header advert
Results 1 - 3 of 3
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 659 - 668
1 Jul 2004
Rammelt S Grass R Zawadski T Biewener A Zwipp H

Subtalar distraction bone-block arthrodesis for malunited calcaneal fractures was performed in 31 patients (26 men, five women), with a mean age of 38.5 years. The mean time from injury to arthrodesis was 36 months. There were no cases of nonunion. One patient had an early dislocation of the bone block requiring a repeat arthrodesis, and one had a soft-tissue infection. The mean AOFAS hindfoot score improved significantly from 23.5 before operation to 73.2 at a mean follow-up of 33 months (p > 0.001). Compared with the unaffected side, the talocalcaneal height was corrected by 61.8%, the talus-first metatarsal axis by 46.5%, the talar declination angle by 38.5% and the talocalcaneal angle by 35.4%. Dynamic pedobarography revealed a return to normal of the pressure distribution during roll-over and a more energetic gait. The distribution of local transfer of load correlated well with the AOFAS score. The amount of correction of the heel height correlated with a normal pattern of pressure transfer on the heel (p < 0.05)


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 849 - 854
1 Aug 2001
Trnka H Easley ME Lam PW Anderson CD Schon LC Myerson MS

This retrospective study analyses the results of subtalar bone block distraction arthrodesis used in the treatment of late complications of calcaneal fractures, acute severely comminuted fractures, nonunion (and malunion) of attempted subtalar arthrodeses, avascular necrosis of the talus, and club-foot deformity. Of 39 patients (41 feet) who had this procedure, 35 (37 feet) returned for follow-up after a mean of 70 months (26 to 140). There were 24 men (25 feet) and 11 women (12 feet) with a mean age of 41 years (16 to 63). Each completed a standardised questionnaire, based on the hindfoot-scoring system of the American Orthopaedic Foot and Ankle Society and were reviewed both clinically and radiologically. Of the 37 operations, 32 (87%) achieved union. The mean hindfoot score (maximum of 94 points) increased from 21.1 points (8 to 46) preoperatively to 68.9 (14 to 82) at the final follow-up. The mean talocalcaneal and calcaneal pitch angles were 20.5° and 4.9° before operation, 25.9° and 8.3° immediately after, and 24.6° and 7.7° at the final follow-up, respectively. The mean talar declination angle improved from 6.5° (−10 to 22) before operation to 24.8° (14 to 32) at the final follow-up. The mean talocalcaneal height increased from 68.7 mm before operation to 74.5 mm immediately after and 73.5 mm at the final follow-up. Of the 37 arthrodeses available for review, 32 were successful; 29 patients (30 arthrodeses) were satisfied with the procedure. Minimal loss of hindfoot alignment occurred when comparing radiographs taken immediately after operation and at final follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1032 - 1038
1 Aug 2006
Hopgood P Kumar R Wood PLR

Between 1999 and 2005, 23 failed total ankle replacements were converted to arthrodeses. Three surgical techniques were used: tibiotalar arthrodesis with screw fixation, tibiotalocalcaneal arthrodesis with screw fixation, and tibiotalocalcaneal arthrodesis with an intramedullary nail. As experience was gained, the benefits and problems became apparent. Successful bony union was seen in 17 of the 23 ankles. The complication rate was higher in ankles where the loosening had caused extensive destruction of the body of the talus, usually in rheumatoid arthritis. In this situation we recommend tibiotalocalcaneal arthrodesis with an intramedullary nail. This technique can also be used when there is severe arthritic change in the subtalar joint. Arthrodesis of the tibiotalar joint alone using compression screws was generally possible in osteoarthritis because the destruction of the body of the talus was less extensive. Tibiotalocalcaneal arthrodesis fusion with compression screws has not been successful in our experience.