header advert
Results 1 - 20 of 110
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 189 - 195
1 Feb 2007
Levy JC Virani N Pupello D Frankle M

We report the use of the reverse shoulder prosthesis in the revision of a failed shoulder hemiarthroplasty in 19 shoulders in 18 patients (7 men, 11 women) with severe pain and loss of function. The primary procedure had been undertaken for glenohumeral arthritis associated with severe rotator cuff deficiency. Statistically significant improvements were seen in pain and functional outcome. After a mean follow-up of 44 months (24 to 89), mean forward flexion improved by 26.4° and mean abduction improved by 35°. There were six prosthesis-related complications in six shoulders (32%), five of which had severe bone loss of the glenoid, proximal humerus or both. Three shoulders (16%) had non-prosthesis related complications. The use of the reverse shoulder prosthesis provides improvement in pain and function for patients with failure of a hemiarthroplasty for glenohumeral arthritis and rotator cuff deficiency. However, high rates of complications were associated with glenoid and proximal humeral bone loss


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 745 - 750
1 Jun 2008
Millar NL Murrell GAC

We identified ten patients who underwent arthroscopic revision of anterior shoulder stabilisation between 1999 and 2005. Their results were compared with 15 patients, matched for age and gender, who had a primary arthroscopic stabilisation during the same period.

At a mean follow-up of 37 and 36 months, respectively, the scores for pain and shoulder function improved significantly between the pre-operative and follow-up visits in both groups (p = 0.002), with no significant difference between them (p = 0.4). The UCLA and Rowe shoulder scores improved significantly (p = 0.004 and p = 0.002, respectively), with no statistically significant differences between groups (p = 0.6). Kaplan-Meier analysis for time to recurrent instability showed no differences between the groups (p = 0.2).

These results suggest that arthroscopic revision anterior shoulder stabilisation is as reliable as primary arthroscopic stabilisation for patients who have had previous open surgery for recurrent anterior instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 78 - 83
1 Jan 2006
Sneftrup SB Jensen SL Johannsen HV Søjbjerg JO

We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 points (40 to 100) at the latest follow-up. There was a marked relief of pain, but the range of movement showed no overall improvement. Two patients had a second revision because of infection and two for aseptic loosening. The estimated five-year survival rate of the prosthesis was 83.1% (95% confidence interval 61.1 to 93.3). Revision elbow arthroplasty using the Coonrad-Morrey implant provided satisfactory results but with complications occurring in 13 cases.


Bone & Joint Research
Vol. 13, Issue 4 | Pages 169 - 183
15 Apr 2024
Gil-Melgosa L Llombart-Blanco R Extramiana L Lacave I Abizanda G Miranda E Agirre X Prósper F Pineda-Lucena A Pons-Villanueva J Pérez-Ruiz A

Aims

Rotator cuff (RC) injuries are characterized by tendon rupture, muscle atrophy, retraction, and fatty infiltration, which increase injury severity and jeopardize adequate tendon repair. Epigenetic drugs, such as histone deacetylase inhibitors (HDACis), possess the capacity to redefine the molecular signature of cells, and they may have the potential to inhibit the transformation of the fibro-adipogenic progenitors (FAPs) within the skeletal muscle into adipocyte-like cells, concurrently enhancing the myogenic potential of the satellite cells.

Methods

HDACis were added to FAPs and satellite cell cultures isolated from mice. The HDACi vorinostat was additionally administered into a RC injury animal model. Histological analysis was carried out on the isolated supra- and infraspinatus muscles to assess vorinostat anti-muscle degeneration potential.


Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims

Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model.

Methods

A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1059 - 1065
1 Aug 2008
Elhassan B Ozbaydar M Massimini D Diller D Higgins L Warner JJP

Transfer of pectoralis major has evolved as the most favoured option for the management of the difficult problem of irreparable tears of subscapularis. We describe our experience with this technique in 30 patients divided into three groups. Group I comprised 11 patients with a failed procedure for instability of the shoulder, group II included eight with a failed shoulder replacement and group III, 11 with a massive tear of the rotator cuff. All underwent transfer of the sternal head of pectoralis major to restore the function of subscapularis. At the latest follow-up pain had improved in seven of the 11 patients in groups I and III, but in only one of eight in group II. The subjective shoulder score improved in seven patients in group I, in one in group II and in six in group III. The mean Constant score improved from 40.9 points (28 to 50) in group I, 32.9 (17 to 47) in group II and 28.7 (20 to 42) in group III pre-operatively to 60.8 (28 to 89), 41.9 (24 to 73) and 52.3 (24 to 78), respectively. Failure of the tendon transfer was highest in group II and was associated with pre-operative anterior subluxation of the humeral head. We conclude that in patients with irreparable rupture of subscapularis after shoulder replacement there is a high risk of failure of transfer of p?ctoralis major, particularly if there is pre-operative anterior subluxation of the humeral head


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1184 - 1187
1 Sep 2007
Rispoli DM Sperling JW Athwal GS Schleck CD Cofield RH

We have examined the relief from pain and the functional outcome in 18 patients who underwent resection arthroplasty of the shoulder as a salvage operation between 1988 and 2002. The indications included failed shoulder replacement in 17, with infection in 13, and chronic septic arthritis in one. The mean follow-up was 8.3 years (2.5 to 16.6). Two intra-operative fractures of the humerus occurred, both of which healed. The level of pain was significantly decreased (t-test, p < 0.001) but five patients continued to have moderate to severe pain. The mean active elevation was 70° (0° to 150°) postoperatively and represented an improvement from 39° (0° to 140°) (t-test, p = 0.003), but internal and external rotation were hardly changed. The mean number of positive answers on the 12-question Simple Shoulder Test was 3.1 (0 to 12) but the shoulder was generally comfortable when the arm was positioned at rest by the side. The mean post-operative American Shoulder and Elbow Surgeon’s score was 36 (8 to 73). Despite applying this procedure principally to failed shoulder replacements, the results were similar to those reported in the literature for patients after severe fracture-dislocation. Reduction of pain is possible in one half to two-thirds of patients. The outcome of this operation in providing relief from pain cannot be guaranteed, but the shoulder is usually comfortable at rest, albeit with profound functional limitations


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1462 - 1467
1 Nov 2008
Patel RV Apostle K Leith JM Regan WD

We have investigated the outcome of arthroscopic revision surgery for recurrent instability of the shoulder after failed primary anterior stabilisation. We identified 40 patients with failed primary open or arthroscopic anterior stabilisation of the shoulder who had been treated by revision arthroscopic capsulolabral reconstruction and followed up for a mean of 36 months (12 to 87). There were 34 men and six women with a mean age of 33.1 years (15 to 48). Details of the patients, the technique of the primary procedure, the operative findings at revision and the clinical outcome were evaluated by reviewing the medical records, physical examination and the use of the Western Ontario shoulder instability index score, the American Shoulder and Elbow Surgeons score and the health status questionnaire 12. Recurrent instability persisted in four patients after the revision arthroscopic procedure. At the final follow-up, the mean American Shoulder and Elbow Surgeons score was 81.1 (17.5 to 99.5) and the mean Western Ontario shoulder instability index score was 68.2 (20 to 98.2). Quality-of-life scoring showed good to excellent results in most patients. Arthroscopic revision capsulolabral reconstruction can provide a satisfactory outcome in selected patients for recurrent instability of the shoulder provided that no large Hill-Sachs lesion is present


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 646 - 649
1 Jul 2001
Shergill G Bonney G Munshi P Birch R

The outcome of 260 repairs of the radial and posterior interosseous nerves, graded by Seddon’s modification of the Medical Research Council Special Committee’s system, was analysed according to four patterns of injury; open ‘tidy’, open ‘untidy’, closed traction, and those associated with injury to the axillary or brachial artery. We studied the effect on the outcome of delay in effecting repair and of the length of the defect in the nerve trunk. Of the 242 repairs of the radial nerve we found that 30% had good results and 28% fair; 42% of the repairs had failed. The violence of injury was the most important factor in determining the outcome. Of the open ‘tidy’ repairs, 79% achieved a good or fair result, and 36% of cases with arterial injury also reached this level. Most repairs failed when the defect in the nerve trunk exceeded 10 cm. When the repairs were carried out within 14 days of injury, 49% achieved a good result; only 28% of later repairs did so. All repairs undertaken after 12 months failed. Of the 18 repairs of the posterior interosseous nerve, 16 achieved a good result


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 661 - 667
1 May 2010
van Riet RP Sanchez-Sotelo J Morrey BF

There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 224 - 229
1 Feb 2010
Arora R Lutz M Zimmermann R Krappinger D Niederwanger C Gabl M

We report the use of a free vascularised iliac bone graft in the treatment of 21 patients (19 men and 2 women) with an avascular nonunion of the scaphoid in which conventional bone grafting had previously failed. The mean age of the patients was 32 years (23 to 46) and the dominant wrist was affected in 14. The mean interval from fracture to the vascularised bone grafting was 39 months (9 to 62). Pre-operative MRI showed no contrast enhancement in the proximal fragment in any patient. Fracture union was assessed radiologically or with CT scans if the radiological appearances were inconclusive. At a mean follow-up of 5.6 years (2 to 11) union was obtained in 16 patients. The remaining five patients with a persistent nonunion continued to experience pain, reduced grip strength and limited range of wrist movement. In the successfully treated patients the grip strength and range of movement did not recover to match the uninjured side. Prevention of progressive carpal collapse, the absence of donor site morbidity, good subjective results and pain relief, justifies this procedure in the treatment of recalcitrant nonunion of the scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 74 - 78
1 Jan 2000
Gelinas JJ Faber KJ Patterson SD King GJW

We have treated 22 patients with an elbow contracture using a static progressive turnbuckle splint for a mean of 4.5 ± 1.8 months. All had failed to improve with supervised physiotherapy and splinting. The mean range of flexion before splintage was from 32 ± 10° to 108 ± 19° and afterwards from 26 ± 10° (p = 0.02) to 127 ± 12° (p = 0.0001). A total of 11 patients gained a ‘functional arc of movement,’ defined as at least 30° to 130°. In eight patients movement improved with turnbuckle splinting, but the functional arc was not achieved. Six of these were satisfied and did not wish to proceed with surgical treatment and two had release of the elbow contracture. In three patients movement did not improve with the use of the turnbuckle splint and one subsequently had surgical treatment. Our findings have shown that turnbuckle splinting is a safe and effective treatment which should be considered in patients whose established elbow contractures have failed to respond to conventional physiotherapy


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1273 - 1277
1 Sep 2010
Larson AN Adams RA Morrey BF

Between 1996 and 2008, nine patients with severe post-traumatic arthritis underwent revision of a failed interposition arthroplasty of the elbow with a further interposition procedure using an allograft of tendo Achillis at a mean of 5.6 years (0.7 to 13.1) after the initial procedure. There were eight men and one woman with a mean age of 47 years (36 to 56). The mean follow-up was 4.7 years (2 to 8). The mean Mayo Elbow Performance score improved from 49 (15 to 65) pre-operatively to 73 (55 to 95) (p = 0.04). The mean Disability of the Arm, Shoulder and Hand score was 26 (7 to 42). One patient was unavailable for clinical follow-up and one underwent total elbow replacement three months post-operatively. Of the remaining patients, one had an excellent, two had good, three fair and one a poor result. Subjectively, five of the nine patients were satisfied. Four continued manual labour. Revision interposition arthroplasty is an option for young, active patients with severe post-traumatic arthritis who require both mobility and durability of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 504 - 510
1 Apr 2009
Henkus HE de Witte PB Nelissen RGHH Brand R van Arkel ERA

In a prospective randomised study we compared the results of arthroscopic subacromial bursectomy alone with debridement of the subacromial bursa followed by acromioplasty. A total of 57 patients with a mean age of 47 years (31 to 60) suffering from primary subacromial impingement without a rupture of the rotator cuff who had failed previous conservative treatment were entered into the trial. The type of acromion was classified according to Bigliani. Patients were assessed at follow-up using the Constant score, the simple shoulder test and visual analogue scores for pain and functional impairment. One patient was lost to follow-up. At a mean follow-up of 2.5 years (1 to 5) both bursectomy and acromioplasty gave good clinical results. No statistically significant differences were found between the two treatments. The type of acromion and severity of symptoms had a greater influence on the clinical outcome than the type of treatment. As a result, we believe that primary subacromial impingement syndrome is largely an intrinsic degenerative condition rather than an extrinsic mechanical disorder


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 406 - 413
1 May 1999
McMahon PJ Dettling J Sandusky MD Tibone JE Lee TQ

Surgical treatment for traumatic, anterior glenohumeral instability requires repair of the anterior band of the inferior glenohumeral ligament, usually at the site of glenoid insertion, often combined with capsuloligamentous plication. In this study, we determined the mechanical properties of this ligament and the precise anatomy of its insertion into the glenoid in fresh-frozen glenohumeral joints of cadavers. Strength was measured by tensile testing of the glenoid-soft-tissue-humerus (G-ST-H) complex. Two other specimens of the complex were frozen in the position of apprehension, serially sectioned perpendicular to the plane containing the anterior and posterior rims of the glenoid, and stained with Toluidine Blue. On tensile testing, eight G-ST-H complexes failed at the site of the glenoid insertion, representing a Bankart lesion, two at the insertion into the humerus, and two at the midsubstance. For those which failed at the glenoid attachment the mean yield load was 491.0 N and the mean ultimate load, 585.0 N. At the glenoid region, stress at yield was 7.8 ± 1.3 MPa and stress at failure, 9.2 ± 1.5 MPa. The permanent deformation, defined as the difference between yield and ultimate deformation, was only 2.3 ± 0.8 mm. The strain at yield was 13.0 ± 0.7% and at failure, 15.4 ± 1.2%; therefore permanent strain was only 2.4 ± 1.1%. Histological examination showed that there were two attachments of the anterior band of the inferior glenohumeral ligament at the site of the glenoid insertion. In one, poorly organised collagen fibres inserted into the labrum. In the other, dense collagen fibres were attached to the front of the neck of the glenoid


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 57 - 61
1 Jan 2011
Naveed MA Kitson J Bunker TD

The combination of an irreparable tear of the rotator cuff and destructive arthritis of the shoulder joint may cause severe pain, disability and loss of independence in the aged. Standard anatomical shoulder replacements depend on a functioning rotator cuff, and hence may fail in the presence of tears in the cuff. Many designs of non-anatomical constrained or semi-constrained prostheses have been developed for cuff tear arthropathy, but have proved unsatisfactory and were abandoned. The DePuy Delta III reverse prosthesis, designed by Grammont, medialises and stabilises the centre of rotation of the shoulder joint and has shown early promise. This study evaluated the mid-term clinical and radiological results of this arthroplasty in a consecutive series of 50 shoulders in 43 patients with a painful pseudoparalysis due to an irreparable cuff tear and destructive arthritis, performed over a period of seven years by a single surgeon. A follow-up of 98% was achieved, with a mean duration of 39 months (8 to 81). The mean age of the patients at the time of surgery was 81 years (59 to 95). The female to male ratio was 5:1. During the seven years, six patients died of natural causes. The clinical outcome was assessed using the American Shoulder and Elbow score, the Oxford Shoulder Score and the Short-form 36 score. A radiological review was performed using the Sirveaux score for scapular notching. The mean American Shoulder and Elbow score was 19 (95% confidence interval (CI) 14 to 23) pre-operatively, and 65 (95% CI 48 to 82) (paired t-test, p < 0.001) at final follow-up. The mean Oxford score was 44 (95% CI 40 to 51) pre-operatively and 23 (95% CI 18 to 28) (paired t-test, p < 0.001) at final follow-up. The mean maximum elevation improved from 55° pre-operatively to 105° at final follow-up. There were seven complications during the whole series, although only four patients required further surgery


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 942 - 946
1 Jul 2013
Dattani R Ramasamy V Parker R Patel VR

There is little published information on the health impact of frozen shoulder. The purpose of this study was to assess the functional and health-related quality of life outcomes following arthroscopic capsular release (ACR) for contracture of the shoulder. Between January 2010 and January 2012 all patients who had failed non-operative treatment including anti-inflammatory medication, physiotherapy and glenohumeral joint injections for contracture of the shoulder and who subsequently underwent an ACR were enrolled in the study. A total of 100 patients were eligible; 68 underwent ACR alone and 32 had ACR with a subacromial decompression (ASD). ACR resulted in a highly significant improvement in the range of movement and functional outcome, as measured by the Oxford shoulder score and EuroQol EQ-5D index. The mean cost of a quality-adjusted life year (QALY) for an ACR and ACR with an ASD was £2563 and £3189, respectively. . ACR is thus a cost-effective procedure that can restore relatively normal function and health-related quality of life in most patients with a contracture of the shoulder within six months after surgery; and the beneficial effects are not related to the duration of the presenting symptoms. Cite this article: Bone Joint J 2013;95-B:942–6


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1369 - 1374
1 Oct 2005
Athwal GS Chin PY Adams RA Morrey BF

We reviewed 20 patients who had undergone a Coonrad-Morrey total elbow arthroplasty after resection of a primary or metastatic tumour from the elbow or distal humerus between 1980 and 2002. Eighteen patients underwent reconstruction for palliative treatment with restoration of function after intralesional surgery and two after excision of a primary bone tumour. The mean follow-up was 30 months (1 to 192). Five patients (25%) were alive at the final follow-up; 14 (70%) had died of their disease and one of unrelated causes. Local control was achieved in 15 patients (75%). The mean Mayo Elbow Performance Score improved from 22 (5 to 45) to 75 points (55 to 95). Four reconstructions (20%) failed and required revision. Seven patients (35%) had early complications, the most frequent being nerve injury (25%). There were no infections or wound complications although 18 patients (90%) had radiotherapy, chemotherapy or both. The Coonrad-Morrey total elbow arthroplasty provides good relief from pain and a good functional outcome after resection of tumours of the elbow. The rates of complications involving local recurrence of tumour (25%) and nerve injury (25%) are of concern


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 523 - 529
1 Apr 2013
Henseler JF Nagels J van der Zwaal P Nelissen RGHH

Surgical repair of posterosuperior rotator cuff tears has a poorer outcome and a higher rate of failure compared with repairs of supraspinatus tears. In this prospective cohort study 28 consecutive patients with an irreparable posterosuperior rotator cuff tear after failed conservative or surgical treatment underwent teres major tendon transfer. Their mean age was 60 years (48 to 71) and the mean follow-up was 25 months (12 to 80). The mean active abduction improved from 79° (0° to 150°) pre-operatively to 105° (20° to 180°) post-operatively (p = 0.011). The mean active external rotation in 90° abduction improved from 25° (0° to 70°) pre-operatively to 55° (0° to 90°) post-operatively (p < 0.001). The mean Constant score improved from 43 (18 to 78) pre-operatively to 65 (30 to 86) post-operatively (p < 0.001). The median post-operative VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to 5 (0 to 56) post-operatively (p < 0.001). In conclusion, teres major transfer effectively restores function and relieves pain in patients with irreparable posterosuperior rotator cuff tears and leads to an overall clinical improvement in a relatively young and active patient group with limited treatment options. Cite this article: Bone Joint J 2013;95-B:523–9


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 486 - 489
1 Apr 2007
Bassi RS Simmons D Ali F Nuttall D Birch A Trail IA Stanley JK

The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function. No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other complications included three cases of ulnar neuropathy (8.3%) and one of deep infection (2.8%)