If a
Radial head arthroplasty (RHA) may be used in the treatment of
non-reconstructable radial head fractures. The aim of this study
was to evaluate the mid-term clinical and radiographic results of
RHA. Between 2002 and 2014, 77 RHAs were implanted in 54 men and 23
women with either acute injuries (54) or with traumatic sequelae
(23) of a fracture of the radial head. Four designs of RHA were
used, including the Guepar (Small Bone Innovations (SBi)/Stryker;
36), Evolutive (Aston Medical; 24), rHead RECON (SBi/Stryker; ten)
or rHead STANDARD (SBi/Stryker; 7) prostheses. The mean follow-up
was 74.0 months (standard deviation (Aims
Patients and Methods
Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty. Cite this article:
The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).Aims
Methods
The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different. A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes.Aims
Methods
Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA. MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated.Aims
Methods
The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes. We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis.Aims
Methods
Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score.Aims
Methods
The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up. Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening.Aims
Methods
The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up. A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted.Aims
Methods
It has been hypothesized that proximal radial neck resorption (PRNR) following press-fit radial head arthroplasty (RHA) is due to stress-shielding. We compared two different press-fit stems by means of radiographs to investigate whether the shape and size of the stems are correlated with the degree of PRNR. The radiographs of 52 RHAs were analyzed both at 14 days postoperatively and after two years. A cylindrical stem and a conical stem were implanted in 22 patients (group 1) and 30 patients (group 2), respectively. The PRNR was measured in the four quadrants of the radial neck and the degree of stem filling was calculated by analyzing the ratio between the prosthetic stem diameter (PSD) and the medullary canal diameter (MCD) at the proximal portion of the stem (level A), halfway along the stem length (level B), and distally at the stem tip (level C).Aims
Methods
The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.Aims
Methods
To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes. Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible.Aims
Methods
The purpose of this study was to determine whether there were long-term differences in outcomes of reverse shoulder arthroplasty (RSA) undertaken for acute proximal humeral fracture versus rotator cuff deficiency with a minimum follow-up of five years. This was a prospective cohort study comparing 67 patients with acute complex proximal humeral fracture and 64 patients with irreparable rotator cuff deficiency who underwent primary RSA. In the fracture group, there were 52 (77.6%) females and 15 (22.4%) males, with a mean age of 73.5 years (51 to 85), while in the arthropathy group, there were 43 (67.1%) females and 21 (32.9%) males, with a mean age of 70.6 years (50 to 84). Patients were assessed by the Constant score, University of California Los Angeles shoulder score (UCLA), short version of the Disability of the Arm Shoulder and Hand score (QuickDASH), and visual analogue scales (VAS) for pain and satisfaction. Radiological evaluation was also performed.Aims
Methods
The crucial role of the radial head in the stability of the elbow in terrible triad injury is acknowledged. This retrospective study aims to compare the results of resection of a severely comminuted radial head with or without prosthetic arthroplasty as part of the reconstruction for this injury. The outcome of radial head resection was compared with prosthetic arthroplasty in 29 and 15 patients with terrible triad injuries, respectively. There were ten female patients (34.5%) in the resection group and six female patients (40%) in the prosthesis group. The mean age was 40.7 years (Aims
Patients and Methods
Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA). A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).Aims
Patients and Methods
Aims
Patients and Methods
The reasons for failure of a hemirthroplasty (HA) when used to
treat a proximal humeral fracture include displaced or necrotic
tuberosities, insufficient metaphyseal bone-stock, and rotator cuff
tears. Reverse total shoulder arthroplasty (rTSA) is often the only
remaining form of treatment in these patients. The aim of this study
was to evaluate the clinical outcome after conversions from a failed
HA to rTSA. A total of 35 patients, in whom a HA, as treatment for a fracture
of the proximal humerus, had failed, underwent conversion to a rTSA.
A total of 28 were available for follow-up at a mean of 61 months
(37 to 91), having been initially reviewed at a mean of 20 months
(12 to 36) postoperatively. Having a convertible design, the humeral
stem could be preserved in nine patients. The stem was removed in
the other 19 patients and a conventional rTSA was implanted. At
final follow-up, patients were assessed using the American Shoulder
and Elbow Surgeons (ASES) score, the Constant Score, and plain radiographs.Aims
Material and Methods
In the initial development of total shoulder arthroplasty (TSA),
the humeral component was usually fixed with cement. Cementless
components were subsequently introduced. The aim of this study was
to compare the long-term outcome of cemented and cementless humeral
components in arthroplasty of the shoulder. All patients who underwent primary arthroplasty of the shoulder
at our institution between 1970 and 2012 were included in the study.
There were 4636 patients with 1167 cemented humeral components and
3469 cementless components. Patients with the two types of fixation
were matched for nine different covariates using a propensity score
analysis. A total of 551 well-balanced pairs of patients with cemented
and cementless components were available after matching for comparison
of the outcomes. The clinical outcomes which were analysed included loosening
of the humeral component determined at revision surgery, periprosthetic
fractures, post-operative infection and operating time.Aims
Patients and Methods
This pilot study reports the clinical outcomes
of a combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty in patients with rotatator cuff arthropathy. A
total of 30 patients (30 shoulders; eight men and 22 women) with
a mean age of 74 years (55 to 84) were assessed at a mean follow-up
of 31 months (24 to 60). The inclusion criteria were painful cuff
tear arthropathy with normal deltoid function and a non-degenerative subscapularis
muscle and tendon and a preserved teres minor. Outcome was assessed using the University of California Los Angeles
score, the Japanese Orthopaedic Association score, and the Oxford
Shoulder Score. Radiographic measurements included the centre of
rotation distance and the length of the deltoid. All clinical scores were significantly improved post-operatively.
The active flexion and external rotation improved significantly
at the most recent follow-up (p <
0.035). Although the mean centre
of rotation distance changed significantly (p <
0.001), the mean
length of the deltoid did not change significantly from the pre-operative
value (p = 0.29). The change in the length of the deltoid with <
100° flexion was significantly less than that with >
100° (p <
0.001). Progressive erosion of the glenoid was seen in four patients.
No patient required revision or further surgery. A combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty effectively restored function and relieved pain
in patients with rotator cuff arthropathy. Cite this article: 2015;97-B:1090–5.
Osteoarthritis results in changes in the dimensions
of the glenoid. This study aimed to assess the size and radius of curvature
of arthritic glenoids. A total of 145 CT scans were analysed, performed
as part of routine pre-operative assessment before total shoulder
replacement in 91 women and 54 men. Only patients with primary osteoarthritis and
a concentric glenoid were included in the study. The CT scans underwent
three-dimensional (3D) reconstruction and were analysed using dedicated
computer software. The measurements consisted of maximum superoinferior height,
anteroposterior width and a best-fit sphere radius of curvature
of the glenoid. The mean height was 40.2 mm ( With current shoulder replacement systems using a unique backside
radius of curvature for the glenoid component, there is a risk of
undertaking excessive reaming to adapt the bone to the component
resulting in sacrifice of subchondral bone or under-reaming and
instability of the component due to a ’rocking horse‘ phenomenon. Cite this article:
Unlinked, linked and convertible total elbow
arthroplasties (TEAs) are currently available. This study is the
first to report the clinical results of the convertible Latitude
TEA. This was a retrospective study of a consecutive cohort of 63
patients (69 primary TEAs) with a mean age of 60 years (23 to 87).
Between 2006 and 2008 a total of 19 men and 50 women underwent surgery.
The mean follow-up was 43 months (8 to 84). The range of movement,
function and pain all improved six months post-operatively and either
continued to improve slightly or reached a plateau thereafter. The
complication rate is similar to that reported for other TEA systems.
No loosening was seen. Remarkable is the disengagement of the radial
head component in 13 TEAs (31%) with a radial head component implanted. Implantation of both the linked and the unlinked versions of
the Latitude TEA results in improvement of function and decreased
pain, and shows high patient satisfaction at mid-term follow-up. Cite this article:
Short uncemented humeral stems can preserve humeral
bone stock and facilitate revision surgery but may be prone to malalignment
or loosening, especially when used in reverse total shoulder replacement
(TSR). We undertook a retrospective review of 44 patients with a
mean age of 76 years (59 to 92) who underwent primary reverse TSR
with a short uncemented humeral stem. There were 29 females. The
indications for joint replacement included cuff tear associated
arthropathy (33), avascular necrosis (six), post-traumatic arthritis
(two), and inflammatory arthritis (three). At a mean follow-up of
27 months (24 to 40), pain was rated as mild or none in 43 shoulders
(97.7%). The mean active elevation improved from 54° Cite this article: