Advertisement for orthosearch.org.uk
Results 1 - 20 of 252
Results per page:
Bone & Joint Open
Vol. 2, Issue 2 | Pages 111 - 118
8 Feb 2021
Pettit M Shukla S Zhang J Sunil Kumar KH Khanduja V

Aims. The ongoing COVID-19 pandemic has disrupted and delayed medical and surgical examinations where attendance is required in person. Our article aims to outline the validity of online assessment, the range of benefits to both candidate and assessor, and the challenges to its implementation. In addition, we propose pragmatic suggestions for its introduction into medical assessment. Methods. We reviewed the literature concerning the present status of online medical and surgical assessment to establish the perceived benefits, limitations, and potential problems with this method of assessment. Results. Global experience with online, remote virtual examination has been largely successful with many benefits conferred to the trainee, and both an economic and logistical advantage conferred to the assessor or organization. Advances in online examination software and remote proctoring are overcoming practical caveats including candidate authentication, cheating prevention, cybersecurity, and IT failure. Conclusion. Virtual assessment provides benefits to both trainee and assessor in medical and surgical examinations and may also result in cost savings. Virtual assessment is likely to be increasingly used in the post-COVID world and we present recommendations for the continued adoption of virtual examination. It is, however, currently unable to completely replace clinical assessment of trainees. Cite this article: Bone Jt Open 2021;2(2):111–118


Bone & Joint Open
Vol. 2, Issue 6 | Pages 405 - 410
18 Jun 2021
Yedulla NR Montgomery ZA Koolmees DS Battista EB Day CS

Aims. The purpose of our study was to determine which groups of orthopaedic providers favour virtual care, and analyze overall orthopaedic provider perceptions of virtual care. We hypothesize that providers with less clinical experience will favour virtual care, and that orthopaedic providers overall will show increased preference for virtual care during the COVID-19 pandemic and decreased preference during non-pandemic circumstances. Methods. An orthopaedic research consortium at an academic medical system developed a survey examining provider perspectives regarding orthopaedic virtual care. Survey items were scored on a 1 to 5 Likert scale (1 = “strongly disagree”, 5 = “strongly agree”) and compared using nonparametric Mann-Whitney U test. Results. Providers with less experience were more likely to recommend virtual care for follow-up visits (3.61 on the Likert scale (SD 0.95) vs 2.90 (SD 1.23); p = 0.006) and feel that virtual care was essential to patient wellbeing (3.98 (SD 0.95) vs 3.00 (SD 1.16); p < 0.001) during the pandemic. Less experienced providers also viewed virtual visits as providing a similar level of care as in-person visits (2.41 (SD 1.02) vs 1.76 (SD 0.87); p = 0.006) and more time-efficient than in-person visits (3.07 (SD 1.19) vs 2.34 (SD 1.14); p = 0.012) in non-pandemic circumstances. During the pandemic, most providers viewed virtual care as effective in providing essential care (83.6%, n = 51) and wanted to schedule patients for virtual care follow-up (82.2%, n = 50); only 10.9% (n = 8) of providers preferred virtual visits in non-pandemic circumstances. Conclusion. Orthopaedic providers with less clinical experience seem to favourably view virtual care both during the pandemic and under non-pandemic circumstances. Providers in general appear to view virtual care positively during the pandemic but are less accommodating towards it in non-pandemic circumstances. Cite this article: Bone Jt Open 2021;2(6):405–410


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1170 - 1175
1 Sep 2012
Palan J Roberts V Bloch B Kulkarni A Bhowal B Dias J

The use of journal clubs and, more recently, case-based discussions in order to stimulate debate among orthopaedic surgeons lies at the heart of orthopaedic training and education. A virtual learning environment can be used as a platform to host virtual journal clubs and case-based discussions. This has many advantages in the current climate of constrained time and diminishing trainee and consultant participation in such activities. The virtual environment model opens up participation and improves access to journal clubs and case-based discussions, provides reusable educational content, establishes an electronic record of participation for individuals, makes use of multimedia material (including clinical imaging and photographs) for discussion, and finally, allows participants to link case-based discussions with relevant papers in the journal club. The Leicester experience highlights the many advantages and some of the potential difficulties in setting up such a virtual system and provides useful guidance for those considering such a system in their own training programme. As a result of the virtual learning environment, trainee participation has increased and there is a trend for increased consultant input in the virtual journal club and case-based discussions. It is likely that the use of virtual environments will expand to encompass newer technological approaches to personal learning and professional development


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 709 - 714
1 Jun 2022
Stirling PHC Simpson CJ Ring D Duckworth AD McEachan JE

Aims. The aim of this study was to describe the introduction of a virtual pathway for the management of patients with a suspected fracture of the scaphoid, and to report patient-reported outcome measures (PROMs) and satisfaction following treatment using this service. Methods. All adult patients who presented with a clinically suspected scaphoid fracture that was not visible on radiographs at the time of presentation during a one-year period were eligible for inclusion in the pathway. Demographic details, findings on examination, and routine four-view radiographs at the time of presentation were collected. All radiographs were reviewed virtually by a single consultant hand surgeon, with patient-initiated follow-up on request. PROMs were assessed at a minimum of one year after presentation and included the abbreviated version of the Disabilities of the Arm, Shoulder and Hand Score (QuickDASH), the EuroQol five-dimension five-level health questionnaire (EQ-5D-5L), the Net Promoter Score (NPS), and return to work. Results. A total of 221 patients were referred to the virtual pathway. Their mean age was 41 years (range 16 to 87) and there were 99 male patients (45%). A total of 189 patients (86%) were discharged with advice and 19 (9%) were recalled for clinical review: seven with an undisplaced scaphoid fracture, six with another fracture of the hand or wrist, two with a scapholunate ligament injury, and four in whom no abnormality was detected. A total of 13 patients (6%) initiated follow-up with the hand service: no fracture or ligament injury was identified in this group. PROMs were available for 179 patients (81%) at a mean follow-up of 19 months (range 13 to 33). The median QuickDASH score was 2.3 (interquartile range (IQR) 0 to 15.9), the median EQ-5D-5L was 0.85 (IQR 0.73 to 1.00), the NPS was 76, and 173 patients (97%) were satisfied with their treatment. There were no documented cases of symptomatic nonunion one year following injury. Conclusion. We describe the introduction of a virtual pathway for the management of patients with a suspected scaphoid fracture. We found high levels of patient satisfaction, excellent PROMs, and no detrimental effects in the vast majority of cases. Cite this article: Bone Joint J 2022;104-B(6):709–714


Bone & Joint Open
Vol. 2, Issue 5 | Pages 301 - 304
17 May 2021
Lee G Clough OT Hayter E Morris J Ashdown T Hardman J Anakwe R

The response to the COVID-19 pandemic has raised the profile and level of interest in the use, acceptability, safety, and effectiveness of virtual outpatient consultations and telemedicine. These models of care are not new but a number of challenges have so far hindered widespread take-up and endorsement of these ways of working. With the response to the COVID-19 pandemic, remote and virtual working and consultation have become the default. This paper explores our experience of and learning from virtual and remote consultation and questions how this experience can be retained and developed for the future. Cite this article: Bone Jt Open 2021;2(5):301–304


Bone & Joint Open
Vol. 1, Issue 6 | Pages 272 - 280
19 Jun 2020
King D Emara AK Ng MK Evans PJ Estes K Spindler KP Mroz T Patterson BM Krebs VE Pinney S Piuzzi NS Schaffer JL

Virtual encounters have experienced an exponential rise amid the current COVID-19 crisis. This abrupt change, seen in response to unprecedented medical and environmental challenges, has been forced upon the orthopaedic community. However, such changes to adopting virtual care and technology were already in the evolution forecast, albeit in an unpredictable timetable impeded by regulatory and financial barriers. This adoption is not meant to replace, but rather augment established, traditional models of care while ensuring patient/provider safety, especially during the pandemic. While our department, like those of other institutions, has performed virtual care for several years, it represented a small fraction of daily care. The pandemic required an accelerated and comprehensive approach to the new reality. Contemporary literature has already shown equivalent safety and patient satisfaction, as well as superior efficiency and reduced expenses with musculoskeletal virtual care (MSKVC) versus traditional models. Nevertheless, current literature detailing operational models of MSKVC is scarce. The current review describes our pre-pandemic MSKVC model and the shift to a MSKVC pandemic workflow that enumerates the conceptual workflow organization (patient triage, from timely care provision based on symptom acuity/severity to a continuum that includes future follow-up). Furthermore, specific setup requirements (both resource/personnel requirements such as hardware, software, and network connectivity requirements, and patient/provider characteristics respectively), and professional expectations are outlined. MSKVC has already become a pivotal element of musculoskeletal care, due to COVID-19, and these changes are confidently here to stay. Readiness to adapt and evolve will be required of individual musculoskeletal clinical teams as well as organizations, as established paradigms evolve. Cite this article: Bone Joint Open 2020;1-6:272–280


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 951 - 959
1 Aug 2019
Preston N McHugh GA Hensor EMA Grainger AJ O’Connor PJ Conaghan PG Stone MH Kingsbury SR

Aims. This study aimed to develop a virtual clinic for the purpose of reducing face-to-face orthopaedic consultations. Patients and Methods. Anonymized experts (hip and knee arthroplasty patients, surgeons, physiotherapists, radiologists, and arthroplasty practitioners) gave feedback via a Delphi Consensus Technique. This consisted of an iterative sequence of online surveys, during which virtual documents, made up of a patient-reported questionnaire, standardized radiology report, and decision-guiding algorithm, were modified until consensus was achieved. We tested the patient-reported questionnaire on seven patients in orthopaedic clinics using a ‘think-aloud’ process to capture difficulties with its completion. Results. A patient-reported 13-item questionnaire was developed covering pain, mobility, and activity. The radiology report included up to ten items (e.g. progressive periprosthetic bone loss) depending on the type of arthroplasty. The algorithm concludes in one of three outcomes: review at surgeon’s discretion (three to 12 months); see at next available clinic; or long-term follow-up/discharge. Conclusion. The virtual clinic approach with attendant documents achieved consensus by orthopaedic experts, radiologists, and patients. The robust development and testing of this standardized virtual clinic provided a sound platform for organizations in the United Kingdom to adopt a virtual clinic approach for follow-up of hip and knee arthroplasty patients. Cite this article: Bone Joint J 2019;101-B:951–959


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 74 - 81
1 May 2024
Callary SA Broekhuis D Barends J Ramasamy B Nelissen RGHH Solomon LB Kaptein BL

Aims. The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) – the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) – using virtual modelling. Methods. Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. Results. The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm. 3. (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm. 3. (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm. 2. (IQR 28.2 to 82.3) vs 56.6 cm. 2. (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm. 2. (IQR 28.2 to 72.4) vs 25.5 cm. 2. (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm. 2. (IQR 0 to 13.1) vs 23.2 cm. 2. (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. Conclusion. In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms. Cite this article: Bone Joint J 2024;106-B(5 Supple B):74–81


Bone & Joint Open
Vol. 1, Issue 11 | Pages 683 - 690
1 Nov 2020
Khan SA Asokan A Handford C Logan P Moores T

Background. Due to the overwhelming demand for trauma services, resulting from increasing emergency department attendances over the past decade, virtual fracture clinics (VFCs) have become the fashion to keep up with the demand and help comply with the BOA Standards for Trauma and Orthopaedics (BOAST) guidelines. In this article, we perform a systematic review asking, “How useful are VFCs?”, and what injuries and conditions can be treated safely and effectively, to help decrease patient face to face consultations. Our primary outcomes were patient satisfaction, clinical efficiency and cost analysis, and clinical outcomes. Methods. We performed a systematic literature search of all papers pertaining to VFCs, using the search engines PubMed, MEDLINE, and the Cochrane Database, according to the Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA) checklist. Searches were carried out and screened by two authors, with final study eligibility confirmed by the senior author. Results. In total, 21 records were relevant to our research question. Six orthopaedic injuries were identified as suitable for VFC review, with a further four discussed in detail. A reduction of face to face appointments of up to 50% was reported with greater compliance to BOAST guidelines (46.4%) and cost saving (up to £212,000). Conclusions. This systematic review demonstrates that the VFC model can help deliver a safe, more cost-effective, and more efficient arm of the trauma service to patients. Cite this article: Bone Joint Open 2020;1-11:683–690


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 728 - 734
1 Jul 2024
Poppelaars MA van der Water L Koenraadt-van Oost I Boele van Hensbroek P van Bergen CJA

Aims. Paediatric fractures are highly prevalent and are most often treated with plaster. The application and removal of plaster is often an anxiety-inducing experience for children. Decreasing the anxiety level may improve the patients’ satisfaction and the quality of healthcare. Virtual reality (VR) has proven to effectively distract children and reduce their anxiety in other clinical settings, and it seems to have a similar effect during plaster treatment. This study aims to further investigate the effect of VR on the anxiety level of children with fractures who undergo plaster removal or replacement in the plaster room. Methods. A randomized controlled trial was conducted. A total of 255 patients were included, aged five to 17 years, who needed plaster treatment for a fracture of the upper or lower limb. Randomization was stratified for age (five to 11 and 12 to 17 years). The intervention group was distracted with VR goggles and headphones during the plaster treatment, whereas the control group received standard care. As the primary outcome, the post-procedural level of anxiety was measured with the Child Fear Scale (CFS). Secondary outcomes included the children’s anxiety reduction (difference between CFS after and CFS before plaster procedure), numerical rating scale (NRS) pain, NRS satisfaction of the children and accompanying parents/guardians, and the children’s heart rates during the procedure. An independent-samples t-test and Mann-Whitney U test (depending on the data distribution) were used to analyze the data. Results. The post-procedural CFS was significantly lower (p < 0.001) in the intervention group (proportion of children with no anxiety = 78.6%) than in the control group (56.8%). The anxiety reduction, NRS pain and satisfaction scores, and heart rates showed no significant differences between the control group and the intervention group. Subanalyses showed an increased effect of VR on anxiety levels in young patients, females, upper limb fractures, and those who had had previous plaster treatment. Conclusion. VR effectively reduces the anxiety levels of children in the plaster room, especially in young girls. No statistically significant effects were seen regarding pain, heart rate, or satisfaction scores. Cite this article: Bone Joint J 2024;106-B(7):728–734


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 559 - 565
1 May 2018
Bartlett JD Lawrence JE Stewart ME Nakano N Khanduja V

Aims. The aim of this study was to assess the current evidence relating to the benefits of virtual reality (VR) simulation in orthopaedic surgical training, and to identify areas of future research. Materials and Methods. A literature search using the MEDLINE, Embase, and Google Scholar databases was performed. The results’ titles, abstracts, and references were examined for relevance. Results. A total of 31 articles published between 2004 and 2016 and relating to the objective validity and efficacy of specific virtual reality orthopaedic surgical simulators were identified. We found 18 studies demonstrating the construct validity of 16 different orthopaedic virtual reality simulators by comparing expert and novice performance. Eight studies have demonstrated skill acquisition on a simulator by showing improvements in performance with repeated use. A further five studies have demonstrated measurable improvements in operating theatre performance following a period of virtual reality simulator training. Conclusion. The demonstration of ‘real-world’ benefits from the use of VR simulation in knee and shoulder arthroscopy is promising. However, evidence supporting its utility in other forms of orthopaedic surgery is lacking. Further studies of validity and utility should be combined with robust analyses of the cost efficiency of validated simulators to justify the financial investment required for their use in orthopaedic training. Cite this article: Bone Joint J 2018;100-B:559–65


Bone & Joint Research
Vol. 6, Issue 5 | Pages 259 - 269
1 May 2017
McKirdy A Imbuldeniya AM

Objectives. To assess the clinical and cost-effectiveness of a virtual fracture clinic (VFC) model, and supplement the literature regarding this service as recommended by The National Institute for Health and Care Excellence (NICE) and the British Orthopaedic Association (BOA). Methods. This was a retrospective study including all patients (17 116) referred to fracture clinics in a London District General Hospital from May 2013 to April 2016, using hospital-level data. We used interrupted time series analysis with segmented regression, and direct before-and-after comparison, to study the impact of VFCs introduced in December 2014 on six clinical parameters and on local Clinical Commissioning Group (CCG) spend. Student’s t-tests were used for direct comparison, whilst segmented regression was employed for projection analysis. Results. There were statistically significant reductions in numbers of new patients seen face-to-face (140.4, . sd. 39.6 versus 461.6, . sd. 61.63, p < 0.0001), days to first orthopaedic review (5.2, . sd. 0.66 versus 10.9, . sd. 1.5, p < 0.0001), discharges (33.5, . sd. 3.66 versus 129.2, . sd. 7.36, p < 0.0001) and non-attendees (14.82, . sd. 1.48 versus 60.47, . sd. 2.68, p < 0.0001), in addition to a statistically significant increase in number of patients seen within 72-hours (46.4% 3873 of 8345 versus 5.1% 447 of 8771, p < 0.0001). There was a non-significant increase in consultation time of 1 minute 9 seconds (14 minutes 53 seconds . sd. 106 seconds versus 13 minutes 44 seconds . sd. 128 seconds, p = 0.0878). VFC saved the local CCG £67 385.67 in the first year and is set to save £129 885.67 annually thereafter. Conclusions. We have shown VFCs are clinically and cost-effective, with improvement across several clinical performance parameters and substantial financial savings for CCGs. To our knowledge this is the largest study addressing clinical practice implications of VFCs in England, using robust methodology to adjust for pre-existing trends. Further studies are required to appreciate whether our results are reproducible with local variations in the VFC model and payment tariffs. Cite this article: A. McKirdy, A. M. Imbuldeniya. The clinical and cost effectiveness of a virtual fracture clinic service: An interrupted time series analysis and before-and-after comparison. Bone Joint Res 2017;6:–269. DOI: 10.1302/2046-3758.65.BJR-2017-0330.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1520 - 1523
1 Nov 2005
Attias N Lindsey RW Starr AJ Borer D Bridges K Hipp JA

We created virtual three-dimensional reconstruction models from computed tomography scans obtained from patients with acetabular fractures. Virtual cylindrical implants were placed intraosseously in the anterior column, the posterior column and across the dome of the acetabulum. The maximum diameter which was entirely contained within the bone was determined for each position of the screw. In the same model, the cross-sectional diameters of the columns were measured and compared to the maximum diameter of the corresponding virtual implant. We found that the mean maximum diameter of virtual implant accommodated by the anterior columns was 6.4 mm and that the smallest diameter of the columns was larger than the maximum diameter of the equivalent virtual implant. This study suggests that the size of the screw used for percutaneous fixation of acetabular fractures should not be based solely on the measurement of cross-sectional diameter and that virtual three-dimensional reconstructions might be useful in pre-operative planning


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1104 - 1109
1 Oct 2022
Hansjee S Giebaly DE Shaarani SR Haddad FS

We aim to explore the potential technologies for monitoring and assessment of patients undergoing arthroplasty by examining selected literature focusing on the technology currently available and reflecting on possible future development and application. The reviewed literature indicates a large variety of different hardware and software, widely available and used in a limited manner, to assess patients’ performance. There are extensive opportunities to enhance and integrate the systems which are already in existence to develop patient-specific pathways for rehabilitation.

Cite this article: Bone Joint J 2022;104-B(10):1104–1109.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1585 - 1592
1 Dec 2019
Logishetty K Rudran B Cobb JP

Aims. Arthroplasty skills need to be acquired safely during training, yet operative experience is increasingly hard to acquire by trainees. Virtual reality (VR) training using headsets and motion-tracked controllers can simulate complex open procedures in a fully immersive operating theatre. The present study aimed to determine if trainees trained using VR perform better than those using conventional preparation for performing total hip arthroplasty (THA). Patients and Methods. A total of 24 surgical trainees (seven female, 17 male; mean age 29 years (28 to 31)) volunteered to participate in this observer-blinded 1:1 randomized controlled trial. They had no prior experience of anterior approach THA. Of these 24 trainees, 12 completed a six-week VR training programme in a simulation laboratory, while the other 12 received only conventional preparatory materials for learning THA. All trainees then performed a cadaveric THA, assessed independently by two hip surgeons. The primary outcome was technical and non-technical surgical performance measured by a THA-specific procedure-based assessment (PBA). Secondary outcomes were step completion measured by a task-specific checklist, error in acetabular component orientation, and procedure duration. Results. VR-trained surgeons performed at a higher level than controls, with a median PBA of Level 3a (procedure performed with minimal guidance or intervention) versus Level 2a (guidance required for most/all of the procedure or part performed). VR-trained surgeons completed 33% more key steps than controls (mean 22 (. sd. 3) vs 12 (. sd. 3)), were 12° more accurate in component orientation (mean error 4° (. sd. 6°) vs 16° (. sd. 17°)), and were 18% faster (mean 42 minutes (. sd. 7) vs 51 minutes (. sd. 9)). Conclusion. Procedural knowledge and psychomotor skills for THA learned in VR were transferred to cadaveric performance. Basic preparatory materials had limited value for trainees learning a new technique. VR training advanced trainees further up the learning curve, enabling highly precise component orientation and more efficient surgery. VR could augment traditional surgical training to improve how surgeons learn complex open procedures. Cite this article: Bone Joint J 2019;101-B:1585–1592


Bone & Joint Open
Vol. 2, Issue 3 | Pages 211 - 215
1 Mar 2021
Ng ZH Downie S Makaram NS Kolhe SN Mackenzie SP Clement ND Duckworth AD White TO

Aims. Virtual fracture clinics (VFCs) are advocated by recent British Orthopaedic Association Standards for Trauma and Orthopaedics (BOASTs) to efficiently manage injuries during the COVID-19 pandemic. The primary aim of this national study is to assess the impact of these standards on patient satisfaction and clinical outcome amid the pandemic. The secondary aims are to determine the impact of the pandemic on the demographic details of injuries presenting to the VFC, and to compare outcomes and satisfaction when the BOAST guidelines were first introduced with a subsequent period when local practice would be familiar with these guidelines. Methods. This is a national cross-sectional cohort study comprising centres with VFC services across the UK. All consecutive adult patients assessed in VFC in a two-week period pre-lockdown (6 May 2019 to 19 May 2019) and in the same two-week period at the peak of the first lockdown (4 May 2020 to 17 May 2020), and a randomly selected sample during the ‘second wave’ (October 2020) will be eligible for the study. Data comprising local VFC practice, patient and injury characteristics, unplanned re-attendances, and complications will be collected by local investigators for all time periods. A telephone questionnaire will be used to determine patient satisfaction and patient-reported outcomes for patients who were discharged following VFC assessment without face-to-face consultation. Ethics and dissemination. The study results will identify changes in case-mix and numbers of patients managed through VFCs and whether this is safe and associated with patient satisfaction. These data will provide key information for future expert-led consensus on management of trauma injuries through the VFC. The protocol will be disseminated through conferences and peer-reviewed publication. This protocol has been reviewed by the South East Scotland Research Ethics Service and is classified as a multicentre audit. Cite this article: Bone Jt Open 2021;2(3):211–215


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 153 - 158
1 Nov 2013
Victor J Premanathan A

We have investigated the benefits of patient specific instrument guides, applied to osteotomies around the knee. Single, dual and triple planar osteotomies were performed on tibias or femurs in 14 subjects. In all patients, a detailed pre-operative plan was prepared based upon full leg standing radiographic and CT scan information. The planned level of the osteotomy and open wedge resection was relayed to the surgery by virtue of a patient specific guide developed from the images. The mean deviation between the planned wedge angle and the executed wedge angle was 0° (-1 to 1, sd 0.71) in the coronal plane and 0.3° (-0.9 to 3, sd 1.14) in the sagittal plane. The mean deviation between the planned hip, knee, ankle angle (HKA) on full leg standing radiograph and the post-operative HKA was 0.3° (-1 to 2, sd 0.75). It is concluded that this is a feasible and valuable concept from the standpoint of pre-operative software based planning, surgical application and geometrical accuracy of outcome.

Cite this article: Bone Joint J 2013;95-B, Supple A:153–8.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 843 - 849
1 Aug 2023
Grandhi TSP Fontalis A Raj RD Kim WJ Giebaly DE Haddad FS

Telehealth has the potential to change the way we approach patient care. From virtual consenting to reducing carbon emissions, costs, and waiting times, it is a powerful tool in our clinical armamentarium. There is mounting evidence that remote diagnostic evaluation and decision-making have reached an acceptable level of accuracy and can safely be adopted in orthopaedic surgery. Furthermore, patients’ and surgeons’ satisfaction with virtual appointments are comparable to in-person consultations. Challenges to the widespread use of telehealth should, however, be acknowledged and include the cost of installation, training, maintenance, and accessibility. It is also vital that clinicians are conscious of the medicolegal and ethical considerations surrounding the medium and adhere strictly to the relevant data protection legislation and storage framework. It remains to be seen how organizations harness the full spectrum of the technology to facilitate effective patient care. Cite this article: Bone Joint J 2023;105-B(8):843–849


Bone & Joint Open
Vol. 5, Issue 8 | Pages 628 - 636
2 Aug 2024
Eachempati KK Parameswaran A Ponnala VK Sunil A Sheth NP

Aims. The aims of this study were: 1) to describe extended restricted kinematic alignment (E-rKA), a novel alignment strategy during robotic-assisted total knee arthroplasty (RA-TKA); 2) to compare residual medial compartment tightness following virtual surgical planning during RA-TKA using mechanical alignment (MA) and E-rKA, in the same set of osteoarthritic varus knees; 3) to assess the requirement of soft-tissue releases during RA-TKA using E-rKA; and 4) to compare the accuracy of surgical plan execution between knees managed with adjustments in component positioning alone, and those which require additional soft-tissue releases. Methods. Patients who underwent RA-TKA between January and December 2022 for primary varus osteoarthritis were included. Safe boundaries for E-rKA were defined. Residual medial compartment tightness was compared following virtual surgical planning using E-rKA and MA, in the same set of knees. Soft-tissue releases were documented. Errors in postoperative alignment in relation to planned alignment were compared between patients who did (group A) and did not (group B) require soft-tissue releases. Results. The use of E-rKA helped restore all knees within the predefined boundaries, with appropriate soft-tissue balancing. E-rKA compared with MA resulted in reduced residual medial tightness following surgical planning, in full extension (2.71 mm (SD 1.66) vs 5.16 mm (SD 3.10), respectively; p < 0.001), and 90° of flexion (2.52 mm (SD 1.63) vs 6.27 mm (SD 3.11), respectively; p < 0.001). Among the study population, 156 patients (78%) were managed with minor adjustments in component positioning alone, while 44 (22%) required additional soft-tissue releases. The mean errors in postoperative alignment were 0.53 mm and 0.26 mm among patients in group A and group B, respectively (p = 0.328). Conclusion. E-rKA is an effective and reproducible alignment strategy during RA-TKA, permitting a large proportion of patients to be managed without soft-tissue releases. The execution of minor alterations in component positioning within predefined multiplanar boundaries is a better starting point for gap management than soft-tissue releases. Cite this article: Bone Jt Open 2024;5(8):628–636


Bone & Joint Open
Vol. 3, Issue 5 | Pages 423 - 431
1 May 2022
Leong JWY Singhal R Whitehouse MR Howell JR Hamer A Khanduja V Board TN

Aims. The aim of this modified Delphi process was to create a structured Revision Hip Complexity Classification (RHCC) which can be used as a tool to help direct multidisciplinary team (MDT) discussions of complex cases in local or regional revision networks. Methods. The RHCC was developed with the help of a steering group and an invitation through the British Hip Society (BHS) to members to apply, forming an expert panel of 35. We ran a mixed-method modified Delphi process (three rounds of questionnaires and one virtual meeting). Round 1 consisted of identifying the factors that govern the decision-making and complexities, with weighting given to factors considered most important by experts. Participants were asked to identify classification systems where relevant. Rounds 2 and 3 focused on grouping each factor into H1, H2, or H3, creating a hierarchy of complexity. This was followed by a virtual meeting in an attempt to achieve consensus on the factors which had not achieved consensus in preceding rounds. Results. The expert group achieved strong consensus in 32 out of 36 factors following the Delphi process. The RHCC used the existing Paprosky (acetabulum and femur), Unified Classification System, and American Society of Anesthesiologists (ASA) classification systems. Patients with ASA grade III/IV are recognized with a qualifier of an asterisk added to the final classification. The classification has good intraobserver and interobserver reliability with Kappa values of 0.88 to 0.92 and 0.77 to 0.85, respectively. Conclusion. The RHCC has been developed through a modified Delphi technique. RHCC will provide a framework to allow discussion of complex cases as part of a local or regional hip revision MDT. We believe that adoption of the RHCC will provide a comprehensive and reproducible method to describe each patient’s case with regard to surgical complexity, in addition to medical comorbidities that may influence their management. Cite this article: Bone Jt Open 2022;3(5):423–431