Advertisement for orthosearch.org.uk
Results 1 - 51 of 51
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 224 - 229
1 Feb 2010
Arora R Lutz M Zimmermann R Krappinger D Niederwanger C Gabl M

We report the use of a free vascularised iliac bone graft in the treatment of 21 patients (19 men and 2 women) with an avascular nonunion of the scaphoid in which conventional bone grafting had previously failed. The mean age of the patients was 32 years (23 to 46) and the dominant wrist was affected in 14. The mean interval from fracture to the vascularised bone grafting was 39 months (9 to 62). Pre-operative MRI showed no contrast enhancement in the proximal fragment in any patient. Fracture union was assessed radiologically or with CT scans if the radiological appearances were inconclusive. At a mean follow-up of 5.6 years (2 to 11) union was obtained in 16 patients. The remaining five patients with a persistent nonunion continued to experience pain, reduced grip strength and limited range of wrist movement. In the successfully treated patients the grip strength and range of movement did not recover to match the uninjured side. Prevention of progressive carpal collapse, the absence of donor site morbidity, good subjective results and pain relief, justifies this procedure in the treatment of recalcitrant nonunion of the scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 932 - 936
1 Jul 2011
Mahmoud M Koptan W

Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved. We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1090 - 1096
1 Aug 2012
Mahmoud M El Shafie S Kamal M

Malunion is the most common complication of the distal radius with many modalities of treatment available for such a problem. The use of bone grafting after an osteotomy is still recommended by most authors. We hypothesised that bone grafting is not required; fixing the corrected construct with a volar locked plate helps maintain the alignment, while metaphyseal defect fills by itself. Prospectively, we performed the procedure on 30 malunited dorsally-angulated radii using fixed angle volar locked plates without bone grafting. At the final follow-up, 22 wrists were available. Radiological evidence of union, correction of the deformity, clinical and functional improvement was achieved in all cases. Without the use of bone grafting, corrective open wedge osteotomy fixed by a volar locked plate provides a high rate of union and satisfactory functional outcomes


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 409 - 412
1 Apr 2000
Kumta SM Leung PC Griffith JF Kew J Chow LTC

We describe our experience with vascularised bone grafting for the treatment of fibrous dysplasia of the upper limb in eight patients, five men and three women, aged between 17 and 36 years. The site was in the humerus in six and the radius in two. Persistent pain, progression of the lesion and pathological fracture with delayed union were the indications for surgical intervention. We used a vascularised fibular graft after curettage of the lesion. Function and radiological progress were serially monitored. Early radiological union of the graft occurred at periods ranging from 8 to 14 weeks. The mean period for reconstitution of the diameter of the bone was 14 months (12 to 18) predominantly through inductive formation of bone around the vascularised graft, which was a prominent feature in all patients. There were no recurrences and none of the grafts sustained a fracture or failed to unite. After operation function was excellent in three patients and good in five. Vascularised bone grafts provide a safe and reliable means of ensuring good continuity of bone with little risk of recurrence and failure


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 627 - 632
1 May 2007
Ramamurthy C Cutler L Nuttall D Simison AJM Trail IA Stanley JK

This study identified variables which influence the outcome of surgical management on 126 ununited scaphoid fractures managed by internal fixation and non-vascular bone grafting. The site of fracture was defined by a new method: the ratio of the length of the proximal fragment to the sum of the lengths of both fragments, calculated using specific views in the plain radiographs. Bone healing occurred in 71% (89) of cases. Only the site of nonunion (p = 1 × 10. −6. ) and the delay to surgery (p = 0.001) remained significant on multivariate analysis. The effect of surgical delay on the probability of union increased as the fracture site moved proximally. A prediction model was produced by stepwise logistic regression analysis, enabling the surgeon to predict the success of surgery where the site of the nonunion and delay to surgery is known


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 566 - 570
1 May 2000
Anderson GA Thomas BP

Between June 1991 and May 1996 we carried out arthrodesis on 15 patients with flail or partially flail wrists using an AO/ASIF dynamic compression plate (DCP) without a bone graft. The wrist was approached through the second extensor compartment. The minimum follow-up was for 24 months with a mean of 34.2 months. All 15 wrists fused without major complications at a mean of 11.9 weeks. Stabilisation improved the function of the hand affected with paralysis and the appearance of the extensively paralysed upper limb with a flail hand. In the absence of bony abnormality fusion can be obtained with a DCP alone without the need for bone grafting


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1007 - 1012
1 Sep 2004
Sawaizumi T Nanno M Nanbu A Ito H

A vascularised bone-graft procedure from the base of the second metacarpal was performed in 14 patients with nonunion of the scaphoid. There were 11 men and three women with a mean age of 22 years. In eight patients, who had dorsiflexed intercalated segment instability (DISI), an open wedge was formed at the site of nonunion, and the vascular pedicle was grafted from the volar side. In the six patients without DISI, transplantation was carried out through the same dorsal skin incision.

Complete bony union was obtained in all patients after a mean post-operative period of 10.2 weeks, and DISI was corrected in all affected patients. According to Cooney’s clinical scoring system, the results were excellent in five, good in six, and fair in three patients. Because of its technical simplicity and the limited dissection needed, the procedure should be considered for the primary surgical treatment of patients with nonunion of the scaphoid.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 809 - 814
1 Jun 2013
Park HY Yoon JO Jeon IH Chung HW Kim JS

This study was performed to determine whether pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient to achieve bony union and restore alignment in scaphoid nonunion. A total of 65 patients who underwent cancellous bone graft and K-wire fixation were included in this study. The series included 61 men and four women with a mean age of 34 years (15 to 72) and mean delay to surgery of 28.7 months (3 to 240). The patients were divided into an unstable group (A) and stable group (B) depending on the pre-operative radiographs. Unstable nonunion was defined as a lateral intrascaphoid angle > 45°, or a radiolunate angle > 10°. There were 34 cases in group A and 31 cases in group B. Bony union was achieved in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B (p = 0.439). Comparison of the post-operative radiographs between the two groups showed no significant differences in lateral intrascaphoid angle (p = 0.657) and scaphoid length (p = 0.670) and height (p = 0.193). The radiolunate angle was significantly different (p = 0.020) but the mean value in both groups was < 10°. Comparison of the dorsiflexion and palmar flexion of movement of the wrist and the mean Mayo wrist score at the final clinical visit in each group showed no significant difference (p = 0.190, p = 0.587 and p = 0.265, respectively). Cancellous bone graft and K-wire fixation were effective in the treatment of stable and unstable scaphoid nonunion. Cite this article: Bone Joint J 2013;95-B:809–14


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 81 - 87
1 Jan 2016
Miska M Findeisen S Tanner M Biglari B Studier-Fischer S Grützner PA Schmidmaier G Moghaddam A

Methods. Between 2005 and 2012, 50 patients (23 female, 27 male) with nonunion of the humeral shaft were included in this retrospective study. The mean age was 51.3 years (14 to 88). The patients had a mean of 1.5 prior operations (. sd. 1.2;1 to 8). All patients were assessed according to a specific risk score in order to devise an optimal and individual therapy plan consistent with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis to an angular stable locking compression plate was performed. According to the individual risk an additional bone graft and/or bone morphogenetic protein-7 (BMP-7) were applied. Results. A successful consolidation of the nonunion was observed in 37 cases (80.4%) with a median healing time of six months (IQR 6). Younger patients showed significantly better consolidation. Four patients were lost to follow-up. Revision was necessary in a total of eight (16%) cases. In the initial treatment, intramedullary nailing was most common. . Discussion. The use of locking compression plates in combination with autologous cancellous bone graft has been shown to be a safe and effective treatment. In more complex cases, the use of the Masquelet technique and BMP-7 may be indicated at the first revision operation. Take home message: Our results suggest the Diamond Concept is a successful treatment strategy for nonunions of the humeral shaft. Cite this article: Bone Joint J 2016;98-B:81–7


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1597 - 1601
1 Dec 2008
Thompson NW Kapoor A Thomas J Hayton MJ

We describe the use of a vascularised periosteal patch onlay graft based on the 1,2 intercompartmental supraretinacular artery in the management of 11 patients (ten men, one woman) with chronic nonunion involving the proximal third of the scaphoid. The mean age of the patients was 31 years (21 to 45) with the dominant hand affected in eight. Six of the patients were smokers and three had undergone previous surgery to the scaphoid. All of the proximal fragments were avascular. The presence of union was assessed using longitudinal axis CT. Only three patients progressed to union of the scaphoid and four required a salvage operation for a symptomatic nonunion. The remaining four patients with a persistent nonunion are asymptomatic with low pain scores, good grip strength and a functional range of wrist movement. Although this technique has potential technical advantages over vascularised pedicled bone grafting, the rate of union has been disappointing and we do not recommend it as a method of treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 920 - 924
1 Jul 2006
Mori T Kudo H Iwano K Juji T

We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation. Massive bone defects were augmented by autogenous bone grafts. There were no major complications such as infection, subluxation or loosening. In most elbows relief from pain and stability were achieved. The results, according to the Mayo Elbow Performance Score, were excellent in eight, good in five and fair in one. In most elbows there was minimal or no resorption of the grafted bone. There were no radiolucent lines around the stems of the cementless components. This study shows that even highly unstable rheumatoid elbows can be replaced successfully using an unlinked prosthesis, with augmentation by grafting for major defects of bone


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1107 - 1110
1 Aug 2005
Ali A Douglas H Stanley D

Sixteen patients who underwent a revision operation for nonunion of fractures of the distal humerus following previous internal fixation were reviewed at a mean follow-up of 39 months (8 to 69). The Mayo elbow performance score was excellent in 11, good in two, fair in two and poor in one. In 15 patients union was achieved and in one with an infected nonunion a subsequent bone graft was necessary in order to obtain union. Age, gender, a history of smoking, mechanism of the injury and the AO classification of the initial fracture did not correlate with the development of nonunion. In 12 patients (75%), the initial fixation was assessed as being suboptimal. The primary surgery was regarded as adequate in only three patients. Our findings suggest that the most important determinant of nonunion of a distal humeral fracture after surgery is the adequacy of fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 75 - 81
1 Jan 2009
Cil A Veillette CJH Sanchez-Sotelo J Sperling JW Schleck C Cofield RH

Between 1976 and 2004, 38 revision arthroplasties (35 patients) were performed for aseptic loosening of the humeral component. The mean interval from primary arthroplasty to revision was 7.1 years (0.4 to 16.6). A total of 35 shoulders (32 patients) were available for review at a mean follow-up of seven years (2 to 19.3). Pre-operatively, 34 patients (97%) had moderate or severe pain; at final follow-up, 29 (83%) had no or only mild pain (p < 0.0001). The mean active abduction improved from 88° to 107° (p < 0.01); and the mean external rotation from 37° to 46° (p = 0.27). Excellent or satisfactory results were achieved in 25 patients (71%) according to the modified Neer rating system. Humeral components were cemented in 29, with ingrowth implants used in nine cases. There were 19 of standard length and 17 were longer (two were custom replacements and are not included). Bone grafting was required for defects in 11 humeri. Only two glenoid components were left unrevised. Intra-operative complications included cement extrusion in eight cases, fracture of the shaft of the humerus is two and of the tuberosity in four. There were four re-operations, one for recurrent humeral loosening, with 89% survival free of re-operations at ten years. Revision surgery for aseptic loosening of the humeral component provides reliable pain relief and modest improvement of movement, although there is a substantial risk of intra-operative complications. Revision to a total shoulder replacement gives better results than to a hemiarthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 702 - 704
1 Jul 2000
Cole AS Hill GA Abela M Carr AJ

We present three cases of recurrent instability of the elbow in association with the Ehlers-Danlos syndrome. The pattern of instability has not previously been reported. We describe our procedure for achieving stability using a bone graft to the olecranon fossa which gave a functional range of movement


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 217 - 219
1 Mar 2004
Kralinger F Schwaiger R Wambacher M Farrell E Menth-Chiari W Lajtai G Hübner C Resch H

We have examined 167 patients who had a hemiarthroplasty for three- and four-part fractures and fracture-dislocations of the head of the humerus in a multicentre study involving 12 Austrian hospitals. All patients were followed for more than a year. Anatomical healing of the tuberosity significantly influenced the outcome as measured by the Constant score and subjective patient satisfaction. With regard to pain, the outcome was generally satisfactory but only 41.9% of patients were able to flex the shoulder above 90°. The age of the patient and the type of prosthesis significantly influenced the healing of the tuberosity, but bone grafting did not. Achievement of healing of the tuberosity was inferior in institutions at which less than 15 hemiarthroplasties had been performed (Mann-Witney U test, p = 0.0001)


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 783 - 786
1 Sep 1996
Pech J Sosna A Rybka V Pokorný D

Arthrodesis of the wrist is a standard operation which is indicated for severe rheumatoid arthritis in which destruction is too advanced for more conservative procedures, or after failure of previous surgery. We have developed an L-shaped plate designed for this purpose. It provides rigid internal fixation with the wrist in the neutral position and utilises bone grafts obtained from the distal ulna and the carpal bones. We have carried out 29 successful fusions between 1992 and 1995. In all 29 patients synovectomy and resection of the head of the ulna were performed; 11 also had reconstruction of ruptured extensor tendons. All the patients obtained bony union, pain relief and improved function


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 666 - 670
1 Jul 2003
Wick M Müller EJ Ambacher T Hebler U Muhr G Kutscha-Lissberg F

We analysed the long-term results of arthrodesis of the shoulder after infection in 15 patients. At the time of operation, 14 cultures were positive for Staphylococcus aureus. The mean follow-up was 8.3 years (3 to 14) and 90% of the patients were satisfied with the outcome. There were complications in five patients (33%); in three there was nonunion with loosening of the implant. One patient had a sound bony union but with a persistent sinus six years after arthrodesis and another had a sinus which healed after the metal was removed. Four of these five patients (80%) were heavy smokers (> 20 cigarettes/day). Cancellous bone grafting did not affect the incidence of complications. The mean age of the patients with complications was 58.6 v 48.6 years for those without (p = 0.2808 ; not significant). Those with complications had had more previous operations (6.4 v 2.5, p < 0.05). Antibiotics, as determined by the bacteriological cultures, were administered for six weeks. The complication rate was higher in patients with active sepsis but the younger the patient and the fewer number of previous operations (< 50 years, < four previous operations), the better was the outcome. Considering the rate of complications, we recommend early surgery in these patients


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1448 - 1454
1 Nov 2012
Ng CY Watts AC

Bone loss involving articular surface is a challenging problem faced by the orthopaedic surgeon. In the hand and wrist, there are articular defects that are amenable to autograft reconstruction when primary fixation is not possible. In this article, the surgical techniques and clinical outcomes of articular reconstructions in the hand and wrist using non-vascularised osteochondral autografts are reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1382 - 1389
1 Oct 2012
Sewell MD Kang SN Al-Hadithy N Higgs DS Bayley I Falworth M Lambert SM

There is little information about the management of peri-prosthetic fracture of the humerus after total shoulder replacement (TSR). This is a retrospective review of 22 patients who underwent a revision of their original shoulder replacement for peri-prosthetic fracture of the humerus with bone loss and/or loose components. There were 20 women and two men with a mean age of 75 years (61 to 90) and a mean follow-up 42 months (12 to 91): 16 of these had undergone a previous revision TSR. Of the 22 patients, 12 were treated with a long-stemmed humeral component that bypassed the fracture. All their fractures united after a mean of 27 weeks (13 to 94). Eight patients underwent resection of the proximal humerus with endoprosthetic replacement to the level of the fracture. Two patients were managed with a clam-shell prosthesis that retained the original components. The mean Oxford shoulder score (OSS) of the original TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival using re-intervention for any reason as the endpoint was 91% (95% confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at one and five years, respectively.

There were two revisions for dislocation of the humeral head, one open reduction for modular humeral component dissociation, one internal fixation for nonunion, one trimming of a prominent screw and one re-cementation for aseptic loosening complicated by infection, ultimately requiring excision arthroplasty. Two patients sustained nerve palsies.

Revision TSR after a peri-prosthetic humeral fracture associated with bone loss and/or loose components is a salvage procedure that can provide a stable platform for elbow and hand function. Good rates of union can be achieved using a stem that bypasses the fracture. There is a high rate of complications and function is not as good as with the original replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1253 - 1259
1 Sep 2012
Sewell MD Higgs DS Al-Hadithy N Falworth M Bayley I Lambert SM

Scapulothoracic fusion (STF) for painful winging of the scapula in neuromuscular disorders can provide effective pain relief and functional improvement, but there is little information comparing outcomes between patients with dystrophic and non-dystrophic conditions. We performed a retrospective review of 42 STFs in 34 patients with dystrophic and non-dystrophic conditions using a multifilament trans-scapular, subcostal cable technique supported by a dorsal one-third semi-tubular plate. There were 16 males and 18 females with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0 years (2.0 to 10.6). The mean Oxford shoulder score improved from 20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions had lower overall functional scores but achieved greater improvements following STF. The mean active forward elevation increased from 59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10° to 90°) to 83° (30° to 130°) with a greater range of movement achieved in the dystrophic group. Revision fusion for nonunion was undertaken in five patients at a mean time of 17 months (7 to 31) and two required revision for fracture. There were three pneumothoraces, two rib fractures, three pleural effusions and six nonunions. The main risk factors for nonunion were smoking, age and previous shoulder girdle surgery.

STF is a salvage procedure that can provide good patient satisfaction in 82% of patients with both dystrophic and non-dystrophic pathologies, but there was a relatively high failure rate (26%) when poor outcomes were analysed. Overall function was better in patients with dystrophic conditions which correlated with better range of movement; however, patients with non-dystrophic conditions achieved greater functional improvement.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 47 - 53
1 Jan 2005
Whaley A Morrey BF Adams R

We examined the effects of previous resection of the radial head and synovectomy on the outcome of subsequent total elbow arthroplasty in patients with rheumatoid arthritis.

Fifteen elbows with a history of resection and synovectomy were compared with a control group of patients who had elbow arthroplasty with an implant of the same design. The mean age in both groups was 63 years. In the study group, resection of the radial head and synovectomy had been undertaken at a mean of 8.9 years before arthroplasty. The mean radiological follow-up for the 13 available patients in the study group was 5.89 years (0.3 to 11.0) and in the control group was 6.6 years (2.2 to 12.6). There were no revisions in either group. The mean Mayo elbow performance score improved from 29 to 96 in the study group, with similar improvement in the control group (28 to 87). The study group had excellent results in 13 elbows and good results in two. The control group had excellent results in seven and good results in six.

Our experience indicates that previous resection of the radial head and synovectomy are not associated with an increased rate of revision following subsequent arthroplasty of the elbow. However, there was a higher rate of complication in the study group compared with the control group.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 196 - 201
1 Feb 2007
Veitch S Blake SM David H

We prospectively reviewed 14 patients with deficiency of the proximal pole of the scaphoid who were treated by rib osteochondral replacement arthroplasty.

Improvement in wrist function occurred in all except one patient with enhanced grip strength, less pain and maintenance of wrist movement. In 13 patients wrist function was rated as good or excellent according to the modified wrist function score of Green and O’Brien. The mean pre-operative score of 54 (35 to 80) rose to 79 (50 to 90) at review at a mean of 64 months (27 to 103). Carpal alignment did not deteriorate in any patient and there were no cases of nonunion or significant complications.

This procedure can restore the mechanical integrity of the proximal pole of the scaphoid satisfactorily and maintain wrist movement while avoiding the potential complications of alternative replacement arthroplasty techniques and problems associated with vascularised grafts and salvage techniques.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 668 - 672
1 May 2013
Abdel MP Hattrup SJ Sperling JW Cofield RH Kreofsky CR Sanchez-Sotelo J

Instability after arthroplasty of the shoulder is difficult to correct surgically. Soft-tissue procedures and revision surgery using unconstrained anatomical components are associated with a high rate of failure. The purpose of this study was to determine the results of revision of an unstable anatomical shoulder arthroplasty to a reverse design prosthesis. Between 2004 and 2007, 33 unstable anatomical shoulder arthroplasties were revised to a reverse design. The mean age of the patients was 71 years (53 to 86) and their mean follow-up was 42 months (25 to 71). The mean time to revision was 26 months (4 to 164). Pain scores improved significantly (pre-operative visual analogue scale (VAS) of 7.2 (sd 1.6); most recent VAS 2.2 (sd 1.9); p = 0.001). There was a statistically significant increase in mean active forward elevation from 40.2° (sd 27.3) to 97.0° (sd 36.2) (p = 0.001). There was no significant difference in internal (p = 0.93) or external rotation (p = 0.40). Radiological findings included notching in five shoulders (15%) and heterotopic ossification of the inferior capsular region in three (9%). At the last follow-up 31 shoulders (94%) were stable. The remaining two shoulders dislocated at 2.5 weeks and three months post-operatively, respectively. According to the Neer rating system, there were 13 excellent (40%), ten satisfactory (30%) and ten unsatisfactory results (30%). Revision of hemiarthroplasty or anatomical total shoulder replacement for instability using a reverse design prosthesis gives good short-term results.

Cite this article: Bone Joint J 2013;95-B:668–72.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 396 - 400
1 Mar 2013
Rhee SH Kim J Lee YH Gong HS Lee HJ Baek GH

The purpose of this study was to evaluate the risk of late displacement after the treatment of distal radial fractures with a locking volar plate, and to investigate the clinical and radiological factors that might correlate with re-displacement. From March 2007 to October 2009, 120 of an original cohort of 132 female patients with unstable fractures of the distal radius were treated with a volar locking plate, and were studied over a follow-up period of six months. In the immediate post-operative and final follow-up radiographs, late displacement was evaluated as judged by ulnar variance, radial inclination, and dorsal angulation. We also analysed the correlation of a variety of clinical and radiological factors with re-displacement. Ulnar variance was significantly overcorrected (p < 0.001) while radial inclination and dorsal angulation were undercorrected when compared statistically (p <  0.001) with the unaffected side in the immediate post-operative stage. During follow-up, radial shortening and dorsal angulation progressed statistically, but none had a value beyond the acceptable range. Bone mineral density measured at the proximal femur and the position of the screws in the subchondral region, correlated with slight progressive radial shortening, which was not clinically relevant.

Volar locking plating of distal radial fractures is a reliable form of treatment without substantial late displacement.

Cite this article: Bone Joint J 2013;95-B:396–400.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 509 - 514
1 Apr 2006
Aldridge JM Lightdale NR Mallon WJ Coonrad RW

There have been few reports in the literature of total elbow arthroplasty extending beyond 10 to 15 years. We reviewed 40 patients (41 elbows) with a mean age of 56 years (19 to 83) who had undergone a Coonrad/Coonrad-Morrey elbow arthroplasty by one surgeon for various diagnoses between 1974 and 1994. Surgical selection excluded patients with previous elbow infection or who refused to accept a sedentary level of elbow activity postoperatively. Objective data were collected from charts, radiographs, clinical photographs and supplemented by the referring orthopaedic surgeons’ records and radiographs if health or distance prevented a patient from returning for final review. Subjective outcome was defined by patient satisfaction.

Of the 41 elbows, 21 were functional between 10 and 14 years after operation, ten between 15 and 19 years and ten between 20 and 31 years. There were 14 complications and 13 revisions, but no cases of acute infection, or permanent removal of any implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 84 - 89
1 Jan 2006
Strauss EJ Tejwani NC Preston CF Egol KA

The type II Monteggia (posterior) lesion is a rare injury which is sometimes associated with ulnohumeral instability. We have reviewed 23 of 28 patients with this injury. A clinical and radiographic assessment was undertaken at follow-up. Functional outcome scores, including the Broberg and Morrey Index and the Disabilities of the Arm, Shoulder or Hand (DASH), were used. The results from the six patients with associated posterior ulnohumeral dislocation were compared with 17 without ulnohumeral injury. Those with dislocation had reduced movement of the elbow and had outcome scores indicative of greater disability compared to those without associated dislocation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 230 - 234
1 Feb 2010
Anderson GA Thomas BP Pallapati SCR

Inability to actively supinate the forearm makes common activities of daily living and certain vocational activities awkward or impossible to perform. A total of 11 patients with deficient supination of the arm underwent transfer of the tendon of flexor carpi ulnaris to the split tendon of brachioradialis with its bony insertion into the radial styloid left intact. Active supination beyond neutral rotation was a mean of 37.2° (25° to 49.5°) at a minimum follow-up of three years, representing a significant improvement (95% confidence interval 25 to 50, p < 0.001). Functional evaluation of the hand after this transfer showed excellent and good results in ten patients and fair in one.

The split tendon of brachioradialis as an insertion for transfer of the flexor carpi ulnaris appears to provide adequate supination of the forearm without altering the available pronation and avoids the domination of wrist extension sometimes associated with transfers of the flexor carpi ulnaris to the radial extensors of the wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 721 - 728
1 Jun 2012
Goudie EB Murray IR Robinson CM

Dislocation of the shoulder may occur during seizures in epileptics and other patients who have convulsions. Following the initial injury, recurrent instability is common owing to a tendency to develop large bony abnormalities of the humeral head and glenoid and a susceptibility to further seizures. Assessment is difficult and diagnosis may be missed, resulting in chronic locked dislocations with protracted morbidity. Many patients have medical comorbidities, and successful treatment requires a multidisciplinary approach addressing the underlying seizure disorder in addition to the shoulder pathology. The use of bony augmentation procedures may have improved the outcomes after surgical intervention, but currently there is no evidence-based consensus to guide treatment. This review outlines the epidemiology and pathoanatomy of seizure-related instability, summarising the currently-favoured options for treatment, and their results.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 577 - 583
1 May 2012
Smith CD Guyver P Bunker TD

The outcome of an anatomical shoulder replacement depends on an intact rotator cuff. In 1981 Grammont designed a novel large-head reverse shoulder replacement for patients with cuff deficiency. Such has been the success of this replacement that it has led to a rapid expansion of the indications. We performed a systematic review of the literature to evaluate the functional outcome of each indication for the reverse shoulder replacement. Secondary outcome measures of range of movement, pain scores and complication rates are also presented.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 194 - 199
1 Feb 2008
Sosna A Pokorny D Hromádka R Jahoda D Barták V Pinskerová V

The results of proximal humeral replacement following trauma are substantially worse than for osteoarthritis or rheumatoid arthritis. The stable reattachment of the lesser and greater tuberosity fragments to the rotator cuff and the restoration of shoulder biomechanics are difficult. In 1992 we developed a prosthesis designed to improve fixation of the tuberosity fragments in comminuted fractures of the proximal humerus. The implant enables fixation of the fragments to the shaft of the prosthesis and the diaphyseal fragment using screws, washers and a special toothed plate. Between 1992 and 2003 we used this technique in 50 of 76 patients referred to our institution for shoulder reconstruction after trauma. In the remaining 26, reconstruction with a prosthesis and nonabsorbable sutures was performed, as the tuberosity fragments were too small and too severely damaged to allow the use of screws and the toothed plate.

The Constant score two years post-operatively was a mean of 12 points better in the acute trauma group and 11 points better in the late post-traumatic group than in the classical suture group.

We recommend this technique in patients where the tuberosity fragments are large enough to allow fixation with screws, washers and a toothed plate.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 899 - 905
1 Jul 2008
Dias JJ Dhukaram V Abhinav A Bhowal B Wildin CJ

We report the outcome at a mean of 93 months (73 to 110) of 71 patients with an acute fracture of the scaphoid who were randomised to Herbert screw fixation (35) or below-elbow plaster cast immobilisation (36). These 71 patients represent the majority of a randomised series of 88 patients whose short-term outcome has previously been reported. Those patients available for later review were similar in age, gender and hand dominance.

There was no statistical difference in symptoms and disability as assessed by the mean Patient Evaluation Measure (p = 0.4), or mean Patient-Rated Wrist Evaluation (p = 0.9), the mean range of movement of the wrist (p = 0.4), mean grip strength (p = 0.8), or mean pinch strength (p = 0.4).

Radiographs were available from the final review for 59 patients. Osteoarthritic changes were seen in the scaphotrapezial and radioscaphoid joints in eight (13.5%) and six patients (10.2%), respectively. Three patients had asymptomatic lucency surrounding the screw. One non-operatively treated patient developed nonunion with avascular necrosis. In five patients who were treated non-operatively (16%) there was an abnormal scapholunate angle ( > 60°), but in four of these patients this finding was asymptomatic.

No medium-term difference in function or radiological outcome was identified between the two treatment groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1620 - 1626
1 Dec 2007
Toma CD Machacek P Bitzan P Assadian O Trieb K Wanivenhaus A

We retrospectively compared wrist arthrodesis using the Mannerfelt technique in 19 or an AO-plate in 23 patients with long-standing rheumatoid arthritis. The mean follow-up was for 76 months.

Compared with the Mannerfelt fusion group, patients in the AO-plate group reported greater satisfaction with their wrist function (74% vs 37%, p = 0.015). Complications were reported in six wrists in the AO-plate group and two wrists in the Mannerfelt fusion group (p = 0.258). At final follow-up, 95% of patients (41) reported either no pain or only mild pain. There was improvement in flexion of the finger joints in both groups but no significant improvement in the extension lag in either group.

Both methods relieve pain and improve function. Overall, the activities of daily living scores and the patients’ subjective assessment of outcome tended to be higher in the AO-plate group than in the Mannerfelt fusion group, although the difference was not statistically significant. Similarly, although more postoperative complications occurred in the AO-plate group, the difference between the two groups was not statistically significant.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 210 - 216
1 Feb 2011
Young A Walch G Boileau P Favard L Gohlke F Loew M Molé D

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening (sd) as endpoints. The Constant score was found to improve from a mean of 26.8 (sd 10.3) pre-operatively to 57.6 (sd 20.0) post-operatively (p < 0.001). Active forward flexion improved from a mean of 85.3° (sd 27.4) pre-operatively to 125° (sd 37.3) postoperatively (p < 0.001). External rotation improved from a mean of 7° (sd 6.5) pre-operatively to 30.3° (sd 21.8°) post-operatively (p < 0.001). Survivorship with revision of the glenoid component as the endpoint was 99.1% at five years, 94.5% at ten years and 79.4% at 15 years. Survivorship with radiological loosening as the endpoint was 99.1% at five years, 80.3% at ten years and 33.6% at 15 years.

Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 535 - 539
1 Apr 2010
Cazeneuve JF Cristofari D

We have previously described the short-term outcome of the use of reverse shoulder arthroplasty in the treatment of acute complex proximal humeral fractures in the elderly. We now report the clinical and radiological outcome of 36 fractures at a mean of 6.6 years (1 to 16). Previously, at a mean follow-up of 6 years (1 to 12) the mean Constant score was 58.5; this was reduced to 53 points with the further follow-up. A total of 23 patients (63%) had radiological evidence of loosening of the glenoid component. Nevertheless, only one patient had aseptic loosening of the baseplate at 12 years’ follow-up.

The reduction in the mean Constant score with longer follow-up and the further development of scapular notching is worrying.

New developments in design, bearing surfaces and surgical technique, and further follow-up, will determine whether reverse shoulder arthroplasty has a place in the management of complex proximal humeral fractures in the elderly.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 651 - 655
1 May 2010
Meuffels DE Schuit H van Biezen FC Reijman M Verhaar JAN

We present the long-term outcome, at a median of 18 years (12.8 to 23.5) of open posterior bone block stabilisation for recurrent posterior instability of the shoulder in a heterogenous group of 11 patients previously reported on in 2001 at a median follow-up of six years.

We found that five (45%) would not have chosen the operation again, and that four (36%) had further posterior dislocation. Clinical outcome was significantly worse after 18 years than after six years of follow-up (median Rowe score of 60 versus 90 (p = 0.027)). The median Western Ontario Shoulder Index was 60% (37% to 100%) at 18 years’ follow-up, which is a moderate score. At the time of surgery four (36%) had glenohumeral radiological osteoarthritis, which was present in all after 18 years.

This study showed poor long-term results of the posterior bone block procedure for posterior instability and a high rate of glenohumeral osteoarthritis although three patients with post-traumatic instability were pleased with the result of their operations.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 970 - 974
1 Jul 2010
Foruria AM Sperling JW Ankem HK Oh LS Cofield RH

This study was performed to review the safety and outcome of total shoulder replacements in patients who are ≥ 80 years of age. A total of 50 total shoulder replacements in 44 patients at a mean age of 82 years (80 to 89) were studied. Their health and shoulder status, the operation and post-operative course were analysed, including pain, movement, patient satisfaction, medical and surgical complications, radiographs, the need for revision surgery, and implant and patient survival. A total of 27 patients had an ASA classification of III or IV and medical abnormalities were common. Of the 13 shoulders with bony deficiency of the glenoid, nine required grafting. The duration of hospital stay was prolonged and blood transfusions were common. There were no peri-operative deaths. The mean follow-up was for 5.5 years (2 to 12). Pain was significantly reduced (p < 0.001) and movement improved in active elevation and both external and internal rotation (p < 0.001). Using the Neer scale for assessing outcome, 40 (80%) shoulders had an excellent or satisfactory result. There were medical or surgical complications in 17 cases. Four shoulders developed radiological evidence of loosened glenoid components, and three of these had a poor outcome. Three other shoulders required revision, two for instability. By the time of this review 39 of the patients had died from unrelated causes at a mean of 7.5 years (0.8 to 16.4) after surgery.

Total shoulder replacement is a relatively effective treatment in this elderly group of patients. However, there is a requirement for more intense patient care in the peri-operative period, and non-fatal medical or surgical complications are common. Most of these elderly patients will have a comfortable functional shoulder for the rest of their lives.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 496 - 501
1 Apr 2006
Haines JF Trail IA Nuttall D Birch A Barrow A

We have undertaken a prospective clinical and radiological analysis of 124 shoulder arthroplasties (113 patients) carried out for osteoarthritis. The clinical results showed improvement in the absolute Constant score and the American Shoulder and Elbow Surgeons score of 22 and 43, respectively. Both were statistically significant (p < 0.001). There was no significant difference in the scores after hemiarthroplasty and total arthroplasty in those patients with an intact rotator cuff.

When revision was used as the end-point for survival at ten years, survival of 86%, or 90% if glenoid components made of Hylamer sterilised in air were omitted, was obtained in primary osteoarthritis. The most common cause for revision in the hemiarthroplasty group was glenoid pain at a mean of 1.5 years; in the total arthroplasty group it was loosening of the glenoid at a mean of 4.5 years. Analysis of pre-operative factors showed that the risk of gross loosening of the glenoid increased threefold when there was evidence of erosion of the glenoid at operation. Shoulder arthroplasty should not be delayed once symptomatic osteoarthritis has been established and should be undertaken before failure of the cuff or erosion of the glenoid are present.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1369 - 1374
1 Oct 2005
Athwal GS Chin PY Adams RA Morrey BF

We reviewed 20 patients who had undergone a Coonrad-Morrey total elbow arthroplasty after resection of a primary or metastatic tumour from the elbow or distal humerus between 1980 and 2002. Eighteen patients underwent reconstruction for palliative treatment with restoration of function after intralesional surgery and two after excision of a primary bone tumour. The mean follow-up was 30 months (1 to 192).

Five patients (25%) were alive at the final follow-up; 14 (70%) had died of their disease and one of unrelated causes. Local control was achieved in 15 patients (75%). The mean Mayo Elbow Performance Score improved from 22 (5 to 45) to 75 points (55 to 95). Four reconstructions (20%) failed and required revision. Seven patients (35%) had early complications, the most frequent being nerve injury (25%). There were no infections or wound complications although 18 patients (90%) had radiotherapy, chemotherapy or both.

The Coonrad-Morrey total elbow arthroplasty provides good relief from pain and a good functional outcome after resection of tumours of the elbow. The rates of complications involving local recurrence of tumour (25%) and nerve injury (25%) are of concern.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1096 - 1101
1 Aug 2005
Maynou C Cassagnaud X Mestdagh H

We compared the long-term function of subscapularis after the Latarjet procedure using two surgical approaches. We treated 102 patients (106 shoulders) with a mean age of 26.8 years (15 to 51) with involuntary unidirectional recurrent instability. The operation was carried out through an L-shaped incision with trans-section of the upper two-thirds of the muscle in 69 cases and with a subscapularis split in 37. All clinical results were assessed by the Rowe and the Duplay scores and the function of subscapularis by evaluating the distance and strength at the lift-off position. Bilateral CT was performed in 77 patients for assessment of fatty degeneration. The mean follow-up was 7.5 years (2 to 15) and 18% of cases were lost to follow-up. The mean Duplay score was 82 of 100 for the L-shaped incision group and 90 of 100 for those with a subscapularis split (p = 0.02). The mean fatty degeneration score was 1.18 after an L-shaped incision compared with 0.12 after subscapularis split (p = 0.001). The subscapularis split approach is therefore recommended.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 387 - 392
1 Mar 2010
Kasten P Pape G Raiss P Bruckner T Rickert M Zeifang F Loew M

We have investigated the mid-term outcome of total shoulder replacement using a keeled cemented glenoid component and a modern cementing technique with regard to the causes of failure and loosening of the components.

Between 1997 and 2003 we performed 96 total shoulder replacements on 88 patients, 24 men and 64 women with a mean age of 69.7 years (31 to 82). The minimum follow-up was five years and at the time of review 87 shoulders (77 patients) were examined at a mean follow-up of 89.1 months (60 to 127). Cumulative survival curves were generated with re-operations (accomplished and planned), survivorship of the proshesis, loosening of the glenoid (defined as tilt > 5° or subsidence > 5 mm), the presence of radiolucent lines and a Constant score of < 30 as the endpoints.

There were two re-operations not involving revision of the implants and the survival rate of the prosthesis was 100.0% for the follow-up period, with an absolute Constant score of > 30 as the endpoint the survival rate was 98%. Radiological glenoid loosening was 9% after five years, and 33% after nine years. There was an incidence of 8% of radiolucent lines in more than three of six zones in the immediate post-operative period, of 37.0% after the first year which increased to 87.0% after nine years. There was no correlation between the score of Boileau and the total Constant score at the latest follow-up, but there was correlation between glenoid loosening and pain (p = 0.001).

We found that total shoulder replacement had an excellent mid-term survivorship and clinical outcome. The surgical and cementing techniques were related to the decrease in radiolucent lines around the glenoid compared with earlier studies. One concern, however, was the fact that radiolucent lines increased over time and there was a rate of glenoid loosening of 9% after five years and 33% after nine years. This suggests that the design of the glenoid component, and the implantation and cementing techniques may need further improvement.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1601 - 1606
1 Dec 2009
Kwon BC Choi S Shin J Baek GH

Advanced osteoarthritis of the wrist or the distal articulation of the lunate with the capitate has traditionally been treated surgically by arthrodesis. In order to maintain movement, we performed proximal row carpectomy with capsular interposition arthroplasty as an alternative to arthrodesis in eight patients with advanced arthritis and retrospectively reviewed their clinical and radiographic outcomes after a mean follow-up of 41 months (13 to 53). The visual analogue scale (VAS) for pain at its worst and at rest, and the patient-rated wrist evaluation score improved significantly after surgery, whereas ranges of movement and grip strength were maintained at the pre-operative levels. Progression of arthritis in the radiocapitate joint was observed in three patients, but their outcomes were not significantly different from those without progression of arthritis.

Proximal row carpectomy with capsular interposition arthroplasty is a reasonable option for the treatment of patients with advanced arthritis of the wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1335 - 1340
1 Oct 2009
Kontakis GM Tosounidis TI Christoforakis Z Hadjipavlou AG

We reviewed the outcome of 28 patients who had been treated using the Aequalis fracture prosthesis for an acute fracture of the proximal humerus at a mean follow-up of 39.3 months (24 to 63). The mean age of the patients at the time of the fracture was 66.3 years (38 to 80). The mean Constant score was 68.2 (37 to 84) for the operated shoulder, which represented 89.5% of the mean score for the uninjured side (p < 0.001). The quality of the reconstruction as shown on the immediate post-operative radiographs was categorised into three types, anatomical, acceptable, and unacceptable, depending on the position of the tuberosities relative to the prosthetic head and the humeral shaft. Anatomical reconstruction was associated with a higher mean Constant score as well as higher mean values of anterior forward elevation, abduction and external rotation than the other types, but the differences were not statistically significant (p > 0.231).

A total of 18 patients had active anterior elevation ≥150°. Their mean active abduction and external rotation were 163.6° and 31.3°, respectively. In seven of the 28 patients, the mean active anterior elevation, abduction and external rotation were 130.7°, 129.2° and 22.8°, respectively. In all, 12 patients were very satisfied with the results, 12 were satisfied, two were dissatisfied and two were disappointed; 26 reported no or only mild pain while only two had moderate pain. In five patients proximal migration of the humeral head was shown on the anteroposterior radiographs of the shoulder. No evidence of loosening was found in any prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs.

Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis.

Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 619 - 626
1 May 2009
Herrera DA Anavian J Tarkin IS Armitage BA Schroder LK Cole PA

Between 1998 and 2007, 22 patients with fractures of the scapula had operative treatment more than three weeks after injury. The indications for operation included displaced intra-articular fractures, medialisation of the glenohumeral joint, angular deformity, or displaced double lesions of the superior shoulder suspensory complex.

Radiological and functional outcomes were obtained for 16 of 22 patients. Disabilities of the Arm, Shoulder, Hand (DASH) and Short form-36 scores were collected for 14 patients who were operated on after March 2002. The mean delay from injury to surgery was 30 days (21 to 57). The mean follow-up was for 27 months (12 to 72). At the last review the mean DASH score was 14 (0 to 41). Of the 16 patients with follow-up, 13 returned to their previous employment and recreational activities without restrictions. No wound complications, infection or nonunion occurred.

Malunion of the scapula can be prevented by surgical treatment of fractures in patients with delayed presentation. Surgery is safe, effective, and gives acceptable functional results.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 343 - 348
1 Mar 2008
Prasad N Dent C

We analysed the outcome of the Coonrad-Morrey total elbow replacement used for fracture of the distal humerus in elderly patients with no evidence of inflammatory arthritis and compared the results for early versus delayed treatment. We studied a total of 32 patients with 15 in the early treatment group and 17 in the delayed treatment group. The mean follow-up was 56.1 months (18 to 88). The percentage of excellent to good results based on the Mayo elbow performance score was not significantly different, 84% in the early group and 79% in the delayed group. Subjective satisfaction was 92% in both the groups.

One patient in the early group developed chronic regional pain syndrome and another type 4 aseptic loosening. Two elbows in the early group also showed type 1 radiological loosening.

Two patients in the delayed group had an infection, two an ulnar nerve palsy, one developed heterotopic ossification and one type 4 aseptic loosening. Two elbows in this group also showed type 1 radiological loosening. The Kaplan-Meier survivorship analysis for the early and delayed treatment groups was 93% at 88 months and 76% at 84 months, respectively.

No significant difference was found between the two groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1059 - 1065
1 Aug 2008
Elhassan B Ozbaydar M Massimini D Diller D Higgins L Warner JJP

Transfer of pectoralis major has evolved as the most favoured option for the management of the difficult problem of irreparable tears of subscapularis. We describe our experience with this technique in 30 patients divided into three groups. Group I comprised 11 patients with a failed procedure for instability of the shoulder, group II included eight with a failed shoulder replacement and group III, 11 with a massive tear of the rotator cuff. All underwent transfer of the sternal head of pectoralis major to restore the function of subscapularis.

At the latest follow-up pain had improved in seven of the 11 patients in groups I and III, but in only one of eight in group II. The subjective shoulder score improved in seven patients in group I, in one in group II and in six in group III. The mean Constant score improved from 40.9 points (28 to 50) in group I, 32.9 (17 to 47) in group II and 28.7 (20 to 42) in group III pre-operatively to 60.8 (28 to 89), 41.9 (24 to 73) and 52.3 (24 to 78), respectively.

Failure of the tendon transfer was highest in group II and was associated with pre-operative anterior subluxation of the humeral head. We conclude that in patients with irreparable rupture of subscapularis after shoulder replacement there is a high risk of failure of transfer of p?ctoralis major, particularly if there is pre-operative anterior subluxation of the humeral head.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 623 - 628
1 May 2006
Gong HS Chung MS Lee YH Lee S Lee JO Baek GH

We have performed a form of lunate replacement arthroplasty, which included excision of the lunate and insertion of a vascularised radial bone flap wrapped in pronator quadratus, for stage IIIB or stage IV Kienböck’s disease, in 41 patients who have been followed up for more than three years.

All patients reported an improvement in their symptoms, and 20 of the 41 became free of pain after the operation. Extension and flexion of the wrist were increased by a mean of 9° and 6°, respectively (p < 0.05). The radioscaphoid angle and the carpal height ratio were not significantly changed and only minimal deterioration was observed due to degenerative change. The size, density or location of the inserted bone did not change with time.

A vascularised radial bone flap wrapped in pronator quadratus can be a reliable treatment option for advanced Kienböck’s disease, when the pedicled bone and muscle envelope acts as a stable spacer for the excised lunate.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 189 - 195
1 Feb 2007
Levy JC Virani N Pupello D Frankle M

We report the use of the reverse shoulder prosthesis in the revision of a failed shoulder hemiarthroplasty in 19 shoulders in 18 patients (7 men, 11 women) with severe pain and loss of function. The primary procedure had been undertaken for glenohumeral arthritis associated with severe rotator cuff deficiency.

Statistically significant improvements were seen in pain and functional outcome. After a mean follow-up of 44 months (24 to 89), mean forward flexion improved by 26.4° and mean abduction improved by 35°. There were six prosthesis-related complications in six shoulders (32%), five of which had severe bone loss of the glenoid, proximal humerus or both. Three shoulders (16%) had non-prosthesis related complications.

The use of the reverse shoulder prosthesis provides improvement in pain and function for patients with failure of a hemiarthroplasty for glenohumeral arthritis and rotator cuff deficiency. However, high rates of complications were associated with glenoid and proximal humeral bone loss.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 78 - 83
1 Jan 2006
Sneftrup SB Jensen SL Johannsen HV Søjbjerg JO

We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 points (40 to 100) at the latest follow-up. There was a marked relief of pain, but the range of movement showed no overall improvement. Two patients had a second revision because of infection and two for aseptic loosening. The estimated five-year survival rate of the prosthesis was 83.1% (95% confidence interval 61.1 to 93.3). Revision elbow arthroplasty using the Coonrad-Morrey implant provided satisfactory results but with complications occurring in 13 cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 677 - 683
1 May 2005
Calvo E Granizo JJ Fernández-Yruegas D

We prospectively evaluated 61 patients treated arthroscopically for anterior instability of the shoulder at a mean follow-up of 44.5 months (24 to 100) using the Rowe scale. Those with post-operative dislocation or subluxation were considered to be failures. Logistic regression analysis was used to identify patients at increased risk of recurrence in order to develop a suitable selection system.

The mean Rowe score improved from 45 pre-operatively to 86 at follow-up (p < 0.001). At least one episode of post-operative instability occurred in 11 patients (18%), although their stability improved (p = 0.018), and only three required revision. Subjectively, eight patients were dissatisfied. Age younger than 28 years, ligamentous laxity, the presence of a fracture of the glenoid rim involving more than 15% of the articular surface, and post-operative participation in contact or overhead sports were associated with a higher risk of recurrence, and scored 1, 1, 5 and 1 point, respectively. Those patients with a total score of two or more points had a relative risk of recurrence of 43% and should be treated by open surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 54 - 61
1 Jan 2005
Sanchez-Sotelo J Morrey BF O’Driscoll SW

We describe the intermediate results of lateral ligamentous repair or reconstruction for posterolateral rotatory instability of the elbow. Between 1986 and 1999, we performed 12 direct repairs and 33 ligament reconstructions with a tendon autograft. One patient was lost to follow-up and 44 were retrospectively studied at a mean of six years (2 to 15).

Surgery restored stability in all except five patients. In two the elbow became stable after a second procedure. The mean post-operative Mayo elbow performance score was 85 points (60 to 100). The result was classified as excellent in 19, good in 13, fair in seven and poor in five patients. Thirty-eight patients (86%) were subjectively satisfied with the outcome of the operation. Better results were obtained in patients with a post-traumatic aetiology (p = 0.03), those with subjective symptoms of instability at presentation (p = 0.006) and those who had an augmented reconstruction using a tendon graft (p = 0.04).

Reconstruction using a tendon graft seems to provide better results than ligament repair and the results do not seem to deteriorate with time. The outcome of this procedure is less predictable in patients with no subjective instability.