This is a prospective study of 107 repairs of
Residual muscle weakness in
We describe the results of surgical treatment in a prospective study of 183 consecutive cases of subluxation (101) and dislocation (82) of the shoulder secondary to
Hand function was evaluated in 105 patients who had been operated on in early infancy for brachial plexus birth palsy. The mean follow-up after surgery was for 13.4 years (5.0 to 31.5). Fine sensation, stereognosis, grip and pinch strength and the Raimondi scale were recorded. Fine sensation was normal in 34 of 49 patients (69%) with C5–6 injury, 15 of 31 (48%) with C5–7 and in 8 of 25 (32%) with total injury. Loss of protective sensation or absent sensation was noted in some palmar areas of the hand in 12 of 105 patients (11%). Normal stereognosis was recorded in 88 of the 105 patients (84%), whereas only 9 of the 105 (9%) had normal grip strength. The mean Raimondi scale scores were 4.57 (3 to 5) (C5–6), 4.26 (1 to 5) (C5–7) and 2.16 (0 to 5) in patients with total injury. The location of impaired sensation was related to the distribution of the root injury. Avulsion type of injury correlated with poor recovery of hand function.
Inability to actively supinate the forearm makes common activities of daily living and certain vocational activities awkward or impossible to perform. A total of 11 patients with deficient supination of the arm underwent transfer of the tendon of flexor carpi ulnaris to the split tendon of brachioradialis with its bony insertion into the radial styloid left intact. Active supination beyond neutral rotation was a mean of 37.2° (25° to 49.5°) at a minimum follow-up of three years, representing a significant improvement (95% confidence interval 25 to 50, p <
0.001). Functional evaluation of the hand after this transfer showed excellent and good results in ten patients and fair in one. The split tendon of brachioradialis as an insertion for transfer of the flexor carpi ulnaris appears to provide adequate supination of the forearm without altering the available pronation and avoids the domination of wrist extension sometimes associated with transfers of the flexor carpi ulnaris to the radial extensors of the wrist.
A pronation deformity of the forearm following an obstetric brachial plexus injury causes functional and cosmetic disability. We evaluated the results of pronator teres transfer to correct their deformity in 14 children treated over a period of four years. The mean age at surgery was 7.6 years (5 to 15). The indication for surgery in each case was impairment of active supination in a forearm that could be passively supinated provided that there was no medial contracture of the shoulder and normal function of the hand. The median follow-up was 20.4 months (8 to 42). No patient was lost to follow-up. Qualitative results were also assessed. The median active supination improved from 5° (0° to 10°) to 75° (70° to 80°) with no loss of pronation. A passively correctible pronation contracture can be corrected safely and effectively by the transfer of pronator teres.
In adults with brachial plexus injuries, lack
of active external rotation at the shoulder is one of the most common residual
deficits, significantly compromising upper limb function. There
is a paucity of evidence to address this complex issue. We present
our experience of isolated latissimus dorsi (LD) muscle transfer
to achieve active external rotation. This is a retrospective review
of 24 adult post-traumatic plexopathy patients who underwent isolated latissimus
dorsi muscle transfer to restore external rotation of the shoulder
between 1997 and 2010. All patients were male with a mean age of
34 years (21 to 57). All the patients underwent isolated LD muscle
transfer using a standard technique to correct external rotational
deficit. Outcome was assessed for improvement in active external rotation,
arc of movement, muscle strength and return to work. The mean improvement
in active external rotation from neutral was 24° (10° to 50°). The
mean increase in arc of rotation was 52° (38° to 55°). Mean power
of the external rotators was 3.5 Medical Research Council (MRC)
grades (2 to 5). A total of 21 patients (88%) were back in work by the time of
last follow up. Of these,
13 had returned to their pre-injury occupation. Isolated latissimus
dorsi muscle transfer provides a simple and reliable method of restoring
useful active external rotation in adults with brachial plexus injuries
with internal rotational deformity. Cite this article:
Restoration of hand function is rarely achieved after a complete closed traction lesion of the supraclavicular brachial plexus. We describe the injury, treatment, rehabilitation and long-term results of two patients who regained good function of the upper limb and useful function in the hand after such an injury. Successful repairs were performed within six days of injury. Tinel’s sign proved accurate in predicting the ruptures and the distribution of pain was accurate in predicting avulsion. The severe pain that began on the day of injury resolved with the onset of muscle function. Recovery of muscle function preceded recovery of sensation. Recovery of the function of C and Aδ fibres was the slowest of all.
We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity.