 33.2 months (24 to 50). The mean external fixator index was 21.2 days/cm (. sd. 1.5). The complication rate was 0.5 (7/14) per patient. According to the classification of Paley, there were five problems and two obstacles but no true complications. The ASAMI bone score was excellent in all patients. The functional ASAMI scores were excellent in eight and good in six patients. The mean MSTS composite score was 83.9% (. sd. 7.1), with an MSTS emotional acceptance score of 4.9 (. sd. 0.5; maximum possible 5). Conclusion. Composite fixation (rail-plate) decreases fixator time and the associated complications, in the treatment of patients of infected nonunion tibia with a segmental defect. It also provides good anatomical and functional results with high emotional acceptance. Cite this article: Bone Joint J 2018;100-B:1094–9


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 241 - 248
1 Feb 2012
Firoozabadi R McDonald E Nguyen T Buckley JM Kandemir U

Filling the empty holes in peri-articular locking plates may improve the fatigue strength of the fixation. The purpose of this in vitro study was to investigate the effect of plugging the unused holes on the fatigue life of peri-articular distal femoral plates used to fix a comminuted supracondylar fracture model. A locking/compression plate was applied to 33 synthetic femurs and then a 6 cm metaphyseal defect was created (AO Type 33-A3). The specimens were then divided into three groups: unplugged, plugged with locking screw only and fully plugged holes. They were then tested using a stepwise or run-out fatigue protocol, each applying cyclic physiological multiaxial loads. All specimens in the stepwise group failed at the 770 N load level. The mean number of cycles to failure for the stepwise specimen was 25 500 cycles (. sd. 1500), 28 800 cycles (. sd.  6300), and 26 400 cycles (. sd. 2300) cycles for the unplugged, screw only and fully plugged configurations, respectively (p = 0.16). The mean number of cycles to failure for the run-out specimens was 42 800 cycles (. sd. 10 700), 36 000 cycles (. sd. 7200), and 36 600 cycles (. sd.  10 000) for the unplugged, screw only and fully plugged configurations, respectively (p = 0.50). There were also no differences in axial or torsional stiffness between the constructs. The failures were through the screw holes at the level of comminution. In conclusion, filling the empty combination locking/compression holes in peri-articular distal femur locking plates at the level of supracondylar comminution does not increase the fatigue life of the fixation in a comminuted supracondylar femoral fracture model (AO 33-A3) with a 6 cm gap


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 247 - 255
1 Feb 2021
Hassellund SS Williksen JH Laane MM Pripp A Rosales CP Karlsen Ø Madsen JE Frihagen F

Aims. To compare operative and nonoperative treatment for displaced distal radius fractures in patients aged over 65 years. Methods. A total of 100 patients were randomized in this non-inferiority trial, comparing cast immobilization with operation with a volar locking plate. Patients with displaced AO/OTA A and C fractures were eligible if one of the following were found after initial closed reduction: 1) dorsal angulation > 10°; 2) ulnar variance > 3 mm; or 3) intra-articular step-off > 2 mm. Primary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) after 12 months. Secondary outcome measures were the Patient-Rated Wrist and Hand Evaluation (PRWHE), EuroQol-5 dimensions 5-level questionnaire (EQ-5D-5L), range of motion (ROM), grip strength, “satisfaction with wrist function” (score 0 to 10), and complications. Results. In all, 89 women and 11 men were included. Mean age was 74 years (65 to 91). Nonoperative treatment was non-inferior to operation with a five-point difference in median QuickDASH after 12 months (p = 0.206). After three and six months QuickDASH favoured the operative group (p = 0.010 and 0.030). Median values for PRWHE were 19 (interquartile range (IRQ) 10 to 32) in the operative group versus ten (IQR 1 to 31) in the nonoperative group at three months (p = 0.064), nine (IQR 2 to 20) versus five (IQR 0 to 13) (p = 0.020) at six months, and two (IQR 0 to 12) versus zero (IQR 0 to 8) (p = 0.019) after 12 months. Range of motion was similar between the groups. The EQ-5D-5L index score was better (mean difference 0.07) in the operative group at three and 12 months (p = 0.008 and 0.020). The complication rate was similar (p = 0.220). The operated patients were more satisfied with wrist function (median 8 (IQR 6 to 9) vs 6 (IQR 5 to 7) at three months, p = 0.002; 9 (IQR 7 to 9) vs 8 (IQR 6 to 8) at six months, p = 0.002; and 10 (IQR 8 to 10) vs 8 (IQR 7 to 9) at 12 months, p < 0.001). Conclusion. Nonoperative treatment was non-inferior to operative treatment based on QuickDASH after one year. Patients in the operative group had a faster recovery and were more satisfied with wrist function. Results from previous trials comparing operative and nonoperative treatment for displaced distal radius fractures in the elderly vary between favouring the operative group and showing similar results between the treatments. This randomized trial suggests that most elderly patients may be treated nonoperatively. Cite this article: Bone Joint J 2021;103-B(2):247–255


Bone & Joint Open
Vol. 3, Issue 12 | Pages 953 - 959
23 Dec 2022
Raval P See A Singh HP

Aims. Distal third clavicle (DTC) fractures are increasing in incidence. Due to their instability and nonunion risk, they prove difficult to treat. Several different operative options for DTC fixation are reported but current evidence suggests variability in operative fixation. Given the lack of consensus, our objective was to determine the current epidemiological trends in DTC as well as their management within the UK. Methods. A multicentre retrospective cohort collaborative study was conducted. All patients over the age of 18 with an isolated DTC fracture in 2019 were included. Demographic variables were recorded: age; sex; side of injury; mechanism of injury; modified Neer classification grading; operative technique; fracture union; complications; and subsequent procedures. Baseline characteristics were described for demographic variables. Categorical variables were expressed as frequencies and percentages. Results. A total of 859 patients from 18 different NHS trusts (15 trauma units and three major trauma centres) were included. The mean age was 57 years (18 to 99). Overall, 56% of patients (n = 481) were male. The most common mechanisms of injury were simple fall (57%; n = 487) and high-energy fall (29%; n = 248); 87% (n = 748) were treated conservatively and 54% (n = 463) were Neer type I fractures. Overall, 32% of fractures (n = 275) were type II (22% type IIa (n = 192); 10% type IIb (n = 83)). With regards to operative management, 89% of patients (n = 748) who underwent an operation were under the age of 60. The main fixation methods were: hook plate (n = 47); locking plate (n = 34); tightrope (n = 5); and locking plate and tight rope (n = 7). Conclusion. Our study is the largest epidemiological review of DTC fractures in the UK. It is also the first to review the practice of DTC fixation. Most fractures are being treated nonoperatively. However, younger patients, suffering a higher-energy mechanism of injury, are more likely to undergo surgery. Hook plates are the predominantly used fixation method followed by locking plate. The literature is sparse on the best method of fixation for optimal outcomes for these patients. To answer this, a pragmatic RCT to determine optimal fixation method is required. Cite this article: Bone Jt Open 2022;3(12):953–959


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1402 - 1405
1 Oct 2013
Parker M Cawley S Palial V

A consecutive series of 320 patients with an intracapsular fracture of the hip treated with a dynamic locking plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients were followed for a minimum of two years. During the follow-up period 109 patients died.

There were 112 undisplaced fractures, of which three (2.7%) developed nonunion or re-displacement and five (4.5%) developed avascular necrosis of the femoral head. Revision to an arthroplasty was required for five patients (4.5%). A further six patients (5.4%) had elective removal of the plate and screws.

There were 208 displaced fractures, of which 32 (15.4%) developed nonunion or re-displacement and 23 (11.1%) developed avascular necrosis. A further four patients (1.9%) developed a secondary fracture around the TFN. Revision to a hip replacement was required for 43 patients (20.7%) patients and a further seven (3.3%) had elective removal of the plate and screws.

It is suggested that the stronger distal fixation combined with rotational stability may lead to a reduced incidence of complications related to the healing of the fracture when compared with other contemporary fixation devices but this needs to be confirmed in further studies.

Cite this article: Bone Joint J 2013;95-B:1402–5.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 951 - 957
1 Jul 2017
Poole WEC Wilson DGG Guthrie HC Bellringer SF Freeman R Guryel E Nicol SG

Aims

Fractures of the distal femur can be challenging to manage and are on the increase in the elderly osteoporotic population. Management with casting or bracing can unacceptably limit a patient’s ability to bear weight, but historically, operative fixation has been associated with a high rate of re-operation. In this study, we describe the outcomes of fixation using modern implants within a strategy of early return to function.

Patients and Methods

All patients treated at our centre with lateral distal femoral locking plates (LDFLP) between 2009 and 2014 were identified. Fracture classification and operative information including weight-bearing status, rates of union, re-operation, failure of implants and mortality rate, were recorded.


Bone & Joint Research
Vol. 6, Issue 4 | Pages 216 - 223
1 Apr 2017
Ang BFH Chen JY Yew AKS Chua SK Chou SM Chia SL Koh JSB Howe TS

Objectives. External fixators are the traditional fixation method of choice for contaminated open fractures. However, patient acceptance is low due to the high profile and therefore physical burden of the constructs. An externalised locking compression plate is a low profile alternative. However, the biomechanical differences have not been assessed. The objective of this study was to evaluate the axial and torsional stiffness of the externalised titanium locking compression plate (ET-LCP), the externalised stainless steel locking compression plate (ESS-LCP) and the unilateral external fixator (UEF). Methods. A fracture gap model was created to simulate comminuted mid-shaft tibia fractures using synthetic composite bones. Fifteen constructs were stabilised with ET-LCP, ESS-LCP or UEF (five constructs each). The constructs were loaded under both axial and torsional directions to determine construct stiffness. Results. The mean axial stiffness was very similar for UEF (528 N/mm) and ESS-LCP (525 N/mm), while it was slightly lower for ET-LCP (469 N/mm). One-way analysis of variance (ANOVA) testing in all three groups demonstrated no significant difference (F(2,12) = 2.057, p = 0.171). There was a significant difference in mean torsional stiffness between the UEF (0.512 Nm/degree), the ESS-LCP (0.686 Nm/degree) and the ET-LCP (0.639 Nm/degree), as determined by one-way ANOVA (F(2,12) = 6.204, p = 0.014). A Tukey post hoc test revealed that the torsional stiffness of the ESS-LCP was statistically higher than that of the UEF by 0.174 Nm/degree (p = 0.013). No catastrophic failures were observed. Conclusion. Using the LCP as an external fixator may provide a viable and attractive alternative to the traditional UEF as its lower profile makes it more acceptable to patients, while not compromising on axial and torsional stiffness. Cite this article: B. F. H. Ang, J. Y. Chen, A. K. S. Yew, S. K. Chua, S. M. Chou, S. L. Chia, J. S. B. Koh, T. S. Howe. Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness. Bone Joint Res 2017;6:216–223. DOI: 10.1302/2046-3758.64.2000470


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 795 - 800
1 Jul 2023
Parsons N Achten J Costa ML

Aims. To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus locking plate in the five years after participating in the Fixation of Distal Tibia fracture (FixDT) trial. Methods. The FixDT trial reported the results for 321 patients randomized to nail or locking plate fixation in the first 12 months after their injury. In this follow-up study, we report the results of 170 of the original participants who agreed to be followed up until five years. Participants reported their Disability Rating Index (DRI) and health-related quality of life (EuroQol five-dimension three-level questionnaire) annually by self-reported questionnaire. Further surgical interventions related to the fracture were also recorded. Results. There was no evidence of a difference in patient-reported disability, health-related quality of life, or the need for further surgery between participants treated with either type of fixation at five years. Considering the combined results for all participants, there was no significant change in DRI scores after the first 12 months of follow-up (difference between 12 and 24 months, 3.3 (95% confidence interval -1.8 to 8.5); p = 0.203), with patients reporting around 20% disability at five years. Conclusion. This study shows that the moderate levels of disability and reduced quality of life reported by participants 12 months after a fracture of the distal tibia persist in the medium term, with little evidence of improvement after the first year. Cite this article: Bone Joint J 2023;105-B(7):795–800


Bone & Joint Open
Vol. 4, Issue 8 | Pages 584 - 593
15 Aug 2023
Sainio H Rämö L Reito A Silvasti-Lundell M Lindahl J

Aims. Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures. Methods. We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral locking plate between 2009 and 2018. The patients who underwent secondary surgery due to fracture healing problem or plate failure were considered having nonunion. Background knowledge of risk factors of distal femur fracture nonunion based on previous literature was used to form an initial set of variables. A logistic regression model was used with previously identified patient- and injury-related variables (age, sex, BMI, diabetes, smoking, periprosthetic fracture, open fracture, trauma energy, fracture zone length, fracture comminution, medial side comminution) in the first analysis and with treatment-related variables (different surgeon-controlled factors, e.g. plate length, screw placement, and proximal fixation) in the second analysis to predict the nonunion leading to secondary surgery in distal femur fractures. Results. We were able to include 299 fractures in 291 patients. Altogether, 31/299 fractures (10%) developed nonunion. In the first analysis, pseudo-R. 2. was 0.27 and area under the receiver operating characteristic curve (AUC) was 0.81. BMI was the most important variable in the prediction. In the second analysis, pseudo-R. 2. was 0.06 and AUC was 0.67. Plate length was the most important variable in the prediction. Conclusion. The model including patient- and injury-related factors had moderate fit and predictive ability in the prediction of distal femur fracture nonunion leading to secondary surgery. BMI was the most important variable in prediction of nonunion. Surgeon-controlled factors had a minor role in prediction of nonunion. Cite this article: Bone Jt Open 2023;4(8):584–593


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (. sd. 33 900) vs 12 800 cycles (. sd. 6100); p = 0.007) and mean axial stiffness (220 N/mm (. sd. 80) vs 70 N/mm (. sd. 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (. sd. 0.9) vs 5.1 Nm/° (. sd. 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (. sd. 25 600) vs 52 400 cycles (. sd. 22 500); p = 0.04). The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients. Cite this article: Bone Joint J 2014;96-B:114–21


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 846 - 850
1 Jun 2016
Hoskins W Sheehy R Edwards ER Hau RC Bucknill A Parsons N Griffin XL

Aims. Fractures of the distal femur are an important cause of morbidity. Their optimal management remains controversial. Contemporary implants include angular-stable anatomical locking plates and locked intramedullary nails (IMNs). We compared the long-term patient-reported functional outcome of fixation of fractures of the distal femur using these two methods of treatment. Patients and Methods. A total of 297 patients were retrospectively identified from a State-wide trauma registry in Australia: 195 had been treated with a locking plate and 102 with an IMN. Baseline characteristics of the patients and their fractures were recorded. Health-related quality-of-life, functional and radiographic outcomes were compared using mixed effects regression models at six months and one year. Results. There was a clinically relevant and significant difference in quality-of-life at six months in favour of fixation with an IMN (mean difference in EuroQol-5 Dimensions Score (EQ-5D) = 0.12; 95% CI 0.02 to 0.22; p = 0.025). There was weak evidence that this trend continued to one year (mean difference EQ-5D = 0.09; 95% CI -0.01 to 0.19; p = 0.073). There was a significant although very small reduction in angular deformity using an IMN (mean difference -1.02; 95% CI -1.99 to -0.06; p = 0.073). There was no evidence that there was a difference in any other outcomes at any time point. Take home message: IMN may be a superior treatment compared with anatomical locking plates for fractures of the distal femur. These findings are concordant with other data from pilot randomised studies which favour treatment of these fractures with an IMN. This study strongly supports the need for a definitive randomised trial. Cite this article: Bone Joint J 2016;98-B:846–50


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 956 - 962
1 Jul 2014
Ahearn N Oppy A Halliday R Rowett-Harris J Morris SA Chesser TJ Livingstone JA

Unstable bicondylar tibial plateau fractures are rare and there is little guidance in the literature as to the best form of treatment. We examined the short- to medium-term outcome of this injury in a consecutive series of patients presenting to two trauma centres. Between December 2005 and May 2010, a total of 55 fractures in 54 patients were treated by fixation, 34 with peri-articular locking plates and 21 with limited access direct internal fixation in combination with circular external fixation using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively, patient-reported outcome measures including the WOMAC index and SF-36 scores showed functional deficits, although there was no significant difference between the two forms of treatment. Despite low outcome scores, patients were generally satisfied with the outcome. We achieved good clinical and radiological outcomes, with low rates of complication. In total, only three patients (5%) had collapse of the joint of > 4 mm, and metaphysis to diaphysis angulation of greater than 5º, and five patients (9%) with displacement of > 4 mm. All patients in our study went on to achieve full union. This study highlights the serious nature of this injury and generally poor patient-reported outcome measures following surgery, despite treatment by experienced surgeons using modern surgical techniques. Our findings suggest that treatment of complex bicondylar tibial plateau fractures with either a locking plate or a TSF gives similar clinical and radiological outcomes. Cite this article: Bone Joint J 2014;96-B:956–62


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 984 - 988
1 Jul 2010
Guo JJ Tang N Yang HL Tang TS

We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients’ age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively). After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score, but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1264 - 1270
1 Sep 2015
Karantana A Scammell BE Davis TRC Whynes DK

This study compares the cost-effectiveness of treating dorsally displaced distal radial fractures with a volar locking plate and percutaneous fixation. It was performed from the perspective of the National Health Service (NHS) using data from a single-centre randomised controlled trial. In total 130 patients (18 to 73 years of age) with a dorsally displaced distal radial fracture were randomised to treatment with either a volar locking plate (n = 66) or percutaneous fixation (n = 64). The methodology was according to National Institute for Health and Care Excellence guidance for technology appraisals. . There were no significant differences in quality of life scores between groups at any time point in the study. Both groups returned to baseline one year post-operatively. . NHS costs for the plate group were significantly higher (p < 0.001, 95% confidence interval 497 to 930). For an additional £713, fixation with a volar locking plate offered 0.0178 additional quality-adjusted life years in the year after surgery. The incremental cost-effectiveness ratio (ICER) for plate fixation relative to percutaneous fixation at list price was £40 068. When adjusting the prices of the implants for a 20% hospital discount, the ICER was £31 898. Patients who underwent plate fixation did not return to work earlier. We found no evidence to support the cost-effectiveness, from the perspective of the NHS, of fixation using a volar locking plate over percutaneous fixation for the operative treatment of a dorsally displaced radial fracture. Cite this article: Bone Joint J 2015;97-B:1264–70


Bone & Joint Research
Vol. 5, Issue 5 | Pages 191 - 197
1 May 2016
Kienast B Kowald B Seide K Aljudaibi M Faschingbauer M Juergens C Gille J

Objectives. The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator. Materials and Methods. An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing consolidation of a fracture or nonunion and is an appropriate parameter for the course of bone healing. At our centre, clinical application has been performed in 56 patients suffering nonunion or fracture of the femur. Results. A total of 39 cases of clinical application were reviewed for this study. In total, four different types of healing curves were observed: fast healing; slow healing; plateau followed by healing; and non-healing. Conclusion. The electronically instrumented internal fixator proved to be valuable for the assessment of bone healing in difficult healing situations. Cost-effective manufacturing is possible because the used electronic components are derived from large-scale production. The incorporation of microelectronics into orthopaedic implants will be an important innovation in future clinical care. Cite this article: B. Kienast, B. Kowald, K. Seide, M. Aljudaibi, M. Faschingbauer, C. Juergens, J. Gille. An electronically instrumented internal fixator for the assessment of bone healing. Bone Joint Res 2016;5:191–197. DOI: 10.1302/2046-3758.55.2000611


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1544 - 1550
1 Nov 2013
Uchiyama S Itsubo T Nakamura K Fujinaga Y Sato N Imaeda T Kadoya M Kato H

This multicentre prospective clinical trial aimed to determine whether early administration of alendronate (ALN) delays fracture healing after surgical treatment of fractures of the distal radius. The study population comprised 80 patients (four men and 76 women) with a mean age of 70 years (52 to 86) with acute fragility fractures of the distal radius requiring open reduction and internal fixation with a volar locking plate and screws. Two groups of 40 patients each were randomly allocated either to receive once weekly oral ALN administration (35 mg) within a few days after surgery and continued for six months, or oral ALN administration delayed until four months after surgery. Postero-anterior and lateral radiographs of the affected wrist were taken monthly for six months after surgery. No differences between groups was observed with regard to gender (p = 1.0), age (p = 0.916), fracture classification (p = 0.274) or bone mineral density measured at the spine (p = 0.714). The radiographs were assessed by three independent assessors. There were no significant differences in the mean time to complete cortical bridging observed between the ALN group (3.5 months (. se. 0.16)) and the no-ALN group (3.1 months (. se. 0.15)) (p = 0.068). All the fractures healed in the both groups by the last follow-up. Improvement of the Quick-Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, grip strength, wrist range of movement, and tenderness over the fracture site did not differ between the groups over the six-month period. Based on our results, early administration of ALN after surgery for distal radius fracture did not appear to delay fracture healing times either radiologically or clinically. Cite this article: Bone Joint J 2013;95-B:1544–50