Advertisement for orthosearch.org.uk
Results 1 - 20 of 30
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 668 - 671
1 May 2005
Lee PTH Clarke MT Bearcroft PWP Robinson AHN

We have assessed the proximal capsular extension of the ankle joint in 18 patients who had a contrast-enhanced MRI ankle arthrogram in order to delineate the capsular attachments. We noted consistent proximal capsular extensions anterior to the distal tibia and in the tibiofibular recess. The mean capsular extension anterior to the distal tibia was 9.6 mm (4.9 to 27.0) proximal to the anteroinferior tibial margin and 3.8 mm (−2.1 to 9.3) proximal to the dome of the tibial plafond. In the tibiofibular recess, the mean capsular extension was 19.2 mm (12.7 to 38.0) proximal to the anteroinferior tibial margin and 13.4 mm (5.8 to 20.5) proximal to the dome of the tibial plafond. These areas of proximal capsular extensions run the risk of being traversed during the insertion of finewires for the treatment of fractures of the distal tibia. Surgeons using these techniques should be aware of this anatomy in order to minimise the risk of septic arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 52 - 56
1 Jan 2011
Kocaoglu M Bilen FE Sen C Eralp L Balci HI

We present the results of the surgical correction of lower-limb deformities caused by metabolic bone disease. Our series consisted of 17 patients with a diagnosis of hypophosphataemic rickets and two with renal osteodystrophy; their mean age was 25.6 years (14 to 57). In all, 43 lower-limb segments (27 femora and 16 tibiae) were osteotomised and the deformity corrected using a monolateral external fixator. The segment was then stabilised with locked intramedullary nailing. In addition, six femora in three patients were subsequently lengthened by distraction osteogenesis. The mean follow-up was 60 months (18 to 120). The frontal alignment parameters (the mechanical axis deviation, the lateral distal femoral angle and the medial proximal tibial angle) and the sagittal alignment parameters (the posterior distal femoral angle and the posterior proximal tibial angle) improved post-operatively. The external fixator was removed either at the end of surgery or at the end of the lengthening period, allowing for early mobilisation and weight-bearing. We encountered five problems and four obstacles in the programme of treatment. The use of intramedullary nails prevented recurrence of deformity and refracture


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects. A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed. The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result. With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects. Cite this article: Bone Joint J 2013;95-B:1667–72


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 830 - 836
1 Aug 2004
Jones S Al Hussainy HA Ali F Betts RP Flowers MJ

We prospectively reviewed 24 patients (35 feet) who had been treated by a Scarf osteotomy and Akin closing-wedge osteotomy for hallux valgus between June 2000 and June 2002. There were three men and 21 women with a mean age of 46 years at the time of surgery. The mean follow-up time was 20 months. Our results showed that 50% of the patients were very satisfied, 42% were satisfied, and 8% were not satisfied. The mean American Orthopaedic Foot and Ankle Society score improved significantly from 52 points pre-operatively to 89 at follow-up (p < 0.001). The intermetatarsal and hallux valgus angles improved from the mean pre-operative values of 15° and 33° to 9° and 14°, respectively. These improvements were significant (p < 0.0001). The change in the distal metatarsal articular angle was not significant (p = 0.18). There was no significant change in the mean pedobarographic measurements of the first and second metatarsals after surgery (p = 0.2). The mean pedobarographic measurements of the first and second metatarsals at more than one year after surgery were within the normal range. Two patients had wound infections which settled after the administration of antibiotics. One patient had an intra-operative fracture of the first metatarsal and one required further surgery to remove a long distal screw which was irritating the medial sesamoids. We conclude that the Scarf osteotomy combined with the Akin closing-wedge osteotomy is safe and effective for the treatment of hallux valgus


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 250 - 252
1 Mar 2001
Solan MC Lemon M Bendall SP

Most techniques described for the correction of hallux valgus require exposure of the distal aspect of the first metatarsal. A dorsomedial incision is often recommended. Texts counsel against damaging the dorsal digital nerve, as a painful neuroma is an unwelcome surgical complication. Our study on cadavers aimed to investigate the anatomy of the dorsomedial cutaneous nerve in the metatarsophalangeal region, with special reference to surgical incisions. A constant, previously unrecognised branch of the nerve was identified. This branch is likely to be damaged if a dorsomedial approach is used. It is recommended that a mid-medial incision be used instead, i.e. at the junction of the plantar and dorsal skin


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1016 - 1020
1 Sep 2004
Schneider W Aigner N Pinggera O Knahr K

The Chevron osteotomy was described in 1976. There have, however, been only short- to mid-term follow-up reviews, often with small numbers of patients. We looked at 112 feet (73 patients) with a minimum follow-up of ten years following Chevron osteotomy with a distal soft-tissue procedure. Clinical evaluation was calculated using the hallux score of the American Orthopedic Foot and Ankle Society (AOFAS). For 47 feet (30 patients), the results were compared with those from an interim follow-up of 5.6 years. The AOFAS-score improved from a pre-operative mean of 46.5 points to a mean of 88.8 points after a mean of 12.7 years. The first metatarsophalangeal (MTP) angle showed a mean pre-operative value of 27.6° and was improved to 14.0°. The first intermetatarsal (IM) angle improved from a pre-operative mean value of 13.8° to 8.7°. The mean pre-operative grade of sesamoid subluxation was 1.7 on a scale from 0 to 3 and improved to 1.2. Measured on a scale from 0 to 3, arthritis of the first MTP joint progressed from a mean of 0.8 to 1.7. Comparing the results in patients younger and older than 50 years, the Chevron osteotomy performed equally in both age groups. Analysing the subgroup of 47 feet with a post-operative follow-up of both 5.6 and 12.7 years, the AOFAS pain and the overall score showed a further improvement between both follow-up evaluations. The MTP angle, first IM angle and sesamoid position remained unchanged. The progression of arthritis of the first MTP joint between 5.6 and 12.7 years post-operatively was statistically significant. Only one patient required a revision procedure due to painful recurrence of the deformity. Excellent clinical results following Chevron osteotomy not only proved to be consistent, but showed further improvement over a longer follow-up period. The mean radiographic angles were constant without recurrence of the deformity. So far, the statistically significant progression of first MTP joint arthritis has not affected the clinical result, but this needs further observation


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims

Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages.

Patients and Methods

We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 952 - 960
1 Jul 2016
Muderis MA Tetsworth K Khemka A Wilmot S Bosley B Lord SJ Glatt V

Aims

This study describes the Osseointegration Group of Australia’s Accelerated Protocol two-stage strategy (OGAAP-1) for the osseointegrated reconstruction of amputated limbs.

Patients and Methods

We report clinical outcomes in 50 unilateral trans-femoral amputees with a mean age of 49.4 years (24 to 73), with a minimum one-year follow-up. Outcome measures included the Questionnaire for persons with a Trans-Femoral Amputation, the health assessment questionnaire Short-Form-36 Health Survey, the Amputation Mobility Predictor scores presented as K-levels, 6 Minute Walk Test and timed up and go tests. Adverse events included soft-tissue problems, infection, fractures and failure of the implant.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 675 - 680
1 May 2015
Domeij-Arverud E Labruto F Latifi A Nilsson G Edman G Ackermann PW

Deep vein thrombosis is a common complication of immobilising the lower limb after surgery. We hypothesised that intermittent pneumatic compression (IPC) therapy in outpatients who had undergone surgical repair of acute ruptures of the Achilles tendon could reduce the incidence of this problem.

A total of 150 patients who had undergone surgical repair of the Achilles tendon were randomised to either treatment with IPC for six hours per day (n = 74) under an orthosis or treatment as usual (n = 74) in a plaster cast without IPC. At two weeks post-operatively, the incidence of deep vein thrombosis was assessed using blinded, double-reported compression duplex ultrasound. At this point, IPC was discontinued and all patients were immobilised in an orthosis for a further four weeks. At six weeks post-operatively, a second compression duplex ultrasound scan was performed.

At two weeks, the incidence of deep vein thrombosis was 21% in the treated group and 37% in the control group (p = 0.042). Age over 39 years was found to be a strong risk factor for deep vein thrombosis (odds ratio (OR) = 4.84, 95% confidence interval (CI) 2.14 to 10.96). Treatment with IPC, corrected for age differences between groups, reduced the risk of deep vein thrombosis at the two-week point (OR = 2.60; 95% CI 1.15 to 5.91; p =0.022). At six weeks, the incidence of deep vein thrombosis was 52% in the treated group and 48% in the control group (OR 0.94, 95% CI 0.49 to 1.83). IPC appears to be an effective method of reducing the risk of deep vein thrombosis in the early stages of post-operative immobilisation of outpatients. Further research is necessary to elucidate whether it can confer similar benefits over longer periods of immobilisation and in a more heterogeneous group of patients.

Cite this article: Bone Joint J 2015;97-B:675–80.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1349 - 1354
1 Oct 2014
Conway J Mansour J Kotze K Specht S Shabtai L

The treatment of infected nonunions is difficult. Antibiotic cement-coated (ACC) rods provide stability as well as delivering antibiotics. We conducted a review of 110 infected nonunions treated with ACC rods. Patients were divided into two groups: group A (67 patients) with an infected arthrodesis, and group B (43 patients) with an infected nonunion in a long bone. In group A, infected arthrodesis, the success rate after the first procedure was 38/67 (57%), 29/67 (43%) required further surgery for either control of infection or non-union. At last follow-up, five patients required amputation, representing a limb salvage rate of 62/67 (93%) overall. In all, 29/67 (43%) presented with a bone defect with a mean size of 6.78 cm (2 to 25). Of those with a bone defect, 13/29 (45%) required further surgery and had a mean size of defect of 7.2 cm (3.5 to 25). The cultures were negative in 17/67 (26%) and the most common organism cultured was methicillin-resistant staphylococcus aureus (MRSA) (23/67, (35%)). In group B, long bones nonunion, the success rate after the first procedure was 26/43 (60%), 17/43 (40%) required further surgery for either control of infection or nonunion. The limb salvage rate at last follow-up was 43/43 (100%). A total of 22/43 (51%) had bone defect with a mean size of 4.7 cm (1.5 to 11.5). Of those patients with a bone defect, 93% required further surgery with a mean size of defect of 5.4 cm (3 to 8.5). The cultures were negative in 10/43 (24%) and the most common organism cultured was MRSA, 15/43 (35%). ACC rods are an effective form of treatment for an infected nonunion, with an acceptable rate of complications.

Cite this article: Bone Joint J 2014; 96-B:1349–54


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 783 - 788
1 Jun 2014
Kanakaris N Gudipati S Tosounidis T Harwood P Britten S Giannoudis PV

Intramedullary infection in long bones represents a complex clinical challenge, with an increasing incidence due to the increasing use of intramedullary fixation. We report a prospective case series using an intramedullary reaming device, the Reamer–Irrigator–Aspirator (RIA) system, in association with antibiotic cement rods for the treatment of lower limb long bone infections. A total of 24 such patients, 16 men and eight women, with a mean age of 44.5 years (17 to 75), 14 with femoral and 10 with tibial infection, were treated in a staged manner over a period of 2.5 years in a single referral centre. Of these, 21 patients had had previous surgery, usually for fixation of a fracture (seven had sustained an open fracture originally and one had undergone fasciotomies). According to the Cierny–Mader classification system, 18 patients were classified as type 1A, four as 3A (discharging sinus tract), one as type 4A and one as type 1B. Staphylococcus species were isolated in 20 patients (83.3%). Local antibiotic delivery was used in the form of impregnated cement rods in 23 patients. These were removed at a mean of 2.6 months (1 to 5). Pathogen-specific antibiotics were administered systemically for a mean of six weeks (3 to 18). At a mean follow-up of 21 months (8 to 36), 23 patients (96%) had no evidence of recurrent infection. One underwent a planned trans-tibial amputation two weeks post-operatively due to peripheral vascular disease and chronic recalcitrant osteomyelitis of the tibia and foot. The combination of RIA reaming, the administration of systemic pathogen-specific antibiotics and local delivery using impregnated cement rods proved to be a safe and efficient form of treatment in these patients.

Cite this article: Bone Joint J 2014; 96-B:783–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1241 - 1245
1 Sep 2012
Burghardt RD Paley D Specht SC Herzenberg JE

Internal lengthening devices in the femur lengthen along the anatomical axis, potentially creating lateral shift of the mechanical axis. We aimed to determine whether femoral lengthening along the anatomical axis has an inadvertent effect on lower limb alignment. Isolated femoral lengthening using the Intramedullary Skeletal Kinetic Distractor was performed in 27 femora in 24 patients (mean age 32 years (16 to 57)). Patients who underwent simultaneous realignment procedures or concurrent tibial lengthening, or who developed mal- or nonunion, were excluded. Pre-operative and six-month post-operative radiographs were used to measure lower limb alignment. The mean lengthening achieved was 4.4 cm (1.5 to 8.0). In 26 of 27 limbs, the mechanical axis shifted laterally by a mean of 1.0 mm/cm of lengthening (0 to 3.5). In one femur that was initially in varus, a 3 mm medial shift occurred during a lengthening of 2.2 cm.

In a normally aligned limb, intramedullary lengthening along the anatomical axis of the femur results in a lateral shift of the mechanical axis by approximately 1 mm for each 1 cm of lengthening.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 663 - 667
1 May 2012
Ortiz C Wagner E Mocoçain P Labarca G Keller A Del Buono A Maffulli N

We tested four types of surgical repair for load to failure and distraction in a bovine model of Achilles tendon repair. A total of 20 fresh bovine Achilles tendons were divided transversely 4 cm proximal to the calcaneal insertion and randomly repaired using the Dresden technique, a Krackow suture, a triple-strand Dresden technique or a modified oblique Dresden technique, all using a Fiberwire suture. Each tendon was loaded to failure. The force applied when a 5 mm gap was formed, peak load to failure, and mechanism of failure were recorded. The resistance to distraction was significantly greater for the triple technique (mean 246.1 N (205 to 309) to initial gapping) than for the Dresden (mean 180 N (152 to 208); p = 0.012) and the Krackow repairs (mean 101 N (78 to 112; p < 0.001). Peak load to failure was significantly greater for the triple-strand repair (mean 675 N (453 to 749)) than for the Dresden (mean 327.8 N (238 to 406); p < 0.001), Krackow (mean 223.6 N (210 to 252); p <  0.001) and oblique repairs (mean 437.2 N (372 to 526); p < 0.001). Failure of the tendon was the mechanism of failure for all specimens except for the tendons sutured using the Krackow technique, where the failure occurred at the knot.

The triple-strand technique significantly increased the tensile strength (p = 0.0001) and gap resistance (p = 0.01) of bovine tendon repairs, and might have advantages in human application for accelerated post-operative rehabilitation.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1227 - 1231
1 Sep 2013
Domeij-Arverud E Latifi A Labruto F Nilsson G Ackermann PW

We hypothesised that adjuvant intermittent pneumatic compression (IPC) beneath a plaster cast would reduce the risk of deep-vein thrombosis (DVT) during post-operative immobilisation of the lower limb. Of 87 patients with acute tendo Achillis (TA) rupture, 26 were prospectively randomised post-operatively after open TA repair. The treatment group (n = 14) received two weeks of IPC of the foot for at least six hours daily under a plaster cast. The control group (n = 12) had no additional treatment. At two weeks post-operatively all patients received an orthosis until follow-up at six weeks. At two and six weeks the incidence of DVT was assessed using colour duplex sonography by two ultrasonographers blinded to the treatment. Two patients withdrew from the study due to inability to tolerate IPC treatment.

An interim analysis demonstrated a high incidence of DVT in both the IPC group (9 of 12, 75%) and the controls (6 of 12, 50%) (p = 0.18). No significant differences in incidence were detected at two (p = 0.33) or six weeks (p = 0.08) post-operatively. Malfunction of the IPC leading to a second plaster cast was found to correlate with an increased DVT risk at two weeks (φ = 0.71; p = 0.019), leading to a premature abandonment of the study.

We cannot recommend adjuvant treatment with foot IPC under a plaster cast for outpatient DVT prevention during post-operative immobilisation, owing to a high incidence of DVT related to malfunctioning of this type of IPC application.

Cite this article: Bone Joint J 2013;95-B:1227–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 782 - 787
1 Jun 2011
Sun X Easwar TR Manesh S Ryu J Song S Kim S Song H

We compared the complications and outcome of tibial lengthening using the Ilizarov method with and without the use of a supplementary intramedullary nail. In a retrospective case-matched series assembled from 176 patients with tibial lengthening, we matched 52 patients (26 pairs, group A with nail and group B without) according to the following criteria in order of importance: 1) difference in amount of lengthening (± 2 cm); 2) percentage difference in lengthening (± 5%); 3) difference in patient’s age (± seven years); 4) aetiology of the shortening, and 5) level of difficulty in obtaining the correction. The outcome was evaluated using the external fixator index, the healing index and an outcome score according to the criteria of Paley. It was found that some complications were specific to group A or B respectively, but others were common to both groups.

The outcome was generally better in lengthenings with a nail, although there was a higher incidence of rectifiable equinus deformity in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 660 - 662
1 May 2012
Aldridge SE Heilpern GNA Carmichael JR Sprowson AP Wood DG

Incomplete avulsion of the proximal hamstrings can be a severely debilitating injury that causes weakness, pain while sitting and inability to run. The results of the surgical treatment of 23 consecutive patients with such injuries at least two years after surgery are described. The surgery consisted of the repair of the hamstrings directly onto the ischial tuberosity. At review, using a visual analogue scale (VAS, 0 to 100), pain while sitting improved from a mean of 40 (0 to 100) to 64 (0 to 100) (p = 0.024), weakness from a mean of 39 (0 to 90) to 76 (7 to 100) (p = 0.0001) and the ability to run from a mean of 24 (0 to 88) to 64 (0 to 95) (p = 0.0001). According to a VAS, satisfaction was rated at a mean of 81 (0 to 100) and 20 patients (87%) would have the same procedure again. Hamstring strength measured pre- and post-operatively had improved significantly from a mean of 64% (0% to 95%) to 88% (50% to 114%) compared with the normal side.

Most of these patients with symptomatic incomplete hamstring avulsions unresponsive to conservative treatment had an improved outcome after surgical repair.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 639 - 643
1 May 2011
Burghardt RD Herzenberg JE Specht SC Paley D

Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device.

The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 75 - 79
1 Jan 2012
Herscovici, Jr D Scaduto JM

The use of autograft bone is the best option when undertaking a procedure that requires bone graft because it is osteogenic, osteoconductive and osseo-inductive. Pain, morbidity and complications associated with harvesting iliac or non-iliac sites occur in between 6% and 30% of cases. An alternative source of graft with possibly a lower morbidity is the intramedullary canal. In this study, 28 patients undergoing 30 arthrodesis procedures on the hindfoot had a mean of 48 cm3 (43 to 50) of bone harvested locally from the hindfoot or the tibial shaft by antegrade or retrograde reaming. No patient sustained a fracture of the calcaneum, talus or tibia. There was no morbidity except for one complication when the reamer breached the medial tibial cortex. This healed uneventfully.

This method of using the reamer–irrigator–aspirator system is an extension of the standard technique of intramedullary reaming of the lower limb: it produces good-quality bone graft with viable growth factors consistent with that of the iliac crest, and donor site morbidity is low. This is an efficient method of obtaining autologous bone for use in arthrodesis of the ankle or hindfoot.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 788 - 792
1 Jun 2011
Schiedel FM Pip S Wacker S Pöpping J Tretow H Leidinger B Rödl R

We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties.

Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 634 - 638
1 May 2011
Cho T Kim J Lee JW Lee K Park MS Yoo WJ Chung CY Choi IH

We investigated the fracture-free survival of long bones stabilised by a telescopic intramedullary rod (TIMR) in patients with osteogenesis imperfecta with respect to the remodelling status of fracture or osteotomy sites and TIMR regions, in order to identify risk factors for fracture. A total of 44 femora and 28 tibiae in 25 patients with a mean age of 5.0 years (1.9 to 10.5) at presentation were studied. There were six patients with Sillence type I, five with type III, 13 with type IV and one with type V osteogenesis imperfecta. All received bisphosphonate treatment at the same stage during the mean follow-up of 7.3 years (0.5 to 18.1). The fracture-free survival was estimated at 6.2 years (95% confidence interval 5.1 to 7.3) by Kaplan-Meier analysis. More than half the fracture or osteotomy sites remained in a less-remodelled state at the latest follow-up or time of fracture. Of the 33 fractures, 29 (87.9%) occurred in long bones containing a less-remodelled site, and these fractures were located at this site. The relative fracture risk at the rod tip was significantly greater than in any other TIMR region (p < 0.001), and this was higher in bone segments having a less-remodelled site.

This study shows a persistent fracture risk in TIMR-stabilised long bones, especially at less-remodelled fracture or osteotomy sites and at the rod tip.