We reviewed 120 consecutive primary total hip replacements in 109 patients in whom a Freeman uncemented metal-backed component had been used. Acetabular components were used with a Freeman neck-retaining stem in one of three configurations: cemented smooth stem, uncemented smooth stem or uncemented ridged stem. After a mean follow up of 72 months (62 to 113) there were nine cases of aseptic loosening; a survivorship at eight years of 83%. In addition, more than one-third of the remaining surviving cups showed loosening radiologically. The Freeman acetabular component demonstrated a characteristic pattern of loosening on radiographs. The high incidence of aseptic loosening can be explained by poor design and material failure.
We have reviewed 202 consecutive primary hip replacements using a Freeman cemented femoral component after a mean period of follow-up of 64 months (23 to 113). There was only one revision for aseptic loosening. Retention of the femoral neck may act to reduce the torsional and shear forces at the implant-cement interface and may provide a seal against the migration of polyethylene-laden joint fluid in the potential joint space. The cemented Freeman femoral component with retention of the femoral neck was successful for up to nine years.