As part of the national initiative to reduce
waiting times for joint replacement surgery in Wales, the Cardiff
and Vale NHS Trust referred 224 patients to the NHS Treatment Centre
in Weston-Super-Mare for total knee replacement (TKR). A total of
258 Kinemax TKRs were performed between November 2004 and August
2006. Of these, a total of 199 patients (232 TKRs, 90%) have been
followed up for five years. This cohort was compared with 258 consecutive
TKRs in 250 patients, performed at Cardiff and Vale Orthopaedic
Centre (CAVOC) over a similar time period. The five year cumulative
survival rate was 80.6% (95% confidence interval (CI) 74.0 to 86.0)
in the Weston-Super-Mare cohort and 95.0% (95% CI 90.2 to 98.2)
in the CAVOC cohort with revision for any reason as the endpoint.
The relative risk for revision at Weston-Super-Mare compared with
CAVOC was 3.88 (p <
0.001). For implants surviving five years,
the mean Oxford knee scores (OKS) and mean EuroQol (EQ-5D) scores
were similar (OKS: Weston-Super-Mare 29 (2 to 47) The results show a higher revision rate for patients operated
at Weston-Super-Mare Treatment Centre, with a reduction in functional
outcome and quality of life after revision. This further confirms
that patients moved from one area to another for joint replacement
surgery fare poorly.
We aimed to determine the reliability, accuracy and the clinical role of digital templating in the pre-operative work-up for total knee replacement. Initially a sample of ten pre-operative digital radiographs were templated by four independent observers to determine the inter- and intra-observer reliability of the process. Digital templating was then performed on the radiographs of 40 consecutive patients undergoing total knee replacement by a consultant surgeon not involved with the operation, who was blinded to the size of the implant inserted. The Press Fit Condylar Sigma Knee system was used in all the patients. The size of the implant as judged by templating was then compared to that of the size used. Good inter- and intra-observer agreement was demonstrated for both femoral and tibial templating. However, the correct size of the implant was predicted in only 48% of the femoral and 55% of the tibial components. Albeit reproducible, digital templating does not currently predict the correct size of component often enough to be of clinical benefit.
The clinical results of bilateral total knee replacement staged at a one-week interval during a single hospital admission were compared with bilateral total knee replacements performed under the same anaesthetic and with bilateral total knee replacements performed during two separate admissions. The data were retrospectively reviewed. All operations had been performed by the same surgeon using the same design of prosthesis at a single institution. The operative time and length of stay for the one-week staged group were comparable with those of the separate admission group but longer than for the patients treated under one anaesthetic. There was a low rate of complications and good clinical outcome in all groups at a mean follow-up of four years (1 to 7.2). The group staged at a one-week interval had the least blood loss (p = 0.004). With appropriate patient selection, bilateral total knee replacement performed under a single anaesthetic, or staged at a one-week interval, is a safe and effective method to treat bilateral arthritis of the knee.