We have reviewed 402 traumatic fractures of the femoral shaft, 320 of which had been treated by operation and had a long follow-up. Of these, 228 closed fractures and 37 open fractures had been stabilised by plating. There was no significant difference in healing between those stabilised early and those having delayed internal fixation. Re-fracture after removal of the implant occurred more often after early operation. All 55 fractures treated by intramedullary nailing healed and there were no re-fractures after nail removal. We found no correlation between delay before operation and the incidence of postoperative infection.