Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1241 - 1245
1 Sep 2012
Burghardt RD Paley D Specht SC Herzenberg JE

Internal lengthening devices in the femur lengthen along the anatomical axis, potentially creating lateral shift of the mechanical axis. We aimed to determine whether femoral lengthening along the anatomical axis has an inadvertent effect on lower limb alignment. Isolated femoral lengthening using the Intramedullary Skeletal Kinetic Distractor was performed in 27 femora in 24 patients (mean age 32 years (16 to 57)). Patients who underwent simultaneous realignment procedures or concurrent tibial lengthening, or who developed mal- or nonunion, were excluded. Pre-operative and six-month post-operative radiographs were used to measure lower limb alignment. The mean lengthening achieved was 4.4 cm (1.5 to 8.0). In 26 of 27 limbs, the mechanical axis shifted laterally by a mean of 1.0 mm/cm of lengthening (0 to 3.5). In one femur that was initially in varus, a 3 mm medial shift occurred during a lengthening of 2.2 cm.

In a normally aligned limb, intramedullary lengthening along the anatomical axis of the femur results in a lateral shift of the mechanical axis by approximately 1 mm for each 1 cm of lengthening.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 52 - 56
1 Jan 2011
Kocaoglu M Bilen FE Sen C Eralp L Balci HI

We present the results of the surgical correction of lower-limb deformities caused by metabolic bone disease. Our series consisted of 17 patients with a diagnosis of hypophosphataemic rickets and two with renal osteodystrophy; their mean age was 25.6 years (14 to 57). In all, 43 lower-limb segments (27 femora and 16 tibiae) were osteotomised and the deformity corrected using a monolateral external fixator. The segment was then stabilised with locked intramedullary nailing. In addition, six femora in three patients were subsequently lengthened by distraction osteogenesis. The mean follow-up was 60 months (18 to 120). The frontal alignment parameters (the mechanical axis deviation, the lateral distal femoral angle and the medial proximal tibial angle) and the sagittal alignment parameters (the posterior distal femoral angle and the posterior proximal tibial angle) improved post-operatively. The external fixator was removed either at the end of surgery or at the end of the lengthening period, allowing for early mobilisation and weight-bearing. We encountered five problems and four obstacles in the programme of treatment.

The use of intramedullary nails prevented recurrence of deformity and refracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 343 - 347
1 Mar 2005
Winson IG Robinson DE Allen PE

We reviewed 116 patients who underwent 118 arthroscopic ankle arthrodeses. The mean age at operation was 57 years, 2 months (20 to 86 years). The indication for operation was post-traumatic osteoarthritis in 67, primary osteoarthritis in 36, inflammatory arthropathy in 13 and avascular necrosis in two. The mean follow-up was 65 months (18 to 144). Nine patients (10 ankles) died before final review and three were lost to follow-up, leaving 104 patients (105 ankles) who were assessed by a standard telephone interview. The pre-operative talocrural deformity was between 22° valgus and 28° varus, 94 cases were within 10° varus/valgus. The mean time to union was 12 weeks (6 to 20). Nonunion occurred in nine cases (7.6%). Other complications included 22 cases requiring removal of a screw for prominence, three superficial infections, two deep vein thromboses/pulmonary emboli, one revision of fixation, one stress fracture and one deep infection. Six patients had a subtalar fusion at a mean of 48 months after ankle fusion. There were 48 patients with excellent, 35 with good, 10 with fair and 11 with poor clinical results.