Ununited fractures of the scaphoid with extensive
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,
and commonly requires removal of the prosthesis.
This study was performed to determine whether
pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient
to achieve bony union and restore alignment in scaphoid nonunion.
A total of 65 patients who underwent cancellous bone graft and K-wire
fixation were included in this study. The series included 61 men
and four women with a mean age of 34 years (15 to 72) and mean delay
to surgery of 28.7 months (3 to 240). The patients were divided
into an unstable group (A) and stable group (B) depending on the
pre-operative radiographs. Unstable nonunion was defined as a lateral
intrascaphoid angle >
45°, or a radiolunate angle >
10°. There were
34 cases in group A and 31 cases in group B. Bony union was achieved
in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B
(p = 0.439). Comparison of the post-operative radiographs between
the two groups showed no significant differences in lateral intrascaphoid
angle (p = 0.657) and scaphoid length
(p = 0.670) and height (p = 0.193). The radiolunate angle was significantly
different
(p = 0.020) but the mean value in both groups was <
10°. Comparison
of the dorsiflexion and palmar flexion of movement of the wrist
and the mean Mayo wrist score at the final clinical visit in each
group showed no significant difference (p = 0.190, p = 0.587 and
p = 0.265, respectively). Cancellous bone graft and K-wire fixation
were effective in the treatment of stable and unstable scaphoid
nonunion. Cite this article:
Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were cuff tear arthropathy in 48 shoulders, revision of shoulder prostheses of various types in 11 and massive cuff tear in nine. The development of scapular notching, bony scapular spur formation, heterotopic ossification, glenoid and humeral radiolucencies, stem subsidence, radiological signs of stress shielding and resorption of the tuberosities were assessed on standardised true anteroposterior and axillary radiographs. A scapular notch was observed in 60 shoulders (88%) and was associated with the superolateral approach (p = 0.009). Glenoid radiolucency was present in 11 (16%), bony scapular spur and/or ossifications in 51 (75%), and subsidence of the stem and humeral radiolucency in more than three zones were present in three (8.8%) and in four (11.8%) of 34 cemented components, respectively, and in one (2.9%) and two (5.9%) of 34 uncemented components, respectively. Radiological signs of stress shielding were significantly more frequent with uncemented components (p <
0.001), as was resorption of the greater (p <
0.001) and lesser tuberosities (p = 0.009).
We have examined the relief from pain and the functional outcome in 18 patients who underwent resection arthroplasty of the shoulder as a salvage operation between 1988 and 2002. The indications included failed shoulder replacement in 17, with infection in 13, and chronic septic arthritis in one. The mean follow-up was 8.3 years (2.5 to 16.6). Two intra-operative fractures of the humerus occurred, both of which healed. The level of pain was significantly decreased ( Despite applying this procedure principally to failed shoulder replacements, the results were similar to those reported in the literature for patients after severe fracture-dislocation. Reduction of pain is possible in one half to two-thirds of patients. The outcome of this operation in providing relief from pain cannot be guaranteed, but the shoulder is usually comfortable at rest, albeit with profound functional limitations.
We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation. Massive bone defects were augmented by autogenous bone grafts. There were no major complications such as infection, subluxation or loosening. In most elbows relief from pain and stability were achieved. The results, according to the Mayo Elbow Performance Score, were excellent in eight, good in five and fair in one. In most elbows there was minimal or no resorption of the grafted bone. There were no radiolucent lines around the stems of the cementless components. This study shows that even highly unstable rheumatoid elbows can be replaced successfully using an unlinked prosthesis, with augmentation by grafting for major defects of bone.