We aimed to determine hip-related quality of life and clinical findings following treatment for neonatal hip instability (NHI) compared with age- and sex-matched controls. We hypothesized that NHI would predispose to hip discomfort in long-term follow-up. We invited those born between 1995 and 2001 who were treated for NHI at our hospital to participate in this population-based study. We included those that had Von Rosen-like splinting treatment started before one month of age. A total of 96 patients treated for NHI (75.6 %) were enrolled. A further 94 age- and sex-matched controls were also recruited. The Copenhagen Hip and Groin Outcome Score (HAGOS) questionnaire was completed separately for both hips, and a physical examination was performed.Aims
Methods
Previous studies from single centres or single-surgeon
series report good early and mid-term results for high tibial osteotomy
(HTO) in the treatment of osteoarthritis of the knee. However, the
survivorship of HTO at a national level is unknown. This registry-based
study included 3195 high HTOs performed between 1987 and 2008. Kaplan-Meier analysis
revealed an overall survivorship of 89% (95% confidence interval
(CI) 88 to 90) at five years and 73% (95% CI 72 to 75) at ten years,
when conversion to total knee replacement was taken as the endpoint.
Females and patients aged >
50 years had worse survivorship than
males or patients aged ≤ 50 years (hazard ratio (HR) 1.26 (95% CI
1.11 to 1.43) and HR 1.41 (95% CI 1.23 to 1.64), respectively).
The survivorship of HTOs performed between 1998 to 2008 was worse
than for those performed between 1987 and 1997.
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,