Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 69 - 74
1 Jan 2001
Gagey OJ Gagey N

We studied 100 fresh human shoulders in cadavers (mean age 76 years), and the range of passive abduction (RPA) in 100 volunteers with normal shoulders and in 90 patients with instability of the joint, over a period of six years. The anatomical and clinical findings showed that passive abduction occurs within the glenohumeral joint only, is controlled by the inferior glenohumeral ligament and has a constant value in 95% of both shoulders in normal subjects. In patients with instability, 85% showed an RPA of over 105° with 90° in the contralateral shoulder. In the remaining patients a strongly positive apprehension test suggested a diagnosis of instability. An RPA of more than 105° is associated with lengthening and laxity of the inferior glenohumeral ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 868 - 872
1 Aug 2001
Smith SP Bunker TD

We reviewed 12 patients with primary glenoid dysplasia. Ten were assessed clinically and two from case notes and radiographs. We identified two groups according to the age at onset of symptoms. The first (seven patients) consisted of boys and younger men, all of whom developed symptoms before the age of 40 years. All four children were free from pain, whereas the three adults in this group had varying degrees of this. Four patients had symptoms of instability. The second group consisted of older men (five patients) all of whom had noted the onset of symptoms, in the form of pain and stiffness, after the age of 40 years. All five had radiological evidence of osteoarthritis. Although the four children in our study had minimal symptoms, all eight adults had ongoing shoulder pain and dysfunction, despite a specific rehabilitation programme. Four patients required surgery; one had posterior stabilisation for instability and three arthroplasties of the shoulder for osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 213 - 221
1 Mar 2001
Levy O Copeland SA

Cementless surface replacement arthroplasty of the shoulder is designed to replace the damaged joint surfaces and restore normal anatomy with minimal resection of bone. We have used the Copeland shoulder arthroplasty for 14 years. Between 1986 and 2000, 285 surface replacement arthroplasties were implanted in our unit. The prosthesis has evolved during this time, but the principle of minimal bone resection has remained the same. Between 1990 and 1994, 103 Mark-2 prostheses were inserted into 94 patients (9 bilateral). The operations were carried out for the treatment of osteoarthritis, rheumatoid arthritis, avascular necrosis, instability arthropathy, post-traumatic arthropathy and cuff arthropathy. The mean follow-up was for 6.8 years (5 to 10). The best results were achieved in primary osteoarthritis, with Constant scores of 93.7% for total shoulder replacement and 73.5% for hemiarthroplasty. The poorest results were seen in patients with cuff arthropathy and post-traumatic arthropathy with adjusted Constant scores of 61.3% and 62.7%, respectively. Most patients (93.9%) considered their shoulder to be much better or better than before the operation. Of the 88 humeral implants available for radiological review, 61 (69.3%) showed no evidence of radiolucency, nor did 21 (35.6%) of the 59 glenoid prostheses. Three were definitely loose, and eight shoulders required revision (7.7%), two (1.9%) for primary loosening. The results of this series are comparable with those for stemmed prostheses with a similar follow-up and case mix. The cementless surface replacement arthroplasty diminishes the risk of complications involving the humeral shaft and periprosthetic fractures. Revision or arthrodesis can be undertaken easily since the bone stock has been maintained with no loss of length