To calculate how the likelihood of obtaining measurable benefit from hip or knee arthroplasty varies with preoperative patient-reported scores. Existing UK data from 222,933 knee and 209,760 hip arthroplasty patients were used to model an individual’s probability of gaining meaningful improvement after surgery based on their preoperative Oxford Knee or Hip Score (OKS/OHS). A clinically meaningful improvement after arthroplasty was defined as ≥ 8 point improvement in OHS, and ≥ 7 in OKS.Aims
Methods
To investigate whether elective joint arthroplasty performed
at the weekend is associated with a different 30-day mortality We examined the 30-day cumulative mortality rate (Kaplan-Meier)
for all elective hip and knee arthroplasties performed in England
and Wales between 1st April 2003 and 31st December 2014, comprising
118 096 episodes undertaken at the weekend and 1 233 882 episodes
performed on a weekday. We used Cox proportional-hazards regression
models to assess for time-dependent variation and adjusted for identified
risk factors for mortality.Aims
Patients and Methods
The aim of this study was to define return to
theatre (RTT) rates for elective hip and knee replacement (HR and
KR), to describe the predictors and to show the variations in risk-adjusted
rates by surgical team and hospital using national English hospital
administrative data. We examined information on 260 206 HRs and 315 249 KRs undertaken
between April 2007 and March 2012. The 90-day RTT rates were 2.1%
for HR and 1.8% for KR. Male gender, obesity, diabetes and several
other comorbidities were associated with higher odds for both index
procedures. For HR, hip resurfacing had half the odds of cement fixation
(OR = 0.58, 95% confidence intervals (CI) 0.47 to 0.71). For KR,
unicondylar KR had half the odds of total replacement (OR = 0.49,
95% CI 0.42 to 0.56), and younger ages had higher odds (OR = 2.23,
95% CI 1.65 to 3.01) for ages <
40 years compared with ages 60
to 69 years). There were more funnel plot outliers at three standard deviations
than would be expected if variation occurred on a random basis. Hierarchical modelling showed that three-quarters of the variation
between surgeons for HR and over half the variation between surgeons
for KR are not explained by the hospital they operated at or by
available patient factors. We conclude that 90-day RTT rate may
be a useful quality indicator for orthopaedics. Cite this article:
We compared the length of hospitalisation, rate
of infection, dislocation of the hip and revision, and mortality following
primary hip and knee arthroplasty for osteoarthritis in patients
with Alzheimer’s disease (n = 1064) and a matched control group
(n = 3192). The data were collected from nationwide Finnish health
registers. Patients with Alzheimer’s disease had a longer peri-operative
hospitalisation (median 13 days Cite this article:
We evaluated the duration of hospitalisation,
occurrence of infections, hip dislocations, revisions, and mortality following
primary hip and knee replacement in 857 patients with Parkinson’s
disease and compared them with 2571 matched control patients. The
data were collected from comprehensive nationwide Finnish health
registers. The mean follow-up was six years (1 to 13). The patients
with Parkinson’s disease had a longer mean length of stay (21 days
[1 to 365] Cite this article:
The results of hip and knee replacement surgery
are generally regarded as positive for patients. Nonetheless, they are
both major operations and have recognised complications. We present
a review of relevant claims made to the National Health Service
Litigation Authority. Between 1995 and 2010 there were 1004 claims
to a value of £41.5 million following hip replacement surgery and
523 claims to a value of £21 million for knee replacement. The most common
complaint after hip surgery was related to residual neurological
deficit, whereas after knee replacement it was related to infection.
Vascular complications resulted in the highest costs per case in
each group. Although there has been a large increase in the number of operations
performed, there has not been a corresponding relative increase
in litigation. The reasons for litigation have remained largely
unchanged over time after hip replacement. In the case of knee replacement,
although there has been a reduction in claims for infection, there
has been an increase in claims for technical errors. There has also
been a rise in claims for non-specified dissatisfaction. This information
is of value to surgeons and can be used to minimise the potential
mismatch between patient expectation, informed consent and outcome. Cite this article: