Advertisement for orthosearch.org.uk
Results 1 - 20 of 111
Results per page:
Bone & Joint Research
Vol. 12, Issue 8 | Pages 504 - 511
23 Aug 2023
Wang C Liu S Chang C

Aims. This study aimed to establish the optimal fixation methods for calcaneal tuberosity avulsion fractures with different fragment thicknesses in a porcine model. Methods. A total of 36 porcine calcanea were sawed to create simple avulsion fractures with three different fragment thicknesses (5, 10, and 15 mm). They were randomly fixed with either two suture anchors or one headless screw. Load-to-failure and cyclic loading tension tests were performed for the biomechanical analysis. Results. This biomechanical study predicts that headless screw fixation is a better option if fragment thickness is over 15 mm in terms of the comparable peak failure load to suture anchor fixation (headless screw: 432.55 N (SD 62.25); suture anchor: 446.58 N (SD 84.97)), and less fracture fragment displacement after cyclic loading (headless screw: 3.94 N (SD 1.76); suture anchor: 8.68 N (SD 1.84)). Given that the fragment thickness is less than 10 mm, suture anchor fixation is a safer option. Conclusion. Fracture fragment thickness helps in making the decision of either using headless screw or suture anchor fixation in treating calcaneal tuberosity avulsion fracture, based on the regression models of our study. Cite this article: Bone Joint Res 2023;12(8):504–511


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1506 - 1511
1 Dec 2019
Kim SH Yang SH Rhee S Lee KJ Kim HS Oh JH

Aims

The aim of this study was to compare the osseous reactions elicited by all-suture, polyetheretherketone (PEEK), and two different biodegradable anchors used during rotator cuff repair.

Patients and Methods

Transosseous-equivalent rotator cuff repair was performed in 73 patients. The patients were divided into two groups, in both of which two different medial-row anchors were used. In group 1, anchor A comprised 30% β-tricalcium phosphate (TCP) + 70% fast-absorbing poly lactic-co-glycolic acid copolymer (85% polylactic acid enantiomers + 15% polyglycolic acid) and anchor B comprised all-sutures. In group 2, anchor C comprised 23% micro β-TCP + 77% polylactic acid enantiomers and anchor D comprised PEEK polymer. There were 37 patients in group 1 and 36 patients in group 2. The presence and severity of fluid collection around anchors and healing of the rotator cuff were assessed using MRI scans, approximately one year postoperatively. The severity of the collection was graded as 0 (no perianchor fluid signal), 1 (minimal perianchor fluid), 2 (local collection of fluid), 3 (fluid collection around the whole length of the anchor but of a diameter less than twice the anchor diameter), or 4 (fluid collection around the whole length of the anchor and of a diameter greater than twice the anchor diameter).


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1141 - 1149
1 Oct 2024
Saleem J Rawi B Arnander M Pearse E Tennent D

Aims

Extensive literature exists relating to the management of shoulder instability, with a more recent focus on glenoid and humeral bone loss. However, the optimal timing for surgery following a dislocation remains unclear. There is concern that recurrent dislocations may worsen subsequent surgical outcomes, with some advocating stabilization after the first dislocation. The aim of this study was to determine if the recurrence of instability following arthroscopic stabilization in patients without significant glenoid bone loss was influenced by the number of dislocations prior to surgery.

Methods

A systematic review and meta-analysis was performed using the PubMed, EMBASE, Orthosearch, and Cochrane databases with the following search terms: ((shoulder or glenohumeral) and (dislocation or subluxation) and arthroscopic and (Bankart or stabilisation or stabilization) and (redislocation or re-dislocation or recurrence or instability)). Methodology followed the PRISMA guidelines. Data and outcomes were synthesized by two independent reviewers, and papers were assessed for bias and quality.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1386 - 1391
1 Oct 2008
Ozbaydar M Elhassan B Esenyel C Atalar A Bozdag E Sunbuloglu E Kopuz N Demirhan M

We compared time-dependent changes in the biomechanical properties of single-and double-row repair of a simulated acute tear of the rotator cuff in rabbits to determine the effect of the fixation techniques on the healing process. A tear of the supraspinatus tendon was created in 80 rabbits which were separated into two equal groups. A single-row repair with two suture anchors was conducted in group 1 and a double-row repair with four suture anchors in group 2. A total of ten intact contralateral shoulder joints was used as a control group. Biomechanical testing was performed immediately post-operatively and at four and eight weeks, and histological analysis at four and eight weeks. The mean load to failure in group 2 animals was greater than in group 1, but both groups remained lower than the control group at all intervals. Histological analysis showed similar healing properties at four and eight weeks in both groups, but a significantly larger number of healed tendon-bone interfaces were identified in group 2 than in group 1 at eight weeks (p < 0.012). The ultimate load to failure increased with the number of suture anchors used immediately post-operatively, and at four and eight weeks. The increased load to failure at eight weeks seemed to be related to the increase in the surface area of healed tendon-to-bone in the double-row repair group


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 458 - 461
1 May 1997
Rossouw DJ McElroy BJ Amis AA Emery RJH

Repair of the rotator cuff requires secure reattachment, but large chronic defects cause osteoporosis of the greater tuberosity which may then have insufficient strength to allow proper fixation of the tendon. Recently, suture anchors have been introduced, but have not been fully evaluated. We have investigated the strength of suture-to-anchor attachment, and the use of suture anchors in repairs of the rotator cuff either to the greater tuberosity or the lateral cortex of the humerus. The second method gave a significant increase in the strength of the repair (p = 0.014). The repairs were loaded cyclically and failed at low loads by cutting into bone and tendon, casting doubt on the integrity of the repair in early mobilisation after surgery. Repairs with suture anchors did not perform better than those with conventional transosseous attachment


Bone & Joint 360
Vol. 2, Issue 1 | Pages 25 - 27
1 Feb 2013

The February 2013 Shoulder & Elbow Roundup. 360 . looks at: whether we should replace fractured shoulders; the limited evidence for shoulder fractures; cuffs and early physio; matrix proteins and cuff tears; long-term SLAP tear outcomes; suture anchors; recurrent Bankart repairs; and acromial morphology and calcific tendonitis


Bone & Joint Research
Vol. 5, Issue 6 | Pages 269 - 275
1 Jun 2016
Ono Y Woodmass JM Nelson AA Boorman RS Thornton GM Lo IKY

Objectives. This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods. Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results. In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions. Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269–275. DOI: 10.1302/2046-3758.56.2000535


Bone & Joint 360
Vol. 1, Issue 5 | Pages 19 - 21
1 Oct 2012

The October 2012 Shoulder & Elbow Roundup. 360. looks at: fast-absorbing suture anchors for use in shoulder labral tears; double-row rotator cuff repair; degenerate massive rotator cuff tears addressed with partial repair; open and arthroscopic stabilisation of Bankart lesions; predicting the risk of revision humeral head replacement; arthroscopic treatment for frozen shoulder; and long-term follow-up of the Bristow-Latarjet procedure


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1188 - 1196
1 Sep 2007
Hobby J Griffin D Dunbar M Boileau P

A systematic search of the literature published between January 1985 and February 2006 identified 62 studies which reported the results of arthroscopic procedures for chronic anterior shoulder instability or comparisons between arthroscopic and open surgery. These studies were classified by surgical technique and research methodology, and when appropriate, were included in a meta-analysis. The failure rate of arthroscopic shoulder stabilisation using staples or transglenoid suture techniques appeared to be significantly higher than that of either open surgery or arthroscopic stabilisation using suture anchors or bio-absorbable tacks. Arthroscopic anterior stabilisation using the most effective techniques has a similar rate of failure to open stabilisation after two years


Bone & Joint 360
Vol. 2, Issue 3 | Pages 27 - 29
1 Jun 2013

The June 2013 Shoulder & Elbow Roundup. 360 . looks at: whether suture anchors are still the gold standard; infection and revision elbow arthroplasty; the variable success of elbow replacements; sliding knots; neurologic cuff pain and the suprascapular nerve; lies, damn lies and statistics; osteoarthritis; and one- or two-stage treatment for the infected shoulder revision


Bone & Joint Research
Vol. 6, Issue 2 | Pages 82 - 89
1 Feb 2017
Nagra NS Zargar N Smith RDJ Carr AJ

Objectives. All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors. Materials and Methods. A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05. Results. Overall, mean maximum tensile strength values were significantly higher for the traditional anchor (181.0 N, standard error (. se). 17.6) compared with the all-suture anchors (mean 133.1 N . se. 16.7) (p = 0.04). The JuggerKnot anchor had greatest displacement at 50, 100 and 150 cycles, and at failure, reaching statistical significance over the control at 100 and 150 cycles (22.6 mm . se. 2.5 versus 12.5 mm . se. 0.3; and 29.6 mm . se. 4.8 versus 17.0 mm . se. 0.7). Every all-suture anchor tested showed substantial (> 5 mm) displacement between 50 and 100 cycles (6.2 to 14.3). All-suture anchors predominantly failed due to anchor pull-out (95% versus 25% of traditional anchors), whereas a higher proportion of traditional anchors failed secondary to suture breakage. Conclusion. We demonstrate decreased failure load, increased total displacement, and variable failure mechanisms in all-suture anchors, compared with traditional anchors designed for rotator cuff repair. These findings will aid the surgeon’s choice of implant, in the context of the clinical scenario. Cite this article: N. S. Nagra, N. Zargar, R. D. J. Smith, A. J. Carr. Mechanical properties of all-suture anchors for rotator cuff repair. Bone Joint Res 2017;6:82–89. DOI: 10.1302/2046-3758.62.BJR-2016-0225.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 103 - 106
1 Jan 2008
Kettler M Tingart MJ Lunger J Kuhn V

Operative fixation is the treatment of choice for a rupture of the distal tendon of biceps. A variety of techniques have been described including transosseous sutures and suture anchors. The poor quality of the bone of the radial tuberosity might affect the load to failure of the tendon repair in early rehabilitation. The aim of this study was to determine the loads to failure of different techniques of fixation and to investigate their association with the bone mineral density of the radial tuberosity. Peripheral quantitative computed tomography was carried out to measure the trabecular and cortical bone mineral density of the radial tuberosity in 40 cadaver specimens. The loads to failure in four different techniques of fixation were determined. The Endobutton-based method showed the highest failure load at 270 N (. sd. 22) (p < 0.05). The mean failure load of the transosseous suture technique was 210 N (. sd. 66) and that of the TwinFix-QuickT 5.0 mm was 57 N (. sd. 22), significantly lower than those of all other repairs (p < 0.05). No significant correlation was seen between bone mineral density and loads to failure. The transosseous technique is an easy and cost-saving procedure for fixation of the distal biceps tendon. TwinFix-QuickT 5.0 mm had significantly lower failure loads, which might affect early rehabilitation, particularly in older patients


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1470 - 1477
1 Nov 2007
Balg F Boileau P

There is no simple method available to identify patients who will develop recurrent instability after an arthroscopic Bankart procedure and who would be better served by an open operation. We carried out a prospective case-control study of 131 consecutive unselected patients with recurrent anterior shoulder instability who underwent this procedure using suture anchors. At follow-up after a mean of 31.2 months (24 to 52) 19 (14.5%) had recurrent instability. The following risk factors were identified: patient age under 20 years at the time of surgery; involvement in competitive or contact sports or those involving forced overhead activity; shoulder hyperlaxity; a Hill-Sachs lesion present on an anteroposterior radiograph of the shoulder in external rotation and/or loss of the sclerotic inferior glenoid contour. These factors were integrated in a 10-point pre-operative instability severity index score and tested retrospectively on the same population. Patients with a score over 6 points had an unacceptable recurrence risk of 70% (p < 0.001). On this basis we believe that an arthroscopic Bankart repair is contraindicated in these patients, to whom we now suggest a Bristow-Latarjet procedure instead


Bone & Joint 360
Vol. 12, Issue 6 | Pages 36 - 39
1 Dec 2023

The December 2023 Trauma Roundup360 looks at: Distal femoral arthroplasty: medical risks under the spotlight; Quads repair: tunnels or anchors?; Complex trade-offs in treating severe tibial fractures: limb salvage versus primary amputation; Middle-sized posterior malleolus fractures – to fix?; Bone transport through induced membrane: a randomized controlled trial; Displaced geriatric femoral neck fractures; Risk factors for reoperation to promote union in 1,111 distal femur fractures; New versus old – reliability of the OTA/AO classification for trochanteric hip fractures; Risk factors for fracture-related infection after ankle fracture surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1064 - 1068
1 Aug 2007
Berendes TD Wolterbeek R Pilot P Verburg H te Slaa RL

We report the outcome of a modified Bankart procedure using suture anchors in 31 patients (31 shoulders) with a mean follow-up of 11 years (10 to 15). The mean age of the patients was 28 years (16 to 39). At follow-up, the mean Rowe score was 90 points (66 to 98) and the Constant score was 96 points (85 to 100). A total of 26 shoulders (84%) had a good or excellent result. The rate of recurrence varied between 6.7% and 9.7% and depended on how recurrence was defined. Two patients had a significant new injury at one and nine years, respectively after operation. The overall rate of instability (including subluxations) varied between 12.9% and 22.6%. All patients returned to work, with 29 (94%) resuming their pre-operative occupation and level of activity. Mild radiological osteoarthritis was seen in nine shoulders (29%) and severe osteoarthritis in one. We conclude that the open modified Bankart procedure is a reliable surgical technique with good long-term results


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1244 - 1251
1 Dec 2023
Plastow R Raj RD Fontalis A Haddad FS

Injuries to the quadriceps muscle group are common in athletes performing high-speed running and kicking sports. The complex anatomy of the rectus femoris puts it at greatest risk of injury. There is variability in prognosis in the literature, with reinjury rates as high as 67% in the severe graded proximal tear. Studies have highlighted that athletes can reinjure after nonoperative management, and some benefit may be derived from surgical repair to restore function and return to sport (RTS). This injury is potentially career-threatening in the elite-level athlete, and we aim to highlight the key recent literature on interventions to restore strength and function to allow early RTS while reducing the risk of injury recurrence. This article reviews the optimal diagnostic strategies and classification of quadriceps injuries. We highlight the unique anatomy of each injury on MRI and the outcomes of both nonoperative and operative treatment, providing an evidence-based management framework for athletes.

Cite this article: Bone Joint J 2023;105-B(12):1244–1251.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 16 - 18
1 Feb 2024

The February 2024 Knee Roundup360 looks at: Do patients with hypoallergenic total knee arthroplasty implants for metal allergy do worse? An analysis of healthcare utilizations and patient-reported outcome measures; Defining a successful total knee arthroplasty; Incidence, microbiological studies, and factors associated with periprosthetic joint infection after total knee arthroplasty; A modified Delphi consensus statement on patellar instability; Cause for concern? Significant cement coverage in retrieved metaphyseal cones after revision total knee arthroplasty; Prevalence of post-traumatic osteoarthritis after anterior cruciate ligament injury remains high despite advances in surgical techniques; Cost-effectiveness of arthroscopic partial meniscectomy versus physical therapy for traumatic meniscal tears in patients aged under 45 years.


Bone & Joint 360
Vol. 13, Issue 5 | Pages 24 - 26
1 Oct 2024

The October 2024 Knee Roundup360 looks at: Managing the unexpected: treatment of intraoperative medial collateral ligament injuries; Identifying subgroups of patients that may benefit from robotic arm-assisted total knee arthroplasty: secondary analysis of data from a randomized controlled trial; Cost-effectiveness of enoxaparin versus aspirin in the prevention of venous thromboembolism after total hip or knee arthroplasty: an analysis from the CRISTAL cluster-randomized trial; Cartilage regeneration and long-term survival in medial knee osteoarthritis patients treated with high tibial osteotomy and osteochondral autologous transfer system; Treatment of chronic and complex meniscal tears with arthroscopic meniscus repair augmented with collagen matrix wrapping: failure rate and functional outcomes; Long-term outcomes of multiligament knee injuries in American football players.


Bone & Joint 360
Vol. 13, Issue 3 | Pages 24 - 27
3 Jun 2024

The June 2024 Foot & Ankle Roundup360 looks at: First MTPJ fusion in young versus old patients; Minimally invasive calcaneum Zadek osteotomy and the effect of sequential burr passes; Comparison between Achilles tendon reinsertion and dorsal closing wedge calcaneal osteotomy for the treatment of insertional Achilles tendinopathy; Revision ankle arthroplasty – is it worthwhile?; Tibiotalocalcaneal arthrodesis or below-knee amputation – salvage or sacrifice?; Fusion or replacement for hallux rigidus?.